Stefan Yordanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Yordanov has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Marshall Davies
Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
6 shared publications - Mark Reinhard Kotter
Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
6 shared publications Alexis Joannides
Academic Division of Neurosurgery, Addenbrookes' Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
3 shared publications- Alvaro Yanez Touzet
Department of Neurosurgery, King's College Hospital, London, UK; Department of Basic and Clinical Neurosciences, Maurice Wohl Clinical Neuroscience Institute, Institute of Psychiatry, Psychology and Neuroscience (IoPPN), King's College London, London, UK; School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
3 shared publications - Angelos Georgiou Kolias
Division of Neurosurgery, Addenbrooke’s Hospital, Cambridge, UK
3 shared publications Benjamin Davies
Department of Neurosurgery, Cambridge University, Cambridge, UK
3 shared publications
Latest Publications
- Open Access
- 24 May 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e56889
Reliability of a Smartphone App to Objectively Monitor Performance Outcomes in Degenerative Cervical Myelopathy: Observational Study
Background: Developing new clinical measures for degenerative cervical myelopathy (DCM) is an AO Spine RECODE-DCM Research, an international and multi-stakeholder partnership, priority. Difficulties in detecting DCM and its changes cause diagnostic and treatment delays in clinical settings and heightened costs in clinical trials due to elevated recruitment targets. Digital outcome measures can tackle these challenges due to their ability to measure disease remotely, repeatedly, and more economically. Objective: The aim of this study is to assess the reliability of the MoveMed battery of performance outcome measures. Methods: A prospective observational study in decentralized secondary care was performed in England, United Kingdom. The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intraclass correlation (ICC) of agreement . The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the SE of the mean (SEM) of agreement and the smallest detectable change (SDC) of agreement . Criteria from the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (ie, ICC of agreement ≥0.7) and risk of bias. Disease stability was controlled using 2 minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (p-mJOA) score, namely, MCID ≤1 point and MCID ≤2 points. Results: In total, 7 adults aged 59.5 (SD 12.4) years who live with DCM and possess an approved smartphone participated in the study. All tests demonstrated moderate to excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC of agreement values were 0.84-0.94 in the fast tap test, 0.89-0.95 in the hold test, 0.95 in the typing test, and 0.98 in the stand and walk test. SEM of agreement values were ±1 tap, ±1%-3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC of agreement values were ±3 taps, ±4%-7% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. In the MCID ≤2 group, ICC of agreement values were 0.61-0.91, 0.75-0.77, 0.98, and 0.62, respectively; SEM of agreement values were ±1 tap, ±2%-4% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively; and SDC of agreement values were ±3-7 taps, ±7%-10% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. Furthermore, the fast tap, hold, and typing tests obtained sufficient ratings (ICC of agreement ≥0.7) in both MCID ≤1 and MCID ≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. Conclusions: The criteria from COSMIN provide “very good” quality evidence of the reliability of the MoveMed tests in an adult population living with DCM.
- 24 May 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e56889
Open AccessReliability of a Smartphone App to Objectively Monitor Performance Outcomes in Degenerative Cervical Myelopathy: Observational Study
Background: Developing new clinical measures for degenerative cervical myelopathy (DCM) is an AO Spine RECODE-DCM Research, an international and multi-stakeholder partnership, priority. Difficulties in detecting DCM and its changes cause diagnostic and treatment delays in clinical settings and heightened costs in clinical trials due to elevated recruitment targets. Digital outcome measures can tackle these challenges due to their ability to measure disease remotely, repeatedly, and more economically. Objective: The aim of this study is to assess the reliability of the MoveMed battery of performance outcome measures. Methods: A prospective observational study in decentralized secondary care was performed in England, United Kingdom. The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intraclass correlation (ICC) of agreement . The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the SE of the mean (SEM) of agreement and the smallest detectable change (SDC) of agreement . Criteria from the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (ie, ICC of agreement ≥0.7) and risk of bias. Disease stability was controlled using 2 minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (p-mJOA) score, namely, MCID ≤1 point and MCID ≤2 points. Results: In total, 7 adults aged 59.5 (SD 12.4) years who live with DCM and possess an approved smartphone participated in the study. All tests demonstrated moderate to excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC of agreement values were 0.84-0.94 in the fast tap test, 0.89-0.95 in the hold test, 0.95 in the typing test, and 0.98 in the stand and walk test. SEM of agreement values were ±1 tap, ±1%-3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC of agreement values were ±3 taps, ±4%-7% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. In the MCID ≤2 group, ICC of agreement values were 0.61-0.91, 0.75-0.77, 0.98, and 0.62, respectively; SEM of agreement values were ±1 tap, ±2%-4% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively; and SDC of agreement values were ±3-7 taps, ±7%-10% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. Furthermore, the fast tap, hold, and typing tests obtained sufficient ratings (ICC of agreement ≥0.7) in both MCID ≤1 and MCID ≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. Conclusions: The criteria from COSMIN provide “very good” quality evidence of the reliability of the MoveMed tests in an adult population living with DCM.
- Open Access
- 14 February 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8, e54194
Measurement of Head Circumference Using a Smartphone: Feasibility Cohort Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Accurate head circumference (HC) measurement is essential when assessing neonates and infants. Tape measure HC measurements are prone to errors, particularly when performed by parents/guardians, due to individual differences in head shape, hair style and texture, subject cooperation, and examiner techniques, including tape measure placement and tautness. There is, therefore, the need for a more reliable method. Objective: The primary objective of this study was to evaluate the validity, reliability, and consistency of HC app measurement compared to the current standard of practice, serving as a proof-of-concept for use by health care professionals. Methods: We recruited infants attending the neurosurgery clinic, and parents/guardians were approached and consented to participate in the study. Along with the standard head circumference measurement, measurements were taken with the head circumference app (HC app) developed in-house, and we also collected baseline medical history and characteristics. For the statistical analysis, we used RStudio (version 4.1.1). In summary, we analyzed covariance and intraclass correlation coefficient (ICC) to compare the measurement's within-rater and interrater reliability. The F test was used to analyze the variance between measurements and the Bland-Altman agreement, t test, and correlation coefficients were used to compare the tape measurement to the measures taken by the HC app. We also used nonvalidated questionnaires to explore parental or guardians’ experiences, assess their views on app utility, and collect feedback. Results: The total number of recruited patients was 37. Comparison between the app measurements and the measurements with a tape measure showed poor reliability (ICC=0.177) and wide within-app variations (ICC=0.341). The agreement between the measurements done by parents/guardians and the tape measurements done by the researcher was good (ICC=0.901). Parental/guardian feedback was overall very positive, with most of the parents/guardians reporting that the app was easy to use (n=31, 84%) and that they are happy to use the app in an unsupervised setting, provided that they are assured of the measurement quality. Conclusions: We developed this project as a proof-of-concept study, and as such, the app has shown great potential to be used both in a clinical setting and by parents/guardians in their own homes.
- 14 February 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8, e54194
Open AccessMeasurement of Head Circumference Using a Smartphone: Feasibility Cohort Study
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Accurate head circumference (HC) measurement is essential when assessing neonates and infants. Tape measure HC measurements are prone to errors, particularly when performed by parents/guardians, due to individual differences in head shape, hair style and texture, subject cooperation, and examiner techniques, including tape measure placement and tautness. There is, therefore, the need for a more reliable method. Objective: The primary objective of this study was to evaluate the validity, reliability, and consistency of HC app measurement compared to the current standard of practice, serving as a proof-of-concept for use by health care professionals. Methods: We recruited infants attending the neurosurgery clinic, and parents/guardians were approached and consented to participate in the study. Along with the standard head circumference measurement, measurements were taken with the head circumference app (HC app) developed in-house, and we also collected baseline medical history and characteristics. For the statistical analysis, we used RStudio (version 4.1.1). In summary, we analyzed covariance and intraclass correlation coefficient (ICC) to compare the measurement's within-rater and interrater reliability. The F test was used to analyze the variance between measurements and the Bland-Altman agreement, t test, and correlation coefficients were used to compare the tape measurement to the measures taken by the HC app. We also used nonvalidated questionnaires to explore parental or guardians’ experiences, assess their views on app utility, and collect feedback. Results: The total number of recruited patients was 37. Comparison between the app measurements and the measurements with a tape measure showed poor reliability (ICC=0.177) and wide within-app variations (ICC=0.341). The agreement between the measurements done by parents/guardians and the tape measurements done by the researcher was good (ICC=0.901). Parental/guardian feedback was overall very positive, with most of the parents/guardians reporting that the app was easy to use (n=31, 84%) and that they are happy to use the app in an unsupervised setting, provided that they are assured of the measurement quality. Conclusions: We developed this project as a proof-of-concept study, and as such, the app has shown great potential to be used both in a clinical setting and by parents/guardians in their own homes.
- Open Access
Reliability of a smartphone app to objectively monitor performance outcomes in degenerative cervical myelopathy: an observational study
Objectives: To assess the reliability of the MoveMed battery of performance outcome measures. Design: Prospective observational study. Setting: Decentralised secondary care in England, United Kingdom. Participants: Seven adults aged 59.5 (SD 12.4) who live with degenerative cervical myelopathy (DCM) and possess an approved smartphone. Primary and secondary outcome measures: The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intra-class correlation of agreement (ICC agreement ). The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the standard error of agreement of the mean (SEM agreement ) and the smallest detectable change of agreement (SDC agreement ). Criteria from the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (i.e., ICC agreement ≥ 0.7) and risk of bias. Disease stability was controlled for using two minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (P-mJOA): namely, MCID ≤1 point and MCID ≤2 points. Results: All tests demonstrated moderate-to-excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC agreement values ranged from: 0.84–0.94 in the Fast Tap Test, 0.89–0.95 in the Hold Test, 0.95 in the Typing Test, and 0.98 in the Stand and Walk Test. SEM agreement values ranged from ±1 tap, ±1–3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC agreement values were ±3 taps, ±4–7% stability score points, ±0.2 keys per second, and ±27 steps per minute. In the MCID ≤2 group, ICC agreement values ranged from: 0.61–0.91, 0.75–0.77, 0.98, and 0.62, respectively; SEM agreement values from: ±1 tap, ±2–4% stability score points, ±0.06 keys per second, and ±10 steps per minute; and SDC agreement values from: ±3–7 taps, ±7–10% stability score points, ±0.2 keys per second, and ±27 steps per minute. Furthermore, the Fast Tap, Hold, and Typing Tests obtained sufficient ratings (ICC agreement ≥ 0.7) in both MCID≤1 and MCID≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. Overall, ‘very good’ quality evidence of sufficient reliability was found for the MoveMed battery in DCM. Conclusions: Criteria from COSMIN provide ‘very good’ quality evidence of the reliability of the MoveMed tests in an adult population living with DCM. Strengths and limitations of this study: Criteria from the COSMIN manual support the reliability of MoveMed’s battery of performance outcome measures. Criteria from the COSMIN manual rate the methodological quality of the evidence at ‘very good’. Self-reported outcome measures and data elements were used in a decentralised secondary setting. Primary and secondary outcomes were used to assess reliability. Study design and analyses were performed by individuals formally trained in clinimetrics.
Open AccessReliability of a smartphone app to objectively monitor performance outcomes in degenerative cervical myelopathy: an observational study
Objectives: To assess the reliability of the MoveMed battery of performance outcome measures. Design: Prospective observational study. Setting: Decentralised secondary care in England, United Kingdom. Participants: Seven adults aged 59.5 (SD 12.4) who live with degenerative cervical myelopathy (DCM) and possess an approved smartphone. Primary and secondary outcome measures: The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intra-class correlation of agreement (ICC agreement ). The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the standard error of agreement of the mean (SEM agreement ) and the smallest detectable change of agreement (SDC agreement ). Criteria from the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (i.e., ICC agreement ≥ 0.7) and risk of bias. Disease stability was controlled for using two minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (P-mJOA): namely, MCID ≤1 point and MCID ≤2 points. Results: All tests demonstrated moderate-to-excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC agreement values ranged from: 0.84–0.94 in the Fast Tap Test, 0.89–0.95 in the Hold Test, 0.95 in the Typing Test, and 0.98 in the Stand and Walk Test. SEM agreement values ranged from ±1 tap, ±1–3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC agreement values were ±3 taps, ±4–7% stability score points, ±0.2 keys per second, and ±27 steps per minute. In the MCID ≤2 group, ICC agreement values ranged from: 0.61–0.91, 0.75–0.77, 0.98, and 0.62, respectively; SEM agreement values from: ±1 tap, ±2–4% stability score points, ±0.06 keys per second, and ±10 steps per minute; and SDC agreement values from: ±3–7 taps, ±7–10% stability score points, ±0.2 keys per second, and ±27 steps per minute. Furthermore, the Fast Tap, Hold, and Typing Tests obtained sufficient ratings (ICC agreement ≥ 0.7) in both MCID≤1 and MCID≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. Overall, ‘very good’ quality evidence of sufficient reliability was found for the MoveMed battery in DCM. Conclusions: Criteria from COSMIN provide ‘very good’ quality evidence of the reliability of the MoveMed tests in an adult population living with DCM. Strengths and limitations of this study: Criteria from the COSMIN manual support the reliability of MoveMed’s battery of performance outcome measures. Criteria from the COSMIN manual rate the methodological quality of the evidence at ‘very good’. Self-reported outcome measures and data elements were used in a decentralised secondary setting. Primary and secondary outcomes were used to assess reliability. Study design and analyses were performed by individuals formally trained in clinimetrics.
- Open Access
- 10 February 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Reliability of a Smartphone App to Objectively Monitor Performance Outcomes in Degenerative Cervical Myelopathy: Observational Study (Preprint)
BACKGROUND Developing new clinical measures for degenerative cervical myelopathy (DCM) is an AO Spine RECODE-DCM Research, an international and multi-stakeholder partnership, priority. Difficulties in detecting DCM and its changes cause diagnostic and treatment delays in clinical settings and heightened costs in clinical trials due to elevated recruitment targets. Digital outcome measures can tackle these challenges due to their ability to measure disease remotely, repeatedly, and more economically. OBJECTIVE The aim of this study is to assess the reliability of the MoveMed battery of performance outcome measures. METHODS A prospective observational study in decentralized secondary care was performed in England, United Kingdom. The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intraclass correlation (ICC) of agreement . The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the SE of the mean (SEM) of agreement and the smallest detectable change (SDC) of agreement . Criteria from the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (ie, ICC of agreement ≥0.7) and risk of bias. Disease stability was controlled using 2 minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (p-mJOA) score, namely, MCID ≤1 point and MCID ≤2 points. RESULTS In total, 7 adults aged 59.5 (SD 12.4) years who live with DCM and possess an approved smartphone participated in the study. All tests demonstrated moderate to excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC of agreement values were 0.84-0.94 in the fast tap test, 0.89-0.95 in the hold test, 0.95 in the typing test, and 0.98 in the stand and walk test. SEM of agreement values were ±1 tap, ±1%-3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC of agreement values were ±3 taps, ±4%-7% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. In the MCID ≤2 group, ICC of agreement values were 0.61-0.91, 0.75-0.77, 0.98, and 0.62, respectively; SEM of agreement values were ±1 tap, ±2%-4% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively; and SDC of agreement values were ±3-7 taps, ±7%-10% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. Furthermore, the fast tap, hold, and typing tests obtained sufficient ratings (ICC of agreement ≥0.7) in both MCID ≤1 and MCID ≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. CONCLUSIONS The criteria from COSMIN provide “very good” quality evidence of the reliability of the MoveMed tests in an adult population living with DCM.
- 10 February 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessReliability of a Smartphone App to Objectively Monitor Performance Outcomes in Degenerative Cervical Myelopathy: Observational Study (Preprint)
BACKGROUND Developing new clinical measures for degenerative cervical myelopathy (DCM) is an AO Spine RECODE-DCM Research, an international and multi-stakeholder partnership, priority. Difficulties in detecting DCM and its changes cause diagnostic and treatment delays in clinical settings and heightened costs in clinical trials due to elevated recruitment targets. Digital outcome measures can tackle these challenges due to their ability to measure disease remotely, repeatedly, and more economically. OBJECTIVE The aim of this study is to assess the reliability of the MoveMed battery of performance outcome measures. METHODS A prospective observational study in decentralized secondary care was performed in England, United Kingdom. The primary outcome was to determine the test-retest reliability of the MoveMed performance outcomes using the intraclass correlation (ICC) of agreement . The secondary outcome was to determine the measurement error of the MoveMed performance outcomes using both the SE of the mean (SEM) of agreement and the smallest detectable change (SDC) of agreement . Criteria from the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) manual were used to determine adequate reliability (ie, ICC of agreement ≥0.7) and risk of bias. Disease stability was controlled using 2 minimum clinically important difference (MCID) thresholds obtained from the literature on the patient-derived modified Japanese Orthopaedic Association (p-mJOA) score, namely, MCID ≤1 point and MCID ≤2 points. RESULTS In total, 7 adults aged 59.5 (SD 12.4) years who live with DCM and possess an approved smartphone participated in the study. All tests demonstrated moderate to excellent test-retest coefficients and low measurement errors. In the MCID ≤1 group, ICC of agreement values were 0.84-0.94 in the fast tap test, 0.89-0.95 in the hold test, 0.95 in the typing test, and 0.98 in the stand and walk test. SEM of agreement values were ±1 tap, ±1%-3% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively. SDC of agreement values were ±3 taps, ±4%-7% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. In the MCID ≤2 group, ICC of agreement values were 0.61-0.91, 0.75-0.77, 0.98, and 0.62, respectively; SEM of agreement values were ±1 tap, ±2%-4% stability score points, ±0.06 keys per second, and ±10 steps per minute, respectively; and SDC of agreement values were ±3-7 taps, ±7%-10% stability score points, ±0.2 keys per second, and ±27 steps per minute, respectively. Furthermore, the fast tap, hold, and typing tests obtained sufficient ratings (ICC of agreement ≥0.7) in both MCID ≤1 and MCID ≤2 groups. No risk of bias factors from the COSMIN Risk of Bias checklist were recorded. CONCLUSIONS The criteria from COSMIN provide “very good” quality evidence of the reliability of the MoveMed tests in an adult population living with DCM.
- Open Access
- 1 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Measurement of Head Circumference Using a Smartphone: Feasibility Cohort Study (Preprint)
BACKGROUND Accurate head circumference (HC) measurement is essential when assessing neonates and infants. Tape measure HC measurements are prone to errors, particularly when performed by parents/guardians, due to individual differences in head shape, hair style and texture, subject cooperation, and examiner techniques, including tape measure placement and tautness. There is, therefore, the need for a more reliable method. OBJECTIVE The primary objective of this study was to evaluate the validity, reliability, and consistency of HC app measurement compared to the current standard of practice, serving as a proof-of-concept for use by health care professionals. METHODS We recruited infants attending the neurosurgery clinic, and parents/guardians were approached and consented to participate in the study. Along with the standard head circumference measurement, measurements were taken with the head circumference app (HC app) developed in-house, and we also collected baseline medical history and characteristics. For the statistical analysis, we used RStudio (version 4.1.1). In summary, we analyzed covariance and intraclass correlation coefficient (ICC) to compare the measurement's within-rater and interrater reliability. The F test was used to analyze the variance between measurements and the Bland-Altman agreement, t test, and correlation coefficients were used to compare the tape measurement to the measures taken by the HC app. We also used nonvalidated questionnaires to explore parental or guardians’ experiences, assess their views on app utility, and collect feedback. RESULTS The total number of recruited patients was 37. Comparison between the app measurements and the measurements with a tape measure showed poor reliability (ICC=0.177) and wide within-app variations (ICC=0.341). The agreement between the measurements done by parents/guardians and the tape measurements done by the researcher was good (ICC=0.901). Parental/guardian feedback was overall very positive, with most of the parents/guardians reporting that the app was easy to use (n=31, 84%) and that they are happy to use the app in an unsupervised setting, provided that they are assured of the measurement quality. CONCLUSIONS We developed this project as a proof-of-concept study, and as such, the app has shown great potential to be used both in a clinical setting and by parents/guardians in their own homes.
- 1 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMeasurement of Head Circumference Using a Smartphone: Feasibility Cohort Study (Preprint)
BACKGROUND Accurate head circumference (HC) measurement is essential when assessing neonates and infants. Tape measure HC measurements are prone to errors, particularly when performed by parents/guardians, due to individual differences in head shape, hair style and texture, subject cooperation, and examiner techniques, including tape measure placement and tautness. There is, therefore, the need for a more reliable method. OBJECTIVE The primary objective of this study was to evaluate the validity, reliability, and consistency of HC app measurement compared to the current standard of practice, serving as a proof-of-concept for use by health care professionals. METHODS We recruited infants attending the neurosurgery clinic, and parents/guardians were approached and consented to participate in the study. Along with the standard head circumference measurement, measurements were taken with the head circumference app (HC app) developed in-house, and we also collected baseline medical history and characteristics. For the statistical analysis, we used RStudio (version 4.1.1). In summary, we analyzed covariance and intraclass correlation coefficient (ICC) to compare the measurement's within-rater and interrater reliability. The F test was used to analyze the variance between measurements and the Bland-Altman agreement, t test, and correlation coefficients were used to compare the tape measurement to the measures taken by the HC app. We also used nonvalidated questionnaires to explore parental or guardians’ experiences, assess their views on app utility, and collect feedback. RESULTS The total number of recruited patients was 37. Comparison between the app measurements and the measurements with a tape measure showed poor reliability (ICC=0.177) and wide within-app variations (ICC=0.341). The agreement between the measurements done by parents/guardians and the tape measurements done by the researcher was good (ICC=0.901). Parental/guardian feedback was overall very positive, with most of the parents/guardians reporting that the app was easy to use (n=31, 84%) and that they are happy to use the app in an unsupervised setting, provided that they are assured of the measurement quality. CONCLUSIONS We developed this project as a proof-of-concept study, and as such, the app has shown great potential to be used both in a clinical setting and by parents/guardians in their own homes.
- Open Access
- 26 September 2023
- Published by Elsevier in Brain and Spine
- Vol. 3, 101943
Update on the Global Neurotrauma Outcomes Study Spine: An international, multi-centre, prospective cohort study on the injury profile, management and outcomes of traumatic spinal injury
- 26 September 2023
- Published by Elsevier in Brain and Spine
- Vol. 3, 101943
Open AccessUpdate on the Global Neurotrauma Outcomes Study Spine: An international, multi-centre, prospective cohort study on the injury profile, management and outcomes of traumatic spinal injury
- Open Access
- 12 September 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7, e48321
Factors Influencing Surgical Decision-Making in the Posterior Laminectomy With Fixation for Degenerative Cervical Myelopathy (POLYFIX-DCM) Trial: Survey Study
Background: Degenerative cervical myelopathy (DCM) is estimated to affect 2% of the adult population. DCM occurs when degenerative processes cause compression and injure the spinal cord. Surgery to remove the stress caused by the compression of the spinal cord is the mainstay of treatment, with a range of techniques in use. Although various factors are described to inform the selection of these techniques, there needs to be more consensus and limited comparative evidence. Objective: The main objective of this survey was to explore the variation of practice and decision-making, with a focus on laminectomy versus laminectomy and fusion in posterior surgery of the cervical spine. We present the results of a survey conducted among the principal investigators (PIs) of the National Institute for Health and Care Research (NIHR) randomized controlled trial on posterior laminectomy with fixation for degenerative cervical myelopathy (POLYFIX-DCM). Methods: A series of 7 cases were shared with 24 PIs using SurveyMonkey. Each case consisted of a midsagittal T2-weighted magnetic resonance imaging and lateral cervical x-rays in flexion and extension. Surgeons were asked if their preferred approach was anterior or posterior. If posterior, they were asked whether they preferred to instrument and whether they had the equipoise to randomize in the NIHR POLYFIX-DCM trial. Variability in decision-making was then explored using factors reported to inform decision-making, such as alignment, location of compression, number of levels operated, presence of mobile spondylolisthesis, and patient age. Results: The majority of PIs (16/30, 53%) completed the survey. Overall, PIs favored a posterior approach (12/16, 75%) with instrumentation (75/112, average 66%) and would randomize (67/112, average 62%) most cases. Factors reported to inform decision-making poorly explained variability in responses in both univariate testing and with a multivariate model (R2=0.1). Only surgeon experience of more than 5 years and orthopedic specialty training background were significant predictors, both associated with an anterior approach (odds ratio [OR] 1.255; P=.02 and OR 1.344; P=.007, respectively) and fusion for posterior procedures (OR 0.628; P<.001 and OR 1.344; P<.001, respectively). Surgeon experience also significantly affected the openness to randomize, with those with more than 5 years of experience less likely to randomize (OR –0.68; P<.001). Conclusions: In this representative sample of spine surgeons participating in the POLYFIX-DCM trial as investigators, there is no consensus on surgical strategy, including the role of instrumented fusion following posterior decompression. Overall, this study supports the view that there appears to be a clinical equipoise, and conceptually, a randomized controlled trial appears feasible, which sets the scene for the NIHR POLYFIX-DCM trial.
- 12 September 2023
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 7, e48321
Open AccessFactors Influencing Surgical Decision-Making in the Posterior Laminectomy With Fixation for Degenerative Cervical Myelopathy (POLYFIX-DCM) Trial: Survey Study
Background: Degenerative cervical myelopathy (DCM) is estimated to affect 2% of the adult population. DCM occurs when degenerative processes cause compression and injure the spinal cord. Surgery to remove the stress caused by the compression of the spinal cord is the mainstay of treatment, with a range of techniques in use. Although various factors are described to inform the selection of these techniques, there needs to be more consensus and limited comparative evidence. Objective: The main objective of this survey was to explore the variation of practice and decision-making, with a focus on laminectomy versus laminectomy and fusion in posterior surgery of the cervical spine. We present the results of a survey conducted among the principal investigators (PIs) of the National Institute for Health and Care Research (NIHR) randomized controlled trial on posterior laminectomy with fixation for degenerative cervical myelopathy (POLYFIX-DCM). Methods: A series of 7 cases were shared with 24 PIs using SurveyMonkey. Each case consisted of a midsagittal T2-weighted magnetic resonance imaging and lateral cervical x-rays in flexion and extension. Surgeons were asked if their preferred approach was anterior or posterior. If posterior, they were asked whether they preferred to instrument and whether they had the equipoise to randomize in the NIHR POLYFIX-DCM trial. Variability in decision-making was then explored using factors reported to inform decision-making, such as alignment, location of compression, number of levels operated, presence of mobile spondylolisthesis, and patient age. Results: The majority of PIs (16/30, 53%) completed the survey. Overall, PIs favored a posterior approach (12/16, 75%) with instrumentation (75/112, average 66%) and would randomize (67/112, average 62%) most cases. Factors reported to inform decision-making poorly explained variability in responses in both univariate testing and with a multivariate model (R2=0.1). Only surgeon experience of more than 5 years and orthopedic specialty training background were significant predictors, both associated with an anterior approach (odds ratio [OR] 1.255; P=.02 and OR 1.344; P=.007, respectively) and fusion for posterior procedures (OR 0.628; P<.001 and OR 1.344; P<.001, respectively). Surgeon experience also significantly affected the openness to randomize, with those with more than 5 years of experience less likely to randomize (OR –0.68; P<.001). Conclusions: In this representative sample of spine surgeons participating in the POLYFIX-DCM trial as investigators, there is no consensus on surgical strategy, including the role of instrumented fusion following posterior decompression. Overall, this study supports the view that there appears to be a clinical equipoise, and conceptually, a randomized controlled trial appears feasible, which sets the scene for the NIHR POLYFIX-DCM trial.
- Open Access
- 19 April 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Factors Influencing Surgical Decision-Making in the Posterior Laminectomy With Fixation for Degenerative Cervical Myelopathy (POLYFIX-DCM) Trial: Survey Study (Preprint)
BACKGROUND Degenerative cervical myelopathy (DCM) is estimated to affect 2% of the adult population. DCM occurs when degenerative processes cause compression and injure the spinal cord. Surgery to remove the stress caused by the compression of the spinal cord is the mainstay of treatment, with a range of techniques in use. Although various factors are described to inform the selection of these techniques, there needs to be more consensus and limited comparative evidence. OBJECTIVE The main objective of this survey was to explore the variation of practice and decision-making, with a focus on laminectomy versus laminectomy and fusion in posterior surgery of the cervical spine. We present the results of a survey conducted among the principal investigators (PIs) of the National Institute for Health and Care Research (NIHR) randomized controlled trial on posterior laminectomy with fixation for degenerative cervical myelopathy (POLYFIX-DCM). METHODS A series of 7 cases were shared with 24 PIs using SurveyMonkey. Each case consisted of a midsagittal T2-weighted magnetic resonance imaging and lateral cervical x-rays in flexion and extension. Surgeons were asked if their preferred approach was anterior or posterior. If posterior, they were asked whether they preferred to instrument and whether they had the equipoise to randomize in the NIHR POLYFIX-DCM trial. Variability in decision-making was then explored using factors reported to inform decision-making, such as alignment, location of compression, number of levels operated, presence of mobile spondylolisthesis, and patient age. RESULTS The majority of PIs (16/30, 53%) completed the survey. Overall, PIs favored a posterior approach (12/16, 75%) with instrumentation (75/112, average 66%) and would randomize (67/112, average 62%) most cases. Factors reported to inform decision-making poorly explained variability in responses in both univariate testing and with a multivariate model (R2=0.1). Only surgeon experience of more than 5 years and orthopedic specialty training background were significant predictors, both associated with an anterior approach (odds ratio [OR] 1.255; P=.02 and OR 1.344; P=.007, respectively) and fusion for posterior procedures (OR 0.628; P<.001 and OR 1.344; P<.001, respectively). Surgeon experience also significantly affected the openness to randomize, with those with more than 5 years of experience less likely to randomize (OR –0.68; P<.001). CONCLUSIONS In this representative sample of spine surgeons participating in the POLYFIX-DCM trial as investigators, there is no consensus on surgical strategy, including the role of instrumented fusion following posterior decompression. Overall, this study supports the view that there appears to be a clinical equipoise, and conceptually, a randomized controlled trial appears feasible, which sets the scene for the NIHR POLYFIX-DCM trial.
- 19 April 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessFactors Influencing Surgical Decision-Making in the Posterior Laminectomy With Fixation for Degenerative Cervical Myelopathy (POLYFIX-DCM) Trial: Survey Study (Preprint)
BACKGROUND Degenerative cervical myelopathy (DCM) is estimated to affect 2% of the adult population. DCM occurs when degenerative processes cause compression and injure the spinal cord. Surgery to remove the stress caused by the compression of the spinal cord is the mainstay of treatment, with a range of techniques in use. Although various factors are described to inform the selection of these techniques, there needs to be more consensus and limited comparative evidence. OBJECTIVE The main objective of this survey was to explore the variation of practice and decision-making, with a focus on laminectomy versus laminectomy and fusion in posterior surgery of the cervical spine. We present the results of a survey conducted among the principal investigators (PIs) of the National Institute for Health and Care Research (NIHR) randomized controlled trial on posterior laminectomy with fixation for degenerative cervical myelopathy (POLYFIX-DCM). METHODS A series of 7 cases were shared with 24 PIs using SurveyMonkey. Each case consisted of a midsagittal T2-weighted magnetic resonance imaging and lateral cervical x-rays in flexion and extension. Surgeons were asked if their preferred approach was anterior or posterior. If posterior, they were asked whether they preferred to instrument and whether they had the equipoise to randomize in the NIHR POLYFIX-DCM trial. Variability in decision-making was then explored using factors reported to inform decision-making, such as alignment, location of compression, number of levels operated, presence of mobile spondylolisthesis, and patient age. RESULTS The majority of PIs (16/30, 53%) completed the survey. Overall, PIs favored a posterior approach (12/16, 75%) with instrumentation (75/112, average 66%) and would randomize (67/112, average 62%) most cases. Factors reported to inform decision-making poorly explained variability in responses in both univariate testing and with a multivariate model (R2=0.1). Only surgeon experience of more than 5 years and orthopedic specialty training background were significant predictors, both associated with an anterior approach (odds ratio [OR] 1.255; P=.02 and OR 1.344; P=.007, respectively) and fusion for posterior procedures (OR 0.628; P<.001 and OR 1.344; P<.001, respectively). Surgeon experience also significantly affected the openness to randomize, with those with more than 5 years of experience less likely to randomize (OR –0.68; P<.001). CONCLUSIONS In this representative sample of spine surgeons participating in the POLYFIX-DCM trial as investigators, there is no consensus on surgical strategy, including the role of instrumented fusion following posterior decompression. Overall, this study supports the view that there appears to be a clinical equipoise, and conceptually, a randomized controlled trial appears feasible, which sets the scene for the NIHR POLYFIX-DCM trial.
- 24 March 2023
- Published by Elsevier in The Surgeon
- Vol. 21 (5) , e271-e278
Assessing the accuracy of the International Classification of Disease (ICD) framework in the identification of patients with chronic subdural haematoma from hospital records
- 24 March 2023
- Published by Elsevier in The Surgeon
- Vol. 21 (5) , e271-e278
Assessing the accuracy of the International Classification of Disease (ICD) framework in the identification of patients with chronic subdural haematoma from hospital records
- Open Access
Targeting patient recovery priorities in degenerative cervical myelopathy: design and rationale for the RECEDE-Myelopathy trial—study protocol
Introduction Degenerative cervical myelopathy (DCM) is a common and disabling condition of symptomatic cervical spinal cord compression secondary to degenerative changes in spinal structures leading to a mechanical stress injury of the spinal cord. RECEDE-Myelopathy aims to test the disease-modulating activity of the phosphodiesterase 3/phosphodiesterase 4 inhibitor Ibudilast as an adjuvant to surgical decompression in DCM. Methods and analysis RECEDE-Myelopathy is a multicentre, double-blind, randomised, placebo-controlled trial. Participants will be randomised to receive either 60–100 mg Ibudilast or placebo starting within 10 weeks prior to surgery and continuing for 24 weeks after surgery for a maximum of 34 weeks. Adults with DCM, who have a modified Japanese Orthopaedic Association (mJOA) score 8–14 inclusive and are scheduled for their first decompressive surgery are eligible for inclusion. The coprimary endpoints are pain measured on a visual analogue scale and physical function measured by the mJOA score at 6 months after surgery. Clinical assessments will be undertaken preoperatively, postoperatively and 3, 6 and 12 months after surgery. We hypothesise that adjuvant therapy with Ibudilast leads to a meaningful and additional improvement in either pain or function, as compared with standard routine care. Study design Clinical trial protocol V.2.2 October 2020. Ethics and dissemination Ethical approval has been obtained from HRA—Wales.The results will be presented at an international and national scientific conferences and in a peer-reviewed journals. Trial registration number ISRCTN Number: ISRCTN16682024.
Open AccessTargeting patient recovery priorities in degenerative cervical myelopathy: design and rationale for the RECEDE-Myelopathy trial—study protocol
Introduction Degenerative cervical myelopathy (DCM) is a common and disabling condition of symptomatic cervical spinal cord compression secondary to degenerative changes in spinal structures leading to a mechanical stress injury of the spinal cord. RECEDE-Myelopathy aims to test the disease-modulating activity of the phosphodiesterase 3/phosphodiesterase 4 inhibitor Ibudilast as an adjuvant to surgical decompression in DCM. Methods and analysis RECEDE-Myelopathy is a multicentre, double-blind, randomised, placebo-controlled trial. Participants will be randomised to receive either 60–100 mg Ibudilast or placebo starting within 10 weeks prior to surgery and continuing for 24 weeks after surgery for a maximum of 34 weeks. Adults with DCM, who have a modified Japanese Orthopaedic Association (mJOA) score 8–14 inclusive and are scheduled for their first decompressive surgery are eligible for inclusion. The coprimary endpoints are pain measured on a visual analogue scale and physical function measured by the mJOA score at 6 months after surgery. Clinical assessments will be undertaken preoperatively, postoperatively and 3, 6 and 12 months after surgery. We hypothesise that adjuvant therapy with Ibudilast leads to a meaningful and additional improvement in either pain or function, as compared with standard routine care. Study design Clinical trial protocol V.2.2 October 2020. Ethics and dissemination Ethical approval has been obtained from HRA—Wales.The results will be presented at an international and national scientific conferences and in a peer-reviewed journals. Trial registration number ISRCTN Number: ISRCTN16682024.