EAEhsan Altayef

Ehsan Altayef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ehsan Altayef has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection and Classification of Lamination Faults in a 15 kVA Three-Phase Transformer Core Using SVM, KNN and DT Algorithms

    by Ehsan Altayef, Fateh Anayi, M. Packianather, Youcef Benmahamed, Omar Kherif

    This paper deals with the detection and classification of two types of lamination faults (i.e., edge burr and lamination insulation faults) in a three-phase transformer core. Previous experimental results are exploited, which are obtained by employing a 15 kVA transformer under healthy and faulty conditions. Different test conditions are considered such as the flux density, number of the affected laminations and fault location. Indeed, the current signals are used where four features (Average, Fundamental, THD and STD) are extracted. Elaborating A total of 328 samples, these features are utilized as input vectors to train and test classification models based on SVM, KNN and DT algorithms. Based on the selected features, the results confirm that the transformer current can be used for the detection of lamination faults. An accuracy rate of more than 84% is obtained using three different classifiers. Such findings provide a promising step toward fault detection and classification in electrical transformers, helping to prevent the system and avoid other related issues such as the increase of power loss and temperature.


  • Open Access

    On the Effects of Lamination Artificial Faults in a 15 kVA Three-Phase Transformer Core

    by Ehsan Altayef, Fatih Anayi, Michael S. Packianather, Omar Kherif

    Cutting and punching of the steel used in power transformer core may cause edge burrs. This, along with the degradation of the lamination insulation, can lead to interlaminar short circuits. Analysing these faults helps understanding their effect on the transformer reliability and performance. In this light, the actual paper aims to experimentally simulate and analyse both faults using a 15 kVA three phase power transformer. Effects produced from both selected faults are experimentally investigated in this paper where different scenarios are considered such as the area of the affected regions and the number of short-circuited laminations. Various flux densities are considered ranging from 0.5 to 1.8 T. Of interest, the current at no load is recorded and the test is repeated for any given scenario. The obtained results are presented and discussed to study the effect of each fault on the transformer performance. Overall, the transformer current increases with the number of short-circuits between laminations for both faults. This increase is related to the flux density, which is dependent and sensitive to the short circuit location. Such findings represent a good indication of the severity of short circuits relative to their position in the transformer core, and can be exploited to discuss the power losses in the transformer core.