Ming Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ming Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Baoqing Yang
Department of Radiology, Tongji Hospital, Tongji University School of Medicine, Shanghai 200065, China
1 shared publication - Caiting Chu
Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China
1 shared publication - Chengjin Gao
Department of Emergency, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Jinxi Meng
Department of Radiology, Tongji Hospital, Tongji University School of Medicine, Shanghai 200065, China
1 shared publication - Kangwei Zhang
Department of Medical Imaging, Tongji Hospital, School of Medicine, Tongji University, Shanghai, China
1 shared publication - Lai Wei
Department of Radiology, Tongji Hospital, School of Medicine, Tongji University , Shanghai 200065
1 shared publication
Latest Publications
- Open Access
- 16 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1580
Outcome Prediction of Spontaneous Supratentorial Intracerebral Hemorrhage after Surgical Treatment Based on Non-Contrast Computed Tomography: A Multicenter Study
This study aims to explore the value of a machine learning (ML) model based on radiomics features and clinical features in predicting the outcome of spontaneous supratentorial intracerebral hemorrhage (sICH) 90 days after surgery. A total of 348 patients with sICH underwent craniotomy evacuation of hematoma from three medical centers. One hundred and eight radiomics features were extracted from sICH lesions on baseline CT. Radiomics features were screened using 12 feature selection algorithms. Clinical features included age, gender, admission Glasgow Coma Scale (GCS), intraventricular hemorrhage (IVH), midline shift (MLS), and deep ICH. Nine ML models were constructed based on clinical feature, and clinical features + radiomics features, respectively. Grid search was performed on different combinations of feature selection and ML model for parameter tuning. The averaged receiver operating characteristics (ROC) area under curve (AUC) was calculated and the model with the largest AUC was selected. It was then tested using multicenter data. The combination of lasso regression feature selection and logistic regression model based on clinical features + radiomics features had the best performance (AUC: 0.87). The best model predicted an AUC of 0.85 (95%CI, 0.75–0.94) on the internal test set and 0.81 (95%CI, 0.64–0.99) and 0.83 (95%CI, 0.68–0.97) on the two external test sets, respectively. Twenty-two radiomics features were selected by lasso regression. The second-order feature gray level non-uniformity normalized was the most important radiomics feature. Age is the feature with the greatest contribution to prediction. The combination of clinical features and radiomics features using logistic regression models can improve the outcome prediction of patients with sICH 90 days after surgery.
- 16 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1580
Open AccessOutcome Prediction of Spontaneous Supratentorial Intracerebral Hemorrhage after Surgical Treatment Based on Non-Contrast Computed Tomography: A Multicenter Study
This study aims to explore the value of a machine learning (ML) model based on radiomics features and clinical features in predicting the outcome of spontaneous supratentorial intracerebral hemorrhage (sICH) 90 days after surgery. A total of 348 patients with sICH underwent craniotomy evacuation of hematoma from three medical centers. One hundred and eight radiomics features were extracted from sICH lesions on baseline CT. Radiomics features were screened using 12 feature selection algorithms. Clinical features included age, gender, admission Glasgow Coma Scale (GCS), intraventricular hemorrhage (IVH), midline shift (MLS), and deep ICH. Nine ML models were constructed based on clinical feature, and clinical features + radiomics features, respectively. Grid search was performed on different combinations of feature selection and ML model for parameter tuning. The averaged receiver operating characteristics (ROC) area under curve (AUC) was calculated and the model with the largest AUC was selected. It was then tested using multicenter data. The combination of lasso regression feature selection and logistic regression model based on clinical features + radiomics features had the best performance (AUC: 0.87). The best model predicted an AUC of 0.85 (95%CI, 0.75–0.94) on the internal test set and 0.81 (95%CI, 0.64–0.99) and 0.83 (95%CI, 0.68–0.97) on the two external test sets, respectively. Twenty-two radiomics features were selected by lasso regression. The second-order feature gray level non-uniformity normalized was the most important radiomics feature. Age is the feature with the greatest contribution to prediction. The combination of clinical features and radiomics features using logistic regression models can improve the outcome prediction of patients with sICH 90 days after surgery.
- Open Access
- 14 February 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 485
MRI-Based Radiomics Analysis for Intraoperative Risk Assessment in Gravid Patients at High Risk with Placenta Accreta Spectrum
Background: Gravid patients at high risk with placenta accreta spectrum (PAS) face life-threatening risk at delivery. Intraoperative risk assessment for patients is currently insufficient. We aimed to develop an assessment system of intraoperative risks through MRI-based radiomics. Methods: A total of 131 patients enrolled were randomly grouped according to a ratio of 7:3. Clinical data were analyzed retrospectively. Radiomic features were extracted from sagittal Fast Imaging Employing State-sate Acquisition images. Univariate and multivariate regression analyses were performed to build models using R software. A receiver operating characteristic curve and decision curve analysis (DCA) were performed to determine the predictive performance of models. Results: Six radiomic features and two clinical variables were used to construct the combined model for selection of removal protocols of the placenta, with an area under the curve (AUC) of 0.90 and 0.91 in the training and test cohorts, respectively. Nine radiomic features and two clinical variables were obtained to establish the combined model for prediction of intraoperative blood loss, with an AUC of 0.90 and 0.88 in the both cohorts, respectively. The DCA confirmed the clinical utility of the combined model. Conclusion: The analysis of combined MRI-based radiomics with clinics could be clinically beneficial for patients.
- 14 February 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 485
Open AccessMRI-Based Radiomics Analysis for Intraoperative Risk Assessment in Gravid Patients at High Risk with Placenta Accreta Spectrum
Background: Gravid patients at high risk with placenta accreta spectrum (PAS) face life-threatening risk at delivery. Intraoperative risk assessment for patients is currently insufficient. We aimed to develop an assessment system of intraoperative risks through MRI-based radiomics. Methods: A total of 131 patients enrolled were randomly grouped according to a ratio of 7:3. Clinical data were analyzed retrospectively. Radiomic features were extracted from sagittal Fast Imaging Employing State-sate Acquisition images. Univariate and multivariate regression analyses were performed to build models using R software. A receiver operating characteristic curve and decision curve analysis (DCA) were performed to determine the predictive performance of models. Results: Six radiomic features and two clinical variables were used to construct the combined model for selection of removal protocols of the placenta, with an area under the curve (AUC) of 0.90 and 0.91 in the training and test cohorts, respectively. Nine radiomic features and two clinical variables were obtained to establish the combined model for prediction of intraoperative blood loss, with an AUC of 0.90 and 0.88 in the both cohorts, respectively. The DCA confirmed the clinical utility of the combined model. Conclusion: The analysis of combined MRI-based radiomics with clinics could be clinically beneficial for patients.