Siddarth Arumugam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Siddarth Arumugam has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Samuel K. Sia
Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
7 shared publications Samuel K. Sia
Columbia University School of Engineering, New York, USA
5 shared publicationsCody Lentz
Department of Psychology, Temple University, Philadelphia, USA
4 shared publicationsCurtis Dolezal
HIV Center for Clinical and Behavioral Studies at the New York State Psychiatric Institute and Columbia University, New York, USA
4 shared publications- Iván C. Balán
Florida State University, Tallahassee, FL, USA
3 shared publications Samiksha Nayak
Department of Biomedical Engineering, Columbia University, New York, New York, USA
3 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10 (1) , e86407
Pre-Exposure Prophylaxis Adherence and HIV Self-Testing App Among Women in the South Bronx: 12-Month Usability, Acceptability, and Feasibility Study
Background: HIV pre-exposure prophylaxis (PrEP) is underused by cis- and transgender women despite a significant HIV burden. Smartphone technologies are promising tools to support HIV prevention but have yet to be assessed in women. Objective: We conducted a 12-month feasibility study to assess the use and acceptability of a mobile phone app, SmartPrEP, designed to support PrEP adherence and HIV self- and partner-testing among women living in an area of elevated HIV burden in New York City. Methods: Nonpregnant adult cisgender and transgender women who met US PrEP eligibility criteria and were PrEP naïve, reported PrEP use for 4 HIV risk behaviors in the past 6 months, with 58% (23/40) reporting anal or vaginal sex with more than 1 partner. Over the course of the study, although 8 participants withdrew early, and 14 were lost to follow-up, there were 2 pregnancies and 1 HIV seroconversion. PrEP adherence was low, with 80% (32/40) recording 3 doses per week compared to 20% (8/40). In total, 4 participants conducted HIV self- or partner-testing using SmartPrEP during study follow-up. App acceptability assessed at month 12 was moderate to high (median score 3.71 of max 5, IQR 3.47‐4.16). Conclusions: Despite consistently rating the app as acceptable and receiving quarterly HIV testing and counseling, most participants did not achieve optimal PrEP adherence, demonstrating the limitations of this mobile health app among women at elevated risk of HIV. Active navigation and strategies to address gaps in risk perception among women will remain critical, as new, long-acting formulations of PrEP become available.
- 2 June 2026
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10 (1) , e86407
Open AccessPre-Exposure Prophylaxis Adherence and HIV Self-Testing App Among Women in the South Bronx: 12-Month Usability, Acceptability, and Feasibility Study
Background: HIV pre-exposure prophylaxis (PrEP) is underused by cis- and transgender women despite a significant HIV burden. Smartphone technologies are promising tools to support HIV prevention but have yet to be assessed in women. Objective: We conducted a 12-month feasibility study to assess the use and acceptability of a mobile phone app, SmartPrEP, designed to support PrEP adherence and HIV self- and partner-testing among women living in an area of elevated HIV burden in New York City. Methods: Nonpregnant adult cisgender and transgender women who met US PrEP eligibility criteria and were PrEP naïve, reported PrEP use for 4 HIV risk behaviors in the past 6 months, with 58% (23/40) reporting anal or vaginal sex with more than 1 partner. Over the course of the study, although 8 participants withdrew early, and 14 were lost to follow-up, there were 2 pregnancies and 1 HIV seroconversion. PrEP adherence was low, with 80% (32/40) recording 3 doses per week compared to 20% (8/40). In total, 4 participants conducted HIV self- or partner-testing using SmartPrEP during study follow-up. App acceptability assessed at month 12 was moderate to high (median score 3.71 of max 5, IQR 3.47‐4.16). Conclusions: Despite consistently rating the app as acceptable and receiving quarterly HIV testing and counseling, most participants did not achieve optimal PrEP adherence, demonstrating the limitations of this mobile health app among women at elevated risk of HIV. Active navigation and strategies to address gaps in risk perception among women will remain critical, as new, long-acting formulations of PrEP become available.
- 15 May 2023
- Published by Springer Nature in Archives of Sexual Behavior
- Vol. 52 (5) , 1961-1968
Transgender Women’s Experiences Using SMARTtest, a Smartphone Application to Facilitate Self- and Partner-HIV/Syphilis Testing Using the INSTI Multiplex
We present experiences of transgender women (TW) who have sex with men with SMARTtest, a smartphone app to accompany the INSTI Multiplex®, a one-minute, dual blood-based HIV/syphilis rapid test. TW participants (N = 11) received 10 INSTI Multiplex® tests to take home for self- and/or partner-testing and installed the SMARTtest app on their phones. The SMARTtest app aimed to support INSTI Multiplex users in correctly performing the test, interpreting the results, and connecting with care following a positive HIV or syphilis screening. After 3 months, users completed in-depth interviews on their experiences. A total of 9 TW used SMARTtest with partners. App feedback was positive, but refining is necessary. Specifically, TW reported that SMARTtest is easy to use and convenient; instructions on how to use the INSTI Multiplex presented on the app were helpful to complete procedures correctly; the most frequently used feature on SMARTtest was the information on clinics that offered confirmatory testing; and participants and their partners were not concerned about app privacy but reported that this could change if INSTI Multiplex detected an HIV-positive result. Further, participants provided recommendations on how to improve SMARTtest, and changes were mostly related to features, content, functionality, navigation, and overall “look” of the app. SMARTtest is promising to facilitate INSTI Multiplex® use in TW. User feedback should be integrated in future versions.
- 15 May 2023
- Published by Springer Nature in Archives of Sexual Behavior
- Vol. 52 (5) , 1961-1968
Transgender Women’s Experiences Using SMARTtest, a Smartphone Application to Facilitate Self- and Partner-HIV/Syphilis Testing Using the INSTI Multiplex
We present experiences of transgender women (TW) who have sex with men with SMARTtest, a smartphone app to accompany the INSTI Multiplex®, a one-minute, dual blood-based HIV/syphilis rapid test. TW participants (N = 11) received 10 INSTI Multiplex® tests to take home for self- and/or partner-testing and installed the SMARTtest app on their phones. The SMARTtest app aimed to support INSTI Multiplex users in correctly performing the test, interpreting the results, and connecting with care following a positive HIV or syphilis screening. After 3 months, users completed in-depth interviews on their experiences. A total of 9 TW used SMARTtest with partners. App feedback was positive, but refining is necessary. Specifically, TW reported that SMARTtest is easy to use and convenient; instructions on how to use the INSTI Multiplex presented on the app were helpful to complete procedures correctly; the most frequently used feature on SMARTtest was the information on clinics that offered confirmatory testing; and participants and their partners were not concerned about app privacy but reported that this could change if INSTI Multiplex detected an HIV-positive result. Further, participants provided recommendations on how to improve SMARTtest, and changes were mostly related to features, content, functionality, navigation, and overall “look” of the app. SMARTtest is promising to facilitate INSTI Multiplex® use in TW. User feedback should be integrated in future versions.
- Open Access
- 22 March 2022
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 7 (6)
Snapshots of nascent RNA reveal cell- and stimulus-specific responses to acute kidney injury
The current strategy to detect acute injury of kidney tubular cells relies on changes in serum levels of creatinine. Yet serum creatinine (sCr) is a marker of both functional and pathological processes and does not adequately assay tubular injury. In addition, sCr may require days to reach diagnostic thresholds, yet tubular cells respond with programs of damage and repair within minutes or hours. To detect acute responses to clinically relevant stimuli, we created mice expressing Rosa26-floxed-stop uracil phosphoribosyltransferase ( Uprt ) and inoculated 4-thiouracil (4-TU) to tag nascent RNA at selected time points. Cre-driven 4-TU–tagged RNA was isolated from intact kidneys and demonstrated that volume depletion and ischemia induced different genetic programs in collecting ducts and intercalated cells. Even lineage-related cell types expressed different genes in response to the 2 stressors. TU tagging also demonstrated the transient nature of the responses. Because we placed Uprt in the ubiquitously active Rosa26 locus, nascent RNAs from many cell types can be tagged in vivo and their roles interrogated under various conditions. In short, 4-TU labeling identifies stimulus-specific, cell-specific, and time-dependent acute responses that are otherwise difficult to detect with other technologies and are entirely obscured when sCr is the sole metric of kidney damage.
- 22 March 2022
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 7 (6)
Open AccessSnapshots of nascent RNA reveal cell- and stimulus-specific responses to acute kidney injury
The current strategy to detect acute injury of kidney tubular cells relies on changes in serum levels of creatinine. Yet serum creatinine (sCr) is a marker of both functional and pathological processes and does not adequately assay tubular injury. In addition, sCr may require days to reach diagnostic thresholds, yet tubular cells respond with programs of damage and repair within minutes or hours. To detect acute responses to clinically relevant stimuli, we created mice expressing Rosa26-floxed-stop uracil phosphoribosyltransferase ( Uprt ) and inoculated 4-thiouracil (4-TU) to tag nascent RNA at selected time points. Cre-driven 4-TU–tagged RNA was isolated from intact kidneys and demonstrated that volume depletion and ischemia induced different genetic programs in collecting ducts and intercalated cells. Even lineage-related cell types expressed different genes in response to the 2 stressors. TU tagging also demonstrated the transient nature of the responses. Because we placed Uprt in the ubiquitously active Rosa26 locus, nascent RNAs from many cell types can be tagged in vivo and their roles interrogated under various conditions. In short, 4-TU labeling identifies stimulus-specific, cell-specific, and time-dependent acute responses that are otherwise difficult to detect with other technologies and are entirely obscured when sCr is the sole metric of kidney damage.
- 25 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (23) , 4517-4548
Point-of-care diagnostics: recent developments in a pandemic age
This article reviews the rapid and unprecedented development, scaleup and deployment of POC devices in response to the COVID-19 pandemic and its implications for the future of diagnostics and digital health.
- 25 November 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (23) , 4517-4548
Point-of-care diagnostics: recent developments in a pandemic age
This article reviews the rapid and unprecedented development, scaleup and deployment of POC devices in response to the COVID-19 pandemic and its implications for the future of diagnostics and digital health.
- Open Access
SafeSwab, a sample collection and dispensing device for near-patient testing
Background The COVID-19 pandemic has accelerated the pace of innovation around virtual care visits and testing technology. Here we present the SafeSwab (Safe Health Systems, Los Angeles, CA), an integrated, universal sample collection and dispensing device that is designed to minimize user error and enable rapid testing in a point of care or self-testing format. Methods The SafeSwab was used with the Safe Health Systems HealthCheck digital health application to enable self-testing by patients using lateral flow tests for SARS-CoV-2 antigen or for antibodies against SARS-CoV-2. Results Patients (n=74) using the SafeSwab produced a valid rapid test result in 96% of attempts, and 96% of patients felt confident that they had collected a good sample. The Safe HealthCheck app has an integrated image analysis algorithm, AutoAdapt LFA, that interprets a picture of a rapid test result, and the algorithm interpreted the result correctly 100% of the time. Conclusion The SafeSwab was found to be versatile and easy to use for both self-collected nasal sampling as well as fingerstick blood sampling. The use of Safe Health Systems HealthCheck app allows an integrated solution for patient instruction and test interpretation
Open AccessSafeSwab, a sample collection and dispensing device for near-patient testing
Background The COVID-19 pandemic has accelerated the pace of innovation around virtual care visits and testing technology. Here we present the SafeSwab (Safe Health Systems, Los Angeles, CA), an integrated, universal sample collection and dispensing device that is designed to minimize user error and enable rapid testing in a point of care or self-testing format. Methods The SafeSwab was used with the Safe Health Systems HealthCheck digital health application to enable self-testing by patients using lateral flow tests for SARS-CoV-2 antigen or for antibodies against SARS-CoV-2. Results Patients (n=74) using the SafeSwab produced a valid rapid test result in 96% of attempts, and 96% of patients felt confident that they had collected a good sample. The Safe HealthCheck app has an integrated image analysis algorithm, AutoAdapt LFA, that interprets a picture of a rapid test result, and the algorithm interpreted the result correctly 100% of the time. Conclusion The SafeSwab was found to be versatile and easy to use for both self-collected nasal sampling as well as fingerstick blood sampling. The use of Safe Health Systems HealthCheck app allows an integrated solution for patient instruction and test interpretation
- Open Access
Adaptable Automated Interpretation of Rapid Diagnostic Tests Using Few-Shot Learning
Point-of-care lateral-flow assays (LFAs) are becomingly increasingly prevalent for diagnosing individual patient disease status and surveying population disease prevalence in a timely, scalable, and cost-effective manner, but a central challenge is to assure correct assay operation and results interpretation as the assays are manually performed in decentralized settings. A smartphone-based software can automate interpretation of an LFA kit, but such algorithms typically require a very large number of images of assays tested with validated specimens, which is challenging to collect for different assay kits, especially for those released during a pandemic. Here, we present an approach – AutoAdapt LFA – that uses few-shot learning, an approach used in other applications such as computer vision and robotics, for accurate and automated interpretation of LFA kits that requires a small number of validated images for training. The approach consists of three components: extraction of membrane and zone areas from an image of the LFA kit, a self-supervised encoder that employs a feature extractor trained with edge-filtered patterns, and few-shot adaptation that enables generalization to new kits using limited validated images. From a base model pre-trained on a commercial LFA kit, we demonstrated the ability of adapted models to interpret results from five new COVID-19 LFA kits (three detecting antigens for diagnosing active infection, and two detecting antibodies for diagnosing past infection). Specifically, using just 10 to 20 images of each new kit, we achieved accuracies of 99% to 100% for each kit. The server-hosted algorithm has an execution time of approximately 4 seconds, which can potentially enable quality assurance and linkage to care for users operating new LFAs in decentralized settings.
Open AccessAdaptable Automated Interpretation of Rapid Diagnostic Tests Using Few-Shot Learning
Point-of-care lateral-flow assays (LFAs) are becomingly increasingly prevalent for diagnosing individual patient disease status and surveying population disease prevalence in a timely, scalable, and cost-effective manner, but a central challenge is to assure correct assay operation and results interpretation as the assays are manually performed in decentralized settings. A smartphone-based software can automate interpretation of an LFA kit, but such algorithms typically require a very large number of images of assays tested with validated specimens, which is challenging to collect for different assay kits, especially for those released during a pandemic. Here, we present an approach – AutoAdapt LFA – that uses few-shot learning, an approach used in other applications such as computer vision and robotics, for accurate and automated interpretation of LFA kits that requires a small number of validated images for training. The approach consists of three components: extraction of membrane and zone areas from an image of the LFA kit, a self-supervised encoder that employs a feature extractor trained with edge-filtered patterns, and few-shot adaptation that enables generalization to new kits using limited validated images. From a base model pre-trained on a commercial LFA kit, we demonstrated the ability of adapted models to interpret results from five new COVID-19 LFA kits (three detecting antigens for diagnosing active infection, and two detecting antibodies for diagnosing past infection). Specifically, using just 10 to 20 images of each new kit, we achieved accuracies of 99% to 100% for each kit. The server-hosted algorithm has an execution time of approximately 4 seconds, which can potentially enable quality assurance and linkage to care for users operating new LFAs in decentralized settings.
- 26 May 2021
- Published by Springer Nature in AIDS and Behavior
- Vol. 26 (1) , 35-46
Acceptability and Use of a Dual HIV/Syphilis Rapid Test and Accompanying Smartphone App to Facilitate Self- and Partner-Testing Among Cisgender Men and Transgender Women Who Have Sex with Men
At home self- and partner-testing may reduce HIV and syphilis transmission by detecting undiagnosed infections. Forty-eight cisgender men and transgender women who men who have sex with men were given ten INSTI Multiplex kits and downloaded the SMARTtest app to facilitate self- and partner testing over the next three months. Thirty-seven (77%) participants self-tested using the INSTI (mean = 3.7 times, SD = 3.9); 26 (54%) tested partners (mean = 1.6 times, SD = 2.2). Participants liked the test for its ease of use, quick results, and dual HIV/syphilis testing but its blood-based nature hindered use with partners. Participants with reactive syphilis results always attributed them to a past infection and these results presented a challenge to testing with partners and the ability to accurately assess risk of infection. Most participants stated they would use the INSTI for self-testing (100%) and for partner-testing (89%). Acceptability of the SMARTtest app was high for functionality (M = 4.16 of max 5, SD = 0.85) and helpfulness (M = 6.12 of max 7, SD = 1.09). Participants often used the app as needed, eschewing its use if they felt comfortable conducting the test and interpreting its results. Seventy-eight percent would recommend the app to a friend. Availability of the INSTI Multiplex as a self-test with the accompanying SMARTtest app might increase frequency of HIV and syphilis testing, allowing for earlier detection of infection and reduced transmission.
- 26 May 2021
- Published by Springer Nature in AIDS and Behavior
- Vol. 26 (1) , 35-46
Acceptability and Use of a Dual HIV/Syphilis Rapid Test and Accompanying Smartphone App to Facilitate Self- and Partner-Testing Among Cisgender Men and Transgender Women Who Have Sex with Men
At home self- and partner-testing may reduce HIV and syphilis transmission by detecting undiagnosed infections. Forty-eight cisgender men and transgender women who men who have sex with men were given ten INSTI Multiplex kits and downloaded the SMARTtest app to facilitate self- and partner testing over the next three months. Thirty-seven (77%) participants self-tested using the INSTI (mean = 3.7 times, SD = 3.9); 26 (54%) tested partners (mean = 1.6 times, SD = 2.2). Participants liked the test for its ease of use, quick results, and dual HIV/syphilis testing but its blood-based nature hindered use with partners. Participants with reactive syphilis results always attributed them to a past infection and these results presented a challenge to testing with partners and the ability to accurately assess risk of infection. Most participants stated they would use the INSTI for self-testing (100%) and for partner-testing (89%). Acceptability of the SMARTtest app was high for functionality (M = 4.16 of max 5, SD = 0.85) and helpfulness (M = 6.12 of max 7, SD = 1.09). Participants often used the app as needed, eschewing its use if they felt comfortable conducting the test and interpreting its results. Seventy-eight percent would recommend the app to a friend. Availability of the INSTI Multiplex as a self-test with the accompanying SMARTtest app might increase frequency of HIV and syphilis testing, allowing for earlier detection of infection and reduced transmission.
- Open Access
- 1 November 2020
- Published by Elsevier in Kidney International Reports
- Vol. 5 (11) , 1982-1992
Rule Out Acute Kidney Injury in the Emergency Department With a Urinary Dipstick
- 1 November 2020
- Published by Elsevier in Kidney International Reports
- Vol. 5 (11) , 1982-1992
Open AccessRule Out Acute Kidney Injury in the Emergency Department With a Urinary Dipstick
- 1 December 2019
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 57 (12)
A Multiplexed Serologic Test for Diagnosis of Lyme Disease for Point-of-Care Use
Single multiplexed assays could replace the standard 2-tiered (STT) algorithm recommended for the laboratory diagnosis of Lyme disease if they perform with a specificity and a sensitivity superior or equal to those of the STT algorithm. We used human serum rigorously characterized to be sera from patients with acute- and convalescent-phase early Lyme disease, Lyme arthritis, and posttreatment Lyme disease syndrome, as well as the necessary controls (n = 241 samples), to select the best of 12 Borrelia burgdorferi proteins to improve our microfluidic assay (mChip-Ld). We then evaluated its serodiagnostic performance in comparison to that of a first-tier enzyme immunoassay and the STT algorithm. We observed that more antigens became positive as Lyme disease progressed from early to late stages. We selected three antigens (3Ag) to include in the mChip-Ld: VlsE and a proprietary synthetic 33-mer peptide (PepVF) to capture sensitivity in all disease stages and OspC for early Lyme disease. With the specificity set at 95%, the sensitivity of the mChip-Ld with 3Ag ranged from 80% (95% confidence interval [CI], 56% to 94%) and 85% (95% CI, 74% to 96%) for two panels of serum from patients with early Lyme disease and was 100% (95% CI, 83% to 100%) for serum from patients with Lyme arthritis; the STT algorithm detected early Lyme disease in the same two panels of serum from patients with early Lyme disease with a sensitivity of 48.5% and 75% and Lyme arthritis in serum from patients with Lyme arthritis with a sensitivity of 100%, and the specificity was 97.5% to 100%. The mChip-Ld platform outperformed the STT algorithm according to sensitivity. These results open the door for the development of a single, rapid, multiplexed diagnostic test for point-of-care use that can be designed to identify the Lyme disease stage.
- 1 December 2019
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 57 (12)
A Multiplexed Serologic Test for Diagnosis of Lyme Disease for Point-of-Care Use
Single multiplexed assays could replace the standard 2-tiered (STT) algorithm recommended for the laboratory diagnosis of Lyme disease if they perform with a specificity and a sensitivity superior or equal to those of the STT algorithm. We used human serum rigorously characterized to be sera from patients with acute- and convalescent-phase early Lyme disease, Lyme arthritis, and posttreatment Lyme disease syndrome, as well as the necessary controls (n = 241 samples), to select the best of 12 Borrelia burgdorferi proteins to improve our microfluidic assay (mChip-Ld). We then evaluated its serodiagnostic performance in comparison to that of a first-tier enzyme immunoassay and the STT algorithm. We observed that more antigens became positive as Lyme disease progressed from early to late stages. We selected three antigens (3Ag) to include in the mChip-Ld: VlsE and a proprietary synthetic 33-mer peptide (PepVF) to capture sensitivity in all disease stages and OspC for early Lyme disease. With the specificity set at 95%, the sensitivity of the mChip-Ld with 3Ag ranged from 80% (95% confidence interval [CI], 56% to 94%) and 85% (95% CI, 74% to 96%) for two panels of serum from patients with early Lyme disease and was 100% (95% CI, 83% to 100%) for serum from patients with Lyme arthritis; the STT algorithm detected early Lyme disease in the same two panels of serum from patients with early Lyme disease with a sensitivity of 48.5% and 75% and Lyme arthritis in serum from patients with Lyme arthritis with a sensitivity of 100%, and the specificity was 97.5% to 100%. The mChip-Ld platform outperformed the STT algorithm according to sensitivity. These results open the door for the development of a single, rapid, multiplexed diagnostic test for point-of-care use that can be designed to identify the Lyme disease stage.
- 20 November 2019
- Published by Wiley in Advanced Materials Technologies
- Vol. 5 (3) , 1900720
Biosensors for Personal Mobile Health: A System Architecture Perspective
Advances in mobile biosensors, integrating developments in materials science and instrumentation, are fueling an expansion in health data being collected and analyzed in decentralized settings. For example, semiconductor‐based sensors are enabling measurement of vital signs, and microfluidic‐based sensors are enabling measurement of biochemical markers. As biosensors for mobile health are becoming increasingly paired with smart devices, it can become critical for researchers to design biosensors—with appropriate functionalities and specifications—to work seamlessly with accompanying connected hardware and software. Here, recent research in biosensors, as well as current mobile health devices in use is described and classified into four distinct system architectures that take into account the biosensing and data processing functions required in personal mobile health devices. The path forward for integrating biosensors into smartphone‐based mobile health devices is also discussed.
- 20 November 2019
- Published by Wiley in Advanced Materials Technologies
- Vol. 5 (3) , 1900720
Biosensors for Personal Mobile Health: A System Architecture Perspective
Advances in mobile biosensors, integrating developments in materials science and instrumentation, are fueling an expansion in health data being collected and analyzed in decentralized settings. For example, semiconductor‐based sensors are enabling measurement of vital signs, and microfluidic‐based sensors are enabling measurement of biochemical markers. As biosensors for mobile health are becoming increasingly paired with smart devices, it can become critical for researchers to design biosensors—with appropriate functionalities and specifications—to work seamlessly with accompanying connected hardware and software. Here, recent research in biosensors, as well as current mobile health devices in use is described and classified into four distinct system architectures that take into account the biosensing and data processing functions required in personal mobile health devices. The path forward for integrating biosensors into smartphone‐based mobile health devices is also discussed.