Zhigang Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhigang Sun has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jiabin Wang
University of Sheffield, Sheffield, U.K.
3 shared publications - Andrew Robert Mills
School of Electrical and Electronic Engineering, University of Sheffield, Sheffield, UK
2 shared publications Ellis Chong
Rolls-Royce plc, Derby, United Kingdom
2 shared publications- Rongguang Hu
The University of Sheffield, Sheffield, United Kingdom
2 shared publications - Ge Han
Key Laboratory of Light-Duty Gas-Turbine;, Institute of Engineering Thermophysics;, Chinese Academy of Sciences, University of Chinese Academy of Sciences, Beijing 100190, China
1 shared publication Jinfeng Huang
National Univ. of Defense Technology (China)
1 shared publication
Latest Publications
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 107, 72
BOPA: a traffic planning algorithm for minimizing buffer resources for onboard TSN switching
SPIE Digital Library Proceedings
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 107, 72
BOPA: a traffic planning algorithm for minimizing buffer resources for onboard TSN switching
SPIE Digital Library Proceedings
- Open Access
- 25 February 2022
- Published by Hindawi Limited in International Journal of Aerospace Engineering
- Vol. 2022, 1-16
Investigation of New Design Principles for the Centrifugal Compressor Vaned Diffusers
Diffusers aerodynamic performance is crucial for the centrifugal compressors, while at present the universal principles for the optimization design of the vaned diffusers are still not available. In this paper, three vaned diffusers with different inlet Mach numbers were numerically studied in order to explore new design principles for the centrifugal compressor vaned diffusers. It proved that there are practical and effective design principles for the vaned diffuser optimizations, the performance of the vaned diffuser can be improved by carefully control of two aerodynamic parameter distributions: Tangential velocity (Vt) and Meridional velocity (Vm). The vaned diffusers with subsonic, transonic and supersonic inlet conditions were optimized with the new design principles, and the peak efficiencies were increased by 4.23, 2.15 and 2.59, respectively. The stage pressure ratios were increased by 3.36, 1.39 and 6.49, respectively, and their surge margins were also improved substantially. Finally, since the Vt and Vm could affect each other during the optimization process, an interactive optimization design procedure was also presented in this paper in order to accelerate the optimization process.
- 25 February 2022
- Published by Hindawi Limited in International Journal of Aerospace Engineering
- Vol. 2022, 1-16
Open AccessInvestigation of New Design Principles for the Centrifugal Compressor Vaned Diffusers
Diffusers aerodynamic performance is crucial for the centrifugal compressors, while at present the universal principles for the optimization design of the vaned diffusers are still not available. In this paper, three vaned diffusers with different inlet Mach numbers were numerically studied in order to explore new design principles for the centrifugal compressor vaned diffusers. It proved that there are practical and effective design principles for the vaned diffuser optimizations, the performance of the vaned diffuser can be improved by carefully control of two aerodynamic parameter distributions: Tangential velocity (Vt) and Meridional velocity (Vm). The vaned diffusers with subsonic, transonic and supersonic inlet conditions were optimized with the new design principles, and the peak efficiencies were increased by 4.23, 2.15 and 2.59, respectively. The stage pressure ratios were increased by 3.36, 1.39 and 6.49, respectively, and their surge margins were also improved substantially. Finally, since the Vt and Vm could affect each other during the optimization process, an interactive optimization design procedure was also presented in this paper in order to accelerate the optimization process.
- Open Access
- 16 April 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (17) , 4426-4431
Electromagnetic‐thermal coupled modelling and analysis of inter‐turn short‐circuit faults of a permanent magnet alternator
This paper describes a computationally efficient model for predicting transient and steady‐state behaviours of a permanent magnet alternator (PMA) connected to an asymmetric PWM rectifier and load in aerospace applications under healthy and fault conditions. The model is validated by finite element and circuit coupled co‐simulation. The developed model is used to predict the PMA performance under fault conditions and to identify fault signatures that can be exploited for the development of fault detection techniques. The developed electric model is coupled to the thermal model to predict hotspot temperature of the winding under the worst case inter‐turn short‐circuit condition and to estimate the winding lifetime.
- 16 April 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (17) , 4426-4431
Open AccessElectromagnetic‐thermal coupled modelling and analysis of inter‐turn short‐circuit faults of a permanent magnet alternator
This paper describes a computationally efficient model for predicting transient and steady‐state behaviours of a permanent magnet alternator (PMA) connected to an asymmetric PWM rectifier and load in aerospace applications under healthy and fault conditions. The model is validated by finite element and circuit coupled co‐simulation. The developed model is used to predict the PMA performance under fault conditions and to identify fault signatures that can be exploited for the development of fault detection techniques. The developed electric model is coupled to the thermal model to predict hotspot temperature of the winding under the worst case inter‐turn short‐circuit condition and to estimate the winding lifetime.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
PWM ripple currents based turn fault detection for 3-phase permanent magnet machines
Most permanent magnet (PM) machines are driven by inverter with pulse-width-modulation (PWM) voltages. The resultant phase current contains high frequency (HF) components, based on which, a new technique to detect turn fault is proposed. The machine model at high frequency is established and the HF current components are analyzed. A bandpass filter is used to extract the selected sideband components, and their root-mean-square (RMS) values are measured. The ratio of the RMS values in two adjacent phases are calculated. Both the individual ratio and the variance of 3 ratios are studied and testified to show the feasibility of detecting fault. Simulations have shown that both of them are valid fault indicator in ideal conditions while the variance is better in conditions with phase imbalance.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
PWM ripple currents based turn fault detection for 3-phase permanent magnet machines
Most permanent magnet (PM) machines are driven by inverter with pulse-width-modulation (PWM) voltages. The resultant phase current contains high frequency (HF) components, based on which, a new technique to detect turn fault is proposed. The machine model at high frequency is established and the HF current components are analyzed. A bandpass filter is used to extract the selected sideband components, and their root-mean-square (RMS) values are measured. The ratio of the RMS values in two adjacent phases are calculated. Both the individual ratio and the variance of 3 ratios are studied and testified to show the feasibility of detecting fault. Simulations have shown that both of them are valid fault indicator in ideal conditions while the variance is better in conditions with phase imbalance.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Turn fault detection for surface-mounted permanent magnet synchronous machine based on current residual
The mathematical models of the surface-mounted permanent magnet synchronous machine (SPMSM) in both healthy and turn fault conditions are utilized to generate the current residual with the same voltage input. The features in the current residual are analyzed with the consideration of model accuracy. The 2nd harmonic in the positive rotating dq reference or the dc component in the negative rotating dq reference can be extracted as the fault indicator. To estimate the dc component in the negative rotating reference that is more accurate and robust to transient states, a periodical integral is used in favor of conventional filtering or fast Fourier transform (FFT). It can be shown that the proposed fault detection scheme can distinguish the effect of speed or torque transient from the fault, thus giving a more reliable detecting result. The proposed technique is verified by simulation on a 12-slot, 14-pole SPMSM under various operating conditions.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Turn fault detection for surface-mounted permanent magnet synchronous machine based on current residual
The mathematical models of the surface-mounted permanent magnet synchronous machine (SPMSM) in both healthy and turn fault conditions are utilized to generate the current residual with the same voltage input. The features in the current residual are analyzed with the consideration of model accuracy. The 2nd harmonic in the positive rotating dq reference or the dc component in the negative rotating dq reference can be extracted as the fault indicator. To estimate the dc component in the negative rotating reference that is more accurate and robust to transient states, a periodical integral is used in favor of conventional filtering or fast Fourier transform (FFT). It can be shown that the proposed fault detection scheme can distinguish the effect of speed or torque transient from the fault, thus giving a more reliable detecting result. The proposed technique is verified by simulation on a 12-slot, 14-pole SPMSM under various operating conditions.