Shanthala Lakshminarayana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shanthala Lakshminarayana has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hyusim Park
Department of Electrical Engineering, University of North Texas, Dallas, TX, USA
9 shared publications - Sungyong Jung
Department of Electrical Engineering and Computer Science, South Dakota State University, Brookings, SD, USA
9 shared publications - Chenyun Pan
The University of Texas at Arlington, Arlington, TX, USA
3 shared publications - Hoon-Ju Chung
School of Electronic Engineering, Kumoh National Institute of Technology, Gumi, Gyeongsangbuk-do, South Korea
3 shared publications - Younghun Park
Electrical Engineering Department, The University of Texas at Arlington, Arlington, TX, USA
3 shared publications - Yuze Sun
University of Texas at Arlington
2 shared publications
Latest Publications
- Open Access
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 105434-105445
Detection of Cisplatin Resistance in Bladder Cancer Using Machine Learning
Bladder Cancer (BC) is the ninth most common cancer worldwide, with cisplatin-based chemotherapy being a standard treatment. However, the emergence of cisplatin resistance poses significant challenges, contributing to high recurrence rates. This study investigates the mechanisms of cisplatin resistance in BC through the application of Machine Learning (ML) models, including Association Rule Mining, K-mode Clustering, and Decision Tree Classifier. By analyzing large-scale genomic data, we uncover the molecular pathways driving resistance. Specifically, our findings show that hypermethylation of CpG islands, such as those in UCSC_CPG_ISLANDS and GENOME_BUILD_37, leads to reduced cell accessibility, contributing to cisplatin resistance. The ML models highlight strong associations between hypermethylation and cell inaccessibility, with 99% confidence. This work provides valuable insights into the role of methylation patterns in BC recurrence and offers potential for personalized therapeutic strategies aimed at overcoming cisplatin resistance and improving clinical outcomes.
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 105434-105445
Open AccessDetection of Cisplatin Resistance in Bladder Cancer Using Machine Learning
Bladder Cancer (BC) is the ninth most common cancer worldwide, with cisplatin-based chemotherapy being a standard treatment. However, the emergence of cisplatin resistance poses significant challenges, contributing to high recurrence rates. This study investigates the mechanisms of cisplatin resistance in BC through the application of Machine Learning (ML) models, including Association Rule Mining, K-mode Clustering, and Decision Tree Classifier. By analyzing large-scale genomic data, we uncover the molecular pathways driving resistance. Specifically, our findings show that hypermethylation of CpG islands, such as those in UCSC_CPG_ISLANDS and GENOME_BUILD_37, leads to reduced cell accessibility, contributing to cisplatin resistance. The ML models highlight strong associations between hypermethylation and cell inaccessibility, with 99% confidence. This work provides valuable insights into the role of methylation patterns in BC recurrence and offers potential for personalized therapeutic strategies aimed at overcoming cisplatin resistance and improving clinical outcomes.
- Open Access
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 52324-52333
Smartphone Enabled Wearable Diabetes Monitoring System
Glucose is a vital biomarker involved in numerous physiological and pathological processes, making its detection a key factor in diabetes monitoring. To enhance convenience, real-time tracking, comfort, and accuracy, glucose measurement techniques are rapidly advancing towards smartphone integrated wearable, non-invasive, and low power systems. In this work, a diabetes monitoring system is developed which can be used as a wearable health tracker. The device offers dual ways of monitoring glucose levels in diabetic patients; first by glucose measurement via blood using a screen-printed electrode sensor (SPES), second by volatile organic compounds (VOCs) measurement via breath analysis using an ethanol sensor. Additionally, an oximetry sensor is included in the system to monitor important human vitals such as heart rate and blood oxygen saturation (SpO2), similar to commercial health trackers. The system is fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized Windows and Android applications have been developed to visualize the obtained data in user’s computer or smartphone. The conducted experiments aimed at validating the performance of each sensors have yielded promising results. These findings indicate that the developed system has significant potential to be utilized as a point-of-care testing device for real-time diabetes monitoring.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 52324-52333
Open AccessSmartphone Enabled Wearable Diabetes Monitoring System
Glucose is a vital biomarker involved in numerous physiological and pathological processes, making its detection a key factor in diabetes monitoring. To enhance convenience, real-time tracking, comfort, and accuracy, glucose measurement techniques are rapidly advancing towards smartphone integrated wearable, non-invasive, and low power systems. In this work, a diabetes monitoring system is developed which can be used as a wearable health tracker. The device offers dual ways of monitoring glucose levels in diabetic patients; first by glucose measurement via blood using a screen-printed electrode sensor (SPES), second by volatile organic compounds (VOCs) measurement via breath analysis using an ethanol sensor. Additionally, an oximetry sensor is included in the system to monitor important human vitals such as heart rate and blood oxygen saturation (SpO2), similar to commercial health trackers. The system is fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized Windows and Android applications have been developed to visualize the obtained data in user’s computer or smartphone. The conducted experiments aimed at validating the performance of each sensors have yielded promising results. These findings indicate that the developed system has significant potential to be utilized as a point-of-care testing device for real-time diabetes monitoring.
- Open Access
- 19 January 2025
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 15 (1) , 3
A CMOS Switched Capacitor Filter Based Potentiometric Readout Circuit for pH Sensing System
This work presents a potentiometric readout circuit for a pH-sensing system in an oral healthcare device. For in vivo applications, noise, area, and power consumption of the readout electronics play critical roles. While CMOS amplifiers are commonly used in readout circuits for these applications, their applicability is limited due to non-deterministic noises such as flicker and thermal noise. To address these challenges, the Correlated Double Sampler (CDS) topology is widely employed as a sampled-data circuit for potentiometric readout, effectively eliminating DC offset and drift, thereby reducing overall noise. Therefore, this work introduces a novel potentiometric readout circuit realized with CDS and a switched-capacitor-based low-pass filter (SC-LPF) to enhance the noise characteristic of overall circuit. The proposed readout circuit is implemented in an integrated circuit using 0.18 µm CMOS process, which occupies an area of 990 µm × 216 µm. To validate the circuit performances, simulations were conducted with a 5 pF load and a 1 MHz input clock. The readout circuit operates with a supply voltage range ±1.65 V and linearly reproduces the pH sensor output of ±1.5 V. Noise measured with a 1 MHz sampling clock shows 0.683 µ, with a power consumption of 124.1 µW.- 19 January 2025
- Published by MDPI AG in Journal of Low Power Electronics and Applications
- Vol. 15 (1) , 3
Open AccessA CMOS Switched Capacitor Filter Based Potentiometric Readout Circuit for pH Sensing System
This work presents a potentiometric readout circuit for a pH-sensing system in an oral healthcare device. For in vivo applications, noise, area, and power consumption of the readout electronics play critical roles. While CMOS amplifiers are commonly used in readout circuits for these applications, their applicability is limited due to non-deterministic noises such as flicker and thermal noise. To address these challenges, the Correlated Double Sampler (CDS) topology is widely employed as a sampled-data circuit for potentiometric readout, effectively eliminating DC offset and drift, thereby reducing overall noise. Therefore, this work introduces a novel potentiometric readout circuit realized with CDS and a switched-capacitor-based low-pass filter (SC-LPF) to enhance the noise characteristic of overall circuit. The proposed readout circuit is implemented in an integrated circuit using 0.18 µm CMOS process, which occupies an area of 990 µm × 216 µm. To validate the circuit performances, simulations were conducted with a 5 pF load and a 1 MHz input clock. The readout circuit operates with a supply voltage range ±1.65 V and linearly reproduces the pH sensor output of ±1.5 V. Noise measured with a 1 MHz sampling clock shows 0.683 µ, with a power consumption of 124.1 µW. - Open Access
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 180619-180630
A Low-Noise, Low-Offset CMOS Readout IC for Amperometric Biosensors
Electrochemical sensing systems are crucial in driving forward the development of biosensors that is indispensable for health monitoring. In this work, a compact, low-noise, and low-offset CMOS readout circuit has been proposed for amperometric biosensors. It comprises of a transimpedance amplifier, a sample and hold buffer, bias generator, and an on-chip clock generator. A two-step measurement method is introduced to enhance the noise performance and linearity of the signal path. Additionally, a faster and energy-efficient analog autozero scheme is proposed to mitigate amplifier offset and sampled noise, which is a crucial aspect when detecting current in the range of nano-ampere. The proposed readout circuit attains notable specifications, including an input-referred noise of 0.16 pA rms , an input-referred offset of 137 nV, an accuracy level of 2%, and a power consumption of 48 μA from a 1.8V supply. It is designed using a 0.18 μm CMOS process and occupies a compact size of 1.47 mm². This circuit is compatible with a screen-printed electrode sensor and can seamlessly integrate into a flexible printed circuit board. Such integration facilitates its inclusion as a component within a wearable health monitoring system, ensuring expeditious and precise estimation of analyte concentration.
- 29 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 180619-180630
Open AccessA Low-Noise, Low-Offset CMOS Readout IC for Amperometric Biosensors
Electrochemical sensing systems are crucial in driving forward the development of biosensors that is indispensable for health monitoring. In this work, a compact, low-noise, and low-offset CMOS readout circuit has been proposed for amperometric biosensors. It comprises of a transimpedance amplifier, a sample and hold buffer, bias generator, and an on-chip clock generator. A two-step measurement method is introduced to enhance the noise performance and linearity of the signal path. Additionally, a faster and energy-efficient analog autozero scheme is proposed to mitigate amplifier offset and sampled noise, which is a crucial aspect when detecting current in the range of nano-ampere. The proposed readout circuit attains notable specifications, including an input-referred noise of 0.16 pA rms , an input-referred offset of 137 nV, an accuracy level of 2%, and a power consumption of 48 μA from a 1.8V supply. It is designed using a 0.18 μm CMOS process and occupies a compact size of 1.47 mm². This circuit is compatible with a screen-printed electrode sensor and can seamlessly integrate into a flexible printed circuit board. Such integration facilitates its inclusion as a component within a wearable health monitoring system, ensuring expeditious and precise estimation of analyte concentration.
- Open Access
- 11 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (20) , 9267
Trimodal Watch-Type Wearable Health Monitoring Device
In the domain of healthcare, wearable health monitoring devices have emerged as essential tools for the advancement of patient health tracking. These devices facilitate the provision of real-time medical data to clinicians, enabling early diagnosis, timely intervention, and enhanced management of individual health. This study introduces an innovative trimodal wearable health monitoring device in the form of a wristwatch. The device integrates a breath analyzer for the assessment of gaseous phase biomarkers, a sweat analyzer for the evaluation of aqueous-phase biomarkers, and an infrared sensor for the measurement of body temperature in the optical phase. Engineered on a compact 3 cm × 3 cm printed circuit board, the device has been optimized for wearability, power efficiency, and seamless integration with both wired and wireless charging and communication systems. Furthermore, custom software applications, designed for both Windows and Android platforms, have been developed to facilitate intuitive data visualization and storage on personal computers and smartphones. Empirical results from real-time chemical testing substantiate the device’s efficacy and potential as an advanced solution for wearable health monitoring.
- 11 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (20) , 9267
Open AccessTrimodal Watch-Type Wearable Health Monitoring Device
In the domain of healthcare, wearable health monitoring devices have emerged as essential tools for the advancement of patient health tracking. These devices facilitate the provision of real-time medical data to clinicians, enabling early diagnosis, timely intervention, and enhanced management of individual health. This study introduces an innovative trimodal wearable health monitoring device in the form of a wristwatch. The device integrates a breath analyzer for the assessment of gaseous phase biomarkers, a sweat analyzer for the evaluation of aqueous-phase biomarkers, and an infrared sensor for the measurement of body temperature in the optical phase. Engineered on a compact 3 cm × 3 cm printed circuit board, the device has been optimized for wearability, power efficiency, and seamless integration with both wired and wireless charging and communication systems. Furthermore, custom software applications, designed for both Windows and Android platforms, have been developed to facilitate intuitive data visualization and storage on personal computers and smartphones. Empirical results from real-time chemical testing substantiate the device’s efficacy and potential as an advanced solution for wearable health monitoring.
- Open Access
- 1 March 2023
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 2 (1) , 012801
Watch-Type Dual-Mode Wearable Health Device
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.
- 1 March 2023
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 2 (1) , 012801
Open AccessWatch-Type Dual-Mode Wearable Health Device
Wearable devices can be found as numerous types of health devices ranging from monitoring hazardous environments to detecting physiological signals. Its utilities have also shown encouraging improvements toward personalized healthcare. Thus, many kinds of wearable health devices (WHD) have been reported and developed. Those reports highlight their efficiency in monitoring harmful environmental factors and various diseases for diagnostic and treatment purposes. This paper proposes a watch-type of dual-mode WHD that can perform gaseous phase detection to monitor dangerous environmental situations such as bad air quality and aqueous phase detection to measure physiological signals from human sweat or blood. The proposed system was fabricated on a printed circuit board and its size is 3 cm × 3 cm which is suitable as a wearable device. It also consumes very low power and has capabilities of wired/wireless charging and wired/wireless communication. Furthermore, customized windows and Android applications have been developed to visualize obtained data in a user’s computer or smartphone. The system was tested both electrically and chemically and showed promising results as the WHD.
- Open Access
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 68700-68710
Portable All-in-One Electroanalytical Device for Point of Care
Recent technological advancements such as an expansion of available biomarkers and an incremental burden of chronic and infectious diseases made point of care (POC) devices in strong demand. It has a potential to surpass conventional lab-based devices in terms of time, cost, accessibility, and even accuracy. This potential strongly depends on an availability of affordable and miniaturized electronic POC devices that can provide a fast and sensitive response. This paper presents an all-in-one electroanalytical device (AED) which is a cost-effective, field-ready, and miniaturized electronic POC device integrated with the most commonly used electroanalytical techniques such as amperometric, voltammetric, potentiometric, conductometric, and impedimetric techniques. The proposed AED can analyze multiple electrochemical sensors simultaneously while having a very small size of 48 mm $\times37$ mm, including eight disposable screen-printed electrochemical sensor (SPES) connectors. The device supports wired communication using a universal serial bus (USB) and wireless communication with Bluetooth Low Energy (BLE). Furthermore, user-friendly customized Graphical User Interface (GUI) has been developed to control the device and send obtained data to the user. The system is evaluated through electrical tests to confirm the device accuracy. Subsequently, electrochemical experiments were conducted to evaluate device’s performance in the field. These experiments indicated that the developed device operates as an electrochemical sensing device for POC applications. The proposed portable electroanalytical device can perform the most of electroanalytical methods in a single device which has very small form factor and capability to interpret multiple sensors at a time with user friendly interface.
- 27 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 68700-68710
Open AccessPortable All-in-One Electroanalytical Device for Point of Care
Recent technological advancements such as an expansion of available biomarkers and an incremental burden of chronic and infectious diseases made point of care (POC) devices in strong demand. It has a potential to surpass conventional lab-based devices in terms of time, cost, accessibility, and even accuracy. This potential strongly depends on an availability of affordable and miniaturized electronic POC devices that can provide a fast and sensitive response. This paper presents an all-in-one electroanalytical device (AED) which is a cost-effective, field-ready, and miniaturized electronic POC device integrated with the most commonly used electroanalytical techniques such as amperometric, voltammetric, potentiometric, conductometric, and impedimetric techniques. The proposed AED can analyze multiple electrochemical sensors simultaneously while having a very small size of 48 mm $\times37$ mm, including eight disposable screen-printed electrochemical sensor (SPES) connectors. The device supports wired communication using a universal serial bus (USB) and wireless communication with Bluetooth Low Energy (BLE). Furthermore, user-friendly customized Graphical User Interface (GUI) has been developed to control the device and send obtained data to the user. The system is evaluated through electrical tests to confirm the device accuracy. Subsequently, electrochemical experiments were conducted to evaluate device’s performance in the field. These experiments indicated that the developed device operates as an electrochemical sensing device for POC applications. The proposed portable electroanalytical device can perform the most of electroanalytical methods in a single device which has very small form factor and capability to interpret multiple sensors at a time with user friendly interface.
- Open Access
- 25 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 45726-45735
A Readout System for High Speed Interface of Wide Range Chemiresistive Sensor Array
This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1 KΩ - 1 MΩ and 0.1 % sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm × 6 cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88 %, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.
- 25 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 45726-45735
Open AccessA Readout System for High Speed Interface of Wide Range Chemiresistive Sensor Array
This paper aims at designing a compact readout system for chemiresistive sensor array with high speed and high accuracy. The proposed scheme is based on Resistance-to-Voltage (R-V) conversion and targets high density wide ranged chemiresistive sensor, with input resistance range of 1 KΩ - 1 MΩ and 0.1 % sensitivity. The proposed approach uses Adaptive Reference Resistor Tuning (ARRT) technique implemented with a digital variable potentiometer to achieve a high accuracy without sacrificing the dynamic range and the speed. The system is implemented on a printed circuit board with a microcontroller and a 16-bit Analog-to-Digital Converter (ADC), and it has a compact dimension of 10 cm × 6 cm, which is suitable for portable applications. The readout system works with a 5 V power supply, and the overall system power consumption is 150 mW. The system is designed to interface with a 118 sensor array and the experimental results achieved a satisfactory accuracy of 0.88 %, as well as a measuring speed of 8.5 ms per sensor. Compared with existing approaches, our work targets a high density wide ranged chemiresistive sensor array and demonstrated high accuracy, high speed with the lowest circuit complexity, which is the novelty of this work.
- Open Access
- 8 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (8) , 1181
An Auto Adjustable Transimpedance Readout System for Wearable Healthcare Devices
The objective of this work was to design a versatile readout circuit for patch-type wearable devices consisting of a Transimpedance Amplifier (TIA). The TIA performs Current to Voltage (I–V) conversion, the most widely used technique for amperometry and impedance measurement for various types of electrochemical sensors. The proposed readout circuit employs a digitally controllable feedback resistor () technique in the TIA to improve accuracy, which can be utilized in a variety of electrochemical sensors within a current range of 0.1 µA–100 µA. It is designed to accommodate multiple sensors simultaneously to track multiple target analytes for high accuracy and versatile usage. The readout circuit consists of low power operational amplifier (op–amp) and digital circuit blocks, is designed and fabricated with Magna 0.18 µm Complementary Metal Oxide Semiconductor (CMOS) technology, which provides low power consumption and a high degree of integration. The design has a small size of 0.282 and low power consumption of 0.38 mW with a 3.3 V power supply, which are desirable factors in wearable device applications.- 8 April 2022
- Published by MDPI AG in Electronics
- Vol. 11 (8) , 1181
Open AccessAn Auto Adjustable Transimpedance Readout System for Wearable Healthcare Devices
The objective of this work was to design a versatile readout circuit for patch-type wearable devices consisting of a Transimpedance Amplifier (TIA). The TIA performs Current to Voltage (I–V) conversion, the most widely used technique for amperometry and impedance measurement for various types of electrochemical sensors. The proposed readout circuit employs a digitally controllable feedback resistor () technique in the TIA to improve accuracy, which can be utilized in a variety of electrochemical sensors within a current range of 0.1 µA–100 µA. It is designed to accommodate multiple sensors simultaneously to track multiple target analytes for high accuracy and versatile usage. The readout circuit consists of low power operational amplifier (op–amp) and digital circuit blocks, is designed and fabricated with Magna 0.18 µm Complementary Metal Oxide Semiconductor (CMOS) technology, which provides low power consumption and a high degree of integration. The design has a small size of 0.282 and low power consumption of 0.38 mW with a 3.3 V power supply, which are desirable factors in wearable device applications. - Open Access
High Density Resistive Array Readout System for Wearable Electronics
This work presents a wearable sensing system for high-density resistive array readout. The system comprising readout electronics for a high-density resistive sensor array and a rechargeable battery, was realized in a wristband. The analyzed data with the proposed system can be visualized using a custom graphical user interface (GUI) developed in a personal computer (PC) through a universal serial bus (USB) and using an Android app in smartphones via Bluetooth Low Energy (BLE), respectively. The readout electronics were implemented on a printed circuit board (PCB) and had a compact dimension of 3 cm × 3 cm. It was designed to measure the resistive sensor with a dynamic range of 1 KΩ–1 MΩ and detect a 0.1% change of the base resistance. The system operated at a 5 V supply voltage, and the overall system power consumption was 95 mW. The readout circuit employed a resistance-to-voltage (R-V) conversion topology using a 16-bit analog-to-digital converter (ADC), integrated in the Cypress Programmable System-on-Chip (PSoC®) 5LP microcontroller. The device behaves as a universal-type sensing system that can be interfaced with a wide variety of resistive sensors, including chemiresistors, piezoresistors, and thermoelectric sensors, whose resistance variations fall in the target measurement range of 1 KΩ–1 MΩ. The system performance was tested with a 60-resistor array and showed a satisfactory accuracy, with a worst-case error rate up to 2.5%. The developed sensing system shows promising results for applications in the field of the Internet of things (IoT), point-of-care testing (PoCT), and low-cost wearable devices.
Open AccessHigh Density Resistive Array Readout System for Wearable Electronics
This work presents a wearable sensing system for high-density resistive array readout. The system comprising readout electronics for a high-density resistive sensor array and a rechargeable battery, was realized in a wristband. The analyzed data with the proposed system can be visualized using a custom graphical user interface (GUI) developed in a personal computer (PC) through a universal serial bus (USB) and using an Android app in smartphones via Bluetooth Low Energy (BLE), respectively. The readout electronics were implemented on a printed circuit board (PCB) and had a compact dimension of 3 cm × 3 cm. It was designed to measure the resistive sensor with a dynamic range of 1 KΩ–1 MΩ and detect a 0.1% change of the base resistance. The system operated at a 5 V supply voltage, and the overall system power consumption was 95 mW. The readout circuit employed a resistance-to-voltage (R-V) conversion topology using a 16-bit analog-to-digital converter (ADC), integrated in the Cypress Programmable System-on-Chip (PSoC®) 5LP microcontroller. The device behaves as a universal-type sensing system that can be interfaced with a wide variety of resistive sensors, including chemiresistors, piezoresistors, and thermoelectric sensors, whose resistance variations fall in the target measurement range of 1 KΩ–1 MΩ. The system performance was tested with a 60-resistor array and showed a satisfactory accuracy, with a worst-case error rate up to 2.5%. The developed sensing system shows promising results for applications in the field of the Internet of things (IoT), point-of-care testing (PoCT), and low-cost wearable devices.