AŞAdnan Şimşek

Adnan Şimşek

*This is an algorithmically generated author record based on publicly available information.

Adnan Şimşek has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Final report on CCQM-K167: carbon isotope delta measurements of vanillin

    by Michelle M G Chartrand, Ian Chubchenko, Philip J H Dunn, Bruno Carius Garrido, Lu Hai, Fong-Ha Liu, Nives Ogrinc, Adnan Simsek, Maíra Fasciotti, Heidi Goenaga-Infante, et al.

    Main text: The CCQM Isotope Ratio Working Group (IRWG) determined that an additional key comparison of carbon isotope delta measurements was required to capture the progress of this field. Vials containing 0.25 mg of vanillin were prepared at NRC, and evaluated for bottle-to-bottle homogeneity prior to distribution to the eight participating institutes. Participants were able to choose any suitable method and reference materials for carbon isotope delta measurements, and report a carbon isotope delta value and the associated uncertainty, and analysis details. To determine the key comparison reference value (KCRV) and its associated uncertainty, the NRC in collaboration with the NIST, developed a multivariate Bayesian random laboratory effects model, which also incorporates the uncertainty due to bottle-to-bottle homogeneity and any correlations between the reported results that arise due to the use of common reference materials. The KCRV for this study was determined to be -25.833 ‰ relative to the VPDB, with associated uncertainty of 0.028 ‰, and expanded uncertainty of 0.056 ‰ (k=2). All the results reported by the participants in this study were considered equivalent to the KCRV. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Open Access

    DEVELOPING STATIC AND DYNAMIC STABLE ISOTOPE REFERENCE GAS MIXTURES OF CO2 AT 400 µmol/mol

    by Aylin Boztepe, Tanıl Tarhan, Zeynep Gülsoy Şerif, Adnan Şimşek

    Climate change is one of the most urgent issues facing humanity today. Humans have been rapidly changing the balance of gases in the atmosphere which causes global warming. Burning fossil fuels like coal and oil, farming and forestry, agriculture and cement manufacture cause to release water vapor, carbon dioxide (CO2), methane (CH4), ozone and nitrous oxide (N2O) known as the primary greenhouse gases. According to Intergovernmental Panel on Climate Change (IPCC), carbon dioxide is the most common greenhouse gas absorbing infrared energy emitted from the earth, preventing it from returning to space. It is necessary to separate man-made (anthropogenic) emissions from natural contributions in the atmosphere to obtain accurate emission data [1-4]. Since it could not be achieved with the existing metrological infrastructure, it is required to develop the measurements and references of stable isotopes of CO2. In this study, static and dynamic reference materials for pure CO2 at 400 µmol/mol in air matrix were prepared and it was provided to simulate CO2 gas in the atmosphere.The static gas mixtures were prepared gravimetrically in accordance with the ISO 6142-1 standard. In order to obtain CO2 gas at desired isotopic compositions, commercial CO2 gases were also supplied from abroad. Their isotopic compositions were measured by using GC-IRMS. Before filling, aluminum cylinders were evacuated until the pressure of 10-7 mbar using turbo-molecular vacuum pump. Isotopic compositions of reference materials were determined in a way that covering the range -42 ‰ to +1 ‰ vs VPDB for d13C-CO2 and -35 ‰ to -8 ‰ vs VPDB for d18O. In order to develop static and dynamic reference materials of CO2 at 400 µmol/mol in air with the uncertainty targets of d13C-CO2 0.1 ‰ and d18O-CO2 0.5 ‰, previously prepared pure CO2 reference gases were used. Dynamic dilution system with the high accuracy was constructed to generate dynamic reference gas mixture of CO2 at 400 µmol/mol. System contains 3 electronic pressure controllers, 3 thermal mass flow controllers with various capacities and 3 molbloc-L flow elements commanded with 2 Molboxes. The isotopic compositions of dynamic reference gas mixtures of CO2 at 400 µmol/mol were aimed to be same with the previously prepared pure CO2 reference gases. The whole dilution system were calibrated at INRIM to achieve lower uncertainties around 0.07-0.09%. At the measurement stage, CRDS and GC-IRMS equipments are operated simultaneously to determine the concentrations and isotopic compositions of the gas mixtures. The amount of substance fractions of the dynamic reference mixtures are calculated according to ISO 6145-7 standard. It will be checked that whether the isotopic compositions of the gravimetrically prepared pure CO2 reference gases and the dynamic reference gas mixtures of CO2 at 400 µmol/mol were same or not.REFERENCES[1] Calabro P. S., “Greenhouse gases emission from municipal waste management: The role of separate collection”, Waste Management, Volume 29:7, 2178-2187, 2009.[2] Sources of Greenhouse Gas Emissions, United States Environmental Protection Agency, https://www.epa.gov/ghgemissions/sources-greenhouse-gas-emissions, 2019.[3] Schwartz, S.E., “The Greenhouse Effect and Climate Change”, 2017.[4] Climate Change, The Intergovernmental Panel on Climate Change, https://www.ipcc.ch/report/ar4/wg1, 2019.

  • Practical and theoretical considerations for the determination of δ 13 C VPDB values of methylmercury in the environment

    by Philip J.H. Dunn, Mine Bilsel, Adnan Şimşek, Ahmet Ceyhan Gören, Murat Tunç, Nives Ogrinc, Milena Horvat, Heidi Goenaga‐Infante

    Rationale: Analytical methods that can identify the source and fate of mercury and organomercury compounds are likely to be useful tools to investigate mercury in the environment. Carbon isotope ratio analysis of methylmercury (MeHg) together with mercury isotope ratios may offer a robust tool to study environmental cycling of organomercury compounds within fish tissues and other matrices. Methods: MeHg carbon isotope ratios were determined by gas chromatography/combustion‐isotope ratio mass spectrometry (GC/C‐IRMS) either directly or following derivatization using sodium tetraethylborate. The effects of a normalization protocol and of derivatization on the measurement uncertainty of the methylmercury δ 13 C VPDB values were investigated. Results: GC/C‐IRMS analysis resulted in a δ 13 C VPDB value for an in‐house MeHg reference material of δ 13 C VPDB = −68.3 ± 7.7‰ (combined standard uncertainty, k = 1). This agreed very well with the value obtained by offline flow‐injection analysis/chemical oxidation/isotope ratio mass spectrometry of δ 13 C VPDB = −68.85 ± 0.17‰ (combined standard uncertainty, k = 1) although the uncertainty was substantially larger. The minimum amount of MeHg required for analysis was determined to be 20 μg. Conclusions: While the δ 13 C VPDB values of MeHg can be obtained by GC/C‐IRMS methods with or without derivatization, the low abundance of MeHg precludes such analyses in fish tissues unless there is substantial MeHg contamination. Environmental samples with sufficient MeHg pollution can be studied using these methods provided that the MeHg can be quantitatively extracted. The more general findings from this study regarding derivatization protocol implementation within an autosampler vial as well as measurement uncertainty associated with derivatization, normalization to reporting scales and integration are applicable to other GC/C‐IRMS‐based measurements.