Hongtong Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongtong Wu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bin Hu
Key Laboratory of Brain Health Intelligent Evaluation and Intervention, Ministry of Education, Beijing Institute of Technology, Beijing, China
3 shared publications - Chang Lei
Gansu Provincial Key Laboratory of Wearable Computing, School of Information Science and Engineering, Lanzhou University, Lanzhou, China
3 shared publications - Hong Peng
School of Information Science and Engineering, Lanzhou University, Lanzhou, China
3 shared publications - Xuan Zhang
Key Laboratory of Brain Health Intelligent Evaluation and Intervention, Ministry of Education, and the School of Medical Technology, Beijing Institute of Technology, Beijing, China
3 shared publications - Dixin Wang
School of Medical Technology, Beijing Institute of Technology, Beijing, China
2 shared publications Dixin Wang
School of Information Science and Engineering, Lanzhou University, Lanzhou, China
1 shared publication
Latest Publications
- 25 January 2023
- Published by Elsevier in Neuroscience
- Vol. 524, 37-51
Analysis of Altered Brain Dynamics During Episodic Recall and Detection of Generalized Anxiety Disorder
- 25 January 2023
- Published by Elsevier in Neuroscience
- Vol. 524, 37-51
Analysis of Altered Brain Dynamics During Episodic Recall and Detection of Generalized Anxiety Disorder
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (16) , 16164-16177
Driving Fatigue Monitoring via Kernel Sparse Representation Regression With GMC Penalty
Automatic monitoring technology for fatigued driving can greatly reduce traffic accidents caused by drivers due to decreased attention. The use of monitoring algorithms based on physiological signal sensors is of great significance for objective monitoring. In this paper, a novel algorithm with excellent performance and strong generalization ability, kernel sparse representation regression based on generalized minimax-concave (GMC-KSRR), is proposed to identify fatigue physiological signals. Specifically, in the proposed algorithm, the training samples of physiological features are mapped in reproducing kernel Hilbert space (RKHS) for linear separability. Then, in RKHS, the sparse coefficients of the test samples are obtained by generalized minimax-concave (GMC) penalty-based sparse representation (SR). Different from the traditional $\ell _{{1}}$ -norm, the GMC penalty we used does not underestimate the high-amplitude component of sparsity coefficients, resulting in a more accurate regression result. Finally, the regression decision is performed in the label subspace according to the obtained sparse coefficients. Meanwhile, a multimodality algorithm based on GMC-KSRR has also been proposed that weighs each modality according to quality for robust fatigue monitoring. Eventually, competitive experimental results on the well-known SEED-VIG dataset against the state-of-the-art methods demonstrate the efficacy of the proposed algorithms in identifying fatigue physiological signals, indicating its powerful application potential in driving fatigue monitoring.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (16) , 16164-16177
Driving Fatigue Monitoring via Kernel Sparse Representation Regression With GMC Penalty
Automatic monitoring technology for fatigued driving can greatly reduce traffic accidents caused by drivers due to decreased attention. The use of monitoring algorithms based on physiological signal sensors is of great significance for objective monitoring. In this paper, a novel algorithm with excellent performance and strong generalization ability, kernel sparse representation regression based on generalized minimax-concave (GMC-KSRR), is proposed to identify fatigue physiological signals. Specifically, in the proposed algorithm, the training samples of physiological features are mapped in reproducing kernel Hilbert space (RKHS) for linear separability. Then, in RKHS, the sparse coefficients of the test samples are obtained by generalized minimax-concave (GMC) penalty-based sparse representation (SR). Different from the traditional $\ell _{{1}}$ -norm, the GMC penalty we used does not underestimate the high-amplitude component of sparsity coefficients, resulting in a more accurate regression result. Finally, the regression decision is performed in the label subspace according to the obtained sparse coefficients. Meanwhile, a multimodality algorithm based on GMC-KSRR has also been proposed that weighs each modality according to quality for robust fatigue monitoring. Eventually, competitive experimental results on the well-known SEED-VIG dataset against the state-of-the-art methods demonstrate the efficacy of the proposed algorithms in identifying fatigue physiological signals, indicating its powerful application potential in driving fatigue monitoring.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Epileptic Seizure Detection in EEG Signals Using Discriminative Stein Kernel-Based Sparse Representation
The automatic seizure detection in electroencephalogram (EEG) signals is crucial for the monitoring, diagnosis, and treatment of epilepsy. In this study, an intelligent detection framework with the discriminative Stein kernel-based sparse representation (DSK-SR) is constructed to distinguish epileptic EEG signals. Specifically, in the scheme of DSK-SR, EEG samples are presented by symmetric positive definite (SPD) matrices in the form of covariance descriptors (CovDs). Taking into account the non-Euclidean geometry of the Riemannian manifold of SPD matrices, the traditional SR in Euclidean space cannot be applied in its original form on the manifold. To this end, the DSK defined on the manifold can permit us to embed the manifold into a high-dimensional reproducing kernel Hilbert space (RKHS) to perform SR. Then, test samples are sparsely coded over the training sets, and the classification decision is performed by assessing which class generates the minimal reconstructed residuals. Eventually, competitive experimental results on three widely recognized EEG datasets against the state-of-the-art methods demonstrate the efficacy of the proposed DSK-SR in identifying epileptic EEG signals, indicating its powerful application potential in the automatic seizure detection.
- 21 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-15
Epileptic Seizure Detection in EEG Signals Using Discriminative Stein Kernel-Based Sparse Representation
The automatic seizure detection in electroencephalogram (EEG) signals is crucial for the monitoring, diagnosis, and treatment of epilepsy. In this study, an intelligent detection framework with the discriminative Stein kernel-based sparse representation (DSK-SR) is constructed to distinguish epileptic EEG signals. Specifically, in the scheme of DSK-SR, EEG samples are presented by symmetric positive definite (SPD) matrices in the form of covariance descriptors (CovDs). Taking into account the non-Euclidean geometry of the Riemannian manifold of SPD matrices, the traditional SR in Euclidean space cannot be applied in its original form on the manifold. To this end, the DSK defined on the manifold can permit us to embed the manifold into a high-dimensional reproducing kernel Hilbert space (RKHS) to perform SR. Then, test samples are sparsely coded over the training sets, and the classification decision is performed by assessing which class generates the minimal reconstructed residuals. Eventually, competitive experimental results on three widely recognized EEG datasets against the state-of-the-art methods demonstrate the efficacy of the proposed DSK-SR in identifying epileptic EEG signals, indicating its powerful application potential in the automatic seizure detection.