Nitesh Kumar Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nitesh Kumar Singh has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jitendra Kumar
Department of Biomedical Engineering, B V Raju Institute of Technology, Narsapur, Medak, Telangana, India
3 shared publications - Khemraj Deshmukh
Department of Biomedical Engineering, Mody University of Science and Technology, Sikar, Rajasthan, India
2 shared publications - Nishant Kumar Singh
National Institute of Technology
2 shared publications - Anuj Rohatgi
Department of Biomedical Engineering, Mody University of Science and Technology, Sikar, Rajasthan, India
1 shared publication - Ashish Dhar Diwan
Spine Labs, St George and Sutherland Clinical School, University of New South Wales, Sydney, Australia
1 shared publication Bratajit Basu
Department of Biomedical Engineering, Parul Institute of Technology, Parul University, Vadodara, Gujarat, India
1 shared publication
Latest Publications
- 11 May 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (21)
Computational Investigation of Non-Newtonian Physiological Flow and Slip Boundary Effects on Biofilm-Inhibitory TPMS Scaffold Design
This study presents a computational rheology approach to assess the impact of scaffold shape and fluid dynamics on biofilm suppression. CFD simulations used COMSOL Multiphysics 5.6, which included laminar flow, solid mechanics, and FSI modules, and the studies were conducted on 12 scaffold architectures, comprising solid scaffolds (10% porosity) and TPMSbased IWP scaffolds (50% and 70% porosity). Six inlet velocity profiles sinusoidal and physiological were utilized to evaluate axial velocity, pressure, shear rate, stress, strain tensor, strain principal, deformation gradient and displacement gradient under slip wall boundary conditions for both Newtonian and non-Newtonian fluid types. Data from 12 observation stations for a duration of 1.0 second (step of 0.1 s) exhibited significant variations: non-Newtonian fluid type under physiological flow had shown more biofilm-antagonistic responses, where a peak wall pressure of the orders of 10 4 Pa with peak shear rate of the orders of 4000-5000 s -1 for core channel regions were observed with micro-scale deformations suggesting suitability of non-Newtonian fluid suitability under physiological flow for elimination of biofilm growth onto the scaffolds. The findings marked the important observation of fluid rheology associated with solids that might interplay in controlling and preventing the implant-associated infections in patients.
- 11 May 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (21)
Computational Investigation of Non-Newtonian Physiological Flow and Slip Boundary Effects on Biofilm-Inhibitory TPMS Scaffold Design
This study presents a computational rheology approach to assess the impact of scaffold shape and fluid dynamics on biofilm suppression. CFD simulations used COMSOL Multiphysics 5.6, which included laminar flow, solid mechanics, and FSI modules, and the studies were conducted on 12 scaffold architectures, comprising solid scaffolds (10% porosity) and TPMSbased IWP scaffolds (50% and 70% porosity). Six inlet velocity profiles sinusoidal and physiological were utilized to evaluate axial velocity, pressure, shear rate, stress, strain tensor, strain principal, deformation gradient and displacement gradient under slip wall boundary conditions for both Newtonian and non-Newtonian fluid types. Data from 12 observation stations for a duration of 1.0 second (step of 0.1 s) exhibited significant variations: non-Newtonian fluid type under physiological flow had shown more biofilm-antagonistic responses, where a peak wall pressure of the orders of 10 4 Pa with peak shear rate of the orders of 4000-5000 s -1 for core channel regions were observed with micro-scale deformations suggesting suitability of non-Newtonian fluid suitability under physiological flow for elimination of biofilm growth onto the scaffolds. The findings marked the important observation of fluid rheology associated with solids that might interplay in controlling and preventing the implant-associated infections in patients.
- 1 June 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (6)
Analysis of rheological parameter variations in uterine arteries before and after cryptic pregnancy
Cryptic pregnancy, characterized by the absence of typical gestational indicators, poses significant diagnostic challenges. Current diagnostic tests based on biochemical markers such as Human Chorionic Gonadotropin cannot detect such pregnancies because of hormonal dysregulation. The objective of the present study was to evaluate the variation in different rheological parameters—Pressure, Shear rate, Axial velocity—in the uterine arteries using the Computational Fluid Dynamics (CFD) using the COMSOL. The CFD analysis was performed on the total 24 geometries generated from the two structures: S1, before cryptic pregnancy and S2, after cryptic pregnancy. The CFD studies were performed in no slip condition of the wall and viscosity of flowing fluid (equivalent to blood), which were considered both Newtonian and non-Newtonian in the presence of sinusoidal and pulsatile flow. The different rheological parameters were observed on points P1–P5 at the T cycle. Result indicated that non-Newtonian flows exhibited dominant oscillatory patterns in shear rate, pressure, and axial velocity, especially at points like P2 and P4. Newtonian flows showed linear smooth trends, while non-Newtonian fluids showed complex rheological behavior, indicating their potential role in cryptic pregnancy detection. It had been observed that for the structures S124, S125, and S126, pressure value initially rises at point P1, which is further increased from P2 to P5 (2 × 106 Pa) within the time duration from T/3 to T/2 s. Newtonian models are useful for a simplified description, ignoring non-Newtonian effects that may result in incorrect predictions of flow behavior, which can undermine the efficiency and reliability of fluid transport processes in artificial circulation devices, microfluidic systems, and industrial processes. This research identifies the importance of rheological analysis in providing an alternative, noninvasive early detection test, which improves diagnostic accuracy and maternal health outcomes.
- 1 June 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (6)
Analysis of rheological parameter variations in uterine arteries before and after cryptic pregnancy
Cryptic pregnancy, characterized by the absence of typical gestational indicators, poses significant diagnostic challenges. Current diagnostic tests based on biochemical markers such as Human Chorionic Gonadotropin cannot detect such pregnancies because of hormonal dysregulation. The objective of the present study was to evaluate the variation in different rheological parameters—Pressure, Shear rate, Axial velocity—in the uterine arteries using the Computational Fluid Dynamics (CFD) using the COMSOL. The CFD analysis was performed on the total 24 geometries generated from the two structures: S1, before cryptic pregnancy and S2, after cryptic pregnancy. The CFD studies were performed in no slip condition of the wall and viscosity of flowing fluid (equivalent to blood), which were considered both Newtonian and non-Newtonian in the presence of sinusoidal and pulsatile flow. The different rheological parameters were observed on points P1–P5 at the T cycle. Result indicated that non-Newtonian flows exhibited dominant oscillatory patterns in shear rate, pressure, and axial velocity, especially at points like P2 and P4. Newtonian flows showed linear smooth trends, while non-Newtonian fluids showed complex rheological behavior, indicating their potential role in cryptic pregnancy detection. It had been observed that for the structures S124, S125, and S126, pressure value initially rises at point P1, which is further increased from P2 to P5 (2 × 106 Pa) within the time duration from T/3 to T/2 s. Newtonian models are useful for a simplified description, ignoring non-Newtonian effects that may result in incorrect predictions of flow behavior, which can undermine the efficiency and reliability of fluid transport processes in artificial circulation devices, microfluidic systems, and industrial processes. This research identifies the importance of rheological analysis in providing an alternative, noninvasive early detection test, which improves diagnostic accuracy and maternal health outcomes.
- Open Access
- 31 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (4) , 344
Validation and Estimation of Obesity-Induced Intervertebral Disc Degeneration through Subject-Specific Finite Element Modelling of Functional Spinal Units
(1) Background: Intervertebral disc degeneration has been linked to obesity; its potential mechanical effects on the intervertebral disc remain unknown. This study aimed to develop and validate a patient-specific model of L3–L4 vertebrae and then use the model to estimate the impact of increasing body weight on disc degeneration. (2) Methods: A three-dimensional model of the functional spinal unit of L3–L4 vertebrae and its components were developed and validated. Validation was achieved by comparing the range of motions (RoM) and intradiscal pressures with the previous literature. Subsequently, the validated model was loaded according to the body mass index and estimated stress, deformation, and RoM to assess disc degeneration. (3) Results: During validation, L3–L4 RoM and intradiscal pressures: flexion 5.17° and 1.04 MPa, extension 1.54° and 0.22 MPa, lateral bending 3.36° and 0.54 MPa, axial rotation 1.14° and 0.52 MPa, respectively. When investigating the impact of weight on disc degeneration, escalating from normal weight to obesity reveals an increased RoM, by 3.44% during flexion, 22.7% during extension, 29.71% during lateral bending, and 33.2% during axial rotation, respectively. Also, stress and disc deformation elevated with increasing weight across all RoM. (4) Conclusions: The predicted mechanical responses of the developed model closely matched the validation dataset. The validated model predicts disc degeneration under increased weight and could lay the foundation for future recommendations aimed at identifying predictors of lower back pain due to disc degeneration.
- 31 March 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (4) , 344
Open AccessValidation and Estimation of Obesity-Induced Intervertebral Disc Degeneration through Subject-Specific Finite Element Modelling of Functional Spinal Units
(1) Background: Intervertebral disc degeneration has been linked to obesity; its potential mechanical effects on the intervertebral disc remain unknown. This study aimed to develop and validate a patient-specific model of L3–L4 vertebrae and then use the model to estimate the impact of increasing body weight on disc degeneration. (2) Methods: A three-dimensional model of the functional spinal unit of L3–L4 vertebrae and its components were developed and validated. Validation was achieved by comparing the range of motions (RoM) and intradiscal pressures with the previous literature. Subsequently, the validated model was loaded according to the body mass index and estimated stress, deformation, and RoM to assess disc degeneration. (3) Results: During validation, L3–L4 RoM and intradiscal pressures: flexion 5.17° and 1.04 MPa, extension 1.54° and 0.22 MPa, lateral bending 3.36° and 0.54 MPa, axial rotation 1.14° and 0.52 MPa, respectively. When investigating the impact of weight on disc degeneration, escalating from normal weight to obesity reveals an increased RoM, by 3.44% during flexion, 22.7% during extension, 29.71% during lateral bending, and 33.2% during axial rotation, respectively. Also, stress and disc deformation elevated with increasing weight across all RoM. (4) Conclusions: The predicted mechanical responses of the developed model closely matched the validation dataset. The validated model predicts disc degeneration under increased weight and could lay the foundation for future recommendations aimed at identifying predictors of lower back pain due to disc degeneration.
- 1 January 2024
- Published by Begell House Inc. Publishers in International Journal for Multiscale Computational Engineering
- Vol. 22 (6) , 15-29
A COMPARATIVE BIOMECHANICAL ANALYSIS OF POSTERIOR LUMBAR INTERBODY FUSION CONSTRUCTS WITH FOUR ESTABLISHED SCENARIOS
Posterior lumbar interbody fusion (PLIF) is a common technique for decompressing the diseased spinal segment. This study aims to compare the biomechanical effects of four PLIF scenarios. A finite element model of the L3-L4 segment is used to simulate decompression with different scenarios: S1 (PEEK cage), S2 (PEEK cage with graft), S3 (Titanium cage), and S4 (Titanium cage with graft). Range of motion, stress, and micromotion are measured under various loading conditions. S2 demonstrates sufficient stability, reduced micromotion, and lower stress on the adjacent parts of the lumbar segment, indicating that S2 may be a preferred option for PLIF.
- 1 January 2024
- Published by Begell House Inc. Publishers in International Journal for Multiscale Computational Engineering
- Vol. 22 (6) , 15-29
A COMPARATIVE BIOMECHANICAL ANALYSIS OF POSTERIOR LUMBAR INTERBODY FUSION CONSTRUCTS WITH FOUR ESTABLISHED SCENARIOS
Posterior lumbar interbody fusion (PLIF) is a common technique for decompressing the diseased spinal segment. This study aims to compare the biomechanical effects of four PLIF scenarios. A finite element model of the L3-L4 segment is used to simulate decompression with different scenarios: S1 (PEEK cage), S2 (PEEK cage with graft), S3 (Titanium cage), and S4 (Titanium cage with graft). Range of motion, stress, and micromotion are measured under various loading conditions. S2 demonstrates sufficient stability, reduced micromotion, and lower stress on the adjacent parts of the lumbar segment, indicating that S2 may be a preferred option for PLIF.
- 9 September 2022
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 32 (7) , 1-13
Mechanical Property Analysis of Triply Periodic Minimal Surface Inspired Porous Scaffold for Bone Applications: A Compromise between Desired Mechanical Strength and Additive Manufacturability
- 9 September 2022
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 32 (7) , 1-13
Mechanical Property Analysis of Triply Periodic Minimal Surface Inspired Porous Scaffold for Bone Applications: A Compromise between Desired Mechanical Strength and Additive Manufacturability
- 14 February 2022
- Published by Taylor & Francis in Advances in Materials and Processing Technologies
- Vol. 8 (sup4) , 2122-2141
Recent trends in bio-materials and advances in design of spinal fusion implants
Metals, ceramics and polymers are the three broad categories of bio-materials utilised in spinal fusion devices. A bio-material with good tensile strength, bio-compatible, minimal imaging artefacts, stiffness, young’s modulus near the bone and fatigue strength is suitable for a spinal fusion implant. Unfortunately, no material excels all desirable properties, such as high strength, similar elastic modulus to bone and excellent host tissue response. As a result, the materials used for such types of implants are identified by the unique criteria that are most significant and necessary for the implants specific applications. This may result in various components of a single implant being made of multi-materials to better fit its intended purpose. In fusion surgeries, implants and its fixation methods have advanced significantly to meet the demands of surgeons, who continue to increase their understanding of the bio-mechanical principles of spinal stability and help improve the production of novel implant design. The review focused on recent advancements and trends in the design of fusion devices and the use of bio-materials in their component assemblies. This review will help researchers to enhance and optimise the design and material properties for future spine implantology research.
- 14 February 2022
- Published by Taylor & Francis in Advances in Materials and Processing Technologies
- Vol. 8 (sup4) , 2122-2141
Recent trends in bio-materials and advances in design of spinal fusion implants
Metals, ceramics and polymers are the three broad categories of bio-materials utilised in spinal fusion devices. A bio-material with good tensile strength, bio-compatible, minimal imaging artefacts, stiffness, young’s modulus near the bone and fatigue strength is suitable for a spinal fusion implant. Unfortunately, no material excels all desirable properties, such as high strength, similar elastic modulus to bone and excellent host tissue response. As a result, the materials used for such types of implants are identified by the unique criteria that are most significant and necessary for the implants specific applications. This may result in various components of a single implant being made of multi-materials to better fit its intended purpose. In fusion surgeries, implants and its fixation methods have advanced significantly to meet the demands of surgeons, who continue to increase their understanding of the bio-mechanical principles of spinal stability and help improve the production of novel implant design. The review focused on recent advancements and trends in the design of fusion devices and the use of bio-materials in their component assemblies. This review will help researchers to enhance and optimise the design and material properties for future spine implantology research.