CMCorantin Maurin

Corantin Maurin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Corantin Maurin has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Gilles Thuret

    Ophthalmology Department, University Hospital, Saint-Etienne, France

    7 shared publications
  • Zhiguo He

    Laboratory of Biology, Engineering and Imaging for Ophthalmology (BiiO), Faculty of Medicine, Jean Monnet University, Saint-Etienne, France

    7 shared publications
  • Philippe Gain

    BiiO Laboratory - health faculty, Université Jean Monnet Saint-Etienne, Saint-Priest-en-Jarez, France

    6 shared publications
  • Inès Aouimeur

    Laboratory for Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health & Innovation Campus, Jean Monnet University, Saint-Etienne, France

    4 shared publications
  • Louise Coulomb

    Laboratory for Biology, Engineering, and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health & Innovation Campus, Jean Monnet University, Saint-Etienne, France

    4 shared publications
  • Anaick Moisan

    Cell Therapy Unit, Auvergne Rhône Alpes French Blood Center, Saint- Ismier, France

    3 shared publications

Latest Publications

  • Three-dimensional topography of Descemet’s membrane in Fuchs endothelial corneal dystrophy using laser scanning confocal microscopy and white-light interferometry

    by Corantin Maurin, Sylvain Poinard, Gauthier Travers, Zhiguo He, Fanny Decoeur, Etienne Gontier, Georgia Karpathiou, Philippe Gain, Gilles Thuret

    Aim: To evaluate the potential of a three-dimensional microscope combining laser scanning confocal imaging and white-light interferometry for quantitative topographic characterisation of Descemet’s membrane (DM) in Fuchs endothelial corneal dystrophy (FECD). Methods: Descemet’s membranes were collected from 38 FECD patients undergoing endothelial keratoplasty and four healthy donors. After flat-mounting on glass slide and drying, specimens were analysed using the VK-X3000 system (KEYENCE). Entire samples were reconstructed by image stitching at low magnification (×10) in white-light interferometry mode (0.01 nm axial resolution). Higher magnifications (×20 to ×150) in confocal mode (12 nm axial resolution) enabled detailed structural analysis. Three-dimensional height maps were generated to calculate standardised surface roughness parameters. Guttae and other DM features were classified according to spatial organisation and elevation profiles. Results: White-light interferometry enabled full-field mapping of whole 8 mm diameter DMs with nanometric vertical resolution (~2 hours/sample). Surface roughness (Sa) was higher in FECD than in controls (median±IQR: 0.571±0.259 µm vs 0.239±0.161 µm; p=0.0018). In FECD, three zones were identified: centre (guttae buried in the posterior fibrillar layer; Sa 0.442±0.112 µm), paracentre (large uncovered guttae; Sa 0.562±0.170 µm; p=0.0423) and outer zone (no confluent guttae; Sa 0.261±0.143 µm; p<0.0001). Confocal three-dimensional (3D) imaging revealed radial striae, embossments and furrows in the DM, confluent central guttae and fused or buried structures. Conclusions: Combining white-light interferometry and confocal microscopy enables label-free, high-resolution surface characterisation of DM in FECD, providing quantitative metrics to compare histological subtypes and supporting the predominance of radial structural organisation.

  • Open Access

    Three-dimensional topography of Descemet′s membrane in Fuchs endothelial corneal dystrophy using laser scanning confocal microscopy and white-light interferometry

    by Corantin Maurin, Sylvain Poinard, Gauthier Travers, Etienne Gontier, Georgia Karpathiou, Fanny Decoeur, Zhiguo He, Philippe Gain, Gilles Thuret

    Aim: To evaluate the potential of a three-dimensional microscope combining Laser scanning confocal imaging and white-light interferometry for quantitative topographic characterisation of Descemet′s membrane (DM) in Fuchs endothelial corneal dystrophy (FECD). Methods: Descemet′s membranes were collected from 38 FECD patients undergoing endothelial keratoplasty and 4 healthy donors. After flat-mounting on glass slide and drying, specimens were analysed using the VK-X3000 system (KEYENCE). Entire samples were reconstructed by image stitching at low magnification (×10) in white-light interferometry mode (0.01nm axial resolution). Higher magnifications (×20-×150) in confocal mode (12nm axial resolution) enabled detailed structural analysis. Three-dimensional height maps were generated to calculate standardised surface roughness parameters. Guttae and other DM features were classified according to spatial organisation and elevation profiles. Results: White-light interferometry enabled full-field mapping of whole 8mm diameter DMs with nanometric vertical resolution (~2 hours/sample). Surface roughness (Sa) was higher in FECD than in controls (median±IQR: 0.571±0.259 μm vs 0.239±0.161 μm ; p = 0.0018). In FECD, three zones were identified: central (guttae buried in the posterior fibrillar layer; Sa 0.442 ± 0.112 μm), paracentral (large uncovered guttae; Sa 0.562±0.170 μm ; p = 0.0423), and outer zone (no confluent guttae; Sa 0.261±0.143 μm ; p < 0.0001). Confocal 3D imaging revealed radial striae, embossments and furrows in the DM, confluent central guttae, and fused or buried structures. Conclusions: Combining white-light interferometry and confocal microscopy enables label-free, high-resolution surface characterisation of DM in FECD, providing quantitative metrics to compare histological subtypes and supporting the predominance of radial structural organisation.

  • Open Access

    Investigating the role of molecular coating in human corneal endothelial cell primary culture using artificial intelligence-driven image analysis

    by Gauthier Travers, Louise Coulomb, Inès Aouimeur, Zhiguo He, Guillaume Bonnet, Edouard Ollier, Yann Gavet, Anaick Moisan, Philippe Gain, Gilles Thuret, et al.

    The monolayer of approximately 300,000 human corneal endothelial cells (hCECs) on the posterior surface of the cornea is essential to maintain transparency but is non-self-regenerative. Corneal blindness can currently only be treated by corneal transplantation, hindered by a global donor shortage, highlighting the need for developing tissue and/or cell therapy. The mass production of these advanced therapy medicinal products requires obtaining high-yield, high-quality endothelial cell cultures characterized by hexagonal shape, low size variability, and high endothelial cell density (ECD). Among the usual critical quality attributes which combine the expression of differentiation markers, ECD and cell morphological parameters, the latter are not optimally measured in vitro by conventional image analysis which poorly recognizes adherent cultured cells. We developed a high-performance automated segmentation using Cellpose algorithm and an original analysis method, improving the calculation of classical morphological parameters (coefficient of variation of cell area and hexagonality) and introducing new parameters specific to hCECs culture in vitro. Considering the importance of the extracellular matrix in vivo, and the panel of molecules available for coating cell culture plastics, we used these new tools to perform a comprehensive comparison of 13 molecules (laminins and collagens). We demonstrated their ability to discriminate subtle differences between cultures.


  • Open Access

    Tissue engineered endothelial keratoplasty with controlled endothelial cell density: proof of concept and paving the way for super TEEKs

    by Inès Aouimeur, Louise Parveau, Sofiane Fraine, Zhiguo He, Guillaume Bonnet, Tomy Sagnial, Gauthier Travers, Sédao Xxx, Cyril Mauclair, Anaick Moisan, et al.

    Over the past 20 years, endothelial keratoplasty procedures have revolutionized the treatment of corneal endothelial disorders. These conditions have now become the leading indication for corneal transplantation in Western countries and account for half of all donor cornea usage. Despite their undeniable success, the global shortage of donor tissues and major disparities between nations justify the development of alternatives to donor grafts. Cell therapy using injections of suspended endothelial cells has proven effective, and tissue-engineered endothelial keratoplasty (TEEK) comprising a membrane coated with cultured endothelial cells is under development to better mimic the native endothelial graft. Our team utilizes a femtosecond-laser-cut lens capsule disc as a bioengineering scaffold, taking advantage of this novel tissue’s biocompatibility, transparency, curvature, and availability. In the present study, we provide proof of concept, in 12 TEEKs, that it is possible to control the final endothelial cell density (ECD) by varying the seeding density per mm 2 . Cell characterization was performed through morphometric analysis of the endothelial mosaic stained with anti-NCAM (a lateral membrane marker used as a differentiation marker), using the CellPose artificial intelligence algorithm specifically trained for in vitro endothelium segmentation. Five criteria related to pleomorphism, polymorphism, and elongation were combined into a single endothelial quality score. The median cell viability at 28 days of culture, assessed by Hoechst 33342 and Calcein-AM staining, reached 98% (range: 83–99%). The median viable ECD (number of live cells per surface unit) in the highest-density group was 3,245 cells/mm 2 (range: 2,778–3,753), paving the way for the bioengineering of supra-physiological TEEKs, or super TEEKs. Impact statement: The process of manufacturing tissue-engineered endothelial keratoplasty (TEEK) allows for the control of endothelial cell density (DCE) and, in particular, the creation of super TEEKs, meaning grafts with supra-physiological DCE that are more likely to better withstand the challenges of surgery and have a prolonged lifespan in recipients.

  • Open Access

    Investigating The Role Of Molecular Coating in Human Corneal Endothelial Cell Primary Culture using Artificial Intelligence-driven image analysis

    by Gauthier Travers, Louise Coulomb, Inès Aouimeur, Zhiguo He, Guillaume Bonnet, Edouard Ollier, Yann Gavet, Anaick Moisan, Philippe Gain, Gilles Thuret, et al.

    The monolayer of approximately 300,000 human corneal endothelial cells (hCECs) on the posterior surface of the cornea is essential to maintain transparency but is non-self-regenerative. Corneal blindness can currently only be treated by corneal transplantation, hindered by a global donor shortage, highlighting the need for developing tissue and/or cell therapy. The mass production of these advanced therapy medicinal products requires obtaining high-yield, high-quality endothelial cell culture characterized by hexagonal shape, low size variability, and high endothelial cell density (ECD). Among the usual critical quality attributes which combine the expression of differentiation markers, ECD and cell morphology parameters, the latter are not optimally measured in vitro by conventional image analysis which poorly recognize adherent cultured cells. We developed a high-performance automated segmentation using Cellpose algorithm and an original analysis method, improving calculation of classical morphological parameters (coefficient of variation of cell area and hexagonality) and introducing new parameters specific to hCECs culture in vitro . Considering the importance of the extracellular matrix in vivo , and the panel of molecules available for coating cell culture plastics, we used these new tools to perform a comprehensive comparison of 13 molecules (laminins and collagens). We demonstrated their ability to discriminate subtle differences between cultures.


  • Open Access

    Femtosecond Laser Cutting of Human Crystalline Lens Capsule and Decellularization for Corneal Endothelial Bioengineering

    by Olfa Ben Moussa, Louise Parveau, Inès Aouimeur, Grégory Egaud, Corantin Maurin, Sofiane Fraine, Sébastien Urbaniak, Chantal Perrache, Zhiguo He, Sedao Xxx, et al.

    The bioengineering of corneal endothelial grafts consists of seeding in vitro cultured corneal endothelial cells onto a thin, transparent, biocompatible, and sufficiently robust carrier which can withstand surgical manipulations. This is one of the most realistic alternatives to donor corneas, which are in chronic global shortage. The anterior capsule of the crystalline lens has already been identified as one of the best possible carriers, but its challenging manual preparation has limited its use. In this study, we describe a femtosecond laser cutting process of the anterior capsule of whole lenses in order to obtain capsule discs of 8 mm diameter, similar to conventional endothelial grafts. Circular marks made on the periphery of the disc indicate its orientation. Immersion in water for 3 days is sufficient to completely remove the lens epithelial cells and to enable the seeding of corneal endothelial cells, which remain viable after 27 days of culture. Therefore, this method provides a transparent, decellularized disc ready to form viable tissue engineered endothelial grafts.


  • Open Access

    Investigating the Role of TGF-β Signaling Pathways in Human Corneal Endothelial Cell Primary Culture

    by Inès Aouimeur, Tomy Sagnial, Louise Coulomb, Corantin Maurin, Justin Thomas, Pierre Forestier, Sandrine Ninotta, Chantal Perrache, Fabien Forest, Philippe Gain, et al.

    Corneal endothelial diseases are the leading cause of corneal transplantation. The global shortage of donor corneas has resulted in the investigation of alternative methods, such as cell therapy and tissue-engineered endothelial keratoplasty (TEEK), using primary cultures of human corneal endothelial cells (hCECs). The main challenge is optimizing the hCEC culture process to increase the endothelial cell density (ECD) and overall yield while preventing endothelial–mesenchymal transition (EndMT). Fetal bovine serum (FBS) is necessary for hCEC expansion but contains TGF-βs, which have been shown to be detrimental to hCECs. Therefore, we investigated various TGF-β signaling pathways using inhibitors to improve hCEC culture. Initially, we confirmed that TGF-β1, 2, and 3 induced EndMT on confluent hCECs without FBS. Using this TGF-β-induced EndMT model, we validated NCAM as a reliable biomarker to assess EndMT. We then demonstrated that, in a culture medium containing 8% FBS for hCEC expansion, TGF-β1 and 3, but not 2, significantly reduced the ECD and caused EndMT. TGF-β receptor inhibition had an anti-EndMT effect. Inhibition of the ROCK pathway, notably that of the P38 MAPK pathway, increased the ECD, while inhibition of the ERK pathway decreased the ECD. In conclusion, the presence of TGF-β1 and 3 in 8% FBS leads to a reduction in ECD and induces EndMT. The use of SB431542 or LY2109761 may prevent EndMT, while Y27632 or Ripasudil, and SB203580 or SB202190, can increase the ECD.


  • Open Access

    Exploration of the ocular surface infection by SARS-CoV-2 and implications for corneal donation: An ex vivo study

    by Corantin Maurin, Zhiguo He, Marielle Mentek, Paul Verhoeven, Sylvie Pillet, Thomas Bourlet, Françoise Rogues, Jean Loup Pugniet, Thierry Peyragrosse, Marion Barallon, et al.

    Background: The risk of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) transmission through corneal graft is an ongoing debate and leads to strict restrictions in corneas procurement, leading to a major decrease in eye banking activity. The aims of this study are to specifically assess the capacity of human cornea to be infected by SARS-CoV-2 and promote its replication ex vivo, and to evaluate the real-life risk of corneal contamination by detecting SARS-CoV-2 RNA in corneas retrieved in donors diagnosed with Coronavirus Disease 2019 (COVID-19) and nonaffected donors. Methods and findings: To assess the capacity of human cornea to be infected by SARS-CoV-2, the expression pattern of SARS-CoV-2 receptor angiotensin-converting enzyme 2 (ACE-2) and activators TMPRSS2 and Cathepsins B and L in ocular surface tissues from nonaffected donors was explored by immunohistochemistry (n = 10 corneas, 78 ± 11 years, 40% female) and qPCR (n = 5 corneas, 80 ± 12 years, 40% female). Additionally, 5 freshly excised corneas (80 ± 12 years, 40% female) were infected ex vivo with highly concentrated SARS-CoV-2 solution (106 median tissue culture infectious dose (TCID50)/mL). Viral RNA was extracted from tissues and culture media and quantified by reverse transcription quantitative PCR (RT-qPCR) (viral RNA copies) 30 minutes (H0) and 24 hours (H24) after infection. To assess the risk of corneal contamination by SARS-CoV-2, viral RNA was tested by RT-qPCR (Ct value) in both corneas and organ culture media from 14 donors diagnosed with COVID-19 (74 ± 10 years, 29% female) and 26 healthy donors (79 ± 13 years, 57% female), and in organ culture media only from 133 consecutive nonaffected donors from 2 eye banks (73 ± 13 years, 29% female). The expression of receptor and activators was variable among samples at both protein and mRNA level. Based on immunohistochemistry findings, ACE-2 was localized mainly in the most superficial epithelial cells of peripheral cornea, limbus, and conjunctiva, whereas TMPRSS2 was mostly expressed in all layers of bulbar conjunctiva. A significant increase in total and positive strands of IP4 RNA sequence (RdRp viral gene) was observed from 30 minutes to 24 hours postinfection in central cornea (1.1 × 108 [95% CI: 6.4 × 107 to 2.4 × 108] to 3.0 × 109 [1.4 × 109 to 5.3 × 109], p = 0.0039 and 2.2 × 107 [1.4 × 107 to 3.6 × 107] to 5.1 × 107 [2.9 × 107 to 7.5 × 107], p = 0.0117, respectively) and in corneoscleral rim (4.5 × 109 [2.7 × 109 to 9.6 × 109] to 3.9 × 1010 [2.6 × 1010 to 4.4 × 1010], p = 0.0039 and 3.1 × 108 [1.2 × 108 to 5.3 × 108] to 7.8 × 108 [3.9 × 108 to 9.9 × 108], p = 0.0391, respectively). Viral RNA copies in ex vivo corneas were highly variable from one donor to another. Finally, viral RNA was detected in 3 out of 28 corneas (11%) from donors diagnosed with COVID-19. All samples from the 159 nonaffected donors were negative for SARS-CoV-2 RNA. The main limitation of this study relates to the limited sample size, due to limited access to donors diagnosed with COVID-19 and concomitant decrease in the procurement corneas from nonaffected donors. Conclusions: In this study, we observed the expression of SARS-CoV-2 receptors and activators at the human ocular surface and a variable increase in viral RNA copies 24 hours after experimental infection of freshly excised human corneas. We also found viral RNA only in a very limited percentage of donors with positive nasopharyngeal PCR. The low rate of positivity in donors diagnosed with COVID-19 calls into question the utility of donor selection algorithms. Trial registration: Agence de la Biomédecine, PFS-20-011 https://www.agence-biomedecine.fr/.