Luana Marinho Gonçalves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luana Marinho Gonçalves has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Hochhegger
Department of Radiology, University of Florida, Gainesville, USA
1 shared publication - Carlos Eduardo Poli-De-Figueiredo
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
1 shared publication - Gabriele Carra Forte
Department of Radiology Pontificia Universidade Catolica do Rio Grande do Sul Porto Alegre Brazil
1 shared publication - Lucas Lobraico Libermann
Pontifical Catholic University of Rio Grande do Sul
1 shared publication - Tiago Garcia Holz
Pontificia Universidade Católica do Rio Grande do Sul (PUCRS), Brazil
1 shared publication
Latest Publications
- Open Access
- 1 February 2022
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 55 (1) , 19-23
Shear wave elastography and Doppler ultrasound in kidney transplant recipients
Objective: To evaluate the association between shear wave elastography parameters and arterial resistance in kidney transplant recipients. Materials and Methods: This was a prospective cross-sectional study involving consecutive adult kidney transplant recipients. All patients underwent color Doppler to evaluate the resistive index (RI) and ultrasound shear wave elastography for the quantification of renal allograft stiffness. Results: We evaluated 55 patients, of whom 9 (16.4%) had an RI defined as abnormal (≥ 0.79) and 46 (83.6%) had an RI defined as normal (< 0.79). The mean age was higher in the abnormal RI group than in the normal RI group (68.0 ± 8.6 years vs. 42.6 ± 14.1 years; p < 0.001), as was the mean shear wave velocity (2.6 ± 0.4 m/s vs. 2.2 ± 0.4 m/s; p = 0.013). Multivariate analysis identified two independent predictors of arterial resistance: age (OR = 1.169; 95% CI: 1.056 to 1.294; p = 0.003) and shear wave velocity (OR = 17.1; 95% CI: 1.137 to 257.83; p = 0.040). Conclusion: We observed an association between rigidity in the cortex of the transplanted kidney, as evaluated by shear wave elastography, and arterial resistance, as evaluated by color Doppler, in kidney transplant recipients.
- 1 February 2022
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 55 (1) , 19-23
Open AccessShear wave elastography and Doppler ultrasound in kidney transplant recipients
Objective: To evaluate the association between shear wave elastography parameters and arterial resistance in kidney transplant recipients. Materials and Methods: This was a prospective cross-sectional study involving consecutive adult kidney transplant recipients. All patients underwent color Doppler to evaluate the resistive index (RI) and ultrasound shear wave elastography for the quantification of renal allograft stiffness. Results: We evaluated 55 patients, of whom 9 (16.4%) had an RI defined as abnormal (≥ 0.79) and 46 (83.6%) had an RI defined as normal (< 0.79). The mean age was higher in the abnormal RI group than in the normal RI group (68.0 ± 8.6 years vs. 42.6 ± 14.1 years; p < 0.001), as was the mean shear wave velocity (2.6 ± 0.4 m/s vs. 2.2 ± 0.4 m/s; p = 0.013). Multivariate analysis identified two independent predictors of arterial resistance: age (OR = 1.169; 95% CI: 1.056 to 1.294; p = 0.003) and shear wave velocity (OR = 17.1; 95% CI: 1.137 to 257.83; p = 0.040). Conclusion: We observed an association between rigidity in the cortex of the transplanted kidney, as evaluated by shear wave elastography, and arterial resistance, as evaluated by color Doppler, in kidney transplant recipients.