Nathan Keller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nathan Keller has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Vacca
Maha Fluid Power Research Center, Purdue University, Lafayette, IN, USA
3 shared publications - Annalisa Sciancalepore
Purdue University, 1500 Kepner Drive, Lafayette IN 47905, Indiana, United States
2 shared publications - Patrick M. Stump
School of Mechanical Engineering, Purdue University, 610 Purdue Mall, West Lafayette, IN 47907, USA
1 shared publication
Latest Publications
- Open Access
- 3 May 2023
- Published by River Publishers in International Journal of Fluid Power
- Vol. 24 (2) , 171–206
Condition Monitoring of an Axial Piston Pump on a Mini Excavator
The focus of this paper is to show the process of developing a condition monitoring system for an axial piston pump mounted on a mini excavator. This work outlines some previous condition monitoring work on axial piston pumps but addresses the lack of research conducted on mobile hydraulics. The valve plate of the pump is chosen as a case study to demonstrate varying degrees of wear and damage to represent healthy and faulty pump conditions. The wear and damage of these valve plates is measured using an optical profilometer, and efficiency measurements were conducted to characterize the fault levels. Once the faults were characterized, the mini excavator was introduced and instrumented to demonstrate what parameters were being considered. Next, three duty cycles were introduced: controlled, digging, and different operator cycles. The controlled cycles are a very repeatable condition that eliminated the need of an operator. The digging cycle was more of a realistic cycle where an operator dug into a loose pile of soil. The different operator cycle is the same as the digging cycle, but a different operator was employed. The sensors that proved to be the most useful in detecting valve plate faults were the drain pressure, pump port pressures, engine speed, and pump displacement. Fault detectability accuracies of 100% were achievable under the controlled cycle utilizing the Fine KNN classification machine learning algorithm. The digging cycle could achieve a fault detection accuracy of 93.6% using the same algorithm and sensors. Finally, the cross-compatibility between a model trained under once cycle and using data from another cycle as an input was investigated. This study showed that a model trained under the controlled duty cycle does not give reliable and accurate fault detectability for data run in a digging cycle, below 60% accuracies. However, cross-compatibility may be achievable if more extreme faults are present. This work concluded by recommending a diagnostic function for mobile machines to perform a preprogrammed operation to reliably and accurately detect pump faults.
- 3 May 2023
- Published by River Publishers in International Journal of Fluid Power
- Vol. 24 (2) , 171–206
Open AccessCondition Monitoring of an Axial Piston Pump on a Mini Excavator
The focus of this paper is to show the process of developing a condition monitoring system for an axial piston pump mounted on a mini excavator. This work outlines some previous condition monitoring work on axial piston pumps but addresses the lack of research conducted on mobile hydraulics. The valve plate of the pump is chosen as a case study to demonstrate varying degrees of wear and damage to represent healthy and faulty pump conditions. The wear and damage of these valve plates is measured using an optical profilometer, and efficiency measurements were conducted to characterize the fault levels. Once the faults were characterized, the mini excavator was introduced and instrumented to demonstrate what parameters were being considered. Next, three duty cycles were introduced: controlled, digging, and different operator cycles. The controlled cycles are a very repeatable condition that eliminated the need of an operator. The digging cycle was more of a realistic cycle where an operator dug into a loose pile of soil. The different operator cycle is the same as the digging cycle, but a different operator was employed. The sensors that proved to be the most useful in detecting valve plate faults were the drain pressure, pump port pressures, engine speed, and pump displacement. Fault detectability accuracies of 100% were achievable under the controlled cycle utilizing the Fine KNN classification machine learning algorithm. The digging cycle could achieve a fault detection accuracy of 93.6% using the same algorithm and sensors. Finally, the cross-compatibility between a model trained under once cycle and using data from another cycle as an input was investigated. This study showed that a model trained under the controlled duty cycle does not give reliable and accurate fault detectability for data run in a digging cycle, below 60% accuracies. However, cross-compatibility may be achievable if more extreme faults are present. This work concluded by recommending a diagnostic function for mobile machines to perform a preprogrammed operation to reliably and accurately detect pump faults.
- 22 February 2022
- Published by River Publishers in International Journal of Fluid Power
- Vol. 23 (2) , 205–236
Demonstrating a Condition Monitoring Process for Axial Piston Pumps with Damaged Valve Plates
Unexpected pump failures in mobile fluid power systems result in monetary and productivity losses, but these failures can be alleviated by implementing a condition monitoring system. This research aims to find the best condition monitoring (CM) technique for a pump with the fewest number of sensors, to accurately detect a defective condition. The sensors choice in a CM system is a critical decision, and a high number of sensors may result in disadvantages besides additional cost, such as overfitting the CM model and increased maintenance. A variable displacement axial piston pump is used as a reference machine for testing the CM technique. Several valve plates with various magnitudes of quantifiable wear and damage are used to compare “healthy” and “unhealthy” hydraulic pumps. The pump parameters are measured on a stationary test rig. This involves observing and detecting differences in pump performance between the healthy and unhealthy conditions and reducing the number of sensors required to monitor a pump’s condition. Observable differences in drain flow were shown, and machine learning algorithms were able to successfully classify a faulty and healthy pump with accuracies nearing 100%. The number of sensors was reduced by implementing a feature selection process and resulted in only five of the 23 sensors to correctly detect pump failure. These sensors measure outlet pressure, inlet pressure, drain pressure, pump speed, and pump displacement. The resulting reduction of sensors is reasonably affordable and relatively easy to implement on mobile applications.
- 22 February 2022
- Published by River Publishers in International Journal of Fluid Power
- Vol. 23 (2) , 205–236
Demonstrating a Condition Monitoring Process for Axial Piston Pumps with Damaged Valve Plates
Unexpected pump failures in mobile fluid power systems result in monetary and productivity losses, but these failures can be alleviated by implementing a condition monitoring system. This research aims to find the best condition monitoring (CM) technique for a pump with the fewest number of sensors, to accurately detect a defective condition. The sensors choice in a CM system is a critical decision, and a high number of sensors may result in disadvantages besides additional cost, such as overfitting the CM model and increased maintenance. A variable displacement axial piston pump is used as a reference machine for testing the CM technique. Several valve plates with various magnitudes of quantifiable wear and damage are used to compare “healthy” and “unhealthy” hydraulic pumps. The pump parameters are measured on a stationary test rig. This involves observing and detecting differences in pump performance between the healthy and unhealthy conditions and reducing the number of sensors required to monitor a pump’s condition. Observable differences in drain flow were shown, and machine learning algorithms were able to successfully classify a faulty and healthy pump with accuracies nearing 100%. The number of sensors was reduced by implementing a feature selection process and resulted in only five of the 23 sensors to correctly detect pump failure. These sensors measure outlet pressure, inlet pressure, drain pressure, pump speed, and pump displacement. The resulting reduction of sensors is reasonably affordable and relatively easy to implement on mobile applications.
- Open Access
Energy Management of Low-Pressure Systems Utilizing Pump-Unloading Valve and Accumulator
In the context of improving energy efficiency and fuel consumption of mobile hydraulic equipment, it is important to analyze all the sources of power loss occurring within the hydraulic systems. While plenty of analyses have been performed on the working implements and the main transmission systems, very little attention has been paid to low-pressure (LP) systems until recently. LP systems are required on closed-circuit hydraulic systems to replenish losses, provide cooling flow, and maintain a pilot pressure necessary to operate hydraulic control valves and variable displacement units. It is shown that these circuits, which are often thought to have minimal impact on power consumption, actually cause significant, continuous power loss. A new method of power savings in these circuits is investigated through management of charge pump flow by application of an accumulator-sense pump-unloading (ASPU) valve. This work further proposes the combination of a split LP architecture with an ASPU valve. Three systems are simulated using Simcenter Amesim® and MATLAB/Simulink®. Using realistic duty cycles and unit loss models on a circuit for mobile off-road hydraulic equipment, it is shown that a standard LP system can consume about 5 kW of power. Power savings of up to 65% over a standard LP system are demonstrated by the proposed architecture.
Open AccessEnergy Management of Low-Pressure Systems Utilizing Pump-Unloading Valve and Accumulator
In the context of improving energy efficiency and fuel consumption of mobile hydraulic equipment, it is important to analyze all the sources of power loss occurring within the hydraulic systems. While plenty of analyses have been performed on the working implements and the main transmission systems, very little attention has been paid to low-pressure (LP) systems until recently. LP systems are required on closed-circuit hydraulic systems to replenish losses, provide cooling flow, and maintain a pilot pressure necessary to operate hydraulic control valves and variable displacement units. It is shown that these circuits, which are often thought to have minimal impact on power consumption, actually cause significant, continuous power loss. A new method of power savings in these circuits is investigated through management of charge pump flow by application of an accumulator-sense pump-unloading (ASPU) valve. This work further proposes the combination of a split LP architecture with an ASPU valve. Three systems are simulated using Simcenter Amesim® and MATLAB/Simulink®. Using realistic duty cycles and unit loss models on a circuit for mobile off-road hydraulic equipment, it is shown that a standard LP system can consume about 5 kW of power. Power savings of up to 65% over a standard LP system are demonstrated by the proposed architecture.
- 2 September 2018
- Published by River Publishers in International Journal of Fluid Power
- Vol. 19 (3) , 174
PhD theses completed in 2018
- 2 September 2018
- Published by River Publishers in International Journal of Fluid Power
- Vol. 19 (3) , 174
PhD theses completed in 2018
- 13 February 2018
- Published by River Publishers in International Journal of Fluid Power
- Vol. 19 (2) , 118-124
PhD theses completed in 2018
- 13 February 2018
- Published by River Publishers in International Journal of Fluid Power
- Vol. 19 (2) , 118-124
PhD theses completed in 2018