Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammad Mahbub Rabbani has a total of 117 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep eutectic solvents in biomedical applications: A mini review

    by Ejaj Tarif, Md. Sarowar Hossain, Gourisankar Roymahapatra, Mohammad Mahbub Rabbani


  • Band degeneracy in W-doped BaTiO3: An insight from theoretical approach with experiment

    by Tusar Saha, Sarowar Hossain, Jyotish Chandra Debnath, Humayra Ferdous, Angkita Mistry Tama, Mohammad Mahbub Rabbani, Sagar Dutta, Masud Parvez


  • Open Access

    Characterization and Comparison of DSSCs Fabricated with Black Natural Dyes Extracted from Jamun, Black Plum, and Blackberry

    by Ahmed Sikder, William Ghann, Rafsun Jani, Tohidul Islam, Saquib Ahmed, Mohammed M. Rahman, Abdul Majed Patwary, Mohsin Kazi, Jahidul Islam, Faisal I. Chowdhury, et al.

    In this report, natural dyes extracted from three different, black-colored fruits were used as photosensitizers for the construction of dye-sensitized solar cells (DSSCs). The natural dyes were extracted from the dark-colored peels of jamun (also known as Indian black plum), black plum, and blackberry fruit. These natural dyes contain polyphenolic compounds—most prominently anthocyanins—which interact strongly with titanium dioxide (TiO2) semiconductors and accordingly enhance the efficiency of DSSCs. The natural dyes extracted from the various fruits were characterized utilizing UV-Vis and fluorescence spectroscopy. The interaction between the dyes and TiO2 was monitored with FTIR and Raman spectroscopy. The fabricated DSSCs were characterized via current–voltage measurements and electrochemical impedance analysis. DSSCs fabricated with jamun produced the highest efficiency of 1.09% with a short-circuit current of 7.84 mA/cm2, an open-circuit voltage of 0.45 V, and a fill factor of 0.31. The efficiencies of the DSSCs from black plum and blackberry were 0.55% and 0.38%, respectively. The flow of charge occurring at the interfaces between the natural dye and the TiO2 layers were investigated using electrochemical impedance spectroscopy (EIS). To the best of our knowledge, this study is the first to directly compare three distinct types of black DSSCs. Computation analysis was also carried out utilizing SCAPS-1D software (version 3.3.07), which revealed how the type of defects in the devices impacts their performance.


  • Open Access

    A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference

    by Gokul Chandra Biswas, Swapnila Choudhury, Mohammad Mahbub Rabbani, Jagotamoy Das

    Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.


  • Open Access

    Sensitivity Control of Hydroquinone and Catechol at Poly(Brilliant Cresyl Blue)-Modified GCE by Varying Activation Conditions of the GCE: An Experimental and Computational Study

    by Sharifa Faraezi, Sharif Khan, Ferzana Zaman Monira, Abdullah Al Mamun, Tania Akter, Mohammad Al Mamun, Mohammad Mahbub Rabbani, Jamal Uddin, A. J. Saleh Ahammad

    The poly(brilliant cresyl blue) (PBCB)-modified activated glassy carbon electrode (AGCE) shows the catalytic activity toward the oxidation of hydroquinone (HQ) and catechol (CT). The modified electrode can also separate the oxidation peaks of HQ and CT in their mixture, which is not possible with bare GCE. These properties of the modified electrode can be utilized to fabricate an electrochemical sensor for sensitive and simultaneous detection of HQ and CT. In this study, an attempt is made to control the sensitivity of the modified electrodes. This can be accomplished by simply changing the activation condition of the GCE during electropolymerization. GCE can be activated via one-step (applying only oxidation potential) and two-step (applying both oxidation and reduction potential) processes. When we change the activation condition from onestep to twosteps, a clear enhancement inpeak currents of HQ and CT is observed. This helps us to fabricate a highly sensitive electrochemical sensor for the simultaneous detection of HQ and CT. The molecular dynamics (MD) simulation is carried out to explain the experimental data. The MD simulations provide the insight adsorption phenomena to clarify the reasons for higher signals of CT over HQ due to having meta-position –OH group in its structure.


  • Open Access

    Cobalt Oxide Nanorod-Modified GCE as Sensitive Electrodes for Simultaneous Detection of Hydroquinone and Catechol

    by Nasrin Sultana, Sanjay Datta Shawon, S. M. Abu Nayem, Mahedi Hasan, Tamanna Islam, Syed Shaheen Shah, Mohammad Mahbub Rabbani, Abdul Aziz, A. J. Saleh Ahammad

    An electrochemical sensor based on a cobalt oxide nanorod (Co3O4NR) modified glassy carbon electrode (GCE) (Co3O4NR-GCE) was prepared for simultaneous and selective determination of hydroquinone (HQ) and catechol (CT). Surface morphology and crystallinity of Co3O4NR were investigated employing field emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD) analysis. The structure (16 nm) of the Co3O4 nanorod was observed in the FESEM image. A sharp peak pattern in the XRD survey revealed the following crystal planes in Co3O4NR material: (111), (220), (311), (222), (400), (422), (511), and (440). Electrochemical characterization of modified Co3O4NR-GCE was carried out performing cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Selective and simultaneous detection of HQ and CT was carried out by performing CV and differential pulse voltammetry (DPV) analysis. In both studies, modified Co3O4NR-GCE showed well defined oxidation and reduction peaks for HQ and CT with enhanced peak current, and the oxidation peaks for HQ and CT were observed at 0.152 V and 0.254 V, respectively, in the CV analysis. Scan rate and pH variation analysis were performed to evaluate different kinetic parameters, including charge transfer coefficient (α = 0.56 for HQ and 0.66 for CT), heterogeneous charge transfer rate constant (ks = 56 for HQ and 72 for CT), and the number of electrons involved in HQ and CT oxidation. Quantitative analysis of HQ and CT was studied by observing the current response of DPV analysis with respect to concentration variation. Here, the detection limit was calculated as 0.2 µM for HQ with a linear concentration range of 5–200 µM, and 0.4 µM for CT with a linear concentration range of 5–150 µM. The practical applicability of the proposed sensor was investigated using sample solutions prepared in tap water. The reported sensor showed impressive selectivity towards HQ and CT in the presence of common interferents.


  • Dye-sensitized solar cell with plasmonic gold nanoparticles modified photoanode

    by Daiyaan Kabir, Taseen Forhad, William Ghann, Balvin Richards, Mohammed M. Rahman, Nizam Uddin, Refat J. Rakib, Mohammad Hossain Shariare, Faisal I. Chowdhury, Mohammad Mahbub Rabbani, et al.


  • Open Access

    Effect on human health by residues of commonly used pesticides in vegetables cultivation

    by Farzana Khalil, Maliyat Tarannum Maruf, Mohammad Tariqul Islam, Mohammad Mahbub Rabbani, S. Mosaddeq Ahmed

    People in Bangladesh are over scared for toxicity of vegetables & fruits because of the educational level of the farmers is not up to the mark, farmers apply pesticides randomly on agricultural fields without maintaining pre-harvest intervals and dose. The aim of this work was to study dissipation pattern of some pesticides in some vegetables kept at room temperature which represent market condition and to identify and quantify pesticides applied on some vegetables. By interviewing the farmers three commonly used pesticides; cypermethrin, chlorpyrifos and fenvalerate were sprayed in the farmer’s fields of the western part of Bangladesh. Samples were extracted by QuEChERS method, cleaned-up by adsorption chromatography technique, and analyzed by GC-ECD. Recoveries were found to be between 87-107% with RSD lower than 10% at three spiking levels. Matrix matched calibration curves were linear for all the analytes with r2 ≥ 0.99. LODs were found to be 0.01 mg/kg for cypermethrin and 0.002 mg/kg for both of fenvalerate and chlorpyrifos. The samples of same cultivar’s variety were purchased from the markets of Savar, Mymemsingh and Cumilla. Our finding showed only the presence of cypermethrin in tomato but the values were below MRL and no pesticide residue was found in eggplant.

  • Silicone-enriched surface of immersed polyurethane-POSS antifouling coating

    by Mohammad Mizanur Rahman, Hasan Zahir, Bashirul Haq, A. Madhan Kumar, Eyasin Arafat, Mohammad Mahbub Rabbani

    A series of waterborne polyurethane-polyhedral oligomeric silsesquioxane (WBPU-POSS) dispersions were synthesized. Different POSS contents were used to evaluate the effect of POSS content on silicone enrichment under both nonimmersed and immersed conditions. The impact of silicone enrichment under immersed conditions on antifouling properties was also evaluated. The structure of the WBPU-POSS coating was identified by FT-IR and(29)Si-NMR. X-ray photoelectron spectroscopy (XPS) analysis confirmed a silicone-enriched surface with a certain composition of the WBPU-POSS coating under both nonimmersed and immersed conditions. The mechanical properties, hydrophilicity and hydrolytic degradation of the coating all varied with POSS content. The long-term antifouling performance of immersed coatings depends on surface silicone enrichment, which was found to be above 0.0021 mole POSS content in WBPU-POSS coatings.