Bing Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bing Cai has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jiangtao Sun
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications - Jinhai Hu
Daqing Oilfield Company Ltd., Daqing, China
2 shared publications - Liang Sun
Daqing Oilfield Company Ltd., Daqing, China
2 shared publications - Lijun Xu
Beihang University
2 shared publications - Ronghua Xie
Daqing Oilfield Company Ltd., Daqing, China
2 shared publications - Xiaokai Zhang
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2336-2345
Comparison of Transverse With Axial Excitation Modes Cross Correlation Flowmeters in High Water-Cut Oil–Water Flow Measurement
Due to long-term exploitation of oil wells, high water-cut oil-water two-phase flow has become one of the most common flow types in offshore oil fields. In this work, two cross-correlation flowmeters for this type of flow, i.e. the newly proposed transverse excitation mode flowmeter and the conventional axial excitation mode flowmeter are theoretically analyzed, numerically solved and experimentally compared. By building theoretical models, the resolutions and sensitivities of the sensors are systematically compared to demonstrate their abilities of detecting oil bubbles in water. From the numerical solutions by the FEM models, the resolutions of the sensors are analyzed in spatial frequency domain, and more accurate analysis of sensitivities can be made. Results show that the resolution of the transverse excitation mode flowmeter is approximately 3 times higher, and the sensitivity is at most 3.47 times higher than the axial excitation mode one. Experiments with 10 m 3 /d, 90%-water-cut oil-water two-phase flow are carried out to demonstrate the dynamic performances of the two flowmeters. It can be concluded that the transverse excitation mode flowmeter has higher accuracy and reliability in flow rate measurement.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2336-2345
Comparison of Transverse With Axial Excitation Modes Cross Correlation Flowmeters in High Water-Cut Oil–Water Flow Measurement
Due to long-term exploitation of oil wells, high water-cut oil-water two-phase flow has become one of the most common flow types in offshore oil fields. In this work, two cross-correlation flowmeters for this type of flow, i.e. the newly proposed transverse excitation mode flowmeter and the conventional axial excitation mode flowmeter are theoretically analyzed, numerically solved and experimentally compared. By building theoretical models, the resolutions and sensitivities of the sensors are systematically compared to demonstrate their abilities of detecting oil bubbles in water. From the numerical solutions by the FEM models, the resolutions of the sensors are analyzed in spatial frequency domain, and more accurate analysis of sensitivities can be made. Results show that the resolution of the transverse excitation mode flowmeter is approximately 3 times higher, and the sensitivity is at most 3.47 times higher than the axial excitation mode one. Experiments with 10 m 3 /d, 90%-water-cut oil-water two-phase flow are carried out to demonstrate the dynamic performances of the two flowmeters. It can be concluded that the transverse excitation mode flowmeter has higher accuracy and reliability in flow rate measurement.
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
A Modified Adaptive Cross Correlation Method for Flow Rate Measurement of High-Water-Cut Oil-Water Flow Using Planar Flowmeter
This article proposed a modified adaptive (MA) cross correlation method to measure the flow rate of high-water-cut oil-water two-phase flow. It asynchronously commences the acquisitions of the upstream and downstream signals for cross correlation according to the flow rate, enhancing the degree of correlation between them, thus a higher measurement accuracy of transition time can be obtained. By limiting the searching scope of the correlogram’s peak value in a transition time-related observation window, the calculation process is kept steady and divergence due to the outliers is effectively avoided. A planar flowmeter is adopted for high-water-cut flow rate measurement, and the advantages in axial resolution and sensitivity are analyzed. Experiments are conducted in 90% water cut oil-water flow in a practical vertical well. Results show that compared to the conventional (C) one, the MA method is capable of fast and reliable capture of the transition time from the upstream to the downstream sensors in a much wider flow rate range, with much lower deviation and a higher degree of correlation. Finally, the flow rates and their uncertainties are calculated from the measured transition time to validate the measurement stability.
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
A Modified Adaptive Cross Correlation Method for Flow Rate Measurement of High-Water-Cut Oil-Water Flow Using Planar Flowmeter
This article proposed a modified adaptive (MA) cross correlation method to measure the flow rate of high-water-cut oil-water two-phase flow. It asynchronously commences the acquisitions of the upstream and downstream signals for cross correlation according to the flow rate, enhancing the degree of correlation between them, thus a higher measurement accuracy of transition time can be obtained. By limiting the searching scope of the correlogram’s peak value in a transition time-related observation window, the calculation process is kept steady and divergence due to the outliers is effectively avoided. A planar flowmeter is adopted for high-water-cut flow rate measurement, and the advantages in axial resolution and sensitivity are analyzed. Experiments are conducted in 90% water cut oil-water flow in a practical vertical well. Results show that compared to the conventional (C) one, the MA method is capable of fast and reliable capture of the transition time from the upstream to the downstream sensors in a much wider flow rate range, with much lower deviation and a higher degree of correlation. Finally, the flow rates and their uncertainties are calculated from the measured transition time to validate the measurement stability.