Kathryn E. Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathryn E. Tanaka has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Brett I. Bell
Department of Family and Social Medicine, Albert Einstein College of Medicine, Bronx, New York
7 shared publications - Chandan Guha
Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY 10461, USA
7 shared publications - Christian Velten
Montefiore Medical Center, Department of Radiation Oncology, Bronx, NY, USA; Albert Einstein College of Medicine, Institute for Onco-Physics, Bronx, NY, USA
7 shared publications - Jeb English
Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York
7 shared publications - Justin Vercellino
Albert Einstein College of Medicine
7 shared publications - Laibin Liu
Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York
7 shared publications
Latest Publications
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects.Significance:Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessData from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects.Significance:Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 3 August 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (15) , 2678-2691
Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects. Significance: Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 3 August 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (15) , 2678-2691
Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects. Significance: Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- Open Access
Increased Relative Biological Effectiveness of Orthovoltage X-rays Compared to γ-rays in Preclinical Irradiation
Purpose: Radionuclide irradiators ( 137 Cs and 60 Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. There are institutional initiatives to replace radionuclide sources with lower-energy X-ray sources amidst concerns of radiological terrorism. As researchers transition, there are questions whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays, since different energy may cause different biological effects. We, therefore, sought to compare the effects of orthovoltage X-rays and 137 Cs γ-rays using mouse models of acute radiation syndrome. Experimental Design: 137 Cs γ-rays were compared with Orthovoltage X-rays, generated at 300 kVp, 10 mA with 1 mm Cu or Thoraeus filtration. We assessed 30-day overall survival following whole-body irradiation and calculated LD 50 by logistic regression. Comparing equivalent doses delivered with different average energies (Ē), we assessed bone marrow, spleen, and intestinal histology and flow cytometry. Results: The LD 50 doses are 6.7 Gy, 7.4 Gy and 8.1 Gy with 1 mm Cu filtered (Ē=120 keV), and Thoraeus filtered X-rays (Ē=160 keV), and 137 Cs (E=662 keV), respectively. At constant dose, hematopoietic injury was most severe with 1 mm Cu filtered X-rays with the greatest reduction in bone marrow cellularity, stem and progenitor populations, and intestinal crypts and OLFM4 + intestinal stem cells. Thoraeus filtered X-rays provoked an intermediate phenotype, with 137 Cs showing the least damage. Conclusions: Our study reveals a dichotomy between physical dose and biological effect relevant as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose-reduction to achieve comparable biological effects. Statement of Translational Relevance: Radiation is used in translational studies in fields ranging from hematopoiesis and stem cell biology to cancer radiotherapy, with 137 Cs and 60 Co radionuclide sources serving as the most common irradiators. Due to the threat of radiological terrorism using stolen radionuclides, there are institutional initiatives to replace these sources with orthovoltage X-ray irradiators. Yet, as shown in this study, the biological effects of radiation are highly dependent on radiation energy. Lower energy orthovoltage X-rays are absorbed differently than higher energy radionuclide γ-rays, provoking more severe hematopoietic, immunologic, and gastrointestinal radiation injury. Thus, an identical physical dose delivered with beams of differing energy does not produce the same biologic effect. As researchers transition between these sources, it is critical that we appreciate that radiation doses are not interchangeable between them. Understanding the significance of physical dose delivered using different methods will allow us to contextualize past results with future studies.
Open AccessIncreased Relative Biological Effectiveness of Orthovoltage X-rays Compared to γ-rays in Preclinical Irradiation
Purpose: Radionuclide irradiators ( 137 Cs and 60 Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. There are institutional initiatives to replace radionuclide sources with lower-energy X-ray sources amidst concerns of radiological terrorism. As researchers transition, there are questions whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays, since different energy may cause different biological effects. We, therefore, sought to compare the effects of orthovoltage X-rays and 137 Cs γ-rays using mouse models of acute radiation syndrome. Experimental Design: 137 Cs γ-rays were compared with Orthovoltage X-rays, generated at 300 kVp, 10 mA with 1 mm Cu or Thoraeus filtration. We assessed 30-day overall survival following whole-body irradiation and calculated LD 50 by logistic regression. Comparing equivalent doses delivered with different average energies (Ē), we assessed bone marrow, spleen, and intestinal histology and flow cytometry. Results: The LD 50 doses are 6.7 Gy, 7.4 Gy and 8.1 Gy with 1 mm Cu filtered (Ē=120 keV), and Thoraeus filtered X-rays (Ē=160 keV), and 137 Cs (E=662 keV), respectively. At constant dose, hematopoietic injury was most severe with 1 mm Cu filtered X-rays with the greatest reduction in bone marrow cellularity, stem and progenitor populations, and intestinal crypts and OLFM4 + intestinal stem cells. Thoraeus filtered X-rays provoked an intermediate phenotype, with 137 Cs showing the least damage. Conclusions: Our study reveals a dichotomy between physical dose and biological effect relevant as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose-reduction to achieve comparable biological effects. Statement of Translational Relevance: Radiation is used in translational studies in fields ranging from hematopoiesis and stem cell biology to cancer radiotherapy, with 137 Cs and 60 Co radionuclide sources serving as the most common irradiators. Due to the threat of radiological terrorism using stolen radionuclides, there are institutional initiatives to replace these sources with orthovoltage X-ray irradiators. Yet, as shown in this study, the biological effects of radiation are highly dependent on radiation energy. Lower energy orthovoltage X-rays are absorbed differently than higher energy radionuclide γ-rays, provoking more severe hematopoietic, immunologic, and gastrointestinal radiation injury. Thus, an identical physical dose delivered with beams of differing energy does not produce the same biologic effect. As researchers transition between these sources, it is critical that we appreciate that radiation doses are not interchangeable between them. Understanding the significance of physical dose delivered using different methods will allow us to contextualize past results with future studies.