Hirofumi Watanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hirofumi Watanabe has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
Satarou Yamaguchi
Chubu University, Kasugai, Aichi 487-8501, Japan
12 shared publicationsMakoto Hamabe
8 shared publicationsNoriko Chikumoto
Chubu University, Kasugai, Aichi 487-8501, Japan
7 shared publications- Daiji Kato
National Institute for Fusion Science
6 shared publications - Jian Sun
Center of Applied Superconductivity and Sustainable Energy Research, Chubu University, Kasugai, Japan
6 shared publications Toshio Kawahara
6 shared publications
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Strain Gauge Measurement of HTS Tape During Short-Circuit Current
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-4
Strain Gauge Measurement of HTS Tape During Short-Circuit Current
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 7700605
Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions
Thermal insulation performance of three different multilayer insulation (MLI) wrapping methods was investigated using a vertical guarded boil-off calorimeter to determine the method that minimizes both the heat leak and the wrapping effort for cryogenic pipes used in superconducting power transmission. The wrapping methods are termed the Swiss-roll type, alternating-seam type, and blanket type. In the Swiss-roll type, a single MLI film is rolled continuously around the liquid nitrogen tank in the calorimeter from the room-temperature side to the cryogenic-temperature side. In the alternating-seam type, MLI films are wrapped layer by layer around the tank, while their seams are placed alternately on opposite sides of the tank. In the blanket type, MLI films are stacked to form a single blanket, which is then wrapped around the tank. Heat leak measurements for these methods indicate that the Swiss-roll type is the most effective, considering both thermal insulation performance and workability. For the Swiss-roll type, the dependence of heat leak on wrapping strength was also investigated using a horizontal guarded boil-off calorimeter by varying the circumferential length of the MLI. The results reveal that as the wrapping became looser, the heat leak decreased significantly until a certain wrapping strength, at which a space clearly formed beneath the tank, was reached. Beyond this wrapping strength, the heat leak remained nearly constant. These findings show that an optimum wrapping strength, which minimizes both the heat leak and wrapping effort, exists in the Swiss-roll type method.
- 11 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 7700605
Thermal Insulation Performance of Multilayer Insulation Under Different Wrapping Conditions
Thermal insulation performance of three different multilayer insulation (MLI) wrapping methods was investigated using a vertical guarded boil-off calorimeter to determine the method that minimizes both the heat leak and the wrapping effort for cryogenic pipes used in superconducting power transmission. The wrapping methods are termed the Swiss-roll type, alternating-seam type, and blanket type. In the Swiss-roll type, a single MLI film is rolled continuously around the liquid nitrogen tank in the calorimeter from the room-temperature side to the cryogenic-temperature side. In the alternating-seam type, MLI films are wrapped layer by layer around the tank, while their seams are placed alternately on opposite sides of the tank. In the blanket type, MLI films are stacked to form a single blanket, which is then wrapped around the tank. Heat leak measurements for these methods indicate that the Swiss-roll type is the most effective, considering both thermal insulation performance and workability. For the Swiss-roll type, the dependence of heat leak on wrapping strength was also investigated using a horizontal guarded boil-off calorimeter by varying the circumferential length of the MLI. The results reveal that as the wrapping became looser, the heat leak decreased significantly until a certain wrapping strength, at which a space clearly formed beneath the tank, was reached. Beyond this wrapping strength, the heat leak remained nearly constant. These findings show that an optimum wrapping strength, which minimizes both the heat leak and wrapping effort, exists in the Swiss-roll type method.
- 15 March 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (11) , 113001
Strong Polarization of a to Transition Arising from Unexpectedly Large Quantum InterferenceWe experimentally show that the transition in emitted in dielectronic recombination of is strongly polarized, although it is an intrinsically unpolarized to transition. This unanticipated polarization is shown to be due to quantum interference with radiative recombination. The interference effect has been studied on an asymmetric resonance profile but has never been studied on polarization. In this Letter, we show that the effect on polarization can arise from a different cross term than that responsible for asymmetry, resulting in unexpectedly large polarization even for a nearly symmetric resonance suggesting a small interference.- 15 March 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (11) , 113001
Strong Polarization of a to Transition Arising from Unexpectedly Large Quantum InterferenceWe experimentally show that the transition in emitted in dielectronic recombination of is strongly polarized, although it is an intrinsically unpolarized to transition. This unanticipated polarization is shown to be due to quantum interference with radiative recombination. The interference effect has been studied on an asymmetric resonance profile but has never been studied on polarization. In this Letter, we show that the effect on polarization can arise from a different cross term than that responsible for asymmetry, resulting in unexpectedly large polarization even for a nearly symmetric resonance suggesting a small interference.- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Electrical Tests and Current Distribution of 500-m-Long DC Superconducting Power Cable
The third cooling test of 500m-long superconducting DC power transmission (SCDC) line constructed in Ishikari city, Hokkaido, was carried out in 2021. The system consists of underground superconducting cable with its electric capacities, 5kA and 100MVA. After completing two cooling tests in 2015, the system remained in a shutdown state. Therefore, this test was the first operation test in six years. The targets of the 3rd cooling test were to confirm the presence/absence of the damage due the Hokkaido Eastern Iburi Earthquake (Mj.6.7) that occurred in and acquire basic data for improving the efficiency of SCDC. Regarding electrical tests, the various tests, such as the capacitance/dielectric loss tangent temperature characteristic measurement, the insulation resistance measurement, the DC withstand voltage test, the rated current loading test were conducted to confirm the soundness of cables and the stability of current loading. One of the characteristic tests conducted this time is the current diversion test. Despite the six-year outage and the massive earthquake that occurred during that time, all tests confirmed that there was no deterioration in the performance of the cable system. In the current diversion test, it was confirmed that the current was evenly distributed to each conductor at the cable joint.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Electrical Tests and Current Distribution of 500-m-Long DC Superconducting Power Cable
The third cooling test of 500m-long superconducting DC power transmission (SCDC) line constructed in Ishikari city, Hokkaido, was carried out in 2021. The system consists of underground superconducting cable with its electric capacities, 5kA and 100MVA. After completing two cooling tests in 2015, the system remained in a shutdown state. Therefore, this test was the first operation test in six years. The targets of the 3rd cooling test were to confirm the presence/absence of the damage due the Hokkaido Eastern Iburi Earthquake (Mj.6.7) that occurred in and acquire basic data for improving the efficiency of SCDC. Regarding electrical tests, the various tests, such as the capacitance/dielectric loss tangent temperature characteristic measurement, the insulation resistance measurement, the DC withstand voltage test, the rated current loading test were conducted to confirm the soundness of cables and the stability of current loading. One of the characteristic tests conducted this time is the current diversion test. Despite the six-year outage and the massive earthquake that occurred during that time, all tests confirmed that there was no deterioration in the performance of the cable system. In the current diversion test, it was confirmed that the current was evenly distributed to each conductor at the cable joint.
- 17 February 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 105 (2) , 023109
Polarization measurement of -shell radiative recombination x rays from highly charged bismuth ionsWe report a polarization measurement of -shell radiative recombination (RR) x rays emitted from He- to F-like bismuth ions. The polarization feature was obtained from the azimuthal angular distribution of the Compton-scattered RR x rays detected with a recently developed state-of-the-art Compton polarimeter installed on an electron beam ion trap. This is one of a very few polarization measurements of RR x rays ever conducted and the first one with bismuth ions. We derived the degree of linear polarization averaged over the charge states to be . By contrast, a theoretical estimation of the degree of polarization with the Flexible Atomic Code (fac) yields . The discrepancy between the observed and theoretical values is likely to be due to the electron correlation effects.- 17 February 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 105 (2) , 023109
Polarization measurement of -shell radiative recombination x rays from highly charged bismuth ionsWe report a polarization measurement of -shell radiative recombination (RR) x rays emitted from He- to F-like bismuth ions. The polarization feature was obtained from the azimuthal angular distribution of the Compton-scattered RR x rays detected with a recently developed state-of-the-art Compton polarimeter installed on an electron beam ion trap. This is one of a very few polarization measurements of RR x rays ever conducted and the first one with bismuth ions. We derived the degree of linear polarization averaged over the charge states to be . By contrast, a theoretical estimation of the degree of polarization with the Flexible Atomic Code (fac) yields . The discrepancy between the observed and theoretical values is likely to be due to the electron correlation effects.- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Gas-Cooled Peltier Current Leads for Compact HTS Devices
As is known, heat losses through current leads essentially determine the economic efficiency of the superconducting systems. Much attention is paid to the design of optimal current leads, but the Wiedemann-Franz law physically limits the benefits of the standard approach. An innovative way to further reduce heat inflow is to use current leads equipped with Peltier thermoelectric elements. These elements are installed in series in the power circuit. Therefore, when the transport current passes through the Peltier element, the thermoelectric effect counteracts the heat flow caused by the temperature gradient in the current lead. Another advantage of this design is that when the circuit is de-energized, the heat loss is reduced due to the low thermal conductivity of the Peltier element. In addition to the theoretical works devoted to the Peltier current leads (PCLs), many experiments confirmed a decrease in heat loss by about 30%. Moreover, PCLs were installed on 500- and 1000-meter HTS power transmission lines in Ishikari (Hokkaido, Japan). An advanced approach involves cooling the current-carrying parts with evaporating nitrogen, which should improve the performance of PCLs. In this work, an experiment on testing gas-cooled PCLs was carried out for the first time. A 30% additional reduction in heat inflow was achieved. At the same time, the dependence of the specific heat loss on the current became flatter, which means an expansion of the range of operating current. In the experiment, the vented gas passed through copper pipes used as conductors. In the future, to increase the efficiency of the gas-cooled PCLs, we plan to improve the heat transfer between the gas flow and the conductor using surface ribbing.
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Gas-Cooled Peltier Current Leads for Compact HTS Devices
As is known, heat losses through current leads essentially determine the economic efficiency of the superconducting systems. Much attention is paid to the design of optimal current leads, but the Wiedemann-Franz law physically limits the benefits of the standard approach. An innovative way to further reduce heat inflow is to use current leads equipped with Peltier thermoelectric elements. These elements are installed in series in the power circuit. Therefore, when the transport current passes through the Peltier element, the thermoelectric effect counteracts the heat flow caused by the temperature gradient in the current lead. Another advantage of this design is that when the circuit is de-energized, the heat loss is reduced due to the low thermal conductivity of the Peltier element. In addition to the theoretical works devoted to the Peltier current leads (PCLs), many experiments confirmed a decrease in heat loss by about 30%. Moreover, PCLs were installed on 500- and 1000-meter HTS power transmission lines in Ishikari (Hokkaido, Japan). An advanced approach involves cooling the current-carrying parts with evaporating nitrogen, which should improve the performance of PCLs. In this work, an experiment on testing gas-cooled PCLs was carried out for the first time. A 30% additional reduction in heat inflow was achieved. At the same time, the dependence of the specific heat loss on the current became flatter, which means an expansion of the range of operating current. In the experiment, the vented gas passed through copper pipes used as conductors. In the future, to increase the efficiency of the gas-cooled PCLs, we plan to improve the heat transfer between the gas flow and the conductor using surface ribbing.
- Open Access
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1293 (1) , 012071
Heat load to the cryogenic system in the 1000 m class superconducting DC power transmission system
Long-term circulation and load cycle tests of the cooling of the 1000 m class superconducting DC power transmission system in Ishikari, Japan were performed to measure the heat load delivered to and the power consumption of the cryogenic system. The average heat load and power consumption during these tests was about 2.5 and 120 kW, respectively. To increase the efficiency of superconducting power transmission systems, the selection and composition of constituent devices of the cooling system should be optimized.
- 1 September 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1293 (1) , 012071
Open AccessHeat load to the cryogenic system in the 1000 m class superconducting DC power transmission system
Long-term circulation and load cycle tests of the cooling of the 1000 m class superconducting DC power transmission system in Ishikari, Japan were performed to measure the heat load delivered to and the power consumption of the cryogenic system. The average heat load and power consumption during these tests was about 2.5 and 120 kW, respectively. To increase the efficiency of superconducting power transmission systems, the selection and composition of constituent devices of the cooling system should be optimized.
- Open Access
- 26 July 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1054 (1) , 012076
Heat leak and pressure drop measurements of the 1000 m class superconducting DC power transmission system in Ishikari
The second cooling test of the 1000 m class superconducting DC power transmission system constructed in Ishikari, Japan, was performed in 2016. In this cooling test, the heat leaks to the low temperature parts and the pressure drops of the liquid nitrogen circulation were measured for each section of the 1000 m system. The heat leaks were measured at different outer pipe temperatures of the cryogenic pipe constituting the transmission line. The total heat leaks of the cable system, composed by the cryogenic pipe and the terminals, were 1.746 and 2.091 kW at the outer pipe temperatures of -2.4 and 17.4 ?C, respectively, which were consistent with those measured in the first cooling test. The heat leak of the cryogenic pipe increased by 30-40 % by the increase of the outer pipe temperature from -2.4 and 17.4 ?C. The pressure drop of the cable system was 42.80 kPa and that of all the system, including the cooling system, was 98.4 kPa at the flow rate of 36.03 L/min. The degradation of the heat leak and pressure drop characteristics were not observed between the first and second cooling tests. Based on the present results, the heat leak, the temperature rise and the pressure drop of 10 km systems were estimated. From this estimation it can be said that the cooling and the circulation of 10 km systems are possible by the present level of technology.
- 26 July 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1054 (1) , 012076
Open AccessHeat leak and pressure drop measurements of the 1000 m class superconducting DC power transmission system in Ishikari
The second cooling test of the 1000 m class superconducting DC power transmission system constructed in Ishikari, Japan, was performed in 2016. In this cooling test, the heat leaks to the low temperature parts and the pressure drops of the liquid nitrogen circulation were measured for each section of the 1000 m system. The heat leaks were measured at different outer pipe temperatures of the cryogenic pipe constituting the transmission line. The total heat leaks of the cable system, composed by the cryogenic pipe and the terminals, were 1.746 and 2.091 kW at the outer pipe temperatures of -2.4 and 17.4 ?C, respectively, which were consistent with those measured in the first cooling test. The heat leak of the cryogenic pipe increased by 30-40 % by the increase of the outer pipe temperature from -2.4 and 17.4 ?C. The pressure drop of the cable system was 42.80 kPa and that of all the system, including the cooling system, was 98.4 kPa at the flow rate of 36.03 L/min. The degradation of the heat leak and pressure drop characteristics were not observed between the first and second cooling tests. Based on the present results, the heat leak, the temperature rise and the pressure drop of 10 km systems were estimated. From this estimation it can be said that the cooling and the circulation of 10 km systems are possible by the present level of technology.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Effective Vacuum Pumping of a Long HTS Power Transmission Line Insulated With Heat Radiation Shield
The energy loss of an HTS power transmission line is highly correlated to the properties of the vacuum thermal insulation. However, the proper evacuation of the very long cryostat requires a number of equally spaced pumping stations. The distance between pumping stations is determined by the pumping speed, the conductance of the cryostat, and the outgassing rate from inner surfaces. In this paper, the pumping of long cryostat is considered in the example of the Ishikari-2 project, Japan. This 1000-m-long HTS dc test facility rated for 50 MW was developed in order to obtain data for the next generation of power transmission lines. The vacuum pumping of the cryogenic pipe is carried out through ports located at the pipe ends. A 475-m-long straight section No. 1 is equipped with a heat radiation shield providing excellent thermal insulation of the cable pipe, whereas 137-m-long U-bend section No. 2 and 379-m-long straight section No. 3 are protected with conventional multilayer insulation. Experimental data allow us to estimate the lower limit of the pumping length. When using a cryogenic pipe with heat radiation shield "as is,'' it is possible to provide the required level of vacuum for a length of about 8 km in the nighttime and about 5 km in the daytime, because outgassing rate correlates well with the temperature of the outer pipe, varied from 4 °C to 41 °C. Therefore, if we take measures against the heating of the outer pipe by direct sunlight, and redesign the radiation shield to improve pipe conductance, the possibility to evacuate 10-km-long cryostat by two vacuum pumps installed at the ends can be achieved.
- 23 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Effective Vacuum Pumping of a Long HTS Power Transmission Line Insulated With Heat Radiation Shield
The energy loss of an HTS power transmission line is highly correlated to the properties of the vacuum thermal insulation. However, the proper evacuation of the very long cryostat requires a number of equally spaced pumping stations. The distance between pumping stations is determined by the pumping speed, the conductance of the cryostat, and the outgassing rate from inner surfaces. In this paper, the pumping of long cryostat is considered in the example of the Ishikari-2 project, Japan. This 1000-m-long HTS dc test facility rated for 50 MW was developed in order to obtain data for the next generation of power transmission lines. The vacuum pumping of the cryogenic pipe is carried out through ports located at the pipe ends. A 475-m-long straight section No. 1 is equipped with a heat radiation shield providing excellent thermal insulation of the cable pipe, whereas 137-m-long U-bend section No. 2 and 379-m-long straight section No. 3 are protected with conventional multilayer insulation. Experimental data allow us to estimate the lower limit of the pumping length. When using a cryogenic pipe with heat radiation shield "as is,'' it is possible to provide the required level of vacuum for a length of about 8 km in the nighttime and about 5 km in the daytime, because outgassing rate correlates well with the temperature of the outer pipe, varied from 4 °C to 41 °C. Therefore, if we take measures against the heating of the outer pipe by direct sunlight, and redesign the radiation shield to improve pipe conductance, the possibility to evacuate 10-km-long cryostat by two vacuum pumps installed at the ends can be achieved.
- 14 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Second Cooling Test of 1000-m Superconducting DC Cable System in Ishikari
1000 m long SC-DC power transmission system was built in Ishikari city, Hokkaido, Japan as a national project ("Ishikari project"). The objectives of the project is to design system and verify the validity of the system for a practical use, and also to obtain the properties required to get a future prospect for longer length cable system such as over 10 km. Until the end of 2016, the cooling test was carried out for two times. Important issues for the cooling test are: release of thermal contraction/expansion force below the rapture strength of the cable, the reliability and life time of the system after several cooling/warming procedure as well as long time operation. For former issue, two techniques, a movable terminal cryostat and the helical core deformation were adopted and these techniques were found to release the axial tension of the cable core effectively. For latter issue, several type of current loading test, such as Ic measurements, continuous rated current test (2.5 kA-3 hrs), load cycling test (1 kA-8 hrs + 0 A-16 hrs for 20 days), etc. were performed All the test showed no deterioration of the electrical properties of cable core after cable laying and thermal cycling process and also the stability of the system.
- 14 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Second Cooling Test of 1000-m Superconducting DC Cable System in Ishikari
1000 m long SC-DC power transmission system was built in Ishikari city, Hokkaido, Japan as a national project ("Ishikari project"). The objectives of the project is to design system and verify the validity of the system for a practical use, and also to obtain the properties required to get a future prospect for longer length cable system such as over 10 km. Until the end of 2016, the cooling test was carried out for two times. Important issues for the cooling test are: release of thermal contraction/expansion force below the rapture strength of the cable, the reliability and life time of the system after several cooling/warming procedure as well as long time operation. For former issue, two techniques, a movable terminal cryostat and the helical core deformation were adopted and these techniques were found to release the axial tension of the cable core effectively. For latter issue, several type of current loading test, such as Ic measurements, continuous rated current test (2.5 kA-3 hrs), load cycling test (1 kA-8 hrs + 0 A-16 hrs for 20 days), etc. were performed All the test showed no deterioration of the electrical properties of cable core after cable laying and thermal cycling process and also the stability of the system.