AOAleksandr Aleksandrovich Oleynikov

Aleksandr Aleksandrovich Oleynikov

*This is an algorithmically generated author record based on publicly available information.

Aleksandr Aleksandrovich Oleynikov has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative assessment of cephalometric parameters on lateral cephalograms in the retruded contact position and in the intercuspal position with centric relation (ICP-CR) in prosthodontic patients: a cross-sectional diagnostic study

    by Sergey I. Kalinovskiy, Калиновский Сергей Игоревич, Olesya Mikolaevskaya, Миколаевская Олеся Геннадьевна, Andrei V. Sevbitov, Севбитов Андрей Владимирович, Alexander Oleynikov, Олейников Александр Александрович, Nikolay Domashkevich, Домашкевич Николай Сергеевич, et al.

    BACKGROUND: The accuracy of cephalometric diagnostics in prosthodontic dentistry is directly determined by the reproducibility of the mandibular position during lateral cephalogram acquisition. In clinical practice, two reference positions are employed — the intercuspal position combined with centric relation (ICP-CR) and the retruded contact position (RCP), which is fixed using occlusal registration templates. However, a comparative assessment of the comparability of cephalometric parameters obtained in these positions remains insufficiently investigated, which underpins the relevance of the present study. AIM: To conduct a comparative evaluation of skeletal, dental, and soft-tissue cephalometric parameters derived from lateral cephalograms obtained in the RCP and in the ICP-CR position, as well as to determine clinically significant differences between these positions, accounting for patient sex, age, and occlusion type. METHODS: The study included cephalometric measurement data from lateral cephalograms of 50 patients, acquired in two positions: RCP and ICP-CR. Sagittal (ANB, WITS), vertical (SN/MP, FH/MP), dental (U1/APg, L1/APg), and soft-tissue (SnN'Pg', Jarabak ratio) parameters were analyzed. For each parameter, mean values, standard deviations, mean differences (Δ = ICP-CR − RCP), and mean absolute differences |Δ| were calculated. Paired t tests were performed, effect sizes were computed using Cohen's d, Pearson correlation coefficients were calculated, and subgroup analyses were conducted by sex, age, and occlusion type. RESULTS: The most stable parameter was SN/MP (mean Δ = +0.6°; SD Δ ≈ 2.1°; d 0.2). A statistically significant systematic difference was identified for the SnN'Pg' parameter (Δ = −1.4°; SD Δ ≈ 3.2°; t ≈ 2.59; p ≈ 0.014; d ≈ 0.44). For WITS, a trend toward significance was observed (Δ ≈ +0.5 mm; p ≈ 0.06–0.09). The greatest individual variability was recorded for FH/MP (individual Δ up to ± 7°) and L1/APg (SD Δ ≈ 3.8 mm). In the subgroup of patients with Class II occlusion, the most pronounced differences were observed for ANB (+0.9°), WITS (+1.5 mm), and SnN'Pg' (−2.1°; p 0.05). In patients under 18 years of age, |Δ| for WITS and L1/APg was greater than in adults (p ≈ 0.04–0.07). CONCLUSION: The RCP and ICP-CR demonstrate acceptable group-level reproducibility for the majority of skeletal cephalometric parameters. However, systematic differences in the softtissue profile (SnN'Pg') and substantial individual variability in FH/MP and dental parameters indicate the clinical significance of the choice of registration position, particularly in patients with Class II occlusion and hyperdivergent growth pattern. ICP-CR is recommended as the primary position for diagnostic evaluation, with repeat registrations indicated when discrepancies exceed 2–3°. A limitation of the present study is that the statistical analysis was performed using aggregated data, which constrains the application of more detailed analytical methods.

  • Open Access

    Use of standardized test questionnaires in the diagnosis of adherence in dental patients

    by A. V. Guskov, V. V. Yakovlev, N. V. Yakovleva, A. S. Utyuzh, A. S. Kokunova, A. A. Oleinikov, N. D. Guskova, N. V. Skibinskaya, S. I. Kalinovskii, T. A. Vasileva, et al.

    Relevance: In Russian dental practice, there is a shortage of psychometrically validated instruments for assessing treatment adherence, developed specifically for the dental setting. Aim: To develop and test the full (96 items) and short (24 items) versions of questionnaires for assessing adherence to treatment in dental patients. Materials and Methods: The theoretical basis was the concept of vital metacompetence [2]. Psychometric testing included content, criterion, and external validity, involving expert assessments by dentists (n=59), and internal consistency (Cronbach’s α). Results: The full version (QDA-96) consists of 12 scales reflecting awareness, trust, and behavioral patterns. The short version (QDA-24) includes three aggregated scales (“Awareness”, “Trust”, “Behavior”) with a total score range of 24–96. A significant correlation (r=0.44; p≤0.01) was found between the total adherence score on the QDA-24 and independent physician assessment. Conclusion: The developed questionnaires are valid and allow differentiated assessment of the level and structure of adherence, which meets the modern requirements of a patientcentered approach [1].

  • Open Access

    Correlation of radiographic changes in bone tissue in the area of dental implants with inflammatory and microbiological factors of resorption against the background of cardiovascular diseases

    by Aleksandr Victorovich Gus'KOv, Anatoliy Utyuzh, Aleksandr Aleksandrovich Oleynikov, Aleksandr Alekseyevich Nikiforov, Dmitryi Sergeyevich Titov, Vadim Anatol'EVich Kunin, Tatyana Anatolyevna Vasil'EVa, Утюж Анатолий Сергеевич

    The development of peri-implantitis and bone resorption is associated with a complex of factors, including microbial biofilm and systemic inflammation. Patients with cardiovascular disease (CVD) are at particular risk, as they have preexisting endothelial dysfunction, which increases the susceptibility of the vascular wall to the virulence factors of periodontal pathogens and proinflammatory cytokines. A total of 104 patients aged 27 to 72 years with integrated dental implants supported by orthopedic structures were studied for 5 years. The patients were divided into two groups based on the severity of bone resorption around the dental implants. Patients underwent questionnaires, CBCT, microbiological testing, and assessment of IL-6, TNF-, and EN-1 levels. The concentration of the cytokine IL-6 was established corresponding to the degree of bone resorption in the implant area: the greatest increase in the indicator was observed in Group 2. The level of TNF- in Group 1 did not exceed the reference value. When assessing the correlation of EN-1 with P. gingivalis, T. denticola, P. intermedia, a moderate relationship was found only with P. gingivalis among the entire sample. When assessing the correlation of IL-6 with periodontopathogenic microorganisms, a moderate relationship was found only with P. intermedia, TNF- showed a weak correlation in all cases. The level of IL-6 and TNF- showed a noticeable correlation with the degree of bone resorption in the entire sample. A relationship was established between the clinical and radiographic degree of bone resorption in the implant area, the concentration of cytokines IL-6, TNF- and the occurrence of P. intermedia and T. denticola. Analysis of the cytokine profile may have prognostic value in planning implantation due to the sensitivity of IL-6 and TNF- to the persistence of P. intermedia and P. gingivalis, which in turn affects the state of the vascular endothelium, and through cytokine proinflammatory activity on the resistance of jaw bone tissue in patients with a history of cardiovascular diseases.

  • Open Access

    A Comparative Bioinformatics Analysis of the Transcriptomic Profiles of Peri-Implantitis and Periodontitis and Their Common Signaling Pathways with Atherosclerosis

    by Aleksandr V. Guskov, Anatoliy S. Utyuzh, Aleksandr A. Oleynikov, Aleksandr A. Nikiforov, Stanislav N. Kotlyarov

    (1) Objective. To conduct a comparative bioinformatics analysis of the transcriptomic profiles of peri-implantitis and periodontitis to identify common and specific molecular signatures underlying their pathogenesis, as well as molecular parallels with atherosclerosis. (2) Methods: We used datasets from the Gene Expression Omnibus (GEO) database: dataset GSE223924 (30 gingival tissue samples from patients with peri-implantitis, periodontitis, and healthy subjects) and GSE100927 (atherosclerotic and control tissue; n = 104). Differentially expressed genes (DEGs) were identified based on the criteria: |logFC| > 1 and FDR < 0.05. To quantitatively assess the relative abundance of immune cells, we used the xCell deconvolution algorithm. (3) Results: In the peri-implantitis group, 3669 DEGs with upregulated expression and 3106 with downregulated expression were identified; in the periodontitis group, 1968 and 1250 DEGs, respectively. Functional analysis of the upregulated DEGs revealed activation of inflammatory processes, cell adhesion, and angiogenesis in both diseases. Key differences lay in the activation of adaptive immune mechanisms in peri-implantitis (enrichment of the “graft rejection” and “T-cell receptor signaling”) and innate immunity in periodontitis (enrichment of the “lipopolysaccharide response” and “Toll-like receptors (TLR) signaling” pathways). Analysis of downregulated DEGs revealed more profound disruptions in cytoskeletal organization and epithelial differentiation in periodontitis, as well as suppression of xenobiotic and lipid metabolism in both diseases. xCell deconvolution confirmed a significant increase in B cells, neutrophils, monocytes, M1 macrophages, and dendritic cells in peri-implantitis, and also revealed a trend toward an increase in these cells in periodontitis (p > 0.05), which is consistent with the activation of TLR signaling. In periodontitis, a significant increase in M2 macrophages and a decrease in Th1 cells were observed. Comparison with atherosclerosis revealed 272 common DEGs with peri-implantitis and 173 common DEGs with periodontitis. Functional analysis of the common genes confirmed their role in leukocyte transendothelial migration, cytokine production, and the “Lipids and Atherosclerosis” pathway. (4) Conclusions: Functional analysis and immune deconvolution consistently demonstrate that peri-implantitis is characterized by statistically significant activation of both adaptive and innate immunity, whereas in periodontitis, the activation of innate immunity manifests primarily at the level of signaling pathways. The significant overlap found between the transcriptional profiles of both diseases and atherosclerosis may indicate the presence of common pathogenetic links.


  • Comparative evaluation of the accuracy of dental stone casts fabricated using different technologies and impression materials: an uncontrolled clinical and laboratory study

    by Sergey I. Kalinovskiy, Andrei V. Sevbitov, Andrey E. Shmoilov, Aleksandr A. Oleynikov, Efim R. Resh, Anna R. Ogareva, Калиновский Сергей Игоревич, Шмойлов Андрей Евгеньевич

    BACKGROUND: Despite the availability of studies addressing the accuracy of various impression materials and digital methods for jaw model acquisition, the comparative effectiveness of these approaches remains insufficiently investigated, underscoring the relevance of the present study. AIM: The work aimed to comparatively assess the accuracy of dental stone jaw casts obtained by conventional methods using different impression materials and of digital models produced by intraoral scanning. METHODS: The study included 30 patients with intact dentitions. For each patient, impressions were obtained using alginate, A-silicone, and C-silicone materials, and intraoral scanning was performed. Dental stone casts were fabricated from the analog impressions: solid casts from alginate impressions and casts with removable dies from silicone impressions using the Giroform system (Amann Girrbach AG, Austria) and a conventional technique. All physical models and digital scans were converted to 3D STL format. Comparative analysis of the accuracy of anatomic detail reproduction (teeth 1.6 and 2.1; ISO/FDI designation) was performed using Geomagic Control X (3D Systems, USA) by superimposition and deviation assessment. RESULTS: The highest accuracy (minimal deviation from the digital reference) was observed for solid casts fabricated from alginate impressions: deviation of 0.0031 ± 0.0005 mm for tooth 1.6 and 0.0029 ± 0.0004 mm for tooth 2.1. Among casts with removable dies, those fabricated using the Giroform system demonstrated the best results: deviation of 0.0037 ± 0.0003 mm for tooth 1.6 and 0.0036 ± 0.0003 mm for tooth 2.1. The lowest accuracy was recorded for casts with removable dies fabricated by the conventional method from C-silicone impressions, with maximum deviations of 0.0066 ± 0.0007 mm and 0.0065 ± 0.0007 mm, respectively. All intergroup differences were significant (p 0.001). CONCLUSION: Digital models obtained by intraoral scanning and solid casts fabricated from alginate impressions demonstrate high and comparable accuracy. For fabrication of casts with removable dies, use of the Giroform system substantially improves accuracy compared with the conventional technique. These findings are clinically relevant for selecting the optimal method for producing working models in prosthodontics.

  • Open Access

    Experimental and clinical substantiation of adaptation of patents with multiple adentia to orthopedic dental structures through correction of volume and velocity of airflows in mouth cavity

    by Sergey I. Kalinovskiy, Andrey V. Sevbitov, Aleksandr A. Oleynikov, Калиновский Сергей Игоревич

    INTRODUCTION: Modern dental equipment and diversity of materials and technologies ensure manufacture of highly precise and aesthetic orthopedic structures. However, these structures do not take into account the position of natural teeth and the anatomical peculiarities of the hard palate, which impairs pronunciation, fixation and stabilization of dentures in the mouth cavity, and stimulates non-physiological ‘expulsion’ of the fluid-air-food emulsion during eating, speaking and breathing. The aspect of Modernization of removable denture manufacture is critical both in terms of gaining fundamental knowledge and optimizing the quality of dental care in practical healthcare. AIM: To conduct a comparative evaluation of architecture of the hard palate, the speed of phonetic adaptation, and also the velocity and direction of airflows in patents with partial and complete absence of teeth. METHODS: The study included 220 people, of them 130 were with intact dentitions (aged 20–25 years) and 90 patients with partial loss of teeth (aged 40–60). RESULTS: It has been demonstrated that the velocity and direction of the airflows in the mouth, and also the morphometric parameters of the palatal vault should be taken into account in modeling the palatal surface of removable dentures. Analysis, recording, and accounting for these parameters accelerate patient adaptation to the manufactured structures, which effects the quality of orthopedic rehabilitation. CONCLUSION: Replacement of defects in the dental arches in patients using the developed rehabilitation concept leads to faster speech adaptation to removable dentures, without increasing the time required to manufacture orthopedic structures.

  • Assessment of the Association Between Peri-implant Bone Tissue Status and Systemic and Local Inflammatory Factors

    by Alexander V. Guskov, Alexander А. Nikiforov, Alexander А. Oleynikov, Vitaly O. Strebkov, Karina V. Sidorova, Pavel M. Ignatov, Олейников Александр Александрович

    BACKGROUND: Detection of proinflammatory cytokines during dental treatment planning may serve as a prognostic indicator for the potential inflammatory response to integrated implants, particularly in the form of uncontrolled local bone resorption. AIM: The work aimed to evaluate the relationship between the concentration of proinflammatory cytokines—interleukin-6 (IL-6), tumor necrosis factor α (TNF-α), and C-reactive protein (CRP) — and the condition of jawbone tissue in the area of installed dental implants, taking into account inflammatory processes in the peri-implant region. METHODS: A total of 75 patients aged 27 to 72 years were examined. Based on cone-beam computed tomography findings, participants were divided into three groups according to the extent of vertical bone resorption around dental implants: group 1 (n = 29), resorption 1/3 of implant length; group 2 (n = 32), resorption up to 1/2 of implant length; and group 3 (n = 14), resorption 2/3 of implant length. The serum concentrations of IL-6, TNF-α, and CRP were evaluated, the implant hygiene index was analyzed, and a macrohistochemical assessment of inflammation in the transgingival portion of the abutments was performed. RESULTS: Jawbone resorption and proinflammatory cytokine concentrations in group 1 were as follows: resorption 0.6 ± 0.1 mm, IL-6 concentration 0.34 ± 0.31 pg/mL, TNF-α concentration 0.5 ± 0.1 pg/mL, CRP concentration 2.6 ± 6.0 pg/mL; in group 2, resorption was 2.4 ± 0.8 mm, IL-6 concentration 1.3 ± 0.5 pg/mL, TNF-α concentration 1.7 ± 0.5 pg/mL, CRP concentration 3.45 ± 3.40 pg/mL; in group 3, resorption was 4.6 ± 1.6 mm, IL-6 concentration 2.3 ± 0.4 pg/mL, TNF-α concentration 2.3 ± 0.2 pg/mL, CRP concentration 3.0 ± 2.2 pg/mL. Comparative analysis of cone-beam computed tomography data and concentrations of IL-6 and TNF-α revealed significant intergroup differences (p 0.001). Correlation analysis of IL-6 and TNF-α concentrations demonstrated a notable association with bone resorption across the entire sample (p 0.001). Assessment of the relationship between hygiene levels in the transgingival portion of the abutment and the degree of inflammation established a moderate correlation across the entire sample (p 0.001). The relationship between IL-6 and TNF-α cytokine concentrations and the severity of inflammation was also statistically significant. CONCLUSION: The degree of bone resorption in the implant area has a direct correlational relationship with the concentrations of proinflammatory cytokines IL-6 and TNF-α. These findings may indicate the importance of assessing the concentrations of these proinflammatory cytokines to identify a risk group among patients with implants under load for five or more years, considering localized inflammation in the transgingival portion of abutments. Additionally, cytokine status can be monitored during implant planning, potentially serving as a predictive factor for forecasting the long-term stability of implants.

  • Assessment of Quality of Life of Patients with Removable Partial Laminar Dentures of Different Designs

    by Aleksandr V. Gus’kOv, Nikolay M. Shuvalov, Sergey D. Malikov, Aleksandr A. Oleynikov

    INTRODUCTION: Despite the rapid development of orthopedic dentistry, dentoprosthetic rehabilitation with removable laminar dentures does not lose its relevance. However, today rehabilitation with this method is still associated with a number of problems — progressive atrophy of bone tissue, complex adaptation process, poor adhesion of the denture to the denture bed. In this context, an issue of the quality of life of patients using removable laminar dentures remains relevant. AIM: To conduct a comparative assessment of the quality of life and of tenderness of the denture bed during adaptation in patients rehabilitated with partial removable laminar dentures of different design. MATERIALS AND METHODS: A survey of 90 people was conducted, divided into 3 equal groups. Patients of group A were rehabilitated with removable overdentures of the original design, patients of group B with partial removable dentures made of thermoplastic material, patients of group C with classic acrylic partial removable dentures. At 1, 14 and 30 days after the application of new dentures, pain sensations were assessed in patients on Numeric Rating Scale (NRS). Besides, as a part of study, the quality of life of patients was assessed using OHIP-14 questionnaire. RESULTS: The best quality of life parameters according to examinations at 1 and 6 months were recorded in group A. Thus, the mean score on OHIP-14 questionnaire was lower in group A than in groups B and C by 11.5 and 13.47 points respectively (p < 0.001). On assessment at 6 months, the respective parameters were lower in group A than in groups B and C, by 12.7 and 14.69 points respectively (p < 0.001). In analysis of pain sensations on NRS according to the data of all examinations, the least pain in the denture bed area was recorded in group A and the greatest - in group C. Besides, the greatest number of cases of regular wearing the manufactured dentures and the least number of corrections were also recorded in group A. CONCLUSION: Thus, the conclusion was made about the advantage of the proposed design over standard acrylic dentures and dentures made of thermoplastic material in terms of the quality of life and adaptation issues.

  • Comparative Assessment of Chewing Efficiency and Analysis of Electromyography Data with Various Methods of Prosthetics of Free-End Edentulous Space

    by Ryazan Medical State University, Aleksandr V. Gus’kOv, Nikolay M. Shuvalov, Sergey D. Malikov, Aleksandr A. Oleynikov, Natal’yA V. Doroshina

    INTRODUCTION: Despite the extensive development of dentistry, removable prosthetics methods still do not lose their relevance. Upon that, non-physiological transmission of chewing pressure by such dentures is a known fact. To optimize removable prosthetics methods, in particular, in terms of improving chewing effectiveness, the authors’ team proposed a non-fixed overdenture of an original design. AIM: To provide a comparative assessment of chewing efficiency and conduct an analysis of electromyography data when using partial removable dentures of various designs. MATERIALS AND METHODS: The authors conducted a prospective study involving 90 patients divided into 3 equal groups of 30 patients. Each group was subdivided into 2 equal subgroups of 15 patients by age from 18 to 60 years and from 60 to 80 years. Patients of A group underwent orthopedic rehabilitation with original dentures, of group B with classic removable laminar dentures, of group C with removable laminar dentures made of thermoplastic. As part of the study, immediately before orthopedic rehabilitation, after application of and complete adaptation to the denture, at 3 and 6 months after prosthetics, the patients underwent surface myography of masticatory and temporal muscles. Besides, as part of the same examinations, the patients were asked to perform a modified chewing test of I. S. Rubinov. RESULTS: The authors revealed a sharp increase in the parameters of surface electromyography in all the groups immediately after application of a removable denture and completion of the adaptation period. Subsequently, over time, a decrease in the surface electromyography parameters was noted in all the groups. However, in patients of group A, the electromyography parameters were decreasing much more slowly than in patients of other groups (p < 0.0001). Thus, at 6 months, the electromyography parameters of the masticatory muscle in patients of group A aged 18–60 years were 264 µV higher than in group B, and 111 µV higher than in group C. Similar parameters of group A patients aged 60–80 years were 214 and 160 µV higher than in groups B and C, respectively. At 6 months, the results of the temporal muscle electromyography in group A patients aged 18–60 years, were 177 µV higher than in group B, and 136 µV higher than in group C. Among patients aged 60–80 years, the results in group A were 189 and 92 µV higher than in groups B and C, respectively. When analyzing the results of the chewing test at 6 months after prosthetics, the best results in terms of time and percentage of chewed food were observed in patients from group A. CONCLUSION: The data obtained indicate a higher chewing effectiveness of the removable denture proposed by the authors as compared to the studied analogues.


  • Comparative analysis of the microbiological stability of modern polymers for the manufacture of removable prostheses

    by A.V. Gus’kOv, E.A. Kokoreva, S.A. Mashutin, A.A. Oleinikov, P.M. Ignatov

    Objective. The aim of the study is to study the degree of adhesion of reference strains of microorganisms to the surface of modern polymer materials for the manufacture of removable prostheses. Materials and methods. The primary and residual microbial adhesion of 4 types of polymers was studied: acrylic polymer (Villacryl H Plus), monomerless polymer (Vertex ThermoSens), photopolymers for additive manufacturing (Harz Labs Dental Denture Base, Harz Labs Dental Sand). C. albicans, S. aureus, E. faecalis, and S. mutans were used as reference strains. Results. The analysis of the primary adhesion of C. albicans, S. aureus, E. faecalis, and S. mutans revealed statistically significant differences between the adhesion indices to the studied material samples. The minimal indices of primary and residual adhesion were noted for the photopolymers for additive manufacturing samples while monomerless polymer samples showed the highest adhesion index in all cases. The indicators of residual adhesion of the reference strains were extremely low. Conclusion. Photopolymers for additive manufacturing have a lower index of primary and residual microbial adhesion in comparison with acrylic and non-monomeric polymers. These materials are potentially inert from a microbiological point of view and can be recommended for the manufacture of removable prostheses.