Byeonghyeon An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Byeonghyeon An has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Tae-Sik Park
Department of Electrical Engineering, Mokpo National University, Muan 58554, Republic of Korea
9 shared publications - Jeongsik Oh
Department of Electrical Engineering, Mokpo National University, Muan 58554, Republic of Korea
5 shared publications - Jae-Deok Park
Department of Electrical Engineering, Mokpo National University, Muan 58554, Republic of Korea
4 shared publications - Su-Han Pyo
Smart Grid Research Center, Korea Electrotechnology Research Institute, Gwangju 61751, Republic of Korea
4 shared publications - Tae-Hun Kim
Department of Electrical Engineering, Mokpo National University, Muan 58554, Republic of Korea
4 shared publications - Dong-Ho Lee
Department of Electrical Engineering, Mokpo National University, Muan 58554, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5263
Deep Reinforcement Learning-Based Integrated Maintenance Planning for Multiple Types of Power Assets
Asset management of power assets is a decision-making process that manages risk by considering asset condition and the consequences of failure while ensuring supply reliability and cost-effective maintenance within a limited budget. However, when maintenance plans are developed and budgets are allocated separately for each asset class, it is difficult to compare the investment effects across different types of assets and to establish an investment plan that reflects organization-wide asset management objectives. To address this limitation, the maintenance effects of heterogeneous assets must be evaluated on a common economic basis to prioritize investments, and the assets to be maintained and the timing of maintenance must be determined jointly within the available budget. This paper proposes a Deep Q-network-based integrated maintenance optimization method for heterogeneous assets, namely power transformers and gas-insulated switchgear, using risk and investment value assessments. The proposed method reflects condition changes caused by asset deterioration and maintenance, and it learns a maintenance policy that accounts for long-term investment effects under a shared budget constraint. In the simulation, the Benefit–Cost ratio is calculated from the present values of the benefits and costs estimated using synthetic data for power transformers and GIS, and it is incorporated into the Deep Q-Network algorithm as the investment value to derive a maintenance strategy. The proposed method is then compared with independent maintenance strategies for each asset class under the same total budget and evaluation period, and its applicability is verified in terms of maintenance cost, expected loss reduction benefit, and investment efficiency.
- 12 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5263
Open AccessDeep Reinforcement Learning-Based Integrated Maintenance Planning for Multiple Types of Power Assets
Asset management of power assets is a decision-making process that manages risk by considering asset condition and the consequences of failure while ensuring supply reliability and cost-effective maintenance within a limited budget. However, when maintenance plans are developed and budgets are allocated separately for each asset class, it is difficult to compare the investment effects across different types of assets and to establish an investment plan that reflects organization-wide asset management objectives. To address this limitation, the maintenance effects of heterogeneous assets must be evaluated on a common economic basis to prioritize investments, and the assets to be maintained and the timing of maintenance must be determined jointly within the available budget. This paper proposes a Deep Q-network-based integrated maintenance optimization method for heterogeneous assets, namely power transformers and gas-insulated switchgear, using risk and investment value assessments. The proposed method reflects condition changes caused by asset deterioration and maintenance, and it learns a maintenance policy that accounts for long-term investment effects under a shared budget constraint. In the simulation, the Benefit–Cost ratio is calculated from the present values of the benefits and costs estimated using synthetic data for power transformers and GIS, and it is incorporated into the Deep Q-Network algorithm as the investment value to derive a maintenance strategy. The proposed method is then compared with independent maintenance strategies for each asset class under the same total budget and evaluation period, and its applicability is verified in terms of maintenance cost, expected loss reduction benefit, and investment efficiency.
- Open Access
Study on HILS Implementation of FPGA-Based PFC Circuits Using Sub-Cycle Average Models
This paper presents a Field-Programmable Gate Array (FPGA)-based Hardware-in-the-Loop (HIL) simulation of an Interleaved Boost Power Factor Correction (PFC) converter using the Sub-Cycle Average (SCA) modeling technique. The main objective is to achieve accurate real-time simulation performance given the hardware constraints of low-cost FPGAs. By combining the SCA modeling approach with a time-averaging correction method, the proposed model effectively reduces sampling delays and duty-cycle estimation errors arising from asynchronous Pulse Width Modulation (PWM) signal acquisition. The SCA-based converter model and time-averaging correction technique were implemented in MATLAB/Simulink R2024b using the HDL Coder environment. To validate real-time simulation accuracy, power factor improvement was evaluated for a two-phase Interleaved Boost PFC operating at a switching frequency of 60 kHz. Experimental results confirm that the proposed approach enables accurate Controller–HIL testing of power converters, even when implemented on low-cost FPGA platforms such as the Zybo Z7-10 evaluation board.
Open AccessStudy on HILS Implementation of FPGA-Based PFC Circuits Using Sub-Cycle Average Models
This paper presents a Field-Programmable Gate Array (FPGA)-based Hardware-in-the-Loop (HIL) simulation of an Interleaved Boost Power Factor Correction (PFC) converter using the Sub-Cycle Average (SCA) modeling technique. The main objective is to achieve accurate real-time simulation performance given the hardware constraints of low-cost FPGAs. By combining the SCA modeling approach with a time-averaging correction method, the proposed model effectively reduces sampling delays and duty-cycle estimation errors arising from asynchronous Pulse Width Modulation (PWM) signal acquisition. The SCA-based converter model and time-averaging correction technique were implemented in MATLAB/Simulink R2024b using the HDL Coder environment. To validate real-time simulation accuracy, power factor improvement was evaluated for a two-phase Interleaved Boost PFC operating at a switching frequency of 60 kHz. Experimental results confirm that the proposed approach enables accurate Controller–HIL testing of power converters, even when implemented on low-cost FPGA platforms such as the Zybo Z7-10 evaluation board.
- Open Access
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 129659-129677
Economic Analysis of Critical Distance Based on Frequency in Low Frequency AC for Offshore Wind Farms
This paper presents a frequency-dependent cost analysis model for optimizing the economic performance of Low-Frequency AC (LFAC) transmission systems for offshore wind integration. Unlike previous studies that assumed fixed frequencies (e.g., 16.7 Hz or 20 Hz), the proposed model evaluates how variations in frequency affect the cost of key components, including transformers, offshore platforms, and submarine cables. By modeling the cost of the total system as a function of frequency, transmission capacity, and distance, the system’s optimal operating frequency is identified under various conditions. In addition, LFAC, High-Voltage AC (HVAC), and High-Voltage DC (HVDC) systems are compared based on the concept of economic critical distance, which defines the boundary between the most economically favorable transmission technologies depending on distance and capacity conditions. The results show that HVAC is the most cost-effective solution for short transmission distances, LFAC is optimal for medium-range transmission, and HVDC is favorable for long-distance applications. Notably, LFAC outperforms HVDC when cable multiplication is avoided, confirming its competitiveness in midrange scenarios. These findings demonstrate that considering frequency as a design parameter significantly improves the cost efficiency of LFAC systems and should be reflected in the early-stage planning of offshore transmission system design.
- 16 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 129659-129677
Open AccessEconomic Analysis of Critical Distance Based on Frequency in Low Frequency AC for Offshore Wind Farms
This paper presents a frequency-dependent cost analysis model for optimizing the economic performance of Low-Frequency AC (LFAC) transmission systems for offshore wind integration. Unlike previous studies that assumed fixed frequencies (e.g., 16.7 Hz or 20 Hz), the proposed model evaluates how variations in frequency affect the cost of key components, including transformers, offshore platforms, and submarine cables. By modeling the cost of the total system as a function of frequency, transmission capacity, and distance, the system’s optimal operating frequency is identified under various conditions. In addition, LFAC, High-Voltage AC (HVAC), and High-Voltage DC (HVDC) systems are compared based on the concept of economic critical distance, which defines the boundary between the most economically favorable transmission technologies depending on distance and capacity conditions. The results show that HVAC is the most cost-effective solution for short transmission distances, LFAC is optimal for medium-range transmission, and HVDC is favorable for long-distance applications. Notably, LFAC outperforms HVDC when cable multiplication is avoided, confirming its competitiveness in midrange scenarios. These findings demonstrate that considering frequency as a design parameter significantly improves the cost efficiency of LFAC systems and should be reflected in the early-stage planning of offshore transmission system design.
- Open Access
A Study on the Optimal Configuration of Offshore Substation Transformers
The growing scale of offshore wind farms and increasing transmission distances has driven the demand for optimized offshore substation (OSS) configurations. This study proposes a comprehensive techno-economic framework to minimize the total lifecycle cost (LCC) of an OSS by determining the optimal number of OSSs and transformers considering wind farm capacity and transmission distance. The methodology incorporates three cost models: capital expenditure (CAPEX), operational expenditure (OPEX), and expected energy not supplied (EENS). CAPEX considers transformer costs, topside structural mass effects, and nonlinear installation costs. OPEX accounts for substation maintenance and vessel operating expenses, and EENS is calculated using transformer failure probability models and redundancy configurations. The optimization is performed through scenario-based simulations and a net present value (NPV)-based comparative analysis to determine the cost-effective configurations. The quantitative analysis demonstrates that for small- to medium-scale wind farms (500–1000 MW), configurations using 1–2 substations and 3–4 transformers achieve minimal LCC regardless of the transmission distance. In contrast, large-scale wind farms (≥1500 MW) require additional substations to mitigate transmission losses and disruption risks, particularly over long distances. These results demonstrate that OSS design should holistically balance initial investment costs, operational reliability, and supply security, providing practical insights for cost-effective planning of next-generation offshore wind projects.
Open AccessA Study on the Optimal Configuration of Offshore Substation Transformers
The growing scale of offshore wind farms and increasing transmission distances has driven the demand for optimized offshore substation (OSS) configurations. This study proposes a comprehensive techno-economic framework to minimize the total lifecycle cost (LCC) of an OSS by determining the optimal number of OSSs and transformers considering wind farm capacity and transmission distance. The methodology incorporates three cost models: capital expenditure (CAPEX), operational expenditure (OPEX), and expected energy not supplied (EENS). CAPEX considers transformer costs, topside structural mass effects, and nonlinear installation costs. OPEX accounts for substation maintenance and vessel operating expenses, and EENS is calculated using transformer failure probability models and redundancy configurations. The optimization is performed through scenario-based simulations and a net present value (NPV)-based comparative analysis to determine the cost-effective configurations. The quantitative analysis demonstrates that for small- to medium-scale wind farms (500–1000 MW), configurations using 1–2 substations and 3–4 transformers achieve minimal LCC regardless of the transmission distance. In contrast, large-scale wind farms (≥1500 MW) require additional substations to mitigate transmission losses and disruption risks, particularly over long distances. These results demonstrate that OSS design should holistically balance initial investment costs, operational reliability, and supply security, providing practical insights for cost-effective planning of next-generation offshore wind projects.
- Open Access
Low-Frequency AC Multiport Asynchronous Grid Connection System to Optimize Generation Costs and Mitigate Bottlenecks
Renewable energy sources continue to increase due to the energy transition; thus, the generation output of conventional power sources is decreasing. The installation of renewable energy sources can lead to the concentration of these sources depending on geographical characteristics, which may cause bottlenecks between the renewable energy generation sites and load centers, and such bottlenecks can result in power shortages in load centers and may cause issues that limit the integration of renewable energy. Thus, this paper proposes the application of an LFAC multiport asynchronous grid connection system to solve these problems, where the frequency conversion device uses a variable frequency transformer (VFT). In addition, the installation location of the proposed LFAC multiport asynchronous grid connection system is selected using a grid partitioning technique, and the optimal power flow is performed to minimize the generation costs. The grid partitioning was conducted using the IEEE 39 bus system, and the feasibility of the proposed LFAC multiport asynchronous grid connection system was verified through simulation tests of the generation and load demands in the grid. In addition, the VFT control and optimal power flow control performances were confirmed through MATLAB/Simulink.
Open AccessLow-Frequency AC Multiport Asynchronous Grid Connection System to Optimize Generation Costs and Mitigate Bottlenecks
Renewable energy sources continue to increase due to the energy transition; thus, the generation output of conventional power sources is decreasing. The installation of renewable energy sources can lead to the concentration of these sources depending on geographical characteristics, which may cause bottlenecks between the renewable energy generation sites and load centers, and such bottlenecks can result in power shortages in load centers and may cause issues that limit the integration of renewable energy. Thus, this paper proposes the application of an LFAC multiport asynchronous grid connection system to solve these problems, where the frequency conversion device uses a variable frequency transformer (VFT). In addition, the installation location of the proposed LFAC multiport asynchronous grid connection system is selected using a grid partitioning technique, and the optimal power flow is performed to minimize the generation costs. The grid partitioning was conducted using the IEEE 39 bus system, and the feasibility of the proposed LFAC multiport asynchronous grid connection system was verified through simulation tests of the generation and load demands in the grid. In addition, the VFT control and optimal power flow control performances were confirmed through MATLAB/Simulink.
- Open Access
- 13 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 191790-191807
Power Transformer Health Index Using Cost-Sensitive Learning to Consider the Impact of Misclassification
Power companies employ comprehensive evaluations to manage facilities, such as transformers, lines, and generators, assessing their status and calculating the probability of failure. Within this asset management framework, a key metric that indicates the condition of facilities is the health index. To develop an optimal investment strategy for facility maintenance and management, a method for accurately calculating the health index is essential. Recent studies have explored the application of machine learning to improve accuracy. However, these studies ignore the risk of misclassification, which can result in significant financial losses when predicting the health index of power transformers. Therefore, this study proposes a health index calculation algorithm that incorporates cost-sensitive learning to assess the impact of each misclassification scenario, construct a cost matrix, and minimize the cost through learning. Input parameters are selected on the basis of the power transformer’s structure, failure mode effect analysis, failure diagnosis techniques, and historical failure cases. During the learning process, the relationship between actual and predicted classes is analyzed, and the risk associated with each misclassification scenario is quantified to describe the cost matrix. The effectiveness of the proposed health index calculation algorithm is validated using in-service power transformer inspection data, demonstrating a reduction in the risk of specific misclassification scenarios.
- 13 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 191790-191807
Open AccessPower Transformer Health Index Using Cost-Sensitive Learning to Consider the Impact of Misclassification
Power companies employ comprehensive evaluations to manage facilities, such as transformers, lines, and generators, assessing their status and calculating the probability of failure. Within this asset management framework, a key metric that indicates the condition of facilities is the health index. To develop an optimal investment strategy for facility maintenance and management, a method for accurately calculating the health index is essential. Recent studies have explored the application of machine learning to improve accuracy. However, these studies ignore the risk of misclassification, which can result in significant financial losses when predicting the health index of power transformers. Therefore, this study proposes a health index calculation algorithm that incorporates cost-sensitive learning to assess the impact of each misclassification scenario, construct a cost matrix, and minimize the cost through learning. Input parameters are selected on the basis of the power transformer’s structure, failure mode effect analysis, failure diagnosis techniques, and historical failure cases. During the learning process, the relationship between actual and predicted classes is analyzed, and the risk associated with each misclassification scenario is quantified to describe the cost matrix. The effectiveness of the proposed health index calculation algorithm is validated using in-service power transformer inspection data, demonstrating a reduction in the risk of specific misclassification scenarios.
- Open Access
Selection of an Optimal Frequency for Offshore Wind Farms
Offshore wind power has attracted significant attention due to its high potential, capability for large-scale farms, and high capacity factor. However, it faces high investment costs and issues with subsea power transmission. Conventional high-voltage AC (HVAC) methods are limited by charging current, while high-voltage DC (HVDC) methods suffer from the high cost of power conversion stations. The low-frequency AC (LFAC) method mitigates the charging current through low-frequency operation and can reduce power conversion station costs. This paper aims to identify the economically optimal frequency by comparing the investment costs of LFAC systems at various frequencies. The components of LFAC, including transformers, offshore platforms, and cables, exhibit frequency-dependent characteristics. Lower frequencies result in an increased size and volume of transformers, leading to higher investment costs for offshore platforms. In contrast, cable charging currents and losses are proportional to frequency, causing the total cost to reach a minimum at a specific frequency. To determine the optimal frequency, simulations of investment costs for varying capacities and distances were conducted.
Open AccessSelection of an Optimal Frequency for Offshore Wind Farms
Offshore wind power has attracted significant attention due to its high potential, capability for large-scale farms, and high capacity factor. However, it faces high investment costs and issues with subsea power transmission. Conventional high-voltage AC (HVAC) methods are limited by charging current, while high-voltage DC (HVDC) methods suffer from the high cost of power conversion stations. The low-frequency AC (LFAC) method mitigates the charging current through low-frequency operation and can reduce power conversion station costs. This paper aims to identify the economically optimal frequency by comparing the investment costs of LFAC systems at various frequencies. The components of LFAC, including transformers, offshore platforms, and cables, exhibit frequency-dependent characteristics. Lower frequencies result in an increased size and volume of transformers, leading to higher investment costs for offshore platforms. In contrast, cable charging currents and losses are proportional to frequency, causing the total cost to reach a minimum at a specific frequency. To determine the optimal frequency, simulations of investment costs for varying capacities and distances were conducted.
- Open Access
Prevention of Wildfires Using an AI-Based Open Conductor Fault Detection Method on Overhead Line
Overhead lines that are exposed to the outdoors are susceptible to faults such as open conductors on weak points and disconnection caused by external factors such as typhoons. Arcs that occur during disconnection generate energy at a high heat of over 10,000 °C, requiring swift fault shut-off. However, most conventional fault detection methods to protect electrical power systems detect an overcurrent; thus, they can only detect faults after the line is disconnected and the cross-section of the line that generates the arc discharge makes contact with another line or the ground, causing a high risk of fire. Furthermore, in the case of ground faults owing to the disconnection of overhead lines, the load and the grounding impedance are not parallel. Therefore, in the case of the fault current not exceeding the threshold or a high impedance fault due to the high grounding impedance of the surrounding environment, such as grass or trees, it is difficult to determine overhead line faults with conventional fault detection methods. To solve these issues, this paper proposes an AI-based open conductor fault detection method on overhead lines that can clear the fault before the falling open conductor line comes into contact with the ground’s surface so as to prevent fire. The falling time according to the height and span of the overhead line was calculated using a falling conductor model for the overhead line, to which the pendulum motion was applied. The optimal input data cycle that enables fault detection before a line–ground fault occurs was derived. For artificial intelligence learning to prevent wildfires, the voltage and current signals were collected through a total of 432 fault simulations and were wavelet-transformed with a deep neural network to verify the method. The proposed total scheme was simulated and verified with MATLAB.
Open AccessPrevention of Wildfires Using an AI-Based Open Conductor Fault Detection Method on Overhead Line
Overhead lines that are exposed to the outdoors are susceptible to faults such as open conductors on weak points and disconnection caused by external factors such as typhoons. Arcs that occur during disconnection generate energy at a high heat of over 10,000 °C, requiring swift fault shut-off. However, most conventional fault detection methods to protect electrical power systems detect an overcurrent; thus, they can only detect faults after the line is disconnected and the cross-section of the line that generates the arc discharge makes contact with another line or the ground, causing a high risk of fire. Furthermore, in the case of ground faults owing to the disconnection of overhead lines, the load and the grounding impedance are not parallel. Therefore, in the case of the fault current not exceeding the threshold or a high impedance fault due to the high grounding impedance of the surrounding environment, such as grass or trees, it is difficult to determine overhead line faults with conventional fault detection methods. To solve these issues, this paper proposes an AI-based open conductor fault detection method on overhead lines that can clear the fault before the falling open conductor line comes into contact with the ground’s surface so as to prevent fire. The falling time according to the height and span of the overhead line was calculated using a falling conductor model for the overhead line, to which the pendulum motion was applied. The optimal input data cycle that enables fault detection before a line–ground fault occurs was derived. For artificial intelligence learning to prevent wildfires, the voltage and current signals were collected through a total of 432 fault simulations and were wavelet-transformed with a deep neural network to verify the method. The proposed total scheme was simulated and verified with MATLAB.
- Open Access
Distributed Generation Based Virtual STATCOM Configuration and Control Method
Recently, because of the increase in the number of connections to Distributed Generation (DG), the problem of lowering voltage stability in the distribution system has become an issue. Reactive power compensators, such as Static Synchronous Compensators (STATCOM), may be used to solve the problem of voltage stability degradation. However, because of the complexity of the distribution system, it is very difficult to select the installation location for STATCOM. Furthermore, when installed in the wrong location, economical efficiency and availability problems may occur. This paper proposes a Virtual STATCOM Configuration and Control method that would operate like a single STATCOM based on multiple DGs connected to the system. The proposed Virtual STATCOM has the merit of being economical by using existing facilities without adding new power facilities, and it solves the problem of the difficulty of selecting the installation location because of the complexity of the distribution system. In addition, while the conventional STATCOM uses an independent control method in consideration of the power quality of the access point, the Virtual STATCOM performs the Point of Common Coupling (PCC) power quality compensation using the integrated control of multiple DGs connected to the system. In the proposed method, the Virtual STATCOM integrated control algorithm is configured by adopting linear programming, and the compensation is performed while considering the distance between DG and PCC, the inverter’s rated capacity, and the power generation. The performance of the Virtual STATCOM power quality compensation was verified using MATLAB/SIMULINK and Real Time Simulator (OPAL-RT).
Open AccessDistributed Generation Based Virtual STATCOM Configuration and Control Method
Recently, because of the increase in the number of connections to Distributed Generation (DG), the problem of lowering voltage stability in the distribution system has become an issue. Reactive power compensators, such as Static Synchronous Compensators (STATCOM), may be used to solve the problem of voltage stability degradation. However, because of the complexity of the distribution system, it is very difficult to select the installation location for STATCOM. Furthermore, when installed in the wrong location, economical efficiency and availability problems may occur. This paper proposes a Virtual STATCOM Configuration and Control method that would operate like a single STATCOM based on multiple DGs connected to the system. The proposed Virtual STATCOM has the merit of being economical by using existing facilities without adding new power facilities, and it solves the problem of the difficulty of selecting the installation location because of the complexity of the distribution system. In addition, while the conventional STATCOM uses an independent control method in consideration of the power quality of the access point, the Virtual STATCOM performs the Point of Common Coupling (PCC) power quality compensation using the integrated control of multiple DGs connected to the system. In the proposed method, the Virtual STATCOM integrated control algorithm is configured by adopting linear programming, and the compensation is performed while considering the distance between DG and PCC, the inverter’s rated capacity, and the power generation. The performance of the Virtual STATCOM power quality compensation was verified using MATLAB/SIMULINK and Real Time Simulator (OPAL-RT).