XKXiaoxiao Kang

Xiaoxiao Kang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoxiao Kang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Wearable Multi-Channel Pulse Signal Acquisition System Based on Flexible MEMS Sensor Arrays with TSV Structure

    by Xiaoxiao Kang, Lin Huang, Yitao Zhang, Shichang Yun, Binbin Jiao, Xin Liu, Jun Zhang, Zhiqiang Li, Haiying Zhang

    Micro-electro-mechanical system (MEMS) pressure sensors play a significant role in pulse wave acquisition. However, existing MEMS pulse pressure sensors bound with a flexible substrate by gold wire are vulnerable to crush fractures, leading to sensor failure. Additionally, establishing an effective mapping between the array sensor signal and pulse width remains a challenge. To solve the above problems, we propose a 24-channel pulse signal acquisition system based on a novel MEMS pressure sensor with a through-silicon-via (TSV) structure, which connects directly to a flexible substrate without gold wire bonding. Firstly, based on the MEMS sensor, we designed a 24-channel pressure sensor flexible array to collect the pulse waves and static pressure. Secondly, we developed a customized pulse preprocessing chip to process the signals. Finally, we built an algorithm to reconstruct the three-dimensional pulse wave from the array signal and calculate the pulse width. The experiments verify the high sensitivity and effectiveness of the sensor array. In particular, the measurement results of pulse width are highly positively correlated with those obtained via infrared images. The small-size sensor and custom-designed acquisition chip meet the needs of wearability and portability, meaning that it has significant research value and commercial prospects.


  • Open Access

    Multi-Morphological Pulse Signal Feature Point Recognition Based on One-Dimensional Deep Convolutional Neural Network

    by Guotai Wang, Xingguang Geng, Lin Huang, Xiaoxiao Kang, Jun Zhang, Yitao Zhang, Haiying Zhang

    Radial pulse signals are produced by the periodic ejection of blood from the heart, and physiological and pathological information of the human body can be analyzed by extracting the time-domain characteristics of pulse waves. However, since pulse signals are weak physiological signals on the body surface and complex, the acquisition of pulse characteristics using the traditional curvature method will produce a large error, which cannot meet the needs of pulse wave analysis in current clinical practice. To solve this problem, a multi-morphological pulse signal feature recognition algorithm based on the one-dimensional deep convolutional neural network (1D-DCNN) model is proposed. We used the multi-channel pulse diagnosis instrument independently developed by the team to collect radial pulse signals under continuous pressure of the test subjects and collected 115 subjects and extracted a total of 1300 single-cycle pulse signals and then divided these pulse signals into 6 different forms. Five types of pulse signal time-domain feature points were labeled, and five independent feature point datasets were labeled and formed five customized neural network models that were generated to train and identify the pulse feature point datasets independently. The results show that the correction coefficient (Radjusted2) of the multi-class pulse signal processing algorithm proposed in this paper for each type of feature point recognition reaches more than 0.92. The performance is significantly better than that of the traditional curvature method, which shows the accuracy and superiority of the proposed method. Therefore, the multi-class pulse signal characteristic parameter recognition model based on the 1D-DCNN model proposed in this paper can efficiently and accurately identify pulse time-domain characteristic parameters, which can be applied to discriminate time-domain pulse information in clinical practice and assist doctors in diagnosis.


  • Open Access

    A Novel Radial Artery P-S Curve Model Based on Radial Vibration of Vascular Wall

    by Guotai Wang, Xingguang Geng, Xiaoxiao Kang, Yitao Zhang, Jun Zhang, Haiying Zhang

    In pulse wave analysis, the changing curve of pulse wave strength with continuous increasing pressure, that is, the P-S (pressure-strength) curve, contains abundant human physiological information, but there is no accurate model to describe the formation mechanism of the curve. Therefore, this paper proposes a modeling method of the radial artery P-S curve based on the radial vibration of the vascular wall. The modeling method includes three parts. Firstly, based on hemodynamics, we proposed the blood motion equation in the pulsation process of healthy people. Secondly, the motion equation of the vascular wall based on the fluid–structure interaction between blood motion and vascular wall was established. Finally, according to the elastic theory of the vascular wall, the relationship between pulse strength and extravascular pressure of blood vessels was found. To verify the accuracy and applicability of the model, this paper simulated the changes in the vascular wall stress and the intravascular pressure with the extravascular pressure during the process of vascular deformation. In addition, 69 healthy volunteers were selected to participate in this study. Based on the gradient compression, the pulse strength envelope under the continuous pressure sequence of the radial artery, namely the pulse P-S curve, was extracted. We also analyzed the relationship between the individual P-S curve difference and BMI. The results show that the actual human body data collection and analysis results are consistent with the theoretical model established in this paper, which indicates that the model can provide a novel idea for the evaluation of the state of the human body.


  • Open Access

    A Wearable and Real-Time Pulse Wave Monitoring System Based on a Flexible Compound Sensor

    by Xiaoxiao Kang, Jun Zhang, Zheming Shao, Guotai Wang, Xingguang Geng, Yitao Zhang, Haiying Zhang

    Continuous monitoring of pulse waves plays a significant role in reflecting physical conditions and disease diagnosis. However, the current collection equipment cannot simultaneously achieve wearable and continuous monitoring under varying pressure and provide personalized pulse wave monitoring targeted different human bodies. To solve the above problems, this paper proposed a novel wearable and real-time pulse wave monitoring system based on a novel flexible compound sensor. Firstly, a custom-packaged pressure sensor, a signal stabilization structure, and a micro pressurization system make up the flexible compound sensor to complete the stable acquisition of pulse wave signals under continuously varying pressure. Secondly, a real-time algorithm completes the analysis of the trend of the pulse wave peak, which can quickly and accurately locate the best pulse wave for different individuals. Finally, the experimental results show that the wearable system can both realize continuous monitoring and reflecting trend differences and quickly locate the best pulse wave for different individuals with the 95% accuracy. The weight of the whole system is only 52.775 g, the working current is 46 mA, and the power consumption is 160 mW. Its small size and low power consumption meet wearable and portable scenarios, which has significant research value and commercialization prospects.