Frederik Wauters
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Frederik Wauters has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Knecht
Paul Scherrer Institute
5 shared publications - Klaus Kirch
Institute for Particle Physics and Astrophysics, ETH Zurich, Zurich, Switzerland
5 shared publications - Paul Indelicato
Laboratoire Kastler Brossel
3 shared publications - Randolf Pohl
Max-Planck-Institut für Quantenoptik, Garching, Germany
3 shared publications - Stergiani Marina Vogiatzi
NUM, Paul Scherrer Institut, Villigen PSI, Switzerland
3 shared publications - Thomas Elias Cocolios
KU Leuven
3 shared publications
Latest Publications
- Open Access
- 14 September 2026
- Published by Springer Nature in Nature Physics
- Vol. 22 (11) , 1748-1753
Generation of a high-intensity, superthermal muonium beam for gravity and laser spectroscopy experiments
The universality of free fall, a cornerstone of Einstein’s theory of gravity, has so far only been tested with neutral composite states of first-generation standard model particles, such as atoms, neutrons and antihydrogen. Muonium, the bound state of a positively charged anti-muon and an electron, offers the possibility to probe gravity in the absence of the strong interaction with second-generation standard model particles. However, the short muon lifetime and the existing diffuse thermal muonium sources rendered such measurements unfeasible. Here we report the generation of a high-brightness muonium beam, which we extract from a thin layer of superfluid helium. The mean longitudinal velocity and narrow spread of the velocity distribution indicate a superthermal beam, and yields are similar to the highest-intensity diffuse sources. This beam is expected to enable muonium interferometry and a per-cent-level measurement of its gravitational acceleration. In addition, its unprecedented brightness opens the way to sub-kilohertz 1S–2S spectroscopy, enabling the precise determination of the muon mass and stringent tests of bound-state quantum electrodynamics.
- 14 September 2026
- Published by Springer Nature in Nature Physics
- Vol. 22 (11) , 1748-1753
Open AccessGeneration of a high-intensity, superthermal muonium beam for gravity and laser spectroscopy experiments
The universality of free fall, a cornerstone of Einstein’s theory of gravity, has so far only been tested with neutral composite states of first-generation standard model particles, such as atoms, neutrons and antihydrogen. Muonium, the bound state of a positively charged anti-muon and an electron, offers the possibility to probe gravity in the absence of the strong interaction with second-generation standard model particles. However, the short muon lifetime and the existing diffuse thermal muonium sources rendered such measurements unfeasible. Here we report the generation of a high-brightness muonium beam, which we extract from a thin layer of superfluid helium. The mean longitudinal velocity and narrow spread of the velocity distribution indicate a superthermal beam, and yields are similar to the highest-intensity diffuse sources. This beam is expected to enable muonium interferometry and a per-cent-level measurement of its gravitational acceleration. In addition, its unprecedented brightness opens the way to sub-kilohertz 1S–2S spectroscopy, enabling the precise determination of the muon mass and stringent tests of bound-state quantum electrodynamics.
- Open Access
- 6 June 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (6) , 1-29
A compact frozen-spin trap for the search for the electric dipole moment of the muon
Electric dipole moments (EDM) of fundamental particles inherently violate time-reversal (T) and the combined charge-conjugation and parity symmetry (CP). We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, $$E\approx {165\,\mathrm{MV/m}}$$ , experienced in the rest frame of the muon with a momentum of about $${23\,\mathrm{MeV/}}c$$ when it passes through a solenoidal magnetic field of $$|\vec {B}|={2.5\,\textrm{T}}$$ . In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is $$\sigma (d)\le {4E-21\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ . In a subsequent phase, Phase II, we propose to improve the sensitivity to $$\sigma (d)\le {6E-23\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ using a dedicated instrument installed on a different beamline that produces muons of momentum 125 $$\textrm{MeV}\!/\!{ c}$$ .- 6 June 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (6) , 1-29
Open AccessA compact frozen-spin trap for the search for the electric dipole moment of the muon
Electric dipole moments (EDM) of fundamental particles inherently violate time-reversal (T) and the combined charge-conjugation and parity symmetry (CP). We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, $$E\approx {165\,\mathrm{MV/m}}$$ , experienced in the rest frame of the muon with a momentum of about $${23\,\mathrm{MeV/}}c$$ when it passes through a solenoidal magnetic field of $$|\vec {B}|={2.5\,\textrm{T}}$$ . In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is $$\sigma (d)\le {4E-21\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ . In a subsequent phase, Phase II, we propose to improve the sensitivity to $$\sigma (d)\le {6E-23\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ using a dedicated instrument installed on a different beamline that produces muons of momentum 125 $$\textrm{MeV}\!/\!{ c}$$ . - Open Access
Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.Open AccessTowards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays. - Open Access
Towards Precision Muonic X-ray Measurements of Charge Radii of Light Nuclei
We, the QUARTET Collaboration, propose an experiment to measure the nuclear charge radii of light elements with up to 20 times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, ) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.Open AccessTowards Precision Muonic X-ray Measurements of Charge Radii of Light Nuclei
We, the QUARTET Collaboration, propose an experiment to measure the nuclear charge radii of light elements with up to 20 times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, ) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays. - 28 October 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (18) , 182502
-Nuclear-Recoil Correlation from Decay in a Laser TrapWe report the first precise measurement of a -recoil correlation from a radioactive noble gas () confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.- 28 October 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (18) , 182502
-Nuclear-Recoil Correlation from Decay in a Laser TrapWe report the first precise measurement of a -recoil correlation from a radioactive noble gas () confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.- Open Access
- 28 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2541
Characterization of a Continuous Muon Source for the Non-Destructive and Depth-Selective Elemental Composition Analysis by Muon Induced X- and Gamma-rays
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g., elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
- 28 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2541
Open AccessCharacterization of a Continuous Muon Source for the Non-Destructive and Depth-Selective Elemental Composition Analysis by Muon Induced X- and Gamma-rays
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g., elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
- Open Access
- 9 September 2019
- Published by Sissa Medialab Srl
- Vol. 341, 140
The search for Lepton-Flavour Violation with the Mu3e Experiment
The Mu3e experiment aims to measure the lepton-flavour violating decay $\mu^+ \rightarrow e^+ e^+ e^-$ at the $2 \cdot 10^{-16}$ level, initially with a single event sensitivity of $2 \cdot 10^{-15}$ for the phase I detector described here. A DC muon beam at the Paul Scherrer Institute (PSI) of 10$^8 \mu^+$/s will be stopped inside a Si pixel tracker constructed from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented with timing detectors. An excellent momentum resolution is achieved by tracking the low momentum positrons (electrons) inside a 1T magnetic field. With multiple scattering being the limiting factor on the momentum resolution, each detector layer has a thickness of approximately 0.1\% of a radiation length. Currently, all detector prototypes perform according to the required specifications, and their design is being finalized. The collaboration is working to integrate all detector systems and install the experiment at PSI.- 9 September 2019
- Published by Sissa Medialab Srl
- Vol. 341, 140
Open AccessThe search for Lepton-Flavour Violation with the Mu3e Experiment
The Mu3e experiment aims to measure the lepton-flavour violating decay $\mu^+ \rightarrow e^+ e^+ e^-$ at the $2 \cdot 10^{-16}$ level, initially with a single event sensitivity of $2 \cdot 10^{-15}$ for the phase I detector described here. A DC muon beam at the Paul Scherrer Institute (PSI) of 10$^8 \mu^+$/s will be stopped inside a Si pixel tracker constructed from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented with timing detectors. An excellent momentum resolution is achieved by tracking the low momentum positrons (electrons) inside a 1T magnetic field. With multiple scattering being the limiting factor on the momentum resolution, each detector layer has a thickness of approximately 0.1\% of a radiation length. Currently, all detector prototypes perform according to the required specifications, and their design is being finalized. The collaboration is working to integrate all detector systems and install the experiment at PSI. - Open Access
- 1 July 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (07) , P07029
Design and operation of a cryogenic charge-integrating preamplifier for the MuSun experiment
- 1 July 2014
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 9 (07) , P07029
Open AccessDesign and operation of a cryogenic charge-integrating preamplifier for the MuSun experiment