Chongkai Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chongkai Fang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Longhua Mu
College of Electronics and Information Engineering, Tongji University, Shanghai, China
9 shared publications - Huaijian Zhao
College of Electronics and Information Engineering, Tongji University, Shanghai, China
2 shared publications - Jiran Zhu
State Grid Hunan Electric Power Company Limited Research Institute, Changsha, China
2 shared publications - Linyi Xue
Department of Electrical Engineering, Tongji University, Shanghai, China
2 shared publications Zihao Wang
Guangxi Transportation Science and Technology Group Co., Ltd., Nanning, China
2 shared publications- Chuhong Wu1 shared publication
Latest Publications
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-12
Active Harmonic Voltage Injection Facilitating Application of Impedance Measurement-Based Protection in Microgrids
A capable and cost-effective protection scheme is essential for the reliable operation of a microgrid. Conventional impedance measurement-based protection is hindered by shorter line lengths, lower line reactance-to-resistance ratios, and fault ride-through (FRT) of inverter-interfaced distributed generators (IIDGs) in microgrids. They are prone to malfunction due to the remote end infeed current during non-metallic faults. This paper addresses this challenge through the coordination of control and protection. IIDGs are configured to actively inject a small harmonic voltage component into the microgrid after fault while coping with FRT requirements using a dual-frequency controller. A hybrid injection activation criterion is embedded to ensure coordinated harmonic injection and equal participation from all IIDGs. Consequently, a uniform harmonic-frequency voltage potential can be generated throughout the microgrid, and its impact on IIDGs' FRT is minimized. The feasibility of the proposed scheme is verified on a hardware-in-the-loop (HIL) experimental platform, and its enhancement to protection performance is validated through theoretical and simulation studies. It is revealed that the proposed control scheme can significantly reduce the fault location error and facilitate the application of single-ended impedance measurement-based protection in microgrids.
- 25 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. PP (08858977) , 1-12
Active Harmonic Voltage Injection Facilitating Application of Impedance Measurement-Based Protection in Microgrids
A capable and cost-effective protection scheme is essential for the reliable operation of a microgrid. Conventional impedance measurement-based protection is hindered by shorter line lengths, lower line reactance-to-resistance ratios, and fault ride-through (FRT) of inverter-interfaced distributed generators (IIDGs) in microgrids. They are prone to malfunction due to the remote end infeed current during non-metallic faults. This paper addresses this challenge through the coordination of control and protection. IIDGs are configured to actively inject a small harmonic voltage component into the microgrid after fault while coping with FRT requirements using a dual-frequency controller. A hybrid injection activation criterion is embedded to ensure coordinated harmonic injection and equal participation from all IIDGs. Consequently, a uniform harmonic-frequency voltage potential can be generated throughout the microgrid, and its impact on IIDGs' FRT is minimized. The feasibility of the proposed scheme is verified on a hardware-in-the-loop (HIL) experimental platform, and its enhancement to protection performance is validated through theoretical and simulation studies. It is revealed that the proposed control scheme can significantly reduce the fault location error and facilitate the application of single-ended impedance measurement-based protection in microgrids.
- 20 November 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 226
Control-based protection design for microgrids: A comprehensive review
- 20 November 2025
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 226
Control-based protection design for microgrids: A comprehensive review
- 13 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
Adaptive current differential protection of line for active distribution networks considering PV output
- 13 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
Adaptive current differential protection of line for active distribution networks considering PV output
- 5 February 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 242
An active or reactive power distribution anomaly detection scheme for marine parallel synchronous generators
- 5 February 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 242
An active or reactive power distribution anomaly detection scheme for marine parallel synchronous generators
- 2 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 209-222
Research on Active Protection Method for Microgrids Based on Harmonic Injection
With the increasing penetration of inverter interfaced distributed generators (IIDGs) in microgrids, traditional protection schemes are difficult to cope with the complexities of microgrids. Harmonic-injected protection schemes based on power electronic devices can simplify the harmonic component equivalent network of the microgrid into a single-source radial structure. However, the performance of these schemes is degraded by the shunt effect of the non-harmonic injection source IIDGs and the utility grid. This paper focuses on the active protection method for microgrids based on harmonic injection. A fault control strategy based on harmonic current control and principles for PCC filter parameter design are proposed to address the shunt effect. With the proposed strategy, harmonic currents of varying frequencies are injected into the microgrid by the IIDGs, and the major portion of the injected harmonic currents can flow to the fault point. By analyzing the fault characteristics, a fault location method based on harmonic injection is proposed. Finally, simulation analysis is carried out on MATLAB/Simulink platform, and the effectiveness of the proposed active protection scheme is verified by the results.
- 2 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (1) , 209-222
Research on Active Protection Method for Microgrids Based on Harmonic Injection
With the increasing penetration of inverter interfaced distributed generators (IIDGs) in microgrids, traditional protection schemes are difficult to cope with the complexities of microgrids. Harmonic-injected protection schemes based on power electronic devices can simplify the harmonic component equivalent network of the microgrid into a single-source radial structure. However, the performance of these schemes is degraded by the shunt effect of the non-harmonic injection source IIDGs and the utility grid. This paper focuses on the active protection method for microgrids based on harmonic injection. A fault control strategy based on harmonic current control and principles for PCC filter parameter design are proposed to address the shunt effect. With the proposed strategy, harmonic currents of varying frequencies are injected into the microgrid by the IIDGs, and the major portion of the injected harmonic currents can flow to the fault point. By analyzing the fault characteristics, a fault location method based on harmonic injection is proposed. Finally, simulation analysis is carried out on MATLAB/Simulink platform, and the effectiveness of the proposed active protection scheme is verified by the results.
- Open Access
- 1 April 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (4)
Fault response analysis and comprehensive modeling for renewable energy microgrids consisting of virtual synchronous generators
Virtual synchronous generators (VSGs) have considerable potential to be applied in renewable energy microgrid systems because they provide inertia and damping, thus improving system stability. However, the fault characteristics of renewable energy microgrids differ from those of conventional grids. Consequently, investigating the fault responses of VSGs and establishing the associated fault model would significantly enhance the fault calculation and protection mechanism design in renewable energy microgrids. This paper briefly introduces the VSG control principles and fault control strategy before establishing the corresponding transient- and steady-state VSG fault models and calculating the model parameters. For simplicity, the fault model is linearized at the steady-state estimation point and semi-decoupled for the computation of the voltage amplitude and power angle. Finally, the results from MATLAB/Simulink simulations are compared with those from the proposed fault models, and the influence of the system parameters on the model is discussed. The results demonstrate the validity, simplicity, intuitiveness, and broad applicability of our approach.
- 1 April 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (4)
Open AccessFault response analysis and comprehensive modeling for renewable energy microgrids consisting of virtual synchronous generators
Virtual synchronous generators (VSGs) have considerable potential to be applied in renewable energy microgrid systems because they provide inertia and damping, thus improving system stability. However, the fault characteristics of renewable energy microgrids differ from those of conventional grids. Consequently, investigating the fault responses of VSGs and establishing the associated fault model would significantly enhance the fault calculation and protection mechanism design in renewable energy microgrids. This paper briefly introduces the VSG control principles and fault control strategy before establishing the corresponding transient- and steady-state VSG fault models and calculating the model parameters. For simplicity, the fault model is linearized at the steady-state estimation point and semi-decoupled for the computation of the voltage amplitude and power angle. Finally, the results from MATLAB/Simulink simulations are compared with those from the proposed fault models, and the influence of the system parameters on the model is discussed. The results demonstrate the validity, simplicity, intuitiveness, and broad applicability of our approach.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3706-3721
Analytical Fault Modeling of Droop-Controlled IIDG and its Cluster
Fault modeling of inverter-interfaced distributed generators (IIDGs) is the basis of power system fault calculation and protection scheme design. Due to its inherent properties and flexible control strategy, analyzing the transient-state fault responses of droop-controlled IIDG is difficult, and an analytical fault model has yet to be proposed. This work establishes a controlled voltage source-based fault equivalent model of droop-controlled IIDG in synchronous reference frame to address this research gap. The impacts of droop characteristics, virtual impedance, double-closed-loop controller, current limiting, and low-voltage-ride-through requirements are all considered, and the obtained model can cover both the transient- and steady-state fault responses. An IIDG clustering method based on the equivalent admittance matrix of the grid is also proposed, which lays the groundwork for model reduction. A corresponding model aggregation method is then provided. With this, the complexity of fault analysis for peer-to-peer controlled distributed power systems can be significantly reduced. The scheme proposed in this paper is verified by simulation experiments in PSCAD/EMTDC software.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3706-3721
Analytical Fault Modeling of Droop-Controlled IIDG and its Cluster
Fault modeling of inverter-interfaced distributed generators (IIDGs) is the basis of power system fault calculation and protection scheme design. Due to its inherent properties and flexible control strategy, analyzing the transient-state fault responses of droop-controlled IIDG is difficult, and an analytical fault model has yet to be proposed. This work establishes a controlled voltage source-based fault equivalent model of droop-controlled IIDG in synchronous reference frame to address this research gap. The impacts of droop characteristics, virtual impedance, double-closed-loop controller, current limiting, and low-voltage-ride-through requirements are all considered, and the obtained model can cover both the transient- and steady-state fault responses. An IIDG clustering method based on the equivalent admittance matrix of the grid is also proposed, which lays the groundwork for model reduction. A corresponding model aggregation method is then provided. With this, the complexity of fault analysis for peer-to-peer controlled distributed power systems can be significantly reduced. The scheme proposed in this paper is verified by simulation experiments in PSCAD/EMTDC software.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (2) , 1187-1199
Analysis of Grid-Forming IIDG’s Transient- and Steady-State Fault Model
Due to the inherent characteristics of inverter- interfaced distributed generators (IIDG), their fault responses are different from those of conventional synchronous generators. Investigating fault responses of IIDGs and establishing their fault models will benefit the fault calculation and protection scheme design for microgrids. This paper focuses on grid-forming IIDGs (GFGs) and hierarchically analyzes their fault characteristics under symmetrical and asymmetrical faults. A generic fault model of GFG, which covers both the transient- and steady-state, is proposed. Impacts of the transfer function of controllers, the current limiting module, and the fluctuation of DC-link voltage on GFG’s transient- and steady-state fault responses are respectively investigated. The influence of GFG’s topology is also considered, and both three-phase three-wire and three-phase four-wire GFGs are covered in the fault analysis. Model parameters calculation methods for all kinds of fault conditions are presented. It is found that the fault type, the fault severity, and the response speed of the DC power regulator all have significant impacts on GFG’s fault responses. The fault analysis and fault model are verified by simulation results in MATLAB/Simulink.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (2) , 1187-1199
Analysis of Grid-Forming IIDG’s Transient- and Steady-State Fault Model
Due to the inherent characteristics of inverter- interfaced distributed generators (IIDG), their fault responses are different from those of conventional synchronous generators. Investigating fault responses of IIDGs and establishing their fault models will benefit the fault calculation and protection scheme design for microgrids. This paper focuses on grid-forming IIDGs (GFGs) and hierarchically analyzes their fault characteristics under symmetrical and asymmetrical faults. A generic fault model of GFG, which covers both the transient- and steady-state, is proposed. Impacts of the transfer function of controllers, the current limiting module, and the fluctuation of DC-link voltage on GFG’s transient- and steady-state fault responses are respectively investigated. The influence of GFG’s topology is also considered, and both three-phase three-wire and three-phase four-wire GFGs are covered in the fault analysis. Model parameters calculation methods for all kinds of fault conditions are presented. It is found that the fault type, the fault severity, and the response speed of the DC power regulator all have significant impacts on GFG’s fault responses. The fault analysis and fault model are verified by simulation results in MATLAB/Simulink.