WGWeihua Gong

Weihua Gong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weihua Gong has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Compact and Low-Power-Consumption CO Sensor Using a QCL with Intermittent Scanning Technique

    by Qinduan Zhang, Jie Hu, Yubin Wei, Binkai Li, Guancheng Liu, Tingting Zhang, Zhaowei Wang, Weihua Gong, Tongyu Liu

    A compact and low-power-consumption gas sensor using a quantum cascade laser (QCL) emitting at 4.6 μm for measurement of carbon monoxide (CO) was proposed and experimentally demonstrated. A compact sensor structure with a physical dimension of 14 × 10 × 6.5 cm3 was designed. A new intermittent scanning technique was used to drive the QCL to reduce the power consumption of the system. In this technique, the power consumption of the sensor is as low as 1.08 W, which is about 75% lower than the conventional direct absorption technology. The stability of the CO sensor was demonstrated by continuously monitoring CO concentration for more than 1 h. In the concentration range of 10 ppm to 500 ppm, the CO sensor exhibited a satisfactory linear response (R-square = 0.9998). With an integration time of 202 s, the minimum detection limit was increased to 4.85 ppb, based on an Allan deviation analysis.


  • Open Access

    SNR Enhancement of Direct Absorption Spectroscopy Utilizing an Improved Particle Swarm Algorithm

    by Lin Zhang, Yanfang Li, Yubin Wei, Zhaowei Wang, Tingting Zhang, Weihua Gong, Qinduan Zhang

    A noise elimination method based on an improved particle swarm algorithm is applied to direct absorption spectroscopy. The algorithm combines the theory of spectral line shape to calculate a fitness function according to the original spectra. Comparing the particles and the fitness function to calculate the updating direction, and position of particles, the iterative update finally finds the optimal solution. The algorithm is applied to direct absorption spectroscopy to measure methane; compared with the signal without algorithm processing, the signal-to-noise ratio (SNR) is improved by 4.17 times, and the minimum detection limit in the experiment is 15.3 ppb. R2 = 0.9999 is calculated in the calibration experiment, and the error is less than 0.1 ppm in the repeatability experiment of constant methane at 2 ppm concentration.