Defu Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Defu Cheng has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Jing Zhao
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
6 shared publications - Yanzhang Wang
State Key Laboratory of Deep Earth Exploration and Imaging and the College of Instrumentation and Electrical Engineering Department, Jilin University, Changchun, China
5 shared publications - Liangguang Yue
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
4 shared publications - Zhijian Zhou
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
4 shared publications - Chen Chen
College of Instrumentation and Electrical Engineering, Key Laboratory of Geophysical Exploration Equipment, Ministry of Education of China, Jilin University, Changchun, China
3 shared publications - Heng Piao
College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
3 shared publications
Latest Publications
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23  (10) , 10694-10705
Compensation Method for the Carrier Magnetic Interference of Underwater Magnetic Vector Measurement System
This paper proposed a new compensation method of underwater magnetic vector measurement system which innovatively using the geomagnetic total field as benchmark. Moreover, this method does not require the use of heading angle data in the calculation of the compensation parameters, which avoids errors caused by insufficient accuracy of underwater heading angle. The implementation of these features relies on the new objective function constructed according to the characteristics of the spatial projection of the magnetic vector field on the horizontal plane of the geographical coordinate. The core matrix of the geomagnetic vector ellipsoid model is used as a constraint to determine the range of function solutions. The Levenberg-Marquardt algorithm is used to find the optimal solution to the new objective function. Three experiments were carried out to verify the proposed method. In simulation experiment, the deviation between the calculated value and the preset value is less than 0.01%. In field experiment, the standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 1527.38nT, 1397.35nT, 1529.16nT, 574.94nT to 9.86nT (0.65%), 9.99nT (0.72%), 5.63nT (0.38%), 2.14nT (0.37%). The proposed method is finally verified by marine experiment. The standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 575.02 nT, 830.60 nT, 620.95 nT, 1702.35 nT to 17.43 nT (1.11%), 14.14 nT (1.70%), 25.17nT (4.10%), 7.18 nT (0.42%).
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23  (10) , 10694-10705
Compensation Method for the Carrier Magnetic Interference of Underwater Magnetic Vector Measurement System
This paper proposed a new compensation method of underwater magnetic vector measurement system which innovatively using the geomagnetic total field as benchmark. Moreover, this method does not require the use of heading angle data in the calculation of the compensation parameters, which avoids errors caused by insufficient accuracy of underwater heading angle. The implementation of these features relies on the new objective function constructed according to the characteristics of the spatial projection of the magnetic vector field on the horizontal plane of the geographical coordinate. The core matrix of the geomagnetic vector ellipsoid model is used as a constraint to determine the range of function solutions. The Levenberg-Marquardt algorithm is used to find the optimal solution to the new objective function. Three experiments were carried out to verify the proposed method. In simulation experiment, the deviation between the calculated value and the preset value is less than 0.01%. In field experiment, the standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 1527.38nT, 1397.35nT, 1529.16nT, 574.94nT to 9.86nT (0.65%), 9.99nT (0.72%), 5.63nT (0.38%), 2.14nT (0.37%). The proposed method is finally verified by marine experiment. The standard deviation value of x, y, z magnetic components and the root mean square error of magnetic total field after compensation are reduced from 575.02 nT, 830.60 nT, 620.95 nT, 1702.35 nT to 17.43 nT (1.11%), 14.14 nT (1.70%), 25.17nT (4.10%), 7.18 nT (0.42%).
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23  (7) , 6706-6716
Fast Error Calibration for Three-Axis SQUID Magnetometers Based on Full-Space Rotational and Frequency-Controllable Magnetic Field
In order to overcome the limitations of the traditional error calibration method for three-axis superconducting quantum interference device (SQUID) magnetometers. This paper presents a fast error calibration method for three-axis SQUID magnetometers. In the proposed method, a full-space rotational and frequency-controllable magnetic field with constant total field intensity can be generated by triaxial Helmholtz coil. Meanwhile, the non-orthogonal error, zero offset error and proportional coefficient error of the three-axis SQUID magnetometers which measure the relative value rather than the absolute value can be accurately solved by error modeling and ellipsoid fitting theory. Compared with the traditional scalar calibration method, this method replaces the rotation of Dewar and three-axis SQUID magnetometers with a rotating magnetic field, thus avoiding the interference and influence of motion. Compared with the traditional vector calibration method, this method does not need to ensure the alignment between the three-axis SQUID magnetometers and triaxial Helmholtz coil. Moreover, the interference of low frequency magnetic field can be suppressed by shortening the period of rotating magnetic field. Simulation and experiments prove the effectiveness of this method. After calibration by the proposed method, the root mean square error is reduced to 0.414 nT from 138.411 nT in electromagnetic shielding room. Repetitive and comparative experiments with the traditional method in field also prove the superiority and stability of the proposed method.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23  (7) , 6706-6716
Fast Error Calibration for Three-Axis SQUID Magnetometers Based on Full-Space Rotational and Frequency-Controllable Magnetic Field
In order to overcome the limitations of the traditional error calibration method for three-axis superconducting quantum interference device (SQUID) magnetometers. This paper presents a fast error calibration method for three-axis SQUID magnetometers. In the proposed method, a full-space rotational and frequency-controllable magnetic field with constant total field intensity can be generated by triaxial Helmholtz coil. Meanwhile, the non-orthogonal error, zero offset error and proportional coefficient error of the three-axis SQUID magnetometers which measure the relative value rather than the absolute value can be accurately solved by error modeling and ellipsoid fitting theory. Compared with the traditional scalar calibration method, this method replaces the rotation of Dewar and three-axis SQUID magnetometers with a rotating magnetic field, thus avoiding the interference and influence of motion. Compared with the traditional vector calibration method, this method does not need to ensure the alignment between the three-axis SQUID magnetometers and triaxial Helmholtz coil. Moreover, the interference of low frequency magnetic field can be suppressed by shortening the period of rotating magnetic field. Simulation and experiments prove the effectiveness of this method. After calibration by the proposed method, the root mean square error is reduced to 0.414 nT from 138.411 nT in electromagnetic shielding room. Repetitive and comparative experiments with the traditional method in field also prove the superiority and stability of the proposed method.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33  (3) , 1-10
Error Calibration for Crosstalk of SQUIDs in Full Tensor Magnetic Gradiometer Based on Moore–Penrose Inverse and Helmholtz Coil
In order to calibrate crosstalk error between Superconducting Quantum Interference Device (SQUID) magnetometers in a multichannel SQUID system. We propose an innovative error calibration method for crosstalk of SQUIDmagnetometers based on the Moore-Penrose inverse method and Helmholtz coil in this article and successfully apply it to an 8-channel SQUID magnetometers-based full tensor magnetic gradiometer (FTMG). We first analyze the causes of crosstalk through working principle of the SQUID readout circuit, and build the crosstalk error model of 8-channel FTMG. Then we introduce the solution method of 56 crosstalk coefficients based on Moore-Penrose inverse method and construction method of matrix needed for solution based on Helmholtz coil. The effect of non-uniformity of Helmholtz coil on calibration of crosstalk is analyzed and calculated. The effectiveness of the proposed method is proved by repetitive simulation and comparative experiments. Compared with the traditional direct measurement method, this method has the advantage of high efficiency, and the more channels of SQUID, the more obvious the superiority.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33  (3) , 1-10
Error Calibration for Crosstalk of SQUIDs in Full Tensor Magnetic Gradiometer Based on Moore–Penrose Inverse and Helmholtz Coil
In order to calibrate crosstalk error between Superconducting Quantum Interference Device (SQUID) magnetometers in a multichannel SQUID system. We propose an innovative error calibration method for crosstalk of SQUIDmagnetometers based on the Moore-Penrose inverse method and Helmholtz coil in this article and successfully apply it to an 8-channel SQUID magnetometers-based full tensor magnetic gradiometer (FTMG). We first analyze the causes of crosstalk through working principle of the SQUID readout circuit, and build the crosstalk error model of 8-channel FTMG. Then we introduce the solution method of 56 crosstalk coefficients based on Moore-Penrose inverse method and construction method of matrix needed for solution based on Helmholtz coil. The effect of non-uniformity of Helmholtz coil on calibration of crosstalk is analyzed and calculated. The effectiveness of the proposed method is proved by repetitive simulation and comparative experiments. Compared with the traditional direct measurement method, this method has the advantage of high efficiency, and the more channels of SQUID, the more obvious the superiority.
- 26 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-11
Error Calibration for Full Tensor Magnetic Gradiometer Probe Based on Coordinate Transformation Method
In order to calibrate the zero offset error and triaxial nonorthogonal error of full tensor magnetic gradiometer (FTMG) probe composed of superconducting quantum interference device (SQUID) magnetometers, we propose a new calibration method in this article. With the help of the triaxial Helmholtz coil, we can generate a magnetic field with known parameters. By establishing the objective functions containing the error parameters for the outputs of the SQUIDs and solving them with the least-squares fitting algorithm, the included angle between the SQUID sensor and the Helmholtz coil can be obtained; then, all the required error parameters can be calculated by coordinate transformation method. Compared with the traditional method, this method does not need to rotate the SQUID magnetometers-based probe to collect the dataset for calibration, thus avoiding the influence of motion-induced noise on the calibration results. In order to verify the effectiveness of the proposed method, we adopted the widely used ellipsoid fitting method as a comparison method and conducted field comparison experiments. The results show that the proposed calibration method is better than the traditional ellipsoid fitting calibration method under the same experimental environment. The root mean square errors of five independent magnetic gradient tensor components are reduced to 0.39, 0.35, 0.41, 0.31, and 0.57 nT/m from 1630.55, 756.59, 3097.56, 1051.09, and 1245.64 nT/m by the proposed method.
- 26 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-11
Error Calibration for Full Tensor Magnetic Gradiometer Probe Based on Coordinate Transformation Method
In order to calibrate the zero offset error and triaxial nonorthogonal error of full tensor magnetic gradiometer (FTMG) probe composed of superconducting quantum interference device (SQUID) magnetometers, we propose a new calibration method in this article. With the help of the triaxial Helmholtz coil, we can generate a magnetic field with known parameters. By establishing the objective functions containing the error parameters for the outputs of the SQUIDs and solving them with the least-squares fitting algorithm, the included angle between the SQUID sensor and the Helmholtz coil can be obtained; then, all the required error parameters can be calculated by coordinate transformation method. Compared with the traditional method, this method does not need to rotate the SQUID magnetometers-based probe to collect the dataset for calibration, thus avoiding the influence of motion-induced noise on the calibration results. In order to verify the effectiveness of the proposed method, we adopted the widely used ellipsoid fitting method as a comparison method and conducted field comparison experiments. The results show that the proposed calibration method is better than the traditional ellipsoid fitting calibration method under the same experimental environment. The root mean square errors of five independent magnetic gradient tensor components are reduced to 0.39, 0.35, 0.41, 0.31, and 0.57 nT/m from 1630.55, 756.59, 3097.56, 1051.09, and 1245.64 nT/m by the proposed method.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-12
A Temperature Gradient Field Compensation Method to Improve the Accuracy of the CO2 Carbon Isotope Sensor
Accurate measurement of carbon isotope abundance is extremely important for geochemical applications. In the seismic zone, measurement error caused by variable gas temperature must be compensated. In this study, a 13 CO 2 carbon isotope abundance sensor using temperature gradient field compensation (TGFC) method is investigated to improve the accuracy of isotope abundance measurement. The theoretical model of sensor is combined with TGFC method to provide a theoretical method for compensating the errors caused by temperature gradient field. When measuring isotopic abundance using the TGFC method, the reference temperature gradient field of the measured gas is obtained through heat transfer analysis and indirect measurement. The reference temperature gradient field of the measured gas is obtained through heat transfer analysis and indirect measurement for sensor measurement using TGFC method. The error of the sensor in $\delta ^{13}\text{C}$ (CO 2 ) is 0.183‰. Two days of tests are conducted to verify the sensor’s performance at the Fengman seismic station. The results validate the ability of the sensor to measure gas isotope abundances in seismic regions for geochemical analysis.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-12
A Temperature Gradient Field Compensation Method to Improve the Accuracy of the CO2 Carbon Isotope Sensor
Accurate measurement of carbon isotope abundance is extremely important for geochemical applications. In the seismic zone, measurement error caused by variable gas temperature must be compensated. In this study, a 13 CO 2 carbon isotope abundance sensor using temperature gradient field compensation (TGFC) method is investigated to improve the accuracy of isotope abundance measurement. The theoretical model of sensor is combined with TGFC method to provide a theoretical method for compensating the errors caused by temperature gradient field. When measuring isotopic abundance using the TGFC method, the reference temperature gradient field of the measured gas is obtained through heat transfer analysis and indirect measurement. The reference temperature gradient field of the measured gas is obtained through heat transfer analysis and indirect measurement for sensor measurement using TGFC method. The error of the sensor in $\delta ^{13}\text{C}$ (CO 2 ) is 0.183‰. Two days of tests are conducted to verify the sensor’s performance at the Fengman seismic station. The results validate the ability of the sensor to measure gas isotope abundances in seismic regions for geochemical analysis.
- 6 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-9
A High-Accuracy CO2 Carbon Isotope Sensing System Using Subspace Identification of Hammerstein Model for Geochemical Application
In geochemical applications, carbon dioxide isotope abundance should be accurately measured. However, many challenges must be overcome in field applications, such as the interference from harsh environment or the influence of various underground overflow gases. In this study, a CO 2 carbon isotope sensing system using subspace identification of Hammerstein model (SIHM) was investigated to achieve better accuracy than the current method in terms of measurement performance. An improved nonlinear model is adopted in the sensing system, and the model is accurately obtained by the recursive least-square and singular value decomposition (SVD) methods. Meanwhile, the noise of the system is reduced according to the matrix projection principle. The accuracy of 13 CO 2 isotope detection is 0.210 ‰, and the precision of 13 CO 2 isotope is low, that is, 0.043 ‰, with an integration time of 504 s. The sensing system was tested at Fengman seismic station for two days. The system worked well and could reflect the geological activity. The results validate the ability of the sensing system to measure isotopic abundance in geochemical applications.
- 6 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-9
A High-Accuracy CO2 Carbon Isotope Sensing System Using Subspace Identification of Hammerstein Model for Geochemical Application
In geochemical applications, carbon dioxide isotope abundance should be accurately measured. However, many challenges must be overcome in field applications, such as the interference from harsh environment or the influence of various underground overflow gases. In this study, a CO 2 carbon isotope sensing system using subspace identification of Hammerstein model (SIHM) was investigated to achieve better accuracy than the current method in terms of measurement performance. An improved nonlinear model is adopted in the sensing system, and the model is accurately obtained by the recursive least-square and singular value decomposition (SVD) methods. Meanwhile, the noise of the system is reduced according to the matrix projection principle. The accuracy of 13 CO 2 isotope detection is 0.210 ‰, and the precision of 13 CO 2 isotope is low, that is, 0.043 ‰, with an integration time of 504 s. The sensing system was tested at Fengman seismic station for two days. The system worked well and could reflect the geological activity. The results validate the ability of the sensing system to measure isotopic abundance in geochemical applications.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-10
A Prototype of CH4 and CO2 Sensing System Using State Parameters Correction Applied to Gas Geochemical Exploration
A seismic activity monitoring instrument is required in gas geochemical exploration to measure methane (CH4) and carbon dioxide (CO2) near the geological fault zone. A prototype of CH4 and CO2 sensing system based on wavelength modulation spectroscopy, which can achieve a high-accuracy, wide-range, and in-situ measurement, is developed. An environment-adaptive temperature control system, which can ensure temperature stability and reduce power consumption by changing the target temperature according to the environment temperature, is proposed to adopt the sensing system to in-situ environments. A state parameters correction (SPC) method based on black box theory is proposed to improve measurement accuracy, which is used to correct gas temperature and pressure, effective optical path length, initial light intensity, and constant associated with the system. Gas temperature and pressure are corrected according to the difference between target temperature and calibration temperature. The effective optical path length is corrected using target temperature and initial light intensity. Constants associated with the system are measured using the same gas at different target temperatures. A combination of the four absorption lines at 4979.48, 4979.78, 4293.53, and 4293.59 cm-1 combined with time division multiplexing is utilized to realize wide-range measurement. The measurement accuracy of the sensing system is better than 1% in the environment temperature range from 0 °C to 35 °C. The optimal minimum detection limits (MDL) are 0.087 ppmv for CH4 and 7.8 ppmv for CO2 when the integration times are 225 s and 51 s, respectively. A test is performed in the cave in the center of Fengman Seismic Station using the sensing system to monitor CH4 and CO2. The maximum deviations of three measurements for the same gas are less than 3.9‰ for CH4 and 8‰ for CO2. The measured concentration ranges are from 2475 ppmv to 2950 ppmv for CO2 and from 135 ppmv to 137 ppmv for CH4, validating the working performance of the sensing system applied to gas geochemical exploration.
- 1 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71  (00189456) , 1-10
A Prototype of CH4 and CO2 Sensing System Using State Parameters Correction Applied to Gas Geochemical Exploration
A seismic activity monitoring instrument is required in gas geochemical exploration to measure methane (CH4) and carbon dioxide (CO2) near the geological fault zone. A prototype of CH4 and CO2 sensing system based on wavelength modulation spectroscopy, which can achieve a high-accuracy, wide-range, and in-situ measurement, is developed. An environment-adaptive temperature control system, which can ensure temperature stability and reduce power consumption by changing the target temperature according to the environment temperature, is proposed to adopt the sensing system to in-situ environments. A state parameters correction (SPC) method based on black box theory is proposed to improve measurement accuracy, which is used to correct gas temperature and pressure, effective optical path length, initial light intensity, and constant associated with the system. Gas temperature and pressure are corrected according to the difference between target temperature and calibration temperature. The effective optical path length is corrected using target temperature and initial light intensity. Constants associated with the system are measured using the same gas at different target temperatures. A combination of the four absorption lines at 4979.48, 4979.78, 4293.53, and 4293.59 cm-1 combined with time division multiplexing is utilized to realize wide-range measurement. The measurement accuracy of the sensing system is better than 1% in the environment temperature range from 0 °C to 35 °C. The optimal minimum detection limits (MDL) are 0.087 ppmv for CH4 and 7.8 ppmv for CO2 when the integration times are 225 s and 51 s, respectively. A test is performed in the cave in the center of Fengman Seismic Station using the sensing system to monitor CH4 and CO2. The maximum deviations of three measurements for the same gas are less than 3.9‰ for CH4 and 8‰ for CO2. The measured concentration ranges are from 2475 ppmv to 2950 ppmv for CO2 and from 135 ppmv to 137 ppmv for CH4, validating the working performance of the sensing system applied to gas geochemical exploration.
- Open Access
- 25 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10  (19) , 6707
An Improved Calibration Method for the Misalignment Error of a Triaxial Magnetometer and Inertial Navigation System in a Three-Component Magnetic Survey System
In order to calibrate the misalignment error of a triaxial magnetometer and an inertial navigation system in a three-component magnetic survey system, an improved method with easy realization is proposed in this paper. We establish the misalignment error model based on Euler’s theorem. We transform the calibration of misalignment error into estimating calibration parameters to minimize the value of objective function. Then, the nonlinear least squares method is used to estimate the calibration parameters. In the simulation experiment, the deviation between the value and the preset value is within 1 nT. In the field experiment, the fluctuation value of the x, y, and z components reduce to 1.09%, 0.92%, and 1.28%, respectively. The absolute deviation values are reduced to 0.72%, 0.70%, and 0.81% and the standard deviation value are reduced to 0.74%, 0.71%, 0.86%, respectively. The proposed method has advantages of high operability and precision as compared with existing methods.
- 25 September 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10  (19) , 6707
Open AccessAn Improved Calibration Method for the Misalignment Error of a Triaxial Magnetometer and Inertial Navigation System in a Three-Component Magnetic Survey System
In order to calibrate the misalignment error of a triaxial magnetometer and an inertial navigation system in a three-component magnetic survey system, an improved method with easy realization is proposed in this paper. We establish the misalignment error model based on Euler’s theorem. We transform the calibration of misalignment error into estimating calibration parameters to minimize the value of objective function. Then, the nonlinear least squares method is used to estimate the calibration parameters. In the simulation experiment, the deviation between the value and the preset value is within 1 nT. In the field experiment, the fluctuation value of the x, y, and z components reduce to 1.09%, 0.92%, and 1.28%, respectively. The absolute deviation values are reduced to 0.72%, 0.70%, and 0.81% and the standard deviation value are reduced to 0.74%, 0.71%, 0.86%, respectively. The proposed method has advantages of high operability and precision as compared with existing methods.
- Open Access
- 3 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10  (3) , 986
Compensation Method for Diurnal Variation in Three-Component Magnetic Survey
Considering that diurnal variation interferes with three-component magnetic surveys, which inevitably affects survey accuracy, exploring an interference compensation method of high-precision is particularly desirable. In this paper, a compensation method for diurnal variation is proposed, the procedure of which involves calibrating the magnetometer error and the misalignment error between magnetometer and non-magnetic theodolite. Meanwhile, the theodolite is used to adjust the attitude of the magnetometer to unify the observed diurnal variation into the geographic coordinate system. Thereafter, the feasibility and validity of the proposed method were verified by field experiments. The experimental results show that the average error of each component between the observed value of the proposed method and that of Changchun Geomagnetic station is less than 1.2 nT, which indicates that the proposed method achieves high observation accuracy. The proposed method can make up for the deficiency that traditional methods cannot meet the requirements of high accuracy diurnal variation compensation. With this method, it is possible for us to set up temporary diurnal variation observation station in areas with complex topography and harsh environment to assist aeromagnetic three-component survey.
- 3 February 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10  (3) , 986
Open AccessCompensation Method for Diurnal Variation in Three-Component Magnetic Survey
Considering that diurnal variation interferes with three-component magnetic surveys, which inevitably affects survey accuracy, exploring an interference compensation method of high-precision is particularly desirable. In this paper, a compensation method for diurnal variation is proposed, the procedure of which involves calibrating the magnetometer error and the misalignment error between magnetometer and non-magnetic theodolite. Meanwhile, the theodolite is used to adjust the attitude of the magnetometer to unify the observed diurnal variation into the geographic coordinate system. Thereafter, the feasibility and validity of the proposed method were verified by field experiments. The experimental results show that the average error of each component between the observed value of the proposed method and that of Changchun Geomagnetic station is less than 1.2 nT, which indicates that the proposed method achieves high observation accuracy. The proposed method can make up for the deficiency that traditional methods cannot meet the requirements of high accuracy diurnal variation compensation. With this method, it is possible for us to set up temporary diurnal variation observation station in areas with complex topography and harsh environment to assist aeromagnetic three-component survey.
- Open Access
- 1 March 2018
- Published by Walter de Gruyter GmbH in Artificial Satellites
- Vol. 53  (1) , 47-53
A New Method for Measuring Angular Increments Based on a Tri-Axial Accelerometer and a Tri-Axial Magnetometer
Tri-axial gyroscopes used to be the only instrument used to measure the angular increments of airplanes. However, because there were no reference devices, drift and accumulation errors affected the accuracy of the estimated attitude. In this paper, we propose a novel method for measuring angular increments based on a tri-axial accelerometer and a triaxial magnetometer. Then, we mathematically proved the feasibility of the proposed method. The results of our simulation and experimental tests indicated that the proposed method accurately indicates the attitude of an airplane.
- 1 March 2018
- Published by Walter de Gruyter GmbH in Artificial Satellites
- Vol. 53  (1) , 47-53
Open AccessA New Method for Measuring Angular Increments Based on a Tri-Axial Accelerometer and a Tri-Axial Magnetometer
Tri-axial gyroscopes used to be the only instrument used to measure the angular increments of airplanes. However, because there were no reference devices, drift and accumulation errors affected the accuracy of the estimated attitude. In this paper, we propose a novel method for measuring angular increments based on a tri-axial accelerometer and a triaxial magnetometer. Then, we mathematically proved the feasibility of the proposed method. The results of our simulation and experimental tests indicated that the proposed method accurately indicates the attitude of an airplane.