Jiaqi Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaqi Zhou has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Li Zeng
Department of Ophthalmology, Eye, Ear, Nose & Throat Hospital of Fudan University, Shanghai 200031, China
2 shared publications - Zhi Chen
Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
2 shared publications - Bingjie Wang
School of Optometry and Vision Science, University of New South Wales, Sydney, NSW 2052, Australia
1 shared publication Can Chen
1 shared publication- Changfei Li
Department of Ophthalmology, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, 758 Hefei Road, Qingdao 266035, China
1 shared publication Feng Xue
1 shared publication
Latest Publications
- 30 April 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (6) , 249-254
Redistribution of Epithelium and Stroma and Their Relationship With Corneal Curvature After 1-Month Cessation of Overnight Orthokeratology
Objectives: To investigate the changes in the thickness of epithelium and stroma and their relationship with corneal curvature following the cessation of overnight orthokeratology for a period of 1 month. Methods: This prospective study consecutively included 20 juveniles (20 right eyes) who had undergone overnight orthokeratology for a minimum of one year and were willing to discontinue the treatment. The study measured and compared epithelial and corneal curvature using optical coherence tomography and Medmont topographer at the first day of cessation and 1 month after cessation. In addition, changes in uncorrected visual acuity and refractive error before and after the cessation of the treatment were analyzed. Results: The study found a significant increase in the thickness of the epithelium in the central 2-mm area after the cessation of the treatment (t = −4.807, PP=0.016, P=0.016). Regarding the correlation analysis, the change in central epithelial thickness (ΔCET) was significantly correlated with the change in paracentral corneal curvature (ΔPCCC) (r=0.610, P=0.007) and the change in peripheral corneal curvature (ΔPCC) (r=0.597, P=0.009). Similarly, the change in central stromal thickness (ΔCST) was significantly correlated with the change in central corneal curvature (ΔCCC) (r=0.500, P=0.035), ΔPCCC (r=0.700, P=0.001), and ΔPCC (r=0.635, P=0.005). Conclusions: The study found that the corneal remodeling induced by orthokeratology was reversible after the cessation of the treatment. Specifically, changes in the epithelium were found to be more prominent in the central area, while changes in the stroma were more pronounced in the paracentral and peripheral areas. In addition, the study established a significant correlation between central corneal remodeling and changes in curvature.
- 30 April 2024
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 50 (6) , 249-254
Redistribution of Epithelium and Stroma and Their Relationship With Corneal Curvature After 1-Month Cessation of Overnight Orthokeratology
Objectives: To investigate the changes in the thickness of epithelium and stroma and their relationship with corneal curvature following the cessation of overnight orthokeratology for a period of 1 month. Methods: This prospective study consecutively included 20 juveniles (20 right eyes) who had undergone overnight orthokeratology for a minimum of one year and were willing to discontinue the treatment. The study measured and compared epithelial and corneal curvature using optical coherence tomography and Medmont topographer at the first day of cessation and 1 month after cessation. In addition, changes in uncorrected visual acuity and refractive error before and after the cessation of the treatment were analyzed. Results: The study found a significant increase in the thickness of the epithelium in the central 2-mm area after the cessation of the treatment (t = −4.807, PP=0.016, P=0.016). Regarding the correlation analysis, the change in central epithelial thickness (ΔCET) was significantly correlated with the change in paracentral corneal curvature (ΔPCCC) (r=0.610, P=0.007) and the change in peripheral corneal curvature (ΔPCC) (r=0.597, P=0.009). Similarly, the change in central stromal thickness (ΔCST) was significantly correlated with the change in central corneal curvature (ΔCCC) (r=0.500, P=0.035), ΔPCCC (r=0.700, P=0.001), and ΔPCC (r=0.635, P=0.005). Conclusions: The study found that the corneal remodeling induced by orthokeratology was reversible after the cessation of the treatment. Specifically, changes in the epithelium were found to be more prominent in the central area, while changes in the stroma were more pronounced in the paracentral and peripheral areas. In addition, the study established a significant correlation between central corneal remodeling and changes in curvature.
- Open Access
- 24 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5635
To Achieve a Bullseye: Factors Related to Corneal Refractive Therapy Orthokeratology Lens Toricity
This retrospective study investigated the toricity of dual-axis corneal refractive therapy (CRT) orthokeratology lenses and corneal parameters, including flat keratometry (FK), flat eccentricity (e), steep e, corneal astigmatism, and the difference in elevation at 8 mm chord length. We analyzed the right eyes of 143 adolescent patients who underwent ocular examinations, subjective refraction, and corneal topography before CRT lens fitting by trial lens evaluation. After orthokeratology treatment, all patients underwent a topography map with an intact plus power ring and decentration of p = 0.003) and the difference in elevation at 8 mm chord length (β = 0.681, t = 4.049, p < 0.001); no association was found between CRT lens toricity and FK, flat e, or steep e (all p > 0.05). Corneal astigmatism was positively associated with difference in elevation at 8 mm chord length (r = 0.743, p < 0.001, Pearson’s correlation), and corneal astigmatism and the difference in elevation at 8 mm chord length were positively associated with CRT lens toricity (r = 0.657 and r = 0.643, respectively; both p < 0.01, Spearman’s correlation). These results suggest that difference in elevation at 8 mm chord length can be used to conveniently estimate CRT lens toricity in clinical practice, using the equation Y (CRT lens toricity) = 1.02X (difference in elevation at 8 mm chord length) + 20.3.
- 24 September 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5635
Open AccessTo Achieve a Bullseye: Factors Related to Corneal Refractive Therapy Orthokeratology Lens Toricity
This retrospective study investigated the toricity of dual-axis corneal refractive therapy (CRT) orthokeratology lenses and corneal parameters, including flat keratometry (FK), flat eccentricity (e), steep e, corneal astigmatism, and the difference in elevation at 8 mm chord length. We analyzed the right eyes of 143 adolescent patients who underwent ocular examinations, subjective refraction, and corneal topography before CRT lens fitting by trial lens evaluation. After orthokeratology treatment, all patients underwent a topography map with an intact plus power ring and decentration of p = 0.003) and the difference in elevation at 8 mm chord length (β = 0.681, t = 4.049, p < 0.001); no association was found between CRT lens toricity and FK, flat e, or steep e (all p > 0.05). Corneal astigmatism was positively associated with difference in elevation at 8 mm chord length (r = 0.743, p < 0.001, Pearson’s correlation), and corneal astigmatism and the difference in elevation at 8 mm chord length were positively associated with CRT lens toricity (r = 0.657 and r = 0.643, respectively; both p < 0.01, Spearman’s correlation). These results suggest that difference in elevation at 8 mm chord length can be used to conveniently estimate CRT lens toricity in clinical practice, using the equation Y (CRT lens toricity) = 1.02X (difference in elevation at 8 mm chord length) + 20.3.
- Open Access
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1091
Factors Affecting Long-Term Compliance with Rigid Gas-Permeable Contact Lens Wear in Patients with Keratoconus
The purpose of the study was to investigate the factors affecting long-term compliance with rigid gas-permeable contact lens (RGPCL) wear in patients with keratoconus (KC). A total of 189 patients with KC (374 eyes) were included in the study, and were divided into two groups: the compliant group and the non-compliant group. Corneal topographic measurements, refractive results, and RGPCL parameters were compared between the two groups. A vision-related quality of life questionnaire was completed by all of the patients. The results demonstrated that patients diagnosed with bilateral KC were more compliant with RGPCL wear than patients diagnosed with unilateral KC (p = 0.0167). There were no significant differences between the compliant and non-compliant groups in terms of their corneal topographic measurements, refractive results, RGPCL parameters, or corneal cross-linking surgery history (all p > 0.05). In contrast, KC patients’ subjective experience with RGPCL wear—including visual acuity (p = 0.006), overall satisfaction (p < 0.001), quality of life (p < 0.001), and good adaptation during the short-term (p < 0.001)—had a significant effect on the long-term compliance with RGPCL wear. In conclusion, patients’ subjective experiences, rather than their ocular biometrics, significantly influence their long-term compliance with RGPCL wear.
- 18 February 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (4) , 1091
Open AccessFactors Affecting Long-Term Compliance with Rigid Gas-Permeable Contact Lens Wear in Patients with Keratoconus
The purpose of the study was to investigate the factors affecting long-term compliance with rigid gas-permeable contact lens (RGPCL) wear in patients with keratoconus (KC). A total of 189 patients with KC (374 eyes) were included in the study, and were divided into two groups: the compliant group and the non-compliant group. Corneal topographic measurements, refractive results, and RGPCL parameters were compared between the two groups. A vision-related quality of life questionnaire was completed by all of the patients. The results demonstrated that patients diagnosed with bilateral KC were more compliant with RGPCL wear than patients diagnosed with unilateral KC (p = 0.0167). There were no significant differences between the compliant and non-compliant groups in terms of their corneal topographic measurements, refractive results, RGPCL parameters, or corneal cross-linking surgery history (all p > 0.05). In contrast, KC patients’ subjective experience with RGPCL wear—including visual acuity (p = 0.006), overall satisfaction (p < 0.001), quality of life (p < 0.001), and good adaptation during the short-term (p < 0.001)—had a significant effect on the long-term compliance with RGPCL wear. In conclusion, patients’ subjective experiences, rather than their ocular biometrics, significantly influence their long-term compliance with RGPCL wear.