Amoako-Atta Ernest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amoako-Atta Ernest has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anna Dunay
Doctoral School of Management and Business Administration, John Von Neumann University, Budapest, Hungary
1 shared publication - Billal Hossain
WIUT Business School, Westminster International University in Tashkent (WIUT), Tashkent 100047, Uzbekistan
1 shared publication - Csaba Bálint Illés
Hungarian National Bank—Research Center, John von Neumann University, 6000 Kecskemét, Hungary
1 shared publication - Dolores Mensah Hervie
Szent István Campus, Doctoral School of Economic and Regional Sciences, Hungarian University of Agriculture and Life Sciences, Páter Károly utca 1, H-2100 Gödöllő, Hungary
1 shared publication - Guohang Tian
College of Landscape Architecture and Art, Henan Agricultural University, Zhengzhou 450002, China
1 shared publication - Handong Meng
CMA Henan Key Laboratory of Agrometeorological Support and Applied Technique, Zhengzhou 450003, China
1 shared publication
Latest Publications
- Open Access
- 22 February 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (5) , 2509
Impact of COVID-19 Pandemic on Hotel Employees in the Greater Accra Region of Ghana
This study examines the effect of the COVID-19 pandemic on hotel employees in the Greater Accra Region of Ghana using the conservation of resource and human relations theories to ascertain the level of impact. Data was collected from 511 hotel employees from 58 hotels using questionnaires. The employees were randomly sampled. Stepwise Regression in Statistical Package for Social Sciences version 16 model was used to run the analysis. Nine independent variables were included in a stepwise regression model. Six came out as significant and explained 51.6% of the variation in the percentage of their salary that staff received during the current COVID-19 pandemic. The remaining 48.4% was explained by other factors such as the years of service and whether the facility shut down during the lockdown. It was further identified that about 80% of the respondents had their salaries reduced, and that work schedules and working hours were altered, particularly during the lockdown and closure of the country’s borders. It is recommended that hotels should network, be more customer-oriented, be health- and safety-focused, frequently update their communication channels, and make digitalisation and human resource development a priority as measures to help the industry in its recovery process.
- 22 February 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (5) , 2509
Open AccessImpact of COVID-19 Pandemic on Hotel Employees in the Greater Accra Region of Ghana
This study examines the effect of the COVID-19 pandemic on hotel employees in the Greater Accra Region of Ghana using the conservation of resource and human relations theories to ascertain the level of impact. Data was collected from 511 hotel employees from 58 hotels using questionnaires. The employees were randomly sampled. Stepwise Regression in Statistical Package for Social Sciences version 16 model was used to run the analysis. Nine independent variables were included in a stepwise regression model. Six came out as significant and explained 51.6% of the variation in the percentage of their salary that staff received during the current COVID-19 pandemic. The remaining 48.4% was explained by other factors such as the years of service and whether the facility shut down during the lockdown. It was further identified that about 80% of the respondents had their salaries reduced, and that work schedules and working hours were altered, particularly during the lockdown and closure of the country’s borders. It is recommended that hotels should network, be more customer-oriented, be health- and safety-focused, frequently update their communication channels, and make digitalisation and human resource development a priority as measures to help the industry in its recovery process.
- Open Access
- 14 August 2020
- Published by MDPI AG in Atmosphere
- Vol. 11 (8) , 862
Analysis of Cooling and Humidification Effects of Different Coverage Types in Small Green Spaces (SGS) in the Context of Urban Homogenization: A Case of HAU Campus Green Spaces in Summer in Zhengzhou, China
In the context of global warming, more and more cities are experiencing extreme Urban Heat Island (UHI) effects and extreme weather phenomena, but urban green spaces are proven to mitigate UHI. Most of UHI’s research focuses on the large scale and uses remote sensing methods, which do not reflect the dynamic characteristics in detail and do not detect internal influencing factors of the green space cooling effect. Therefore, this study focused on Small Green Spaces (SGS), carrying out the measurement of the meteorological parameters (temperature, relative humidity, wind direction, wind speed, photosynthetic radiation) of the 16 sites in four types of coverage (Impervious surface; Shrub-grass; Tree-grass; Tree-shrub-grass) in a university campus. At the same time, the coverage characteristic parameters, such as Canopy Density (CD), Leaf Area Index (LAI), Photosynthetically Active Radiation (PAR), Mean Leaf Angle (MLA), of each plot were analyzed and compared. The results showed that there were significant differences in temperature among different coverage types in SGS. The biggest difference was concentrated in the noon period when solar radiation is strongest during the day. The difference between the four types of coverage with vegetation at night was small. The maximum air temperature difference among the four types could reach 8.9 ℃ and the maximum relative humidity difference was 28.5%. The cooling effect of the multi-layer vegetation-covered (Tree-shrub-grass) area was the largest compared to the impervious surface, indicating that tree cover was the core factor affecting the temperature. Temperature and relative humidity had a close correlation with surface coverage types and some plant community characteristics (such as CD and LAI). The cooling and humidifying effects of plants were also related to PAR and leaf angle. The results provide suggestions for green space management and landscape design.
- 14 August 2020
- Published by MDPI AG in Atmosphere
- Vol. 11 (8) , 862
Open AccessAnalysis of Cooling and Humidification Effects of Different Coverage Types in Small Green Spaces (SGS) in the Context of Urban Homogenization: A Case of HAU Campus Green Spaces in Summer in Zhengzhou, China
In the context of global warming, more and more cities are experiencing extreme Urban Heat Island (UHI) effects and extreme weather phenomena, but urban green spaces are proven to mitigate UHI. Most of UHI’s research focuses on the large scale and uses remote sensing methods, which do not reflect the dynamic characteristics in detail and do not detect internal influencing factors of the green space cooling effect. Therefore, this study focused on Small Green Spaces (SGS), carrying out the measurement of the meteorological parameters (temperature, relative humidity, wind direction, wind speed, photosynthetic radiation) of the 16 sites in four types of coverage (Impervious surface; Shrub-grass; Tree-grass; Tree-shrub-grass) in a university campus. At the same time, the coverage characteristic parameters, such as Canopy Density (CD), Leaf Area Index (LAI), Photosynthetically Active Radiation (PAR), Mean Leaf Angle (MLA), of each plot were analyzed and compared. The results showed that there were significant differences in temperature among different coverage types in SGS. The biggest difference was concentrated in the noon period when solar radiation is strongest during the day. The difference between the four types of coverage with vegetation at night was small. The maximum air temperature difference among the four types could reach 8.9 ℃ and the maximum relative humidity difference was 28.5%. The cooling effect of the multi-layer vegetation-covered (Tree-shrub-grass) area was the largest compared to the impervious surface, indicating that tree cover was the core factor affecting the temperature. Temperature and relative humidity had a close correlation with surface coverage types and some plant community characteristics (such as CD and LAI). The cooling and humidifying effects of plants were also related to PAR and leaf angle. The results provide suggestions for green space management and landscape design.