Taro Nakamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Taro Nakamura has a total of 245 co-authors. Here are the top co-authors by number of shared publications:
- Yasuyuki Yamada
Faculty of Engineering and Design, Hosei University
36 shared publications - Manabu Okui
Chuo University
27 shared publications - Fumio Ito
Chuo University
22 shared publications Rie Nishihama
Research and Development Initiative, Chuo University, 1-13-27 Kasuga, Bunkyo-ku, Tokyo 112-8551, Japan
7 shared publicationsTakashi Kubota
Japan Aerospace Exploration Agency (JAXA)
7 shared publicationsKyota Ashigaki
Chuo University
6 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (12) , 14388-14395
Development of a Series Foot Mechanism for Increased Jumping Performance in Humanoid Robots
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (12) , 14388-14395
Development of a Series Foot Mechanism for Increased Jumping Performance in Humanoid Robots
- Open Access
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 83724-83736
Design and Modeling of a Human-Powered Pneumatic Supply System: Application as a Pneumatic Source for Peristaltic Pumps
This study proposes a manually operated pneumatic supply system that operates without an external power source. Soft robots, known for their high compliance, are increasingly used to be utilized in various fields such as manufacturing, healthcare, and agriculture. However, they often rely on bulky pneumatic systems that require external power, limiting their applicability in extreme environments such as outer space and disaster-stricken areas. To overcome this limitation, this study introduces a pneumatic supply system that eliminates the need for conventional compressors and electric vacuum pumps by utilizing a manually operated pump to pressurize an air tank. A theoretical model was developed to determine the required tank specifications based on the air consumption and operating pressure of the actuator. Furthermore, a model was formulated to estimate the number of manual pumping cycles necessary to achieve the target pressure. Experimental validation identified key parameters and confirmed the model’s accuracy. The results demonstrated that the model is particularly effective for tanks with 1 L or larger. To assess its feasibility in extreme environments, the system was tested using a soft peristaltic pump designed to mimic intestinal peristalsis. The drive experiment verified that the pump successfully completed the target of five cycles, thereby validating the predictions of the model.
- 20 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 83724-83736
Open AccessDesign and Modeling of a Human-Powered Pneumatic Supply System: Application as a Pneumatic Source for Peristaltic Pumps
This study proposes a manually operated pneumatic supply system that operates without an external power source. Soft robots, known for their high compliance, are increasingly used to be utilized in various fields such as manufacturing, healthcare, and agriculture. However, they often rely on bulky pneumatic systems that require external power, limiting their applicability in extreme environments such as outer space and disaster-stricken areas. To overcome this limitation, this study introduces a pneumatic supply system that eliminates the need for conventional compressors and electric vacuum pumps by utilizing a manually operated pump to pressurize an air tank. A theoretical model was developed to determine the required tank specifications based on the air consumption and operating pressure of the actuator. Furthermore, a model was formulated to estimate the number of manual pumping cycles necessary to achieve the target pressure. Experimental validation identified key parameters and confirmed the model’s accuracy. The results demonstrated that the model is particularly effective for tanks with 1 L or larger. To assess its feasibility in extreme environments, the system was tested using a soft peristaltic pump designed to mimic intestinal peristalsis. The drive experiment verified that the pump successfully completed the target of five cycles, thereby validating the predictions of the model.
- 23 February 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (2) , 026003
Content-state-driven motility switching in an intestine-inspired soft-bodied robot via decentralised oscillator networks
Adaptive handling of thick or composition-changing fluids is difficult for conventional pumps. In animals, the intestine addresses this challenge by switching between segmental mixing and peristaltic transport according to the physical state of the contents. We translate this principle into a silicone soft pump composed of four pneumatic chambers, each driven by its own phase oscillator. Two tunable factors govern the collective behaviour: (i) the coupling strength, which attempts to maintain neighbouring oscillators in a travelling-wave relationship, and (ii) the local sensor feedback, which forces each oscillator to correct the deformation error of its own chamber. Numerical bifurcation analysis and time-domain simulations show that when the two strengths are balanced within an intermediate range, the controller first generates an antiphase pattern that homogenises a viscous mixture, and then spontaneously shifts to a quarter-cycle travelling wave that drives the now-fluid contents downstream. We built a physical prototype and experimentally confirmed autonomous mode switching between two glycerol-based fluids of contrasting viscosity. These results demonstrate that a minimal, bioinspired, distributed controller can endow soft devices with adaptive, multifunctional pumping capability, thereby opening new routes to food-processing, biomedical, and chemical-handling systems that operate under uncertain conditions.
- 23 February 2026
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 21 (2) , 026003
Content-state-driven motility switching in an intestine-inspired soft-bodied robot via decentralised oscillator networks
Adaptive handling of thick or composition-changing fluids is difficult for conventional pumps. In animals, the intestine addresses this challenge by switching between segmental mixing and peristaltic transport according to the physical state of the contents. We translate this principle into a silicone soft pump composed of four pneumatic chambers, each driven by its own phase oscillator. Two tunable factors govern the collective behaviour: (i) the coupling strength, which attempts to maintain neighbouring oscillators in a travelling-wave relationship, and (ii) the local sensor feedback, which forces each oscillator to correct the deformation error of its own chamber. Numerical bifurcation analysis and time-domain simulations show that when the two strengths are balanced within an intermediate range, the controller first generates an antiphase pattern that homogenises a viscous mixture, and then spontaneously shifts to a quarter-cycle travelling wave that drives the now-fluid contents downstream. We built a physical prototype and experimentally confirmed autonomous mode switching between two glycerol-based fluids of contrasting viscosity. These results demonstrate that a minimal, bioinspired, distributed controller can endow soft devices with adaptive, multifunctional pumping capability, thereby opening new routes to food-processing, biomedical, and chemical-handling systems that operate under uncertain conditions.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
An Autonomous Decentralized Control System for a Peristaltic Mixing-Pump Utilizing a Flow-Based Smoothing Filter
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- p. 1
Open AccessAn Autonomous Decentralized Control System for a Peristaltic Mixing-Pump Utilizing a Flow-Based Smoothing Filter
- 15 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (11) , 11498-11505
Autonomous Decentralized Control for Motion Switching in an Intestine-Inspired Peristaltic Mixing Pump Adaptive to Physical Phase Transitions of Mixed Materials
In this paper, we developed an autonomous decentralized control method that incorporates phase-difference adjustment based on a sigmoid function, enabling the design of both increases and decreases in discrepancy. The method was applied to a peristaltic mixing pump capable of mixing and transporting solid–liquid multiphase fluids. This study aims to realize a soft robotics system that autonomously switches motion modes according to changes in the physical properties of the transported material, thereby integratively mimicking both the motility and motion-switching functions of the intestine. Conventional autonomous decentralized control methods have been applied to the locomotion of amoeba-type and snake-type robots. However, when such control laws are applied to pumps, it is difficult to achieve appropriate motion switching in environments where the contents harden due to mixing. In this paper, we employed a sigmoid function that allows bidirectional control of discrepancy and constructed a new control law based on target phase-difference adjustment without feedback. The control law was implemented in a four-unit pump, and we confirmed that the desired motion patterns could be reproduced according to the preset target phase differences. As a result, the phase differences between all units converged to the target values within approximately 10–30 s after actuation began, producing the intended motion patterns. Furthermore, polyvinyl alcohol solution and borax water were used as contents whose fluidity decreases during mixing. We verified that autonomous motion switching occurred as the discrepancy increased. The results showed that, in units containing hardened material, a conveying motion with a phase difference of π/3 was generated, whereas in units with residual unmixed material, a mixing motion with a phase difference of π was generated. These findings demonstrate that the proposed method enables motion control that adapts to changes in material properties.
- 15 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (11) , 11498-11505
Autonomous Decentralized Control for Motion Switching in an Intestine-Inspired Peristaltic Mixing Pump Adaptive to Physical Phase Transitions of Mixed Materials
In this paper, we developed an autonomous decentralized control method that incorporates phase-difference adjustment based on a sigmoid function, enabling the design of both increases and decreases in discrepancy. The method was applied to a peristaltic mixing pump capable of mixing and transporting solid–liquid multiphase fluids. This study aims to realize a soft robotics system that autonomously switches motion modes according to changes in the physical properties of the transported material, thereby integratively mimicking both the motility and motion-switching functions of the intestine. Conventional autonomous decentralized control methods have been applied to the locomotion of amoeba-type and snake-type robots. However, when such control laws are applied to pumps, it is difficult to achieve appropriate motion switching in environments where the contents harden due to mixing. In this paper, we employed a sigmoid function that allows bidirectional control of discrepancy and constructed a new control law based on target phase-difference adjustment without feedback. The control law was implemented in a four-unit pump, and we confirmed that the desired motion patterns could be reproduced according to the preset target phase differences. As a result, the phase differences between all units converged to the target values within approximately 10–30 s after actuation began, producing the intended motion patterns. Furthermore, polyvinyl alcohol solution and borax water were used as contents whose fluidity decreases during mixing. We verified that autonomous motion switching occurred as the discrepancy increased. The results showed that, in units containing hardened material, a conveying motion with a phase difference of π/3 was generated, whereas in units with residual unmixed material, a mixing motion with a phase difference of π was generated. These findings demonstrate that the proposed method enables motion control that adapts to changes in material properties.
- 29 August 2025
- Published by Springer Nature
- p. 421-435
Embodiment Under Constant Force Applied by a Force Feedback Device for Spatially Augmented Forearm
- 29 August 2025
- Published by Springer Nature
- p. 421-435
Embodiment Under Constant Force Applied by a Force Feedback Device for Spatially Augmented Forearm
- 2 June 2025
- Published by Taylor & Francis in Advanced Robotics
- Vol. 39 (15) , 936-946
Verification of combined pattern of intermittent pneumatic compression and ankle-assist exercises for preventing deep vein thrombosis
- 2 June 2025
- Published by Taylor & Francis in Advanced Robotics
- Vol. 39 (15) , 936-946
Verification of combined pattern of intermittent pneumatic compression and ankle-assist exercises for preventing deep vein thrombosis
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 6952-6959
HADEC - High-Response Artificial Muscle Actuator Using Dimethyl Ether Combustion
This letter introduces a high-response artificial muscle actuator using dimethyl ether combustion (HADEC), which is a novel method to enhance the responsiveness and force output of pneumatic actuators. The HADEC system integrates a McKibben-type artificial muscle filled with a combustible mixture of dimethyl ether (DME) and air, and it is ignited to generate rapid fluid pressure through combustion. This approach achieves force, displacement, and response speeds comparable to those of biological muscles while maintaining the simplicity and low-cost structure of McKibben-type actuators. The system provides instantaneous force generation without the need for complex mechanisms such as latches or brakes. DME, which is an environment- friendly fuel, ensures minimal emissions. Experimental results validate the effectiveness of HADEC in improving responsiveness, and the findings suggest superior force generation, faster response times, and high-frequency operability compared to that of conventional pneumatic actuators. Further, the paper discusses the potential for repeated actuation and highlights the benefits of HADEC in various robotic applications that require rapid and significant force.
- 23 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (7) , 6952-6959
HADEC - High-Response Artificial Muscle Actuator Using Dimethyl Ether Combustion
This letter introduces a high-response artificial muscle actuator using dimethyl ether combustion (HADEC), which is a novel method to enhance the responsiveness and force output of pneumatic actuators. The HADEC system integrates a McKibben-type artificial muscle filled with a combustible mixture of dimethyl ether (DME) and air, and it is ignited to generate rapid fluid pressure through combustion. This approach achieves force, displacement, and response speeds comparable to those of biological muscles while maintaining the simplicity and low-cost structure of McKibben-type actuators. The system provides instantaneous force generation without the need for complex mechanisms such as latches or brakes. DME, which is an environment- friendly fuel, ensures minimal emissions. Experimental results validate the effectiveness of HADEC in improving responsiveness, and the findings suggest superior force generation, faster response times, and high-frequency operability compared to that of conventional pneumatic actuators. Further, the paper discusses the potential for repeated actuation and highlights the benefits of HADEC in various robotic applications that require rapid and significant force.
- Open Access
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 86-98
Development of a Robot Combining a Hyper-Extension Unit and an Earthworm-Type Robot Enhancing Propulsion and Traction
This paper proposes a robot that combines a hyper-extension unit at the front with an earthworm-type robot at the rear, designed to inspect long, narrow, and complex pipelines. In conventional in-pipe inspection robots with simple designs, there was no mechanism for the robot to effectively exert traction and propulsion while optimizing speed according to the required force. Therefore, this paper describes the development of a robot that combines a hyper-extension unit at the front, which achieves an elongation rate of approximately 300% even at low expansion rates, with an earthworm-type robot at the rear. The developed robot can operate in two patterns: pattern 1 combines the movements of an earthworm and an inchworm, while pattern 2 resembles that of an inchworm. It can switch between speed and force modes by changing its motion pattern. Experimental comparison of the horizontal straight pipe movement speeds of pattern 1 and pattern 2 without and with load showed that pattern 2 was 3.32 times faster than pattern 1 without load and that pattern 1 was 1.51 times faster than pattern 2 with load, clarifying the importance of changing robot’s motion pattern according to the load. The vertical pipe movement speed without load was 3.04 times faster in pattern 2 than in pattern 1. The proposed robot traveled 1.43 times faster than the conventional robot equipped with a conventional spring mechanism when passing through the elbow pipe using pattern 1. However, it could not pass through the elbow pipe using pattern 2, showing the importance of changing the robot’s motion pattern when passing through bent pipes. These results indicate that the proposed robot has the potential to achieve more efficient inspection in long-distance, small-diameter, complex pipes by changing its motion pattern according to the situation in the inspection pipe.
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 86-98
Open AccessDevelopment of a Robot Combining a Hyper-Extension Unit and an Earthworm-Type Robot Enhancing Propulsion and Traction
This paper proposes a robot that combines a hyper-extension unit at the front with an earthworm-type robot at the rear, designed to inspect long, narrow, and complex pipelines. In conventional in-pipe inspection robots with simple designs, there was no mechanism for the robot to effectively exert traction and propulsion while optimizing speed according to the required force. Therefore, this paper describes the development of a robot that combines a hyper-extension unit at the front, which achieves an elongation rate of approximately 300% even at low expansion rates, with an earthworm-type robot at the rear. The developed robot can operate in two patterns: pattern 1 combines the movements of an earthworm and an inchworm, while pattern 2 resembles that of an inchworm. It can switch between speed and force modes by changing its motion pattern. Experimental comparison of the horizontal straight pipe movement speeds of pattern 1 and pattern 2 without and with load showed that pattern 2 was 3.32 times faster than pattern 1 without load and that pattern 1 was 1.51 times faster than pattern 2 with load, clarifying the importance of changing robot’s motion pattern according to the load. The vertical pipe movement speed without load was 3.04 times faster in pattern 2 than in pattern 1. The proposed robot traveled 1.43 times faster than the conventional robot equipped with a conventional spring mechanism when passing through the elbow pipe using pattern 1. However, it could not pass through the elbow pipe using pattern 2, showing the importance of changing the robot’s motion pattern when passing through bent pipes. These results indicate that the proposed robot has the potential to achieve more efficient inspection in long-distance, small-diameter, complex pipes by changing its motion pattern according to the situation in the inspection pipe.
- Open Access
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 172-184
Construction of a Mixing State Estimation System in a Peristaltic Mixing Conveyor that Imitates Intestine —Proposal of an Estimation Method to Improve Generalizability for Mixture’s Input Conditions—
A peristaltic mixing and conveyor that imitates the intestines of living organisms is used to mix powders and highly viscous fluids at low shear force in the manufacturing processes of foods, pharmaceuticals, paints, cosmetics, and other products. Although the device uses sequence control to mix and convey the contents, the actual intestine controls its motion autonomously according to the state of the contents. This research aims to establish an autonomous control method that can change between mixing and conveying according to the state of the mixture. In this paper, we propose a method to construct a learning model that is not affected by the content input conditions, in which samples with different total input amounts and mixing ratios are fed into the device, and sensor values acquired during the device operation are used as training data. The generalizability of the learning model was verified, and it was shown that mixing state estimation was possible up to 20 min from the start of mixing for mixtures with different input amounts and input order.
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 172-184
Open AccessConstruction of a Mixing State Estimation System in a Peristaltic Mixing Conveyor that Imitates Intestine —Proposal of an Estimation Method to Improve Generalizability for Mixture’s Input Conditions—
A peristaltic mixing and conveyor that imitates the intestines of living organisms is used to mix powders and highly viscous fluids at low shear force in the manufacturing processes of foods, pharmaceuticals, paints, cosmetics, and other products. Although the device uses sequence control to mix and convey the contents, the actual intestine controls its motion autonomously according to the state of the contents. This research aims to establish an autonomous control method that can change between mixing and conveying according to the state of the mixture. In this paper, we propose a method to construct a learning model that is not affected by the content input conditions, in which samples with different total input amounts and mixing ratios are fed into the device, and sensor values acquired during the device operation are used as training data. The generalizability of the learning model was verified, and it was shown that mixing state estimation was possible up to 20 min from the start of mixing for mixtures with different input amounts and input order.