Jiying Shen
Research Subjects
Jiying Shen has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jin Yang
Department of Ophthalmology, Eye, Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People’s Republic of China
5 shared publications - Lei Cai
Department of Ophthalmology, Eye, Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
3 shared publications Baoxian Zhuo
Department of Ophthalmology and the Eye Institute, Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
2 shared publications- Dongmei Ma
Department of Ophthalmology and the Eye Institute, Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
2 shared publications Limei Zhang
From the Department of Ophthalmology, Shanghai Heping Eye Hospital (J.S., S.N., L.Z., H.G.), Shanghai, China
2 shared publications- Limei Zhang
Department of Ophthalmology, Shanghai Heping Eye Hospital, Shanghai, China
2 shared publications
Latest Publications
- 16 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (12) , 1203-1209
Rotational stability of three toric intraocular lens platforms after cataract surgery: prospective multicenter randomized trial
Purpose: To compare the postoperative rotational stability of 3 toric intraocular lens (IOL) platforms and identify platform-specific biometric factors associated with rotation. Setting: 3 eye centers in China. Design: Prospective multicenter randomized controlled trial. Methods: A total of 256 eyes of 172 cataract patients with regular corneal astigmatism that completed 3 months of follow-up after phacoemulsification with implantation of TECNIS Toric II, Clareon Toric, or AT TORBI 709M were included. Participants were randomly assigned to one of the 3 toric IOL platforms. Baseline rotational alignment was defined at the end of surgery and compared with retroillumination images obtained at 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. Results: Absolute rotation changed most prominently within the first week and then progressively stabilized. Rotational stability was reached earlier in the ZCU and CNW0T groups, which plateaued at 1 week, whereas the AT TORBI 709M approached stability between 2 weeks and 1 month. Throughout follow-up, the AT TORBI 709M showed greater rotation than the CNW0T, whereas the ZCU demonstrated the least rotation. Significant rotation of ≥10 degrees occurred in 1.2%, 2.4%, and 12.2% of eyes, respectively. White-to-white distance was associated with greater rotation in the CNW0T and AT TORBI 709M groups, lens thickness was additionally associated with greater rotation in the AT TORBI 709M group, and no biometric factor reached significance in the ZCU group. Conclusions: Hydrophobic C-loop toric IOLs showed better early rotational stability than the hydrophilic plate-haptic toric IOL. Biometric correlates of rotation differed across platforms, supporting individualized toric IOL selection and postoperative monitoring.
- 16 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (12) , 1203-1209
Rotational stability of three toric intraocular lens platforms after cataract surgery: prospective multicenter randomized trial
Purpose: To compare the postoperative rotational stability of 3 toric intraocular lens (IOL) platforms and identify platform-specific biometric factors associated with rotation. Setting: 3 eye centers in China. Design: Prospective multicenter randomized controlled trial. Methods: A total of 256 eyes of 172 cataract patients with regular corneal astigmatism that completed 3 months of follow-up after phacoemulsification with implantation of TECNIS Toric II, Clareon Toric, or AT TORBI 709M were included. Participants were randomly assigned to one of the 3 toric IOL platforms. Baseline rotational alignment was defined at the end of surgery and compared with retroillumination images obtained at 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. Results: Absolute rotation changed most prominently within the first week and then progressively stabilized. Rotational stability was reached earlier in the ZCU and CNW0T groups, which plateaued at 1 week, whereas the AT TORBI 709M approached stability between 2 weeks and 1 month. Throughout follow-up, the AT TORBI 709M showed greater rotation than the CNW0T, whereas the ZCU demonstrated the least rotation. Significant rotation of ≥10 degrees occurred in 1.2%, 2.4%, and 12.2% of eyes, respectively. White-to-white distance was associated with greater rotation in the CNW0T and AT TORBI 709M groups, lens thickness was additionally associated with greater rotation in the AT TORBI 709M group, and no biometric factor reached significance in the ZCU group. Conclusions: Hydrophobic C-loop toric IOLs showed better early rotational stability than the hydrophilic plate-haptic toric IOL. Biometric correlates of rotation differed across platforms, supporting individualized toric IOL selection and postoperative monitoring.
- Open Access
- 28 November 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1214714
Effect of astigmatism on visual outcomes after multifocal intraocular lens implantation: a systematic review and meta-analysis
Purpose: To investigate the effects of postoperative astigmatism on the visual outcomes following presbyopia-correcting surgery with multifocal intraocular lens implantation.Methods: A comprehensive literature search was conducted using PubMed, Embase, and Web of Science for articles published until January 2023. Additionally, we included retrospective case series and prospective comparative studies. The combined mean difference (MD) with 95% confidence intervals (CI) and odds ratio (OR) with 95% CI were used to express continuous and categorical outcomes, respectively. All statistical analyses were performed using Review Manager (version 5.4.1).Results: We included nine eligible studies that analyzed 3,088 eyes. The proportion of eyes with useful postoperative visual acuity (logMAR ≤ 0.20) and residual astigmatism significantly differed with respect to the magnitude of astigmatism and presence/absence of blurred vision (p < 0.001 for both). Additionally, the mean uncorrected distance visual acuity (MD, 0.14; 95% CI, 0.06 to 0.21; p = 0.0003) and uncorrected intermediate visual acuity (MD, 0.07; 95% CI, 0.00 to 0.13; p = 0.04), but not the uncorrected near visual acuity (MD, 0.02; 95%CI-0.01 to 0.05; p = 0.17), significantly differed according to the magnitude of astigmatism.Conclusion: Astigmatism, even at low levels (≥ 0.5D), has a significant effect on visual outcomes, especially on UDVA and UIVA, following multifocal intraocular lens implantation. Accurate preoperative and postoperative evaluation of astigmatism is important.
- 28 November 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1214714
Open AccessEffect of astigmatism on visual outcomes after multifocal intraocular lens implantation: a systematic review and meta-analysis
Purpose: To investigate the effects of postoperative astigmatism on the visual outcomes following presbyopia-correcting surgery with multifocal intraocular lens implantation.Methods: A comprehensive literature search was conducted using PubMed, Embase, and Web of Science for articles published until January 2023. Additionally, we included retrospective case series and prospective comparative studies. The combined mean difference (MD) with 95% confidence intervals (CI) and odds ratio (OR) with 95% CI were used to express continuous and categorical outcomes, respectively. All statistical analyses were performed using Review Manager (version 5.4.1).Results: We included nine eligible studies that analyzed 3,088 eyes. The proportion of eyes with useful postoperative visual acuity (logMAR ≤ 0.20) and residual astigmatism significantly differed with respect to the magnitude of astigmatism and presence/absence of blurred vision (p < 0.001 for both). Additionally, the mean uncorrected distance visual acuity (MD, 0.14; 95% CI, 0.06 to 0.21; p = 0.0003) and uncorrected intermediate visual acuity (MD, 0.07; 95% CI, 0.00 to 0.13; p = 0.04), but not the uncorrected near visual acuity (MD, 0.02; 95%CI-0.01 to 0.05; p = 0.17), significantly differed according to the magnitude of astigmatism.Conclusion: Astigmatism, even at low levels (≥ 0.5D), has a significant effect on visual outcomes, especially on UDVA and UIVA, following multifocal intraocular lens implantation. Accurate preoperative and postoperative evaluation of astigmatism is important.
- Open Access
- 22 March 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 254, 1-10
Binocular Visual Outcomes Comparison of Two Trifocal Intraocular Lenses in High-Myopic Cataract Patients: A 1-Year Multicenter Study
- 22 March 2023
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 254, 1-10
Open AccessBinocular Visual Outcomes Comparison of Two Trifocal Intraocular Lenses in High-Myopic Cataract Patients: A 1-Year Multicenter Study
- 1 March 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (3) , 253-258
Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors
Purpose: To investigate the rotational stability of plate-haptic toric intraocular lenses (IOLs) during 3-month follow-up. Setting: Eye and ENT Hospital of Fudan University, Shanghai, China. Design: Prospective observational study. Methods: Patients with cataracts implanted with AT TORBI 709M toric IOLs were enrolled and followed at 1 hour, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was applied to investigate the time course of absolute IOL rotation change. The 2-week overall IOL rotation was analyzed in the age, sex, axial length (AL), lens thickness (LT), preexisting astigmatism, and white-to-white subgroups. Results: A total of 328 eyes of 258 patients were included. The rotation from the end of surgery to 1 hour and 1 day to 3 days was significantly smaller compared with the rotation from 1 hour to 1 day but more than that at other time intervals in the overall group. 2 weeks postoperatively, the mean uncorrected distance visual acuity and remaining positive cylinder were 0.19 ± 0.22 logMAR and 0.60 ± 0.44 diopters, respectively. Significant between-group differences in 2-week overall rotation were found in the age, AL, and LT subgroups. Conclusions: Maximum rotation occurred within 1 hour to 1 day postoperatively, and the first 3 days postoperatively was a high-risk period for the plate-haptic toric IOL rotation. Surgeons should make the patients aware of this.
- 1 March 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (3) , 253-258
Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors
Purpose: To investigate the rotational stability of plate-haptic toric intraocular lenses (IOLs) during 3-month follow-up. Setting: Eye and ENT Hospital of Fudan University, Shanghai, China. Design: Prospective observational study. Methods: Patients with cataracts implanted with AT TORBI 709M toric IOLs were enrolled and followed at 1 hour, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was applied to investigate the time course of absolute IOL rotation change. The 2-week overall IOL rotation was analyzed in the age, sex, axial length (AL), lens thickness (LT), preexisting astigmatism, and white-to-white subgroups. Results: A total of 328 eyes of 258 patients were included. The rotation from the end of surgery to 1 hour and 1 day to 3 days was significantly smaller compared with the rotation from 1 hour to 1 day but more than that at other time intervals in the overall group. 2 weeks postoperatively, the mean uncorrected distance visual acuity and remaining positive cylinder were 0.19 ± 0.22 logMAR and 0.60 ± 0.44 diopters, respectively. Significant between-group differences in 2-week overall rotation were found in the age, AL, and LT subgroups. Conclusions: Maximum rotation occurred within 1 hour to 1 day postoperatively, and the first 3 days postoperatively was a high-risk period for the plate-haptic toric IOL rotation. Surgeons should make the patients aware of this.
- Open Access
- 28 February 2022
- Published by Wiley in Journal of Ophthalmology
- Vol. 2022, 1-9
Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
Purpose. To investigate the benefits of multifocal lens in patients with high myopic cataract and compare the clinical effects between AT LISA tri 839MP and MPlus LS-313 MF30 intraocular lenses (IOLs) in high myopic eyes. Methods. This retrospective cohort study analyzed 60 eyes with axial length >26 mm in 40 patients. Thirty eyes were implanted with MF30, and the remaining 30 eyes were implanted with 839MP. Postoperative uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), defocus curve, modulation transfer function (MTF) curve, Strehl ratio (SR), and complications were compared between the two groups. Results. All vision outcomes were significantly improved in both groups ( ). There was no significant between-group difference in UDVA at 1 and 3 months postoperatively ( ). However, UIVA and UNVA were significantly better in the 839MP group ( ). The VF-14 score, especially for near vision quality, was significantly higher in the MF30 group (2.2 ± 0.9 vs. 0.8 ± 0.7; ). The SR of both groups significantly increased postoperatively ( ). All the 3-month MTF curve values (MTF 10 total, MTF 10 internal, MTF 30 total, and MTF 30 internal) were significantly better in the 839MP group ( ). Meanwhile, all the high-order aberration values (coma, spherical aberration, and trefoil) were significantly greater in the MF30 group ( ). Conclusion. Multifocal IOL implantation achieves good quality of distance, intermediate, and near vision in patients with high myopia, improving their quality of life. Both 839MP and MF30 IOLs can provide good distance vision, but 839MP performs better in near and intermediate vision. However, for some patients with an extra-long optic axis, MF30 may be a good choice because of its wider range of degrees.
- 28 February 2022
- Published by Wiley in Journal of Ophthalmology
- Vol. 2022, 1-9
Open AccessComparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
Purpose. To investigate the benefits of multifocal lens in patients with high myopic cataract and compare the clinical effects between AT LISA tri 839MP and MPlus LS-313 MF30 intraocular lenses (IOLs) in high myopic eyes. Methods. This retrospective cohort study analyzed 60 eyes with axial length >26 mm in 40 patients. Thirty eyes were implanted with MF30, and the remaining 30 eyes were implanted with 839MP. Postoperative uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), defocus curve, modulation transfer function (MTF) curve, Strehl ratio (SR), and complications were compared between the two groups. Results. All vision outcomes were significantly improved in both groups ( ). There was no significant between-group difference in UDVA at 1 and 3 months postoperatively ( ). However, UIVA and UNVA were significantly better in the 839MP group ( ). The VF-14 score, especially for near vision quality, was significantly higher in the MF30 group (2.2 ± 0.9 vs. 0.8 ± 0.7; ). The SR of both groups significantly increased postoperatively ( ). All the 3-month MTF curve values (MTF 10 total, MTF 10 internal, MTF 30 total, and MTF 30 internal) were significantly better in the 839MP group ( ). Meanwhile, all the high-order aberration values (coma, spherical aberration, and trefoil) were significantly greater in the MF30 group ( ). Conclusion. Multifocal IOL implantation achieves good quality of distance, intermediate, and near vision in patients with high myopia, improving their quality of life. Both 839MP and MF30 IOLs can provide good distance vision, but 839MP performs better in near and intermediate vision. However, for some patients with an extra-long optic axis, MF30 may be a good choice because of its wider range of degrees.