Yoon-Seong Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yoon-Seong Lee has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chung-Yuen Won
Department of Electrical and Computer Engineering, College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
8 shared publications - Junsin Yi
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, Republic of Korea
7 shared publications - Chang-Hee Lee
Dawonsys Co., Ltd., Anyang 15655, Republic of Korea
3 shared publications - Chang-Gyun An
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
2 shared publications - Hoon Lee
Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Korea
2 shared publications - Kyoung-Min Choo
Electric Propulsion Research Center, Korea Electrotechnology Research Institute (KERI), Changwon 51541, Republic of Korea
2 shared publications
Latest Publications
- Open Access
Common-Mode Voltage Reduction Method Based on Variable Sampling Frequency Finite Control Set-Model Predictive Control for PMSM Drive Systems
In this article, a finite control set-model predictive control (FCS-MPC) with variable sampling time is proposed. A zero-voltage vector appears in the dead time between specific voltage vectors, resulting in an unintentionally large common-mode voltage. Herein, a large common-mode voltage was suppressed, and the load current was controlled using a voltage vector combination that did not cause a zero-voltage vector in dead time. Additionally, to improve the total harmonic distortion (THD) of the load current, the intersection of the predicted current and the command current by all the volage vectors (VVs) in the combination is confirmed. The VV where the intersection occurs is selected as the optimal VV. This optimal VV is applied to the point where the predicted current and the reference current intersect. The applicable range of the sampling time should be selected by considering the calculation time and number of switching. Through the proposed FCS-MPC strategy, not only can the common-mode voltage be limited to within ±Vdc/6, but an improved THD can also be obtained compared to the existing method using fixed sampling. The proposed method was verified through PSIM simulation and experimental results.
Open AccessCommon-Mode Voltage Reduction Method Based on Variable Sampling Frequency Finite Control Set-Model Predictive Control for PMSM Drive Systems
In this article, a finite control set-model predictive control (FCS-MPC) with variable sampling time is proposed. A zero-voltage vector appears in the dead time between specific voltage vectors, resulting in an unintentionally large common-mode voltage. Herein, a large common-mode voltage was suppressed, and the load current was controlled using a voltage vector combination that did not cause a zero-voltage vector in dead time. Additionally, to improve the total harmonic distortion (THD) of the load current, the intersection of the predicted current and the command current by all the volage vectors (VVs) in the combination is confirmed. The VV where the intersection occurs is selected as the optimal VV. This optimal VV is applied to the point where the predicted current and the reference current intersect. The applicable range of the sampling time should be selected by considering the calculation time and number of switching. Through the proposed FCS-MPC strategy, not only can the common-mode voltage be limited to within ±Vdc/6, but an improved THD can also be obtained compared to the existing method using fixed sampling. The proposed method was verified through PSIM simulation and experimental results.
- 22 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10658-10668
Control Strategy of Triple-Active-Bridge Converter for Bipolar DC Microgrid
The main assignment of a bipolar dc microgrid is the settlement of the bipolar voltage imbalance due to unbalanced loads and asymmetric powers. It is necessary to consider maintaining the bipolar systems whether in grid-connected mode or islanded mode of the microgrid. This article introduces the control strategy of the triple-active-bridge (TAB) converter for the bipolar dc microgrid by voltage balancing. The presented control strategy performs PN voltage regulation and voltage balancing based on the interrelation analysis between power and voltage in the bipolar dc microgrid. With the separately configured voltage balancing loop in the controller, the active voltage balancing through the power transfer between the bipolar buses is ensured even in the islanded mode without additional circuit components. The TAB converter operates with phase-shift modulation as conventional, and the control strategy is implemented through the digital signal processor. The validity of the proposal is verified by lab-scale experimental results.
- 22 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (9) , 10658-10668
Control Strategy of Triple-Active-Bridge Converter for Bipolar DC Microgrid
The main assignment of a bipolar dc microgrid is the settlement of the bipolar voltage imbalance due to unbalanced loads and asymmetric powers. It is necessary to consider maintaining the bipolar systems whether in grid-connected mode or islanded mode of the microgrid. This article introduces the control strategy of the triple-active-bridge (TAB) converter for the bipolar dc microgrid by voltage balancing. The presented control strategy performs PN voltage regulation and voltage balancing based on the interrelation analysis between power and voltage in the bipolar dc microgrid. With the separately configured voltage balancing loop in the controller, the active voltage balancing through the power transfer between the bipolar buses is ensured even in the islanded mode without additional circuit components. The TAB converter operates with phase-shift modulation as conventional, and the control strategy is implemented through the digital signal processor. The validity of the proposal is verified by lab-scale experimental results.
- Open Access
The Operation Method of Hybrid Power Supply System Combining Lithium Polymer Battery and Supercapacitor for Industrial Drones
This paper proposes a hybrid power supply system for commercial drones. The proposed hybrid power supply system consists of a lithium polymer battery, a supercapacitor, and a power converter for charging the supercapacitor. In the proposed system, the supercapacitor is pre-charged with a lithium polymer battery through a power converter, and the supercapacitor first supplies the power required for the drone’s initial startup and lift-up. Afterward, in the section where the power consumption of the drone is low, the battery and the supercapacitor supply power together, minimizing the stress on the battery. To verify the proposed hybrid power supply system, a computer simulation was conducted, the actual hardware was fabricated, and experiments were performed.
Open AccessThe Operation Method of Hybrid Power Supply System Combining Lithium Polymer Battery and Supercapacitor for Industrial Drones
This paper proposes a hybrid power supply system for commercial drones. The proposed hybrid power supply system consists of a lithium polymer battery, a supercapacitor, and a power converter for charging the supercapacitor. In the proposed system, the supercapacitor is pre-charged with a lithium polymer battery through a power converter, and the supercapacitor first supplies the power required for the drone’s initial startup and lift-up. Afterward, in the section where the power consumption of the drone is low, the battery and the supercapacitor supply power together, minimizing the stress on the battery. To verify the proposed hybrid power supply system, a computer simulation was conducted, the actual hardware was fabricated, and experiments were performed.
- Open Access
A Virtual Impedance-Based Flying Start Considering Transient Characteristics for Permanent Magnet Synchronous Machine Drive Systems
A virtual impedance-based flying start considering transient characteristics for permanent magnet synchronous machine drive systems is proposed. The conventional flying start based on virtual resistance (VR) assumes that the load of the system is resistive. However, the maximum value of VR, which is determined by the machine parameter and sampling frequency, is sometimes small. In this case, the load of the system is non-resistive. This assumption error causes an estimated position error and degrades transient characteristics. In the proposed method, algebraic-type virtual inductance (VI) is added to the estimation current regulator of the flying start based on VR. This change improves the accuracy of the estimated rotor position and the transient characteristics. In addition, the discrete-time system model of the proposed flying start method is given, the stability was analyzed considering the change in VR caused by the proposed method, and the improvements were verified by PSIM simulations and experimental results.
Open AccessA Virtual Impedance-Based Flying Start Considering Transient Characteristics for Permanent Magnet Synchronous Machine Drive Systems
A virtual impedance-based flying start considering transient characteristics for permanent magnet synchronous machine drive systems is proposed. The conventional flying start based on virtual resistance (VR) assumes that the load of the system is resistive. However, the maximum value of VR, which is determined by the machine parameter and sampling frequency, is sometimes small. In this case, the load of the system is non-resistive. This assumption error causes an estimated position error and degrades transient characteristics. In the proposed method, algebraic-type virtual inductance (VI) is added to the estimation current regulator of the flying start based on VR. This change improves the accuracy of the estimated rotor position and the transient characteristics. In addition, the discrete-time system model of the proposed flying start method is given, the stability was analyzed considering the change in VR caused by the proposed method, and the improvements were verified by PSIM simulations and experimental results.
- Open Access
- 11 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 18557-18569
Space Vector Pulse-Width Modulation Control Strategy for Four-Leg Inverters Under Single Line-to-Ground Faults in Islanded Microgrids
In this paper, we propose a novel switching modulation scheme for three-phase four-leg inverters that enables the separation of the fault points occurring in AC distribution networks. The proposed method is aimed at continuously supplying normal voltage to the remaining healthy phases while applying zero voltage to any faulty phase when a single line-to-ground (SLG) fault occurs in the distribution network. This modulation scheme allows isolation without physically blocking the point of failure. This can prevent unnecessary continuous outages in the AC distribution network. To this end, we propose a novel coordinate transformation method to extract accurate values for the magnitude of unbalanced three-phase voltages. A novel space vector pulse-width modulation (SVPWM) method for switching schemes that are used under fault conditions is also presented. The proposed coordinate transformation considers a plane lying in a three-dimensional (3-D) space that describes the rotation of a three-phase voltage vector. This transformation converts a physical quantity that rotates in 3-D space into a value that moves in two-dimensional (2-D) space. Subsequently, the use of synchronous reference frame (SRF) transformation enables the detection and control of the voltage magnitude in case of an SLG fault. Additionally, switching vectors are selected to apply zero voltage to the faulty phase by analyzing the switching vector diagram of a four-leg inverter. Mathematical analyses conducted for the entire process are detailed herein. Further, the experimental results of four-leg inverters designed for the 10 kW class verify the proposed strategies.
- 11 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 18557-18569
Open AccessSpace Vector Pulse-Width Modulation Control Strategy for Four-Leg Inverters Under Single Line-to-Ground Faults in Islanded Microgrids
In this paper, we propose a novel switching modulation scheme for three-phase four-leg inverters that enables the separation of the fault points occurring in AC distribution networks. The proposed method is aimed at continuously supplying normal voltage to the remaining healthy phases while applying zero voltage to any faulty phase when a single line-to-ground (SLG) fault occurs in the distribution network. This modulation scheme allows isolation without physically blocking the point of failure. This can prevent unnecessary continuous outages in the AC distribution network. To this end, we propose a novel coordinate transformation method to extract accurate values for the magnitude of unbalanced three-phase voltages. A novel space vector pulse-width modulation (SVPWM) method for switching schemes that are used under fault conditions is also presented. The proposed coordinate transformation considers a plane lying in a three-dimensional (3-D) space that describes the rotation of a three-phase voltage vector. This transformation converts a physical quantity that rotates in 3-D space into a value that moves in two-dimensional (2-D) space. Subsequently, the use of synchronous reference frame (SRF) transformation enables the detection and control of the voltage magnitude in case of an SLG fault. Additionally, switching vectors are selected to apply zero voltage to the faulty phase by analyzing the switching vector diagram of a four-leg inverter. Mathematical analyses conducted for the entire process are detailed herein. Further, the experimental results of four-leg inverters designed for the 10 kW class verify the proposed strategies.
- Open Access
Space Vector Modulation (SVM)-Based Common-Mode Current (CMC) Reduction Method of H8 Inverter for Permanent Magnet Synchronous Motor (PMSM) Drives
This paper proposes a space vector modulation (SVM)-based common-mode (CM) currents reduction method of an H8 inverter for permanent magnet synchronous motor (PMSM) drives. There are power quality issues in the PMSM drive systems, such as current distortions and CM electromagnetic interference (EMI) due to the fast-switching operation of the inverter. These issues are related to CM voltage (CMV) and CM current (CMC). Although several studies have been conducted to reduce the CMV and CMC, some CMV variations and CMCs are still generated in the real implementation. Unlike conventional methods, the proposed method selects the voltage vectors with similar CMV levels and arranges them considering the series-connected switch operation of the H8 inverter in a voltage vector modulation sequence. At a low modulation index (MI), the proposed method completely restricts the CMV variations into six times. At high MI, the proposed method synthesizes the reference voltage vector differently, depending on the position of the reference vector, to reduce both current distortions and CMCs. The validity of the proposed method is verified through simulations and experimental results.
Open AccessSpace Vector Modulation (SVM)-Based Common-Mode Current (CMC) Reduction Method of H8 Inverter for Permanent Magnet Synchronous Motor (PMSM) Drives
This paper proposes a space vector modulation (SVM)-based common-mode (CM) currents reduction method of an H8 inverter for permanent magnet synchronous motor (PMSM) drives. There are power quality issues in the PMSM drive systems, such as current distortions and CM electromagnetic interference (EMI) due to the fast-switching operation of the inverter. These issues are related to CM voltage (CMV) and CM current (CMC). Although several studies have been conducted to reduce the CMV and CMC, some CMV variations and CMCs are still generated in the real implementation. Unlike conventional methods, the proposed method selects the voltage vectors with similar CMV levels and arranges them considering the series-connected switch operation of the H8 inverter in a voltage vector modulation sequence. At a low modulation index (MI), the proposed method completely restricts the CMV variations into six times. At high MI, the proposed method synthesizes the reference voltage vector differently, depending on the position of the reference vector, to reduce both current distortions and CMCs. The validity of the proposed method is verified through simulations and experimental results.
- Open Access
- 14 November 2021
- Published by MDPI AG in Electronics
- Vol. 10 (22) , 2791
Power Conversion System Operation Algorithm for Efficient Energy Management of Microgrids
This paper investigates the operation of each power conversion system (PCS) for efficient energy management systems (EMSs) of microgrids (MGs). When MGs are linked to renewable energy sources (RESs), the reduction in power conversion efficiency can be minimized. Furthermore, energy storage systems (ESSs) are utilized to manage the surplus power of RESs. Thus, the present work presents a method to minimize the use of the existing power grid and increase the utilization rate of energy generated through RESs. To minimize the use of the existing power grid, a PCS operation method for photovoltaics (PV) and ESS used in MGs is proposed. PV, when it is directly connected as an intermittent energy source, induces voltage fluctuations in the distribution network. Thus, to overcome this shortcoming, this paper utilizes a system that connects PV and a distributed energy storage system (DESS). A PV-DESS integrated module is designed and controlled for tracking constant power. In addition, the DESS serves to compensate for the insufficient power generation of PV. The main energy storage systems (MESSs) used in MGs affect all aspects of the power management in the system. Because MGs perform their operations based on the capacity of the MESS, a PCS designed with a large capacity is utilized to stably operate the system. Because the MESS performs energy management through operations under various load conditions, it must have constant efficiency under all load conditions. Therefore, this paper proposes a PCS operation algorithm with constant efficiency for the MESS. Utilizing the operation algorithm of each PCS, this paper describes the efficient energy management of the MG and further proposes an algorithm for operating the existing power grid at the minimum level.
- 14 November 2021
- Published by MDPI AG in Electronics
- Vol. 10 (22) , 2791
Open AccessPower Conversion System Operation Algorithm for Efficient Energy Management of Microgrids
This paper investigates the operation of each power conversion system (PCS) for efficient energy management systems (EMSs) of microgrids (MGs). When MGs are linked to renewable energy sources (RESs), the reduction in power conversion efficiency can be minimized. Furthermore, energy storage systems (ESSs) are utilized to manage the surplus power of RESs. Thus, the present work presents a method to minimize the use of the existing power grid and increase the utilization rate of energy generated through RESs. To minimize the use of the existing power grid, a PCS operation method for photovoltaics (PV) and ESS used in MGs is proposed. PV, when it is directly connected as an intermittent energy source, induces voltage fluctuations in the distribution network. Thus, to overcome this shortcoming, this paper utilizes a system that connects PV and a distributed energy storage system (DESS). A PV-DESS integrated module is designed and controlled for tracking constant power. In addition, the DESS serves to compensate for the insufficient power generation of PV. The main energy storage systems (MESSs) used in MGs affect all aspects of the power management in the system. Because MGs perform their operations based on the capacity of the MESS, a PCS designed with a large capacity is utilized to stably operate the system. Because the MESS performs energy management through operations under various load conditions, it must have constant efficiency under all load conditions. Therefore, this paper proposes a PCS operation algorithm with constant efficiency for the MESS. Utilizing the operation algorithm of each PCS, this paper describes the efficient energy management of the MG and further proposes an algorithm for operating the existing power grid at the minimum level.
- Open Access
- 11 August 2021
- Published by MDPI AG in Electronics
- Vol. 10 (16) , 1939
Energy Management Method of Hybrid AC/DC Microgrid Using Artificial Neural Network
This paper proposes an artificial neural network (ANN)-based energy management system (EMS) for controlling power in AC–DC hybrid distribution networks. The proposed ANN-based EMS selects an optimal operating mode by collecting data such as the power provided by distributed generation (DG), the load demand, and state of charge (SOC). For training the ANN, profile data on the charging and discharging amount of ESS for various distribution network power situations were prepared, and the ANN was trained with an error rate within 10%. The proposed EMS controls each power converter in the optimal operation mode through the already trained ANN in the grid-connected mode. For the experimental verification of the proposed EMS, a small-scale hybrid AD/DC microgrid was fabricated, and simulations and experiments were performed for each operation mode.
- 11 August 2021
- Published by MDPI AG in Electronics
- Vol. 10 (16) , 1939
Open AccessEnergy Management Method of Hybrid AC/DC Microgrid Using Artificial Neural Network
This paper proposes an artificial neural network (ANN)-based energy management system (EMS) for controlling power in AC–DC hybrid distribution networks. The proposed ANN-based EMS selects an optimal operating mode by collecting data such as the power provided by distributed generation (DG), the load demand, and state of charge (SOC). For training the ANN, profile data on the charging and discharging amount of ESS for various distribution network power situations were prepared, and the ANN was trained with an error rate within 10%. The proposed EMS controls each power converter in the optimal operation mode through the already trained ANN in the grid-connected mode. For the experimental verification of the proposed EMS, a small-scale hybrid AD/DC microgrid was fabricated, and simulations and experiments were performed for each operation mode.