Feng Jia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Feng Jia has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hanzhi Li
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an, China
2 shared publications - Shuang Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications - Yonghong Cheng
State Key Laboratory of Electrical Insulation and Power Equipment
2 shared publications - Yu Chen
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications Bin Guo
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publication- Changxi Li
School of Electrical Engineering Xi'an Jiaotong University, Xi'an, People's Republic of China
1 shared publication
Latest Publications
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3159-3168
The Multifactor Aging Characteristics and Aging State Assessment of Epoxy Composites for GIS
Epoxy and its composites are widely used as raw materials for the solid insulations in gas insulated switchgear (GIS) worldwide due to their excellent dielectric properties, thermal stability, corrosion resistance, and ease of processing. These insulation materials show aging phenomena under multiple stresses of electrical, thermal and vibration during GIS operation, which reduces the electrical and mechanical strength of solid insulation, and further leads to operational failures in GIS. Therefore, it is crucial to study the aging characteristics of epoxy composite under the influence of multi-aging-factor and assess their aging state. To explore the inherent characteristics of epoxy composites, this paper designs a recessed type specimen and the corresponding testing platform for multi-factor aging experiments and aging state parameter tests. The epoxy composites are aged by different combinations of electrical, thermal and vibration stresses. The dielectric parameters and partial discharge voltages are measured in selected time intervals. And the aging characteristics and aging state assessment of the epoxy composites under multiple aging factors are discussed, which has certain guiding significance for the maintenance and retirement of solid insulations in GIS.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3159-3168
The Multifactor Aging Characteristics and Aging State Assessment of Epoxy Composites for GIS
Epoxy and its composites are widely used as raw materials for the solid insulations in gas insulated switchgear (GIS) worldwide due to their excellent dielectric properties, thermal stability, corrosion resistance, and ease of processing. These insulation materials show aging phenomena under multiple stresses of electrical, thermal and vibration during GIS operation, which reduces the electrical and mechanical strength of solid insulation, and further leads to operational failures in GIS. Therefore, it is crucial to study the aging characteristics of epoxy composite under the influence of multi-aging-factor and assess their aging state. To explore the inherent characteristics of epoxy composites, this paper designs a recessed type specimen and the corresponding testing platform for multi-factor aging experiments and aging state parameter tests. The epoxy composites are aged by different combinations of electrical, thermal and vibration stresses. The dielectric parameters and partial discharge voltages are measured in selected time intervals. And the aging characteristics and aging state assessment of the epoxy composites under multiple aging factors are discussed, which has certain guiding significance for the maintenance and retirement of solid insulations in GIS.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Temperature Monitoring for 500 kV Oil-Filled Submarine Cable Based on BOTDA Distributed Optical Fiber Sensing Technology: Method and Application
The 500 kV oil-filled ac submarine cables in the networking project of China’s southern coast are large capacity, ultrahigh-voltage cross-sea submarine power cables, which are 31 km long and bundled with submarine optical cables. Temperature monitoring on submarine cables is of great significance in controlling the ampacity and ensuring operational reliability. Referring to the submarine cables’ structural characteristics and setting conditions, a temperature monitoring system is established based on the Brillouin optical time-domain analysis (BOTDA) distributed optical fiber sensing technology. The thermal circuit model IEC60287 is modified and used to calculate internal temperature distribution. Moreover, an onshore simulation experimental platform is established on the same cables as the networking project with a special sealing and joint structures designed for filling oil and adding load, proving the accuracy of the temperature monitoring system and the calculation method. Finally, one example of the on-site operation and maintenances data is presented to show the actual working condition of the temperature monitoring system.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Temperature Monitoring for 500 kV Oil-Filled Submarine Cable Based on BOTDA Distributed Optical Fiber Sensing Technology: Method and Application
The 500 kV oil-filled ac submarine cables in the networking project of China’s southern coast are large capacity, ultrahigh-voltage cross-sea submarine power cables, which are 31 km long and bundled with submarine optical cables. Temperature monitoring on submarine cables is of great significance in controlling the ampacity and ensuring operational reliability. Referring to the submarine cables’ structural characteristics and setting conditions, a temperature monitoring system is established based on the Brillouin optical time-domain analysis (BOTDA) distributed optical fiber sensing technology. The thermal circuit model IEC60287 is modified and used to calculate internal temperature distribution. Moreover, an onshore simulation experimental platform is established on the same cables as the networking project with a special sealing and joint structures designed for filling oil and adding load, proving the accuracy of the temperature monitoring system and the calculation method. Finally, one example of the on-site operation and maintenances data is presented to show the actual working condition of the temperature monitoring system.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Damage Analysis of Suspended Submarine Cable under Current Force Based on Finite Element Simulation
In this paper, 500kV AC submarine cable was taken as the object, the finite element software COMSOL was used to establish the simulation model of fluid-structure coupling, and the force of the suspended submarine cable was analyzed. The stress distribution of the lead alloy sheath of the cable in four specific directions and the location of the maximum stress value was obtained. On this basis, the relationship between the suspended length and the stress value was obtained by changing the suspended length of the submarine cable. According to the initial yield stress value of the lead alloy sheath, the reference suspended length of the preliminary damaged cable structure was given, which provides some theoretical analysis for the online monitoring of the submarine cable. The results show that when the suspended length reached 7.05 meters, the maximum stress value of the lead alloy sheath at the initial yield stress is 1.97×10 7 (N/m 2 ).
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Damage Analysis of Suspended Submarine Cable under Current Force Based on Finite Element Simulation
In this paper, 500kV AC submarine cable was taken as the object, the finite element software COMSOL was used to establish the simulation model of fluid-structure coupling, and the force of the suspended submarine cable was analyzed. The stress distribution of the lead alloy sheath of the cable in four specific directions and the location of the maximum stress value was obtained. On this basis, the relationship between the suspended length and the stress value was obtained by changing the suspended length of the submarine cable. According to the initial yield stress value of the lead alloy sheath, the reference suspended length of the preliminary damaged cable structure was given, which provides some theoretical analysis for the online monitoring of the submarine cable. The results show that when the suspended length reached 7.05 meters, the maximum stress value of the lead alloy sheath at the initial yield stress is 1.97×10 7 (N/m 2 ).
- 1 June 2015
- Published by Springer Nature in Interdisciplinary Sciences: Computational Life Sciences
- Vol. 7 (2) , 200-204
The Calculations and Simulation Testing on the Elastic Modulus of Wheat
The elastic modulus (E) of wheat is not only an important parameter in mechanical property of wheat grain, but also is one of the most important parameter for the materials in the analysis three-dimensional modeling of wheat. In this study, the relationship between load-deformation properties of the three different moisture contents wheat grains determined by TA-XT2i texturometer and pressures in simulated analyzed using a three-dimensional model of wheat was investigated. The elastic modulus was calculated by the results of the load deformation under the pressure, and verified and amended using the three-dimensional model. The results showed that the elastic modulus range for wheat was from 37 to 75 MPa, while the moisture content of wheat rose from 10 to 20 %. The difference in compressive deformation between the reality and the model was <5 %.
- 1 June 2015
- Published by Springer Nature in Interdisciplinary Sciences: Computational Life Sciences
- Vol. 7 (2) , 200-204
The Calculations and Simulation Testing on the Elastic Modulus of Wheat
The elastic modulus (E) of wheat is not only an important parameter in mechanical property of wheat grain, but also is one of the most important parameter for the materials in the analysis three-dimensional modeling of wheat. In this study, the relationship between load-deformation properties of the three different moisture contents wheat grains determined by TA-XT2i texturometer and pressures in simulated analyzed using a three-dimensional model of wheat was investigated. The elastic modulus was calculated by the results of the load deformation under the pressure, and verified and amended using the three-dimensional model. The results showed that the elastic modulus range for wheat was from 37 to 75 MPa, while the moisture content of wheat rose from 10 to 20 %. The difference in compressive deformation between the reality and the model was <5 %.