Nadeev Wijesuriya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nadeev Wijesuriya has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Christopher A. Rinaldi
King's College London London UK
14 shared publicationsFelicity De Vere
King's College London London UK
12 shared publicationsVishal Mehta
King's College London London UK
10 shared publicationsPaolo Bosco
Guy's and St Thomas's NHS Foundation Trust London UK
9 shared publicationsSandra Howell
King's College London London UK
9 shared publicationsSteven A. Niederer
King’s College, London, UK
9 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (8)
Redefining response to cardiac resynchronization therapy: a post hoc analysis of the MORE-CRT MPP trial
Aims: Cardiac resynchronization therapy (CRT) response is commonly assessed at 6 months using left ventricular end-systolic volume (LVESV) and clinical endpoints. However, response may continue to evolve beyond this time point, with some initial non-responders subsequently improving or stabilizing. This study aimed to characterize changes in echocardiographic response from 6 to 12 months, identify predictors of these trajectories, and assess their relationship with longer-term clinical outcomes. Methods and results: This post hoc analysis of the MORE-CRT MPP trial included patients receiving conventional biventricular pacing only. Patients were classified as non-responders (15% reduction at 6 months), or delayed responders (15% at 12 months). Six-month non-responders were further classified as stabilized (LVESV reduction at 12 months) or deteriorated (LVESV increase at 12 months). Heart failure hospitalization or death was analysed using restricted mean survival time and adjusted accelerated failure time models. Among 2732 patients (69.4% male; 62.8% non-ischaemic), event-free survival differed between early, delayed, and non-responders (P < 0.001). Non-responders had 52% shorter event-free survival than early responders (P < 0.001), and 38% shorter than delayed responders (P = 0.025). Early and delayed responders had similar outcomes (P = 0.221). Among non-responders, 39.0% stabilized and 61.0% deteriorated; outcomes diverged after 6 months (P < 0.001). The deterioration group had 59% shorter event-free survival (P < 0.001). Ischaemic aetiology, non-LBBB, and lower baseline LVEF predicted delayed response. Conclusion: Delayed responders demonstrated similarly favourable clinical outcomes to early responders over the duration of follow-up. These findings support 12-month assessment and trajectory-based definitions of CRT response.
- 4 August 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (8)
Open AccessRedefining response to cardiac resynchronization therapy: a post hoc analysis of the MORE-CRT MPP trial
Aims: Cardiac resynchronization therapy (CRT) response is commonly assessed at 6 months using left ventricular end-systolic volume (LVESV) and clinical endpoints. However, response may continue to evolve beyond this time point, with some initial non-responders subsequently improving or stabilizing. This study aimed to characterize changes in echocardiographic response from 6 to 12 months, identify predictors of these trajectories, and assess their relationship with longer-term clinical outcomes. Methods and results: This post hoc analysis of the MORE-CRT MPP trial included patients receiving conventional biventricular pacing only. Patients were classified as non-responders (15% reduction at 6 months), or delayed responders (15% at 12 months). Six-month non-responders were further classified as stabilized (LVESV reduction at 12 months) or deteriorated (LVESV increase at 12 months). Heart failure hospitalization or death was analysed using restricted mean survival time and adjusted accelerated failure time models. Among 2732 patients (69.4% male; 62.8% non-ischaemic), event-free survival differed between early, delayed, and non-responders (P < 0.001). Non-responders had 52% shorter event-free survival than early responders (P < 0.001), and 38% shorter than delayed responders (P = 0.025). Early and delayed responders had similar outcomes (P = 0.221). Among non-responders, 39.0% stabilized and 61.0% deteriorated; outcomes diverged after 6 months (P < 0.001). The deterioration group had 59% shorter event-free survival (P < 0.001). Ischaemic aetiology, non-LBBB, and lower baseline LVEF predicted delayed response. Conclusion: Delayed responders demonstrated similarly favourable clinical outcomes to early responders over the duration of follow-up. These findings support 12-month assessment and trajectory-based definitions of CRT response.
- Open Access
- 22 December 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (3) , 247-256
Safety Outcomes of Hybrid Open Chest Transvenous Lead Extraction: A Multicenter Experience
Background: Hybrid open chest transvenous lead extraction (TLE), combining surgical and endovascular techniques, may be utilized in patients requiring concomitant cardiac surgery or with high‐risk features for endovascular extraction. Outcome data in this population remains sparse. Aims: To evaluate procedural outcomes and identify predictors of complications in patients undergoing elective hybrid open chest TLE. Methods: A retrospective multicenter cohort study was conducted, including 40 patients between 2017 and 2025 across three UK tertiary centers. Patients undergoing emergency surgical conversion were excluded. Baseline, procedural, and outcome data were collected. Primary outcomes were in‐hospital mortality and complications, graded using a modified Delphi classification. Logistic regression was used to identify predictors of any or severe (Delphi grade ≥3) complications. Results: The mean age was 61.9 ± 17 years; 62.5% were male. Median lead dwell time was 10.5 years. The indication was infection in 65% of cases. Concomitant valve intervention was performed in 77.5% of cases. Clinical procedural success was 97.5%. In‐hospital mortality was 2.5%, with a rate of severe complications of 15%, and an overall complication rate of 37.5%. Multivariable analysis identified chronic lung disease as an independent predictor of severe complications (OR 102.2, p = 0.03). Atrial fibrillation was an independent predictor of any complication (OR 5.83, p = 0.04), driven primarily by post‐procedure rhythm intervention. Lead dwell time and EROS classification were not associated with adverse outcomes. Conclusion: Hybrid open chest TLE demonstrates high procedural success and despite significant morbidity, has acceptable mortality rates. Chronic lung disease independently predicts complications and should guide patient selection and perioperative planning.
- 22 December 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 49 (3) , 247-256
Open AccessSafety Outcomes of Hybrid Open Chest Transvenous Lead Extraction: A Multicenter Experience
Background: Hybrid open chest transvenous lead extraction (TLE), combining surgical and endovascular techniques, may be utilized in patients requiring concomitant cardiac surgery or with high‐risk features for endovascular extraction. Outcome data in this population remains sparse. Aims: To evaluate procedural outcomes and identify predictors of complications in patients undergoing elective hybrid open chest TLE. Methods: A retrospective multicenter cohort study was conducted, including 40 patients between 2017 and 2025 across three UK tertiary centers. Patients undergoing emergency surgical conversion were excluded. Baseline, procedural, and outcome data were collected. Primary outcomes were in‐hospital mortality and complications, graded using a modified Delphi classification. Logistic regression was used to identify predictors of any or severe (Delphi grade ≥3) complications. Results: The mean age was 61.9 ± 17 years; 62.5% were male. Median lead dwell time was 10.5 years. The indication was infection in 65% of cases. Concomitant valve intervention was performed in 77.5% of cases. Clinical procedural success was 97.5%. In‐hospital mortality was 2.5%, with a rate of severe complications of 15%, and an overall complication rate of 37.5%. Multivariable analysis identified chronic lung disease as an independent predictor of severe complications (OR 102.2, p = 0.03). Atrial fibrillation was an independent predictor of any complication (OR 5.83, p = 0.04), driven primarily by post‐procedure rhythm intervention. Lead dwell time and EROS classification were not associated with adverse outcomes. Conclusion: Hybrid open chest TLE demonstrates high procedural success and despite significant morbidity, has acceptable mortality rates. Chronic lung disease independently predicts complications and should guide patient selection and perioperative planning.
- Open Access
- 14 October 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (7) , 1817-1828
Efficacy of leadless left ventricular endocardial stimulation for non-responders to cardiac resynchronization therapy
Background: Non-responders to conventional coronary sinus CRT represent a high-risk heart failure population with limited treatment options. Leadless LV endocardial pacing may provide benefit by delivering more physiological activation patterns, and enabling pacing from optimized LV cavity sites. We aimed to evaluate the efficacy of leadless endocardial pacing using the WiSE-CRT system in CRT non-responders. Methods: A pooled patient-level post-hoc analysis of the SELECT-LV study, the WiSE Post-Market Registry and the SOLVE-CRT trial was performed. Multivariable regression analysis identified predictors of response to WiSE-CRT, followed by ROC analysis and subgroup analysis by degree of QRS narrowing. Results: The total cohort comprised of 71 patients. Complete echocardiographic data was available in 66 patients, and complete ECG data available in 45 patients. The clinical response rate (improvement in at least one NYHA class) was 46%. The “combined echocardiographic response rate” (composite of reduction in LV end-systolic volume of ≥15% or improvement in LV ejection fraction of ≥5%) was 51%. The degree of QRS reduction with WiSE-CRT compared to standard CRT was an independent predictor of combined echocardiographic response. ROC analysis generated an AUC of 0.68, with a Youden index cut-off of 19ms reduction in QRS. Subgroup analysis revealed a combined echocardiographic response rate of 70.5% above the cut-off and 38.5% below p = 0.04). Conclusion: Leadless endocardial CRT is a viable treatment option for conventional CRT non-responders. The degree of QRS narrowing with LV endocardial stimulation is predictive of response. Optimizing QRS reduction when testing LV pacing sites may be beneficial in maximizing outcomes. Graphical
- 14 October 2025
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (7) , 1817-1828
Open AccessEfficacy of leadless left ventricular endocardial stimulation for non-responders to cardiac resynchronization therapy
Background: Non-responders to conventional coronary sinus CRT represent a high-risk heart failure population with limited treatment options. Leadless LV endocardial pacing may provide benefit by delivering more physiological activation patterns, and enabling pacing from optimized LV cavity sites. We aimed to evaluate the efficacy of leadless endocardial pacing using the WiSE-CRT system in CRT non-responders. Methods: A pooled patient-level post-hoc analysis of the SELECT-LV study, the WiSE Post-Market Registry and the SOLVE-CRT trial was performed. Multivariable regression analysis identified predictors of response to WiSE-CRT, followed by ROC analysis and subgroup analysis by degree of QRS narrowing. Results: The total cohort comprised of 71 patients. Complete echocardiographic data was available in 66 patients, and complete ECG data available in 45 patients. The clinical response rate (improvement in at least one NYHA class) was 46%. The “combined echocardiographic response rate” (composite of reduction in LV end-systolic volume of ≥15% or improvement in LV ejection fraction of ≥5%) was 51%. The degree of QRS reduction with WiSE-CRT compared to standard CRT was an independent predictor of combined echocardiographic response. ROC analysis generated an AUC of 0.68, with a Youden index cut-off of 19ms reduction in QRS. Subgroup analysis revealed a combined echocardiographic response rate of 70.5% above the cut-off and 38.5% below p = 0.04). Conclusion: Leadless endocardial CRT is a viable treatment option for conventional CRT non-responders. The degree of QRS narrowing with LV endocardial stimulation is predictive of response. Optimizing QRS reduction when testing LV pacing sites may be beneficial in maximizing outcomes. Graphical
- Open Access
- 31 July 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 48 (9) , 959-966
Joint Pacing and Vascular Intervention for the Management of Cardiac Device Associated Central Venous Obstruction
Background and Aims: Central venous obstruction (CVO) increases the complexity of pacing interventions, whether it be with device‐associated symptomatic superior vena cava syndrome (SVCS), or by impeding new implants. Endovascular treatment involves the joint expertise of both cardiac pacing and vascular specialists. We report the outcomes of such procedures at our institution.Methods: A single‐center retrospective observational study, examining outcomes of joint pacing‐vascular procedures for CVO. Cases were screened from an existing institutional database.Results: There were 19 total cases. Two were new device implants where the novel “inside‐out” procedure was utilized to establish access in SVCS, both with no complications. The remainder (n = 17) were transvenous lead extractions plus attempted recanalization of CVO using venoplasty with or without stenting. Transvenous devices were re‐implanted in eight patients. Complete procedure success rate was 84%. There were two cases of pericardial effusion requiring pericardiocentesis, resulting in procedure abandonment. There was no in‐hospital mortality and no cases of emergency sternotomy. Over mean follow‐up of 28 months, 2/6 patients receiving venoplasty (33%) and 2/8 patients receiving stenting (25%) required re‐intervention for symptomatic restenosis. Of the patients who were not re‐implanted with a transvenous device following initially successful endovascular intervention (6/14), none had recurrence over the follow‐up period.Conclusion: Pacing interventions in SVCS carry a significant risk profile, requiring management by experienced operators in high‐volume centers to maximize safety. Endovascular interventions have a significant recurrence rate, with up‐front stenting potentially being superior. Our data suggests that those without re‐implantation of transvenous leads may have better long term outcomes.
- 31 July 2025
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 48 (9) , 959-966
Open AccessJoint Pacing and Vascular Intervention for the Management of Cardiac Device Associated Central Venous Obstruction
Background and Aims: Central venous obstruction (CVO) increases the complexity of pacing interventions, whether it be with device‐associated symptomatic superior vena cava syndrome (SVCS), or by impeding new implants. Endovascular treatment involves the joint expertise of both cardiac pacing and vascular specialists. We report the outcomes of such procedures at our institution.Methods: A single‐center retrospective observational study, examining outcomes of joint pacing‐vascular procedures for CVO. Cases were screened from an existing institutional database.Results: There were 19 total cases. Two were new device implants where the novel “inside‐out” procedure was utilized to establish access in SVCS, both with no complications. The remainder (n = 17) were transvenous lead extractions plus attempted recanalization of CVO using venoplasty with or without stenting. Transvenous devices were re‐implanted in eight patients. Complete procedure success rate was 84%. There were two cases of pericardial effusion requiring pericardiocentesis, resulting in procedure abandonment. There was no in‐hospital mortality and no cases of emergency sternotomy. Over mean follow‐up of 28 months, 2/6 patients receiving venoplasty (33%) and 2/8 patients receiving stenting (25%) required re‐intervention for symptomatic restenosis. Of the patients who were not re‐implanted with a transvenous device following initially successful endovascular intervention (6/14), none had recurrence over the follow‐up period.Conclusion: Pacing interventions in SVCS carry a significant risk profile, requiring management by experienced operators in high‐volume centers to maximize safety. Endovascular interventions have a significant recurrence rate, with up‐front stenting potentially being superior. Our data suggests that those without re‐implantation of transvenous leads may have better long term outcomes.
- Open Access
- 26 May 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (11) , 2895-2905
Effect of leadless left ventricular endocardial and left bundle branch area pacing on biventricular repolarization metrics
- 26 May 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (11) , 2895-2905
Open AccessEffect of leadless left ventricular endocardial and left bundle branch area pacing on biventricular repolarization metrics
- Open Access
- 12 September 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 546-553
Potential applications of ultrasound-based leadless endocardial pacing in adult congenital heart disease
- 12 September 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 546-553
Open AccessPotential applications of ultrasound-based leadless endocardial pacing in adult congenital heart disease
- Open Access
- 28 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 357-364
Left ventricular electrical delay predicts volumetric response to leadless cardiac resynchronization therapy
- 28 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (2) , 357-364
Open AccessLeft ventricular electrical delay predicts volumetric response to leadless cardiac resynchronization therapy
- Open Access
- 13 August 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (10) , 2039-2052
Convergent ablation for persistent atrial fibrillation: A UK multicentre perspective
Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and remains a major cause of morbidity and mortality. Unfortunately, a significant proportion of patients have persistent AF, for which conventional catheter ablation is less effective. However, convergent ablation has emerged in recent years as a hybrid treatment targeting both the epicardium and endocardium in a multidisciplinary joint cardiothoracic and electrophysiology procedure, with promising efficacy outcomes in recent studies. This treatment is increasingly being performed in the United Kingdom. This review article discusses the rationale and evidence behind convergent ablation, along with factors that need to be considered when setting up a successful ablation service.
- 13 August 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (10) , 2039-2052
Open AccessConvergent ablation for persistent atrial fibrillation: A UK multicentre perspective
Atrial fibrillation (AF) is the most common sustained arrhythmia worldwide and remains a major cause of morbidity and mortality. Unfortunately, a significant proportion of patients have persistent AF, for which conventional catheter ablation is less effective. However, convergent ablation has emerged in recent years as a hybrid treatment targeting both the epicardium and endocardium in a multidisciplinary joint cardiothoracic and electrophysiology procedure, with promising efficacy outcomes in recent studies. This treatment is increasingly being performed in the United Kingdom. This review article discusses the rationale and evidence behind convergent ablation, along with factors that need to be considered when setting up a successful ablation service.
- Open Access
- 6 July 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 5 (8) , 551-560
Optimizing electrical efficacy of leadless cardiac resynchronization therapy and leadless left ventricular septal pacing: Insights on left and right ventricular activation from electrocardiographic imaging
- 6 July 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 5 (8) , 551-560
Open AccessOptimizing electrical efficacy of leadless cardiac resynchronization therapy and leadless left ventricular septal pacing: Insights on left and right ventricular activation from electrocardiographic imaging
- Open Access
- 18 June 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (12) , e035279
Heart Size Difference Drives Sex‐Specific Response to Cardiac Resynchronization Therapy: A Post Hoc Analysis of the MORE‐MPP CRT Trial
Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased relative dyssynchrony at a given QRS duration (QRSd). Our objective was to investigate the mechanisms of sex‐specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods and Results: This is a post hoc analysis of the MORE‐CRT MPP (More Response on Cardiac Resynchronization Therapy with Multipoint Pacing) trial (n=3739, 28% women), with a subgroup analysis of patients with nonischemic cardiomyopathy and left bundle‐branch block (n=1308, 41% women) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/left ventricular end‐diastolic volume (LVEDV). Women had a higher CRT response rate than men (70.1% versus 56.8%, P P P P =0.012). The association between CRT response and QRSd/LVEDV was strongest at QRSd <150 ms. Conclusions: In the nonischemic cardiomyopathy left bundle‐branch block population, increased relative dyssynchrony in women, who have smaller heart sizes than their male counterparts, is a driver of sex‐specific CRT response, particularly at QRSd <150 ms. Women may benefit from CRT at a QRSd <130 ms, opening the debate on whether sex‐specific QRSd cutoffs or QRS/LVEDV measurement should be incorporated into clinical guidelines.
- 18 June 2024
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 13 (12) , e035279
Open AccessHeart Size Difference Drives Sex‐Specific Response to Cardiac Resynchronization Therapy: A Post Hoc Analysis of the MORE‐MPP CRT Trial
Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased relative dyssynchrony at a given QRS duration (QRSd). Our objective was to investigate the mechanisms of sex‐specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods and Results: This is a post hoc analysis of the MORE‐CRT MPP (More Response on Cardiac Resynchronization Therapy with Multipoint Pacing) trial (n=3739, 28% women), with a subgroup analysis of patients with nonischemic cardiomyopathy and left bundle‐branch block (n=1308, 41% women) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/left ventricular end‐diastolic volume (LVEDV). Women had a higher CRT response rate than men (70.1% versus 56.8%, P P P P =0.012). The association between CRT response and QRSd/LVEDV was strongest at QRSd <150 ms. Conclusions: In the nonischemic cardiomyopathy left bundle‐branch block population, increased relative dyssynchrony in women, who have smaller heart sizes than their male counterparts, is a driver of sex‐specific CRT response, particularly at QRSd <150 ms. Women may benefit from CRT at a QRSd <130 ms, opening the debate on whether sex‐specific QRSd cutoffs or QRS/LVEDV measurement should be incorporated into clinical guidelines.