Ting Yin
Ting Yin has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Qing Fu
Department of Radiology, Union hospital, Tongji Medical College, Huazhong University of Science and Technology
2 shared publications - Thomas Benkert
MR Application Predevelopment, Siemens Healthineers AG, 91052 Erlangen, Germany
2 shared publications - Chantal Van Ongeval
Department of Radiology, University Hospital Leuven, Herestraat 49, Box 7003, 3000 Leuven, Belgium
1 shared publication - Chuansheng Zheng
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication - Chun-Chao Xia
Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
1 shared publication - Dao-Yu Hu
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
1 shared publication
Latest Publications
- Open Access
- 29 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3170
Comparison of Pulmonary Nodule Morphology on Pre-Contrast and Delayed Post-Contrast Stack-of-Spirals Ultrashort Echo Time MRI
Background: Stack-of-spirals ultrashort TE (spiral-UTE) MRI has shown promise for radiation-free pulmonary nodule detection, and previous studies have reported closely matched observed pulmonary nodule detection rates between contrast-enhanced (UTEe) and unenhanced (UTEu) acquisitions. However, whether this performance extends to detailed lesion-level morphological characterization and whether delayed post-contrast spiral-UTE provides additional morphological information compared with the pre-contrast acquisition under the clinical imaging protocol remain incompletely understood. Therefore, this study compared UTEu and UTEe for lesion-level morphological assessment using CT as the reference standard. Methods: A total of 61 patients with pulmonary nodules/masses (>5 mm) identified on chest CT were enrolled. Patients underwent spiral-UTE MRI on either a 1.5 T scanner (27 patients, 63 lesions) or a 3.0-T scanner (34 patients, 101 lesions). Two fixed consensus reader panels with different experience profiles evaluated lesion visualization and detailed morphological features separately on sequential pre-contrast UTEu and delayed post-contrast UTEe. Two complementary morphology analyses were performed. First, end-to-end successful characterization was assessed across all CT-detected eligible lesions; for each feature, successful characterization required both lesion visualization on the corresponding UTE acquisition and correct feature classification relative to CT. Nonvisualized lesions were designated not characterizable and therefore unsuccessful for this composite outcome. Second, conditional sensitivity, specificity, and accuracy were evaluated among lesions visualized on both UTEu and UTEe to compare morphology interpretation after successful lesion visualization. Lesion size agreement, contrast-to-noise ratio (CNR), and edge sharpness were also evaluated. Results: CT identified 164 lesions, of which the experienced consensus panel visualized 113/164 lesions (68.9%) on both UTEu and UTEe, three on UTEu only, three on UTEe only, and 45 on neither; the inexperienced panel visualized 93/164 lesions (56.7%) on UTEu and 91/164 (55.5%) on UTEe; 91 lesions were visible on both acquisitions, two on UTEu only, none on UTEe only, and 71 on neither. In field-strength-stratified end-to-end analyses, successful-characterization rates ranged from 55 to 71% for UTEe, and 51 to 71% for UTEu derived from experienced reader panel. Among common-visible lesions, no statistically detectable UTEu–UTEe differences were demonstrated for most evaluated morphological features. Conclusions: Across all CT-detected lesions, the ability of spiral-UTE to accurately characterize pulmonary nodule morphology was constrained by incomplete lesion visualization. Our analyses did not demonstrate a statistically detectable UTEu–UTEe difference for most evaluated morphological features. Among UTE-visible lesions, both acquisitions showed relatively high accuracy for several morphological features.
- 29 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3170
Open AccessComparison of Pulmonary Nodule Morphology on Pre-Contrast and Delayed Post-Contrast Stack-of-Spirals Ultrashort Echo Time MRI
Background: Stack-of-spirals ultrashort TE (spiral-UTE) MRI has shown promise for radiation-free pulmonary nodule detection, and previous studies have reported closely matched observed pulmonary nodule detection rates between contrast-enhanced (UTEe) and unenhanced (UTEu) acquisitions. However, whether this performance extends to detailed lesion-level morphological characterization and whether delayed post-contrast spiral-UTE provides additional morphological information compared with the pre-contrast acquisition under the clinical imaging protocol remain incompletely understood. Therefore, this study compared UTEu and UTEe for lesion-level morphological assessment using CT as the reference standard. Methods: A total of 61 patients with pulmonary nodules/masses (>5 mm) identified on chest CT were enrolled. Patients underwent spiral-UTE MRI on either a 1.5 T scanner (27 patients, 63 lesions) or a 3.0-T scanner (34 patients, 101 lesions). Two fixed consensus reader panels with different experience profiles evaluated lesion visualization and detailed morphological features separately on sequential pre-contrast UTEu and delayed post-contrast UTEe. Two complementary morphology analyses were performed. First, end-to-end successful characterization was assessed across all CT-detected eligible lesions; for each feature, successful characterization required both lesion visualization on the corresponding UTE acquisition and correct feature classification relative to CT. Nonvisualized lesions were designated not characterizable and therefore unsuccessful for this composite outcome. Second, conditional sensitivity, specificity, and accuracy were evaluated among lesions visualized on both UTEu and UTEe to compare morphology interpretation after successful lesion visualization. Lesion size agreement, contrast-to-noise ratio (CNR), and edge sharpness were also evaluated. Results: CT identified 164 lesions, of which the experienced consensus panel visualized 113/164 lesions (68.9%) on both UTEu and UTEe, three on UTEu only, three on UTEe only, and 45 on neither; the inexperienced panel visualized 93/164 lesions (56.7%) on UTEu and 91/164 (55.5%) on UTEe; 91 lesions were visible on both acquisitions, two on UTEu only, none on UTEe only, and 71 on neither. In field-strength-stratified end-to-end analyses, successful-characterization rates ranged from 55 to 71% for UTEe, and 51 to 71% for UTEu derived from experienced reader panel. Among common-visible lesions, no statistically detectable UTEu–UTEe differences were demonstrated for most evaluated morphological features. Conclusions: Across all CT-detected lesions, the ability of spiral-UTE to accurately characterize pulmonary nodule morphology was constrained by incomplete lesion visualization. Our analyses did not demonstrate a statistically detectable UTEu–UTEe difference for most evaluated morphological features. Among UTE-visible lesions, both acquisitions showed relatively high accuracy for several morphological features.
- 3 September 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (4) , 1880-1894
Enhanced diagnostic performance of WE-SHARP-DWI compared with SPAIR-DWI for focal liver lesion evaluation at 3T
Purpose This study aimed to compare the diagnostic performance of 2 fat suppression techniques in diffusion-weighted imaging (DWI) for detecting and assessing focal liver lesions (FLLs): water excitation spectral heterogeneity adaptive radiofrequency pulses (WE-SHARP) and conventional spectral adiabatic inversion recovery (SPAIR). Materials and methods This prospective study enrolled eligible participants between October 2023 and August 2024. Various DWI techniques at 3T, SPAIR-DWI, WE-SHARP-DWI, and WE-SHARP-DWI with correction algorithms (WE-SHARP-DWI*), acquired at b values of 50, 400, 800, and 1200 s/mm², were used to evaluate FLLs. Two radiologists independently assessed several subjective image quality parameters: liver edge sharpness, vessel delineation, lesion conspicuity, fat suppression effectiveness, artifacts, and overall image quality. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values were also measured. The diagnostic performance of all 3 sequences was evaluated using receiver operating characteristic (ROC) curve analysis. Results The study included 158 patients (67 with malignant and 91 with benign lesions) and 25 volunteers. Compared with SPAIR-DWI, the subjective image quality parameters were superior for both WE-SHARP sequences (P < .001). SNR increased 2.15-fold with WE-SHARP-DWI and 2.93-fold with WE-SHARP-DWI*. CNR also improved substantially with the WE-SHARP sequences (30.75 ± 36.83 and 42.43 ± 53.23 vs. 13.49 ± 14.39). Further, WE-SHARP sequences demonstrated lower ADC measurement variability with lower standard deviations (32.80 ± 19.13 × 10⁻³ mm²/s and 34.39 ± 18.22 × 10⁻³ mm²/s vs. 51.48 ± 17.89 × 10⁻³ mm²/s) in normal liver and more pronounced ADC differences between benign and malignant lesions (1179 × 10⁻3 mm²/s and 1197 × 10⁻3 mm²/s vs. 1009 × 10⁻3 mm²/s.). The WE-SHARP-DWI techniques demonstrated improved diagnostic performance with higher sensitivity (0.95 vs. 0.88) and greater area under the ROC curve (0.98 vs. 0.95) compared with SPAIR-DWI. Conclusions Both WE-SHARP-DWI techniques demonstrated superior image quality and diagnostic value for assessing FLLs than the conventional SPAIR technique. These techniques retained clinically acceptable image quality even at high b values.
- 3 September 2025
- Published by Springer Nature in Abdominal Radiology
- Vol. 51 (4) , 1880-1894
Enhanced diagnostic performance of WE-SHARP-DWI compared with SPAIR-DWI for focal liver lesion evaluation at 3T
Purpose This study aimed to compare the diagnostic performance of 2 fat suppression techniques in diffusion-weighted imaging (DWI) for detecting and assessing focal liver lesions (FLLs): water excitation spectral heterogeneity adaptive radiofrequency pulses (WE-SHARP) and conventional spectral adiabatic inversion recovery (SPAIR). Materials and methods This prospective study enrolled eligible participants between October 2023 and August 2024. Various DWI techniques at 3T, SPAIR-DWI, WE-SHARP-DWI, and WE-SHARP-DWI with correction algorithms (WE-SHARP-DWI*), acquired at b values of 50, 400, 800, and 1200 s/mm², were used to evaluate FLLs. Two radiologists independently assessed several subjective image quality parameters: liver edge sharpness, vessel delineation, lesion conspicuity, fat suppression effectiveness, artifacts, and overall image quality. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values were also measured. The diagnostic performance of all 3 sequences was evaluated using receiver operating characteristic (ROC) curve analysis. Results The study included 158 patients (67 with malignant and 91 with benign lesions) and 25 volunteers. Compared with SPAIR-DWI, the subjective image quality parameters were superior for both WE-SHARP sequences (P < .001). SNR increased 2.15-fold with WE-SHARP-DWI and 2.93-fold with WE-SHARP-DWI*. CNR also improved substantially with the WE-SHARP sequences (30.75 ± 36.83 and 42.43 ± 53.23 vs. 13.49 ± 14.39). Further, WE-SHARP sequences demonstrated lower ADC measurement variability with lower standard deviations (32.80 ± 19.13 × 10⁻³ mm²/s and 34.39 ± 18.22 × 10⁻³ mm²/s vs. 51.48 ± 17.89 × 10⁻³ mm²/s) in normal liver and more pronounced ADC differences between benign and malignant lesions (1179 × 10⁻3 mm²/s and 1197 × 10⁻3 mm²/s vs. 1009 × 10⁻3 mm²/s.). The WE-SHARP-DWI techniques demonstrated improved diagnostic performance with higher sensitivity (0.95 vs. 0.88) and greater area under the ROC curve (0.98 vs. 0.95) compared with SPAIR-DWI. Conclusions Both WE-SHARP-DWI techniques demonstrated superior image quality and diagnostic value for assessing FLLs than the conventional SPAIR technique. These techniques retained clinically acceptable image quality even at high b values.
- Open Access
- 7 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 901
Feasibility and Reproducibility of T2 Mapping Compared with Diffusion-Weighted Imaging in Solid Renal Masses
Accurate prediction of renal mass subtypes, along with the WHO/ISUP grade and pathological T (pT) stage of clear cell renal cell carcinoma (ccRCC), is crucial for optimal decision making. Our study aimed to investigate the feasibility and reproducibility of motion-robust radial T2 mapping in differentiating lipid-poor angiomyolipoma (MFAML) from RCC and characterizing the WHO/ISUP grade and pT stage of ccRCC. Finally, 92 patients undergoing renal radial T2 mapping and ZOOMit DWI were recruited. The T2 values and apparent diffusion coefficient (ADC) were analyzed. Correlation coefficients were calculated between ADC and T2 values. Notably, ccRCC exhibited higher T2 and ADC values than MFAML (p < 0.05). T2 values were lower in the higher WHO/ISUP grade and pT stage of ccRCC (all p < 0.05). ADC showed no significant difference for pT stage (p = 0.056). T2 values revealed a higher area under the curve (AUC) in evaluating the WHO/ISUP grade compared to ADC (0.936 vs. 0.817, p = 0.027). T2 values moderately positively correlated with ADC (r = 0.675, p < 0.001). In conclusion, quantitative motion-robust radial T2 mapping is feasible for characterizing solid renal masses and could provide additional value for multiparametric imaging in predicting WHO/ISUP grade and pT stage of ccRCC.
- 7 September 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (9) , 901
Open AccessFeasibility and Reproducibility of T2 Mapping Compared with Diffusion-Weighted Imaging in Solid Renal Masses
Accurate prediction of renal mass subtypes, along with the WHO/ISUP grade and pathological T (pT) stage of clear cell renal cell carcinoma (ccRCC), is crucial for optimal decision making. Our study aimed to investigate the feasibility and reproducibility of motion-robust radial T2 mapping in differentiating lipid-poor angiomyolipoma (MFAML) from RCC and characterizing the WHO/ISUP grade and pT stage of ccRCC. Finally, 92 patients undergoing renal radial T2 mapping and ZOOMit DWI were recruited. The T2 values and apparent diffusion coefficient (ADC) were analyzed. Correlation coefficients were calculated between ADC and T2 values. Notably, ccRCC exhibited higher T2 and ADC values than MFAML (p < 0.05). T2 values were lower in the higher WHO/ISUP grade and pT stage of ccRCC (all p < 0.05). ADC showed no significant difference for pT stage (p = 0.056). T2 values revealed a higher area under the curve (AUC) in evaluating the WHO/ISUP grade compared to ADC (0.936 vs. 0.817, p = 0.027). T2 values moderately positively correlated with ADC (r = 0.675, p < 0.001). In conclusion, quantitative motion-robust radial T2 mapping is feasible for characterizing solid renal masses and could provide additional value for multiparametric imaging in predicting WHO/ISUP grade and pT stage of ccRCC.
- 24 June 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (2) , 243-253
Simultaneous multi-slice technique for reducing acquisition times in diffusion tensor imaging of the knee: a feasibility study
Objectives To explore the feasibility of simultaneous multi-slice (SMS) technique for reducing acquisition times in readout-segmented echo planar imaging (RESOLVE) for diffusion tensor imaging (DTI) of the knee. Materials and methods A total of 30 healthy volunteers and 23 patients with knee acute injury (12 cases with anterior ligament (ACL) tears and 16 cases with patellar cartilage (PC) injury) were enrolled in this prospective study. Three DTI protocols were used: conventional RESOLVE-DTI with 12 directions (protocol 1), SMS-RESOLVE-DTI with 12 directions (protocol 2) and 20 directions (protocol 3). DTI parameters of gastrocnemius, ACL and posterior cruciate ligament (PCL), and PC from three protocols were quantitatively assessed. Results For volunteers, protocol 2 significantly reduced acquisition time by 38.6% and 34.2% compared to protocols 1 and 3 while maintaining similar high-quality images and similar diffusive parameters, except for the fractional anisotropy (FA) and axial diffusivity (AD) of the PC between protocols 2 and 1 (P < 0.05). For injured ACL and PC, protocols 1 and 2 showed similar accurate diffusive parameters (except for AD, P = 0.025) and similar diagnostic efficacy, which demonstrated significantly lower FA and higher radial diffusivity (RD) in protocols 1 and 2 compared to volunteers (P < 0.05). Conclusions The 12-direction SMS-RESOLVE-DTI demonstrated a favorable balance between acquisition time and image quality, making it a promising alternative to conventional DTI for evaluating ligament and cartilage injuries. Advances in knowledge The SMS technique greatly reduces acquisition time while maintaining image quality, which signified the possibility of DTI’s clinical application.
- 24 June 2024
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (2) , 243-253
Simultaneous multi-slice technique for reducing acquisition times in diffusion tensor imaging of the knee: a feasibility study
Objectives To explore the feasibility of simultaneous multi-slice (SMS) technique for reducing acquisition times in readout-segmented echo planar imaging (RESOLVE) for diffusion tensor imaging (DTI) of the knee. Materials and methods A total of 30 healthy volunteers and 23 patients with knee acute injury (12 cases with anterior ligament (ACL) tears and 16 cases with patellar cartilage (PC) injury) were enrolled in this prospective study. Three DTI protocols were used: conventional RESOLVE-DTI with 12 directions (protocol 1), SMS-RESOLVE-DTI with 12 directions (protocol 2) and 20 directions (protocol 3). DTI parameters of gastrocnemius, ACL and posterior cruciate ligament (PCL), and PC from three protocols were quantitatively assessed. Results For volunteers, protocol 2 significantly reduced acquisition time by 38.6% and 34.2% compared to protocols 1 and 3 while maintaining similar high-quality images and similar diffusive parameters, except for the fractional anisotropy (FA) and axial diffusivity (AD) of the PC between protocols 2 and 1 (P < 0.05). For injured ACL and PC, protocols 1 and 2 showed similar accurate diffusive parameters (except for AD, P = 0.025) and similar diagnostic efficacy, which demonstrated significantly lower FA and higher radial diffusivity (RD) in protocols 1 and 2 compared to volunteers (P < 0.05). Conclusions The 12-direction SMS-RESOLVE-DTI demonstrated a favorable balance between acquisition time and image quality, making it a promising alternative to conventional DTI for evaluating ligament and cartilage injuries. Advances in knowledge The SMS technique greatly reduces acquisition time while maintaining image quality, which signified the possibility of DTI’s clinical application.
- Open Access
- 1 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 344
Turbo Gradient and Spin-Echo BLADE-DWI for Extraocular Muscles in Thyroid-Associated Ophthalmopathy
Purpose: To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Materials and methods: Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale. The maximum size (Sizemax) of EOMs and corresponding ADCs (cADCs) of each patient were compared between the active and inactive phases. The clinical activity score (CAS) was used as a reference to assess the diagnostic performance of EOM ADCs for grading TAO activity. ROC analysis, Pearson correlation, and Wilcoxon signed-rank test were used for statistical analyses. Results: For scores of EOMs, the image quality of TGSE-BLADE-DWI was significantly higher than that of RESOLVE. There were no statistically significant differences between the AUCs of the two DWIs, Sizemax, or cADCs between the active and inactive phases. TGSE-BLADE-DWI ADCs were significantly higher than the RESOLVE ADCs in the right superior rectus, right lateral rectus, left superior rectus, and left inferior rectus. There were no statistically significant correlations between the cADC or Sizemax, and CAS. The highest AUC was 0.697 for RESOLVE and 0.657 for TGSE-BLADE-DWI. The best performing ADC threshold was 1.85 × 10−3 mm2/s with 85.7% sensitivity, 58.8% specificity and 66.67% accuracy for RESOLVE and 1.99 × 10−3 mm2/s with 79.0% sensitivity, and 55.6% specificity and 65.27% accuracy for TGSE-BLADE-DWI. Conclusion: Compared to RESOLVE, TGSE-BLADE-DWI provided improved image quality with fewer susceptibility artifacts and geometric distortions for EOM visualization and showed an equivalent performance in detecting active TAO.
- 1 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (1) , 344
Open AccessTurbo Gradient and Spin-Echo BLADE-DWI for Extraocular Muscles in Thyroid-Associated Ophthalmopathy
Purpose: To investigate feasibility and diagnostic performance of turbo gradient and spin-echo BLADE (proprietary name for Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction [PROPELLER] in Siemens MR systems)-diffusion weighted imaging (TGSE-BLADE-DWI) for depicting extraocular muscle (EOM) involvement and activity in thyroid-associated ophthalmopathy (TAO), and to compare TGSE-BLADE-DWI with readout-segmented echo-planar imaging (RESOLVE). Materials and methods: Thirty-five patients with identified TAO underwent the two DWI scans. Two radiologists visually scored the image quality of the two DWIs with respect to the susceptibility artifacts and geometric distortions on a three-point scale. The maximum size (Sizemax) of EOMs and corresponding ADCs (cADCs) of each patient were compared between the active and inactive phases. The clinical activity score (CAS) was used as a reference to assess the diagnostic performance of EOM ADCs for grading TAO activity. ROC analysis, Pearson correlation, and Wilcoxon signed-rank test were used for statistical analyses. Results: For scores of EOMs, the image quality of TGSE-BLADE-DWI was significantly higher than that of RESOLVE. There were no statistically significant differences between the AUCs of the two DWIs, Sizemax, or cADCs between the active and inactive phases. TGSE-BLADE-DWI ADCs were significantly higher than the RESOLVE ADCs in the right superior rectus, right lateral rectus, left superior rectus, and left inferior rectus. There were no statistically significant correlations between the cADC or Sizemax, and CAS. The highest AUC was 0.697 for RESOLVE and 0.657 for TGSE-BLADE-DWI. The best performing ADC threshold was 1.85 × 10−3 mm2/s with 85.7% sensitivity, 58.8% specificity and 66.67% accuracy for RESOLVE and 1.99 × 10−3 mm2/s with 79.0% sensitivity, and 55.6% specificity and 65.27% accuracy for TGSE-BLADE-DWI. Conclusion: Compared to RESOLVE, TGSE-BLADE-DWI provided improved image quality with fewer susceptibility artifacts and geometric distortions for EOM visualization and showed an equivalent performance in detecting active TAO.
- 26 February 2022
- Published by Springer Nature in Clinical & Experimental Metastasis
- Vol. 39 (3) , 479-493
Development and characterization of a rat brain metastatic tumor model by multiparametric magnetic resonance imaging and histomorphology
To facilitate the development of new brain metastasis (BM) treatment, an easy-to-use and clinically relevant animal model with imaging platform is needed. Rhabdomyosarcoma BM was induced in WAG/Rij rats. Post-implantation surveillance and characterizations were systematically performed with multiparametric MRI including 3D T1 and T2 weighted imaging, diffusion-weighted imaging (DWI), T1 and T2 mapping, and perfusion-weighted imaging (PWI), which were validated by postmortem digital radiography (DR), µCT angiography and histopathology. The translational potential was exemplified by the application of a vascular disrupting agent (VDA). BM was successfully induced in most rats of both genders (18/20). Multiparametric MRI revealed significantly higher T2 value, pre-contrast-enhanced (preCE) T1 value, DWI-derived apparent diffusion coefficient (ADC) and CE ratio, but a lower post-contrast-enhanced (postCE) T1 value in BM lesions than in adjacent brain (p < 0.01). PWI showed the dynamic and higher contrast agent uptake in the BM compared with the adjacent brain. DR, µCT and histopathology characterized the BM as hypervascular tumors. After VDA treatment, the BM showed drug-related perfusion changes and partial necrosis as evidenced by anatomical, functional MRI parameters and postmortem findings. The present BM model and imaging modalities represent a feasible and translational platform for developing BM-targeting therapeutics.
- 26 February 2022
- Published by Springer Nature in Clinical & Experimental Metastasis
- Vol. 39 (3) , 479-493
Development and characterization of a rat brain metastatic tumor model by multiparametric magnetic resonance imaging and histomorphology
To facilitate the development of new brain metastasis (BM) treatment, an easy-to-use and clinically relevant animal model with imaging platform is needed. Rhabdomyosarcoma BM was induced in WAG/Rij rats. Post-implantation surveillance and characterizations were systematically performed with multiparametric MRI including 3D T1 and T2 weighted imaging, diffusion-weighted imaging (DWI), T1 and T2 mapping, and perfusion-weighted imaging (PWI), which were validated by postmortem digital radiography (DR), µCT angiography and histopathology. The translational potential was exemplified by the application of a vascular disrupting agent (VDA). BM was successfully induced in most rats of both genders (18/20). Multiparametric MRI revealed significantly higher T2 value, pre-contrast-enhanced (preCE) T1 value, DWI-derived apparent diffusion coefficient (ADC) and CE ratio, but a lower post-contrast-enhanced (postCE) T1 value in BM lesions than in adjacent brain (p < 0.01). PWI showed the dynamic and higher contrast agent uptake in the BM compared with the adjacent brain. DR, µCT and histopathology characterized the BM as hypervascular tumors. After VDA treatment, the BM showed drug-related perfusion changes and partial necrosis as evidenced by anatomical, functional MRI parameters and postmortem findings. The present BM model and imaging modalities represent a feasible and translational platform for developing BM-targeting therapeutics.