Kun Wang
Research Subjects
Kun Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Danyue Ma
Beihang University
7 shared publications - Siran Li
Institute of Remote Sensing Satellite, China Academy of Space Technology, Beijing 100094, China
5 shared publications - Yanan Gao
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
5 shared publications Yao Dou
5 shared publications- Jixi Lu
Beihang University
4 shared publications Jinji Sun
3 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Elsevier in Materials & Design
- Vol. 267
Cryogenic dissipation-noise coupling in a Fe-based nanocrystalline soft magnetic alloy: A loss-separation framework with fluctuation analysis and domain-wall insights
- 3 June 2026
- Published by Elsevier in Materials & Design
- Vol. 267
Open AccessCryogenic dissipation-noise coupling in a Fe-based nanocrystalline soft magnetic alloy: A loss-separation framework with fluctuation analysis and domain-wall insights
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 14900-14908
A Combination Solving Method for Multiple Square Coils to Generate Large Uniform Magnetic Field Region for Atomic Magnetometers
Atomic magnetometers have been widely used for the measurement of ultra-weak magnetic signals, while the high-uniformity magnetic fields are required to maintain the stable working environment. The present study proposes a combination solving method (CSM) for the design of multiple square coils (MSCs) to generate uniform magnetic field in confined spaces. Cooperative particle swarm optimization (PSO) algorithm is applied to design the coils with two pairs through five pairs via solving the optimal coil currents and distances. Each additional pair in the designed-coils expands the uniform regions with relative error less than 1% by approximately 6%. The MSCs with three pairs (Pairs-3) achieves excellent uniformity performance with a simple configuration, making it well suited for atomic magnetometers. The maximum relative error in center region is 0.54%, less than Merritt coil (1.39%), Rubens coil (2.18%), and 3-TE coil (2.63%). In addition, numerical simulation and experimental results confirm the validity of the CSM. The new method is of significant importance for designing high-uniformity coils that meet spatial constraints of atomic magnetometers.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 14900-14908
A Combination Solving Method for Multiple Square Coils to Generate Large Uniform Magnetic Field Region for Atomic Magnetometers
Atomic magnetometers have been widely used for the measurement of ultra-weak magnetic signals, while the high-uniformity magnetic fields are required to maintain the stable working environment. The present study proposes a combination solving method (CSM) for the design of multiple square coils (MSCs) to generate uniform magnetic field in confined spaces. Cooperative particle swarm optimization (PSO) algorithm is applied to design the coils with two pairs through five pairs via solving the optimal coil currents and distances. Each additional pair in the designed-coils expands the uniform regions with relative error less than 1% by approximately 6%. The MSCs with three pairs (Pairs-3) achieves excellent uniformity performance with a simple configuration, making it well suited for atomic magnetometers. The maximum relative error in center region is 0.54%, less than Merritt coil (1.39%), Rubens coil (2.18%), and 3-TE coil (2.63%). In addition, numerical simulation and experimental results confirm the validity of the CSM. The new method is of significant importance for designing high-uniformity coils that meet spatial constraints of atomic magnetometers.
- 16 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Design of uniform field coils with ferrite shielding considering coupling effects: An EDM approach
- 16 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Design of uniform field coils with ferrite shielding considering coupling effects: An EDM approach
- 21 April 2024
- Published by Elsevier in Measurement
- Vol. 233
Design and measurement of three-dimensional uniform-field coils based on swarm intelligence algorithms under ferromagnetic boundaries
- 21 April 2024
- Published by Elsevier in Measurement
- Vol. 233
Design and measurement of three-dimensional uniform-field coils based on swarm intelligence algorithms under ferromagnetic boundaries
- 18 April 2024
- Published by Elsevier in Measurement
- Vol. 233
Analysis and measurement of magnetic noise in multilayer magnetic shielding system combined with mu-metal and ferrite for atomic sensors
- 18 April 2024
- Published by Elsevier in Measurement
- Vol. 233
Analysis and measurement of magnetic noise in multilayer magnetic shielding system combined with mu-metal and ferrite for atomic sensors
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Optimal Design of Self-Shielded Biplanar Coil Assembly With Miniaturized Structure
The multi-channel optically-pumped magnetometer (OPM) system can experience crosstalk between adjacent sensors owing to the magnetic field generated by the magnetic coil. To mitigate this issue, this study proposes a design for a self-shielded biplanar coil assembly with a miniaturized structure, utilizing the target field method (TFM). Our approach involves setting different interplane spacings between each pair of planar coils to achieve high uniformity in all three axes. To further improve the field homogeneity and self-shielding effect, the particle swarm optimization with linearly decreasing inertia weight (LDW-PSO) is introduced into TFM to design self-shielded coils. This method reduces dependence on the position distribution of target points. Our results indicate that the maximum absolute value of field relative inhomogeneity errors of Bx and Bz are 14.4% and 10.0%, respectively. Furthermore, the maximum absolute value of external relative field at 16 mm from the center is approximately 1%, meaning that the influence of crosstalk can be ignored.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Optimal Design of Self-Shielded Biplanar Coil Assembly With Miniaturized Structure
The multi-channel optically-pumped magnetometer (OPM) system can experience crosstalk between adjacent sensors owing to the magnetic field generated by the magnetic coil. To mitigate this issue, this study proposes a design for a self-shielded biplanar coil assembly with a miniaturized structure, utilizing the target field method (TFM). Our approach involves setting different interplane spacings between each pair of planar coils to achieve high uniformity in all three axes. To further improve the field homogeneity and self-shielding effect, the particle swarm optimization with linearly decreasing inertia weight (LDW-PSO) is introduced into TFM to design self-shielded coils. This method reduces dependence on the position distribution of target points. Our results indicate that the maximum absolute value of field relative inhomogeneity errors of Bx and Bz are 14.4% and 10.0%, respectively. Furthermore, the maximum absolute value of external relative field at 16 mm from the center is approximately 1%, meaning that the influence of crosstalk can be ignored.
- Open Access
- 27 September 2023
- Published by Elsevier in Results in Physics
- Vol. 53
Design of gradient coils based on the target field method in a high-permeability shield considering sidewall apertures
- 27 September 2023
- Published by Elsevier in Results in Physics
- Vol. 53
Open AccessDesign of gradient coils based on the target field method in a high-permeability shield considering sidewall apertures
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 18099-18107
Triaxial Coils In Situ Calibration Method Based on Measuring the Alternating Magnetic Field-Induced Dynamic Response of the SERF Magnetometer
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in-situ calibration, we firstly studied the transient atomic dynamics of a dual beam SERF atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction decay (FID) curves by alternately applying square wave signals to the x -, y - and z -axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x-y , y-z , and z-x , respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (16) , 18099-18107
Triaxial Coils In Situ Calibration Method Based on Measuring the Alternating Magnetic Field-Induced Dynamic Response of the SERF Magnetometer
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in-situ calibration, we firstly studied the transient atomic dynamics of a dual beam SERF atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction decay (FID) curves by alternately applying square wave signals to the x -, y - and z -axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x-y , y-z , and z-x , respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.
- Open Access
Analysis and Measurement of Differential-Mode Magnetic Noise in Mn-Zn Soft Ferrite Shield for Ultra-Sensitive Sensors
The magnetic noise generated by the ferrite magnetic shield affects the performance of ultra-sensitive atomic sensors. Differential measurement can effectively suppress the influence of common-mode (CM) magnetic noise, but the limit of suppression capability is not clear at present. In this paper, a finite element analysis model using power loss to calculate differential-mode (DM) magnetic noise under a ferrite magnetic shield is proposed. The experimental results confirm the feasibility of the model. An ultrahigh-sensitive magnetometer was built, the single channel magnetic noise measured and the differential-mode (DM) magnetic noise are 0.70 fT/Hz1/2 and 0.10 fT/Hz1/2 @30 Hz. The DM magnetic noise calculated by the proposed model is less than 5% different from the actual measured value. To effectively reduce DM magnetic noise, we analyze and optimize the structure parameters of the shield on the DM magnetic noise. When the outer diameter is fixed, the model is used to analyze the influence of the ratio of ferrite magnetic shielding thickness to outer diameter, the ratio of length to outer diameter, and the air gap between magnetic annuli on DM magnetic noise. The results show that the axial DM magnetic noise and radial DM magnetic noise reach the optimal values when the thickness to outer diameter ratio is 0.08 and 0.1. The ratio of length to outer diameter is negatively correlated with DM magnetic noise, and the air gap (0.1–1 mm) is independent of DM magnetic noise. The axial DM magnetic noise is less than that of radial DM magnetic noise. These results are useful for suppressing magnetic noise and breaking through the sensitivity of the magnetometer.
Open AccessAnalysis and Measurement of Differential-Mode Magnetic Noise in Mn-Zn Soft Ferrite Shield for Ultra-Sensitive Sensors
The magnetic noise generated by the ferrite magnetic shield affects the performance of ultra-sensitive atomic sensors. Differential measurement can effectively suppress the influence of common-mode (CM) magnetic noise, but the limit of suppression capability is not clear at present. In this paper, a finite element analysis model using power loss to calculate differential-mode (DM) magnetic noise under a ferrite magnetic shield is proposed. The experimental results confirm the feasibility of the model. An ultrahigh-sensitive magnetometer was built, the single channel magnetic noise measured and the differential-mode (DM) magnetic noise are 0.70 fT/Hz1/2 and 0.10 fT/Hz1/2 @30 Hz. The DM magnetic noise calculated by the proposed model is less than 5% different from the actual measured value. To effectively reduce DM magnetic noise, we analyze and optimize the structure parameters of the shield on the DM magnetic noise. When the outer diameter is fixed, the model is used to analyze the influence of the ratio of ferrite magnetic shielding thickness to outer diameter, the ratio of length to outer diameter, and the air gap between magnetic annuli on DM magnetic noise. The results show that the axial DM magnetic noise and radial DM magnetic noise reach the optimal values when the thickness to outer diameter ratio is 0.08 and 0.1. The ratio of length to outer diameter is negatively correlated with DM magnetic noise, and the air gap (0.1–1 mm) is independent of DM magnetic noise. The axial DM magnetic noise is less than that of radial DM magnetic noise. These results are useful for suppressing magnetic noise and breaking through the sensitivity of the magnetometer.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5596-5605
Octagonal Three-Dimensional Shim Coils Structure and Design in Atomic Sensors for Magnetic Field Detection
Triaxial uniform coils installed in the magnetically shielded cylinder are essential components of an atomic magnetometer to achieve ultra-sensitive measurements and are used to compensate for the ambient magnetic remanence in the magnetometer’s operating area. This paper proposes the new three-dimensional octagonal coils configured with a two-pair octagonal coil and two double-nested octagonal coils, which differs from the conventional square or circular shim coils. The spatially homogeneous distribution of the magnetic field of the three-dimensional shim coils based on this configuration is simulated and evaluated, and then the fabrication and experimental tests are completed. The theoretical calculation results show that the magnetic field uniformity of the z-direction two-pair octagonal coil is improved by about one order of magnitude compared with that of the conventional coil such as the Lee-Whiting coil and the Rubens coil. The magnetic field uniformity of x-direction or y-direction double nested octagonal coil is promoted by about two orders of magnitude compared with that of saddle coil. The experimental magnetic field distribution is consistent with the theoretical value. This configuration can reduce the outer diameter of the coil under the premise of meeting the requirement of setting the magnetic field uniform zone, and it is easier to install than the cylindrical coil assemblies.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (6) , 5596-5605
Octagonal Three-Dimensional Shim Coils Structure and Design in Atomic Sensors for Magnetic Field Detection
Triaxial uniform coils installed in the magnetically shielded cylinder are essential components of an atomic magnetometer to achieve ultra-sensitive measurements and are used to compensate for the ambient magnetic remanence in the magnetometer’s operating area. This paper proposes the new three-dimensional octagonal coils configured with a two-pair octagonal coil and two double-nested octagonal coils, which differs from the conventional square or circular shim coils. The spatially homogeneous distribution of the magnetic field of the three-dimensional shim coils based on this configuration is simulated and evaluated, and then the fabrication and experimental tests are completed. The theoretical calculation results show that the magnetic field uniformity of the z-direction two-pair octagonal coil is improved by about one order of magnitude compared with that of the conventional coil such as the Lee-Whiting coil and the Rubens coil. The magnetic field uniformity of x-direction or y-direction double nested octagonal coil is promoted by about two orders of magnitude compared with that of saddle coil. The experimental magnetic field distribution is consistent with the theoretical value. This configuration can reduce the outer diameter of the coil under the premise of meeting the requirement of setting the magnetic field uniform zone, and it is easier to install than the cylindrical coil assemblies.