Erçin Samunahmetoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Erçin Samunahmetoğlu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Hakan Kurt
Ankara Üniversitesi
2 shared publications - Sevilay Karahan
Department of Biostatistics, Faculty of Medicine, Hacettepe University , Ankara
2 shared publications - Arzum Yilmaz
Faculty of Dentistry Oral and Maxillofacial Surgery Department Gazi University Ankara Türkiye
1 shared publication - Elif Polat Balkan
ANKARA ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
1 shared publication - Gül Sönmez
Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey
1 shared publication - Hakan Eren
Çanakkale Onsekiz Mart University, Faculty of Dentistry
1 shared publication
Latest Publications
- Open Access
- 21 August 2026
- Published by Wiley in Journal of Prosthodontics
Influence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis
Purpose: This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant‐supported prosthetic systems under varying bone conditions using finite element analysis. Materials and Methods: Four three‐dimensional (3D) finite element models were developed based on two different anatomical conditions representing Zygoma Anatomy Guided Approach (ZAGA) Type 1 and Type 3. In each ZAGA type, two implant configurations were created by positioning zygomatic implants in different regions: lateral incisor–first molar and first premolar–first molar. All models were subjected to vertical and oblique loading conditions. Stress distribution in the peri‐implant bone, implants, abutments, and metal framework, as well as implant displacement, was analyzed. Results: Under vertical loading conditions, Models 2 and 4 demonstrated lower stress values and more balanced load distribution, whereas Models 1 and 3 exhibited higher stress concentrations. In contrast, under oblique loading conditions, Models 1 and 3 showed more favorable stress values compared to Models 2 and 4. Implant displacement values were generally higher in Models 2 and 4. Within the limitations of the present finite element analysis, overall biomechanical response patterns were broadly comparable between the ZAGA Type 1 and Type 3 conditions. Conclusion: Implant configuration appeared to influence the biomechanical behavior of quad zygomatic implant systems under the tested loading conditions. Models 1 and 3 generally showed a more favorable response under oblique loading, whereas the corresponding models in ZAGA Type 1 and Type 3 exhibited broadly comparable biomechanical patterns.
- 21 August 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessInfluence of implant configuration on stress distribution in quad zygoma implant systems: A finite element analysis
Purpose: This study aimed to evaluate the effect of different zygomatic implant configurations on the biomechanical behavior of implant‐supported prosthetic systems under varying bone conditions using finite element analysis. Materials and Methods: Four three‐dimensional (3D) finite element models were developed based on two different anatomical conditions representing Zygoma Anatomy Guided Approach (ZAGA) Type 1 and Type 3. In each ZAGA type, two implant configurations were created by positioning zygomatic implants in different regions: lateral incisor–first molar and first premolar–first molar. All models were subjected to vertical and oblique loading conditions. Stress distribution in the peri‐implant bone, implants, abutments, and metal framework, as well as implant displacement, was analyzed. Results: Under vertical loading conditions, Models 2 and 4 demonstrated lower stress values and more balanced load distribution, whereas Models 1 and 3 exhibited higher stress concentrations. In contrast, under oblique loading conditions, Models 1 and 3 showed more favorable stress values compared to Models 2 and 4. Implant displacement values were generally higher in Models 2 and 4. Within the limitations of the present finite element analysis, overall biomechanical response patterns were broadly comparable between the ZAGA Type 1 and Type 3 conditions. Conclusion: Implant configuration appeared to influence the biomechanical behavior of quad zygomatic implant systems under the tested loading conditions. Models 1 and 3 generally showed a more favorable response under oblique loading, whereas the corresponding models in ZAGA Type 1 and Type 3 exhibited broadly comparable biomechanical patterns.
- 31 August 2024
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 51 (2) , 67-73
Application of Fractal Analysis in Detecting Trabecular Bone Characteristics Around Mandibular Impacted Third Molars on Dental Panoramic Radiographs
Purpose: Surgical extraction of third molars can be difficult for many reasons, including increased bone density, which causes bone structures to lose their elastic properties. The aim of this study is to compare the trabecular structure around the impacted mandibular third molar(M3M) and the normal alveolar trabecular pattern using the fractal analysis method. Materials and Methods: Panoramic images of 47 patients were included in the study. ROI1 is the area between the distal root of the second molar and the mesial of the third molar tooth. On the other hand, ROI2 was selected between the distal root of the first molar tooth and the mesial root of the second molar tooth. Fractal Dimension (FD) and Bone Marrow Dimension analyzes were applied to the selected ROIs using the ImageJ software. Results: The mean FD values of 47 patients were found to be 1.135 for ROI1 and 1.105 for ROI2, respectively (p=0,078).The mean Bone Marrow Dimension values were found to be 1.591 for ROI1 and 1.587 for ROI2(p=0.731). There was no significant difference in FD and Bone Marrow Dimension analysis when ROI1 and ROI2 were compared. It is very important to know the pattern of trabecular structure before surgical procedure on M3M. The bone density around the impacted M3M may be higher than the healthy alveolar bone, however, the fact that males have denser bone than females should not be ignored during the operation. Conclusion: The method of FD analysis can be useful for evaluating the trabecular structure of impacted M3M. Key words: fractal dimension; bone structure; panoramic imaging; impacted tooth; third molars
- 31 August 2024
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 51 (2) , 67-73
Application of Fractal Analysis in Detecting Trabecular Bone Characteristics Around Mandibular Impacted Third Molars on Dental Panoramic Radiographs
Purpose: Surgical extraction of third molars can be difficult for many reasons, including increased bone density, which causes bone structures to lose their elastic properties. The aim of this study is to compare the trabecular structure around the impacted mandibular third molar(M3M) and the normal alveolar trabecular pattern using the fractal analysis method. Materials and Methods: Panoramic images of 47 patients were included in the study. ROI1 is the area between the distal root of the second molar and the mesial of the third molar tooth. On the other hand, ROI2 was selected between the distal root of the first molar tooth and the mesial root of the second molar tooth. Fractal Dimension (FD) and Bone Marrow Dimension analyzes were applied to the selected ROIs using the ImageJ software. Results: The mean FD values of 47 patients were found to be 1.135 for ROI1 and 1.105 for ROI2, respectively (p=0,078).The mean Bone Marrow Dimension values were found to be 1.591 for ROI1 and 1.587 for ROI2(p=0.731). There was no significant difference in FD and Bone Marrow Dimension analysis when ROI1 and ROI2 were compared. It is very important to know the pattern of trabecular structure before surgical procedure on M3M. The bone density around the impacted M3M may be higher than the healthy alveolar bone, however, the fact that males have denser bone than females should not be ignored during the operation. Conclusion: The method of FD analysis can be useful for evaluating the trabecular structure of impacted M3M. Key words: fractal dimension; bone structure; panoramic imaging; impacted tooth; third molars
- 30 April 2022
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 49 (1) , 15-19
The Prevalence of Radix Paramolaris and Entomolaris in Mandibular Molar Teeth: A Retrospective Study
Objective: The aim of this study is to analyze the frequency of radix paramolaris (RP) and radix entomolaris (RE) in the first and second molars using cone beam computed tomography (CBCT). Materials and Methods: The CBCT images of a total of 400 patients at the ages of 14 to 66 were included in the study. On the images that were included, two maxillofacial radiologists simultaneously examined the presence of radix paramolaris and radix entomolaris by using axial CBCT cross-sections from the pulpal chamber towards the apical. Results: At least one RE or RP was observed in 36 of the 400 patients (9%). A total of 20 RPs (1.25%) were observed, including 2 bilateral and 16 unilateral cases. A total of 38 REs (2.38%) were observed, including 11 bilateral and 16 unilateral cases. There was at least one RE or RP in 16 of the 149 male patients (10.7%) and in 20 of the 251 female patients (8%). Conclusion: Consequently, while the prevalence and types of third root variations differ between different populations, RE is seen more frequently in mandibular first molar teeth, and RP is seen more frequently in mandibular second molar teeth. No significant relationship could be found between sex and the prevalence of third root variations in mandibular molar teeth images included in this study. No significant difference was found between the right and left sides as the localizations of RP and RE in terms of prevalence. Keywords: Radix entomolaris; Radix paramolaris; Root canal morphology; Cone-beam CT; Mandibular molar
- 30 April 2022
- Published by Ankara University in European Annals of Dental Sciences
- Vol. 49 (1) , 15-19
The Prevalence of Radix Paramolaris and Entomolaris in Mandibular Molar Teeth: A Retrospective Study
Objective: The aim of this study is to analyze the frequency of radix paramolaris (RP) and radix entomolaris (RE) in the first and second molars using cone beam computed tomography (CBCT). Materials and Methods: The CBCT images of a total of 400 patients at the ages of 14 to 66 were included in the study. On the images that were included, two maxillofacial radiologists simultaneously examined the presence of radix paramolaris and radix entomolaris by using axial CBCT cross-sections from the pulpal chamber towards the apical. Results: At least one RE or RP was observed in 36 of the 400 patients (9%). A total of 20 RPs (1.25%) were observed, including 2 bilateral and 16 unilateral cases. A total of 38 REs (2.38%) were observed, including 11 bilateral and 16 unilateral cases. There was at least one RE or RP in 16 of the 149 male patients (10.7%) and in 20 of the 251 female patients (8%). Conclusion: Consequently, while the prevalence and types of third root variations differ between different populations, RE is seen more frequently in mandibular first molar teeth, and RP is seen more frequently in mandibular second molar teeth. No significant relationship could be found between sex and the prevalence of third root variations in mandibular molar teeth images included in this study. No significant difference was found between the right and left sides as the localizations of RP and RE in terms of prevalence. Keywords: Radix entomolaris; Radix paramolaris; Root canal morphology; Cone-beam CT; Mandibular molar
- Open Access
- 1 January 2022
- Published by XMLink in Imaging Science in Dentistry
- Vol. 52 (1) , 93-101
Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality
Kamburoğlu K, et al. Imaging Sci Dent. 2022 Feb;52:e8. https://doi.org/10.5624/isd.20210241
- 1 January 2022
- Published by XMLink in Imaging Science in Dentistry
- Vol. 52 (1) , 93-101
Open AccessClinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality
Kamburoğlu K, et al. Imaging Sci Dent. 2022 Feb;52:e8. https://doi.org/10.5624/isd.20210241