Heini Maliya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Heini Maliya has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Qi Guo
Key Laboratory of Functional Materials and Device for Special Environments, Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences 1 , No. 40-1 South Beijing Road, Urumqi 830011, People’s Republic of China
3 shared publications- Yudong Li
Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
3 shared publications Jiawei Chen
Key Laboratory of Functional Materials and Device for Special Environments, Xinjiang Technical Institute of Physics & Chemistry, Chinese Academy of Sciences, No. 40-1 South Beijing Road, Urumqi 830011, PR China
2 shared publications- Abuduwayiti Aierken
School of Physics and Electronic Science, Guizhou Normal University, Guiyang 550025, China
1 shared publication Bingkai Liu
Key Laboratory of Functional Materials and Devices for Special Environments, Xinjiang Technical Institute of Physics and Chemistry, CAS, Urumqi 830011, People’s Republic of China
1 shared publication- Bingyang Li
China Academy of Aerospace Science and Innovation, Beijing 100871, China
1 shared publication
Latest Publications
- 21 September 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (12)
Total ionizing dose and single-event effect of spin–orbit torque magnetic tunnel junctions with different bias conditions
Spin–orbit torque magnetic tunnel junctions (SOT-MTJs) have attracted interest as potential candidates for radiation-tolerant memory applications because of their high speed, low power consumption, and high endurance. Although SOT-MTJs utilize spin for data storage, operations are performed by applying different electrical biases. In conventional silicon-based devices, the applied electric field typically accelerates radiation-induced defect accumulation and dielectric breakdown, and the dynamic radiation stability of SOT-MTJs under these conditions remains largely unexplored. Therefore, we investigated the total ionizing dose and single-event effects of SOT-MTJs under electrical bias using 10 keV x-ray and 1673 MeV Ta-ion irradiation, respectively. Under various bias conditions and dose rates, the tunnel magnetoresistance (TMR) and critical switching current (Ic) of the SOT-MTJs remained highly stable even at a total dose of 1.5 Mrad(Si), with TMR fluctuations of less than 2%. Devices subjected to heavy-ion irradiation exhibited no abnormal switching or breakdown in either the anti-parallel (AP) or parallel (P) state. Furthermore, the average TMR variation in the unbiased device arrays was approximately 1%, while the average Ic remained nearly unchanged. These results demonstrate the radiation stability of the fabricated 320 × 1100 nm2 in-plane SOT-MTJ test vehicles under the investigated total ionizing-dose and heavy-ion irradiation conditions, while providing a device-level reference for future radiation studies of scaled SOT-MRAM technologies.
- 21 September 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (12)
Total ionizing dose and single-event effect of spin–orbit torque magnetic tunnel junctions with different bias conditions
Spin–orbit torque magnetic tunnel junctions (SOT-MTJs) have attracted interest as potential candidates for radiation-tolerant memory applications because of their high speed, low power consumption, and high endurance. Although SOT-MTJs utilize spin for data storage, operations are performed by applying different electrical biases. In conventional silicon-based devices, the applied electric field typically accelerates radiation-induced defect accumulation and dielectric breakdown, and the dynamic radiation stability of SOT-MTJs under these conditions remains largely unexplored. Therefore, we investigated the total ionizing dose and single-event effects of SOT-MTJs under electrical bias using 10 keV x-ray and 1673 MeV Ta-ion irradiation, respectively. Under various bias conditions and dose rates, the tunnel magnetoresistance (TMR) and critical switching current (Ic) of the SOT-MTJs remained highly stable even at a total dose of 1.5 Mrad(Si), with TMR fluctuations of less than 2%. Devices subjected to heavy-ion irradiation exhibited no abnormal switching or breakdown in either the anti-parallel (AP) or parallel (P) state. Furthermore, the average TMR variation in the unbiased device arrays was approximately 1%, while the average Ic remained nearly unchanged. These results demonstrate the radiation stability of the fabricated 320 × 1100 nm2 in-plane SOT-MTJ test vehicles under the investigated total ionizing-dose and heavy-ion irradiation conditions, while providing a device-level reference for future radiation studies of scaled SOT-MRAM technologies.
- Open Access
- 1 November 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (11)
Study of displacement damage effects in InGaAs PIN photodiode under 10 MeV proton irradiation
The displacement damage effect of 10 MeV proton radiation on a high-speed InGaAs PIN photodiode has been experimentally investigated to evaluate the stability of the device in a space radiation environment. The results show that the dark current and low-frequency noise of the device increase significantly after irradiation, while the capacitance of the device decreases slightly after irradiation, where the spectral response parameters are less affected by irradiation. The increase in dark current is essentially linear with the displacement damage dose. Finally, the effect of proton irradiation on the optical communication system is simulated and the results show that the bit error rate of the system increases with the increase in irradiation fluence, which seriously affects the sensitivity of the optical communication system.
- 1 November 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (11)
Open AccessStudy of displacement damage effects in InGaAs PIN photodiode under 10 MeV proton irradiation
The displacement damage effect of 10 MeV proton radiation on a high-speed InGaAs PIN photodiode has been experimentally investigated to evaluate the stability of the device in a space radiation environment. The results show that the dark current and low-frequency noise of the device increase significantly after irradiation, while the capacitance of the device decreases slightly after irradiation, where the spectral response parameters are less affected by irradiation. The increase in dark current is essentially linear with the displacement damage dose. Finally, the effect of proton irradiation on the optical communication system is simulated and the results show that the bit error rate of the system increases with the increase in irradiation fluence, which seriously affects the sensitivity of the optical communication system.
- Open Access
Effects of Electron Irradiation and Temperature on Mechanical Properties of Polyimide Film
Polyimide (PI) is widely deployed in space missions due to its good radiation resistance and durability. The influences from radiation and harsh temperatures should be carefully evaluated during the long-term service life. In the current work, the coupled thermal and radiation effects on the mechanical properties of PI samples were quantitatively investigated via experiments. At first, various PI specimens were prepared, and electron irradiation tests were conducted with different fluences. Then, both uniaxial tensile tests at room temperature and the dynamic mechanical analysis at varied temperatures of PI specimens with and without electron irradiation were performed. After that, uniaxial tensile tests at low and high temperatures were performed. The fracture surface of the PI film was observed using a scanning electron microscope, and its surface topography was measured using atomic force microscopy. In the meantime, the Fourier-transform infrared spectrum tests were conducted to check for chemical changes. In conclusion, the tensile tests showed that electron irradiation has a negligible effect during the linear stretching period but significantly impacts the hardening stage and elongation at break. Moreover, electron irradiation slightly influences the thermal properties of PI according to the differential scanning calorimetry results. However, both high and low temperatures dramatically affect the elastic modulus and elongation at break of PI.
Open AccessEffects of Electron Irradiation and Temperature on Mechanical Properties of Polyimide Film
Polyimide (PI) is widely deployed in space missions due to its good radiation resistance and durability. The influences from radiation and harsh temperatures should be carefully evaluated during the long-term service life. In the current work, the coupled thermal and radiation effects on the mechanical properties of PI samples were quantitatively investigated via experiments. At first, various PI specimens were prepared, and electron irradiation tests were conducted with different fluences. Then, both uniaxial tensile tests at room temperature and the dynamic mechanical analysis at varied temperatures of PI specimens with and without electron irradiation were performed. After that, uniaxial tensile tests at low and high temperatures were performed. The fracture surface of the PI film was observed using a scanning electron microscope, and its surface topography was measured using atomic force microscopy. In the meantime, the Fourier-transform infrared spectrum tests were conducted to check for chemical changes. In conclusion, the tensile tests showed that electron irradiation has a negligible effect during the linear stretching period but significantly impacts the hardening stage and elongation at break. Moreover, electron irradiation slightly influences the thermal properties of PI according to the differential scanning calorimetry results. However, both high and low temperatures dramatically affect the elastic modulus and elongation at break of PI.
- Open Access
Annealing effects of 850 nm vertical-cavity surface-emitting lasers after proton irradiation
- Open Access
Tolerance of Perovskite Solar Cells under Proton and Electron Irradiation
In this work, radiation experiments and simulations were carried out on perovskite solar cells (PSCs). The experimental results show that the PSCs in this work were robust to proton irradiation but more sensitive to electron irradiation, which is different from the results of previous studies. Simulations based on the Monte Carlo method show that the energy loss at the interface was much higher than that in the material bulk, and the interface was more sensitive to electron incidents.
Open AccessTolerance of Perovskite Solar Cells under Proton and Electron Irradiation
In this work, radiation experiments and simulations were carried out on perovskite solar cells (PSCs). The experimental results show that the PSCs in this work were robust to proton irradiation but more sensitive to electron irradiation, which is different from the results of previous studies. Simulations based on the Monte Carlo method show that the energy loss at the interface was much higher than that in the material bulk, and the interface was more sensitive to electron incidents.
- 22 December 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (1) , 012001
Displacement damage effects in proton irradiated vertical-cavity surface-emitting lasers
The displacement damage effects of vertical-cavity surface-emitting lasers (VCSELs) irradiated by 3 and 10 MeV protons in the range of Ф = 6.7 × 10 12 p cm −2 to Ф = 1.6 × 10 14 p cm −2 were investigated. The threshold current exhibited consistent degradation at the same displacement damage dose, as did the series resistance. Additionally, the external quantum efficiencies of 850 and 680 nm VCSELs were degraded by 2% and 21%, respectively. Further, the threshold current of the 850 nm VCSEL was restored by 14% after annealing at 20 mA, which is remarkably higher than that achieved by annealing only at high temperatures. These results support the applicability of VCSELs to both data communication and instrumentation applications in harsh radiation environments.
- 22 December 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (1) , 012001
Displacement damage effects in proton irradiated vertical-cavity surface-emitting lasers
The displacement damage effects of vertical-cavity surface-emitting lasers (VCSELs) irradiated by 3 and 10 MeV protons in the range of Ф = 6.7 × 10 12 p cm −2 to Ф = 1.6 × 10 14 p cm −2 were investigated. The threshold current exhibited consistent degradation at the same displacement damage dose, as did the series resistance. Additionally, the external quantum efficiencies of 850 and 680 nm VCSELs were degraded by 2% and 21%, respectively. Further, the threshold current of the 850 nm VCSEL was restored by 14% after annealing at 20 mA, which is remarkably higher than that achieved by annealing only at high temperatures. These results support the applicability of VCSELs to both data communication and instrumentation applications in harsh radiation environments.
- 1 September 2020
- Published by Elsevier in Thin Solid Films
- Vol. 709, 138237
1 meV electron irradiation and post-annealing effects of GaInAsN diluted nitride alloy with 1 eV bandgap energy
- 1 September 2020
- Published by Elsevier in Thin Solid Films
- Vol. 709, 138237
1 meV electron irradiation and post-annealing effects of GaInAsN diluted nitride alloy with 1 eV bandgap energy