ALAng Li

Ang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ang Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A novel quality criterion for self-noise measurement of velocity-type seismometers

    by Ang Li, Hongyuan Yang, Huaizhu Zhang, Fan Zheng, Linhang Zhang, Can Liu, Ruojin Li

    Accurate measurement of seismometer self-noise is crucial for instrument performance evaluation and the development of deep exploration equipment. However, the measurement accuracy is severely compromised by external background noise, time synchronization errors, and other factors. The long-standing absence of quantitative data quality assessment methods has undermined the credibility of measurement results. This study proposes the two-path coefficient of variation (TPCV) criterion, which quantifies data quality by utilizing the practical discrepancy between two theoretically equivalent computational paths in the three-channel correlation method. Simulations using synthetic data validate the statistical relationship between the TPCV criterion and self-noise measurement errors under varying conditions of synchronization error and background noise intensity. Additionally, a unified unit conversion method for calculating acceleration noise in velocity-type seismometers and a synchronization error compensation algorithm are introduced. Field experiments with a moving-coil seismometer in an urban lawn environment, affected by strong background noise, yielded TPCV values of 29.0%–65.1% (median 37.4%), exceeding the 0.30 reference threshold. The corresponding self-noise was 205–285 n g / H z @10 Hz, indicating poor data quality. In a cave environment experiment using nodal seismometers, the pre-compensation TPCV values were 26.4%–61.0% (median 29.6%), falling within the suspicious to unreliable range, with self-noise of 5–7 n g / H z @10 Hz. After synchronization compensation, TPCV values decreased to 1.2%–11.9% (median 1.7%), and self-noise recovered to 2.6–4.7 n g / H z @10 Hz, representing a 94% improvement in TPCV. This verifies the effectiveness of the synchronization compensation algorithm and the sensitivity of the TPCV criterion to time synchronization errors. This study provides a quantitative and automated quality control tool for the three-channel correlation method, recommends reference thresholds for data quality assessment, and holds promise for promoting the establishment of a more scientific and unified standard system for seismometer self-noise measurement.

  • Open Access

    Frequency Response Extension Method of MET Vector Hydrophone Based on Dynamic Feedback Network

    by Fang Bian, Ang Li, Hongyuan Yang, Fan Zheng, Dapeng Yang, Huaizhu Zhang, Linhang Zhang, Ruojin Li

    Hydrophone is a key component of marine seismic exploration systems, divided into a scalar hydrophone and vector hydrophone. The electrochemical vector hydrophone has attracted much attention due to its high sensitivity and low-frequency detection capability. With the development of noise reduction technology, high-frequency noise has been effectively suppressed, while low-frequency noise is still difficult to control, which has become a key issue in the monitoring of underwater target radiation noise. The traditional electrochemical vector hydrophone based on the molecular electron transfer (MET) principle is limited in the working bandwidth in the low-frequency band, which affects the detection capability of low-frequency radiation signals from underwater targets. In order to solve this problem, a frequency response extension method of a MET electrochemical vector hydrophone based on dynamic feedback network is proposed. By introducing a dynamic force balance negative feedback system based on a digital signal processor (DSP), the working bandwidth of the hydrophone is extended, and the detection capability of low-frequency signals is enhanced. At the same time, the system has field adjustability and can resist the long-term system frequency characteristic drift. Experimental results show that the proposed method effectively improves the frequency response performance of the electrochemical vector hydrophone, providing a new technical solution for its application in the monitoring of low-frequency radiation noise from underwater targets.


  • Temperature Adaptation for Electrochemical Seismometers Based on Dynamic Feedback Network

    by Hongyuan Yang, Ang Li, Fan Zheng, Dapeng Yang, Huaizhu Zhang, Linhang Zhang, Fang Bian

    The electrochemical seismometers based on molecular electronic transfer (MET) exhibit significantly higher sensitivity than conventional moving-coil seismometers, offering broad application prospects in seismic exploration. However, METs are extremely sensitive to environmental temperature, with their frequency response significantly altering with temperature changes. These alterations display nonlinear characteristics across different frequency bands (such as high and low frequencies), resulting in operating bandwidth drift, which severely affects data quality. Existing temperature compensation methods are only effective in certain frequency bands, and compensating for operating bandwidth drift remains challenging, currently a hot research topic. This paper proposes the FSC-DFF adaptive temperature compensation method, which utilizes Frequency Response Self-Calibration (FSC) and a Dynamic Force Balance Feedback system (DFF) to achieve temperature compensation across the entire frequency band of MET. This method effectively compensates for the working frequency band drift and supports on-site adaptive adjustment. The temperature characteristics of MET were measured within the temperature range of -20°C to 50°C, and simulations and experiments were conducted. After compensation, the sensitivity drift was reduced to 1.6%. Compared with traditional Open-Loop Post-Processing (OLPP) and Closed-Loop Thermistor Compensation (CLTC) methods, the low-frequency cutoff frequency drift decreased from 447.2% (OLPP) and 51.4% (CLTC) to 15.1%, while the high-frequency cutoff frequency drift decreased from 89.3% (OLPP) and 85.0% (CLTC) to 3.2%. This significantly expands the application prospects of electrochemical seismic detectors in areas with severe temperature changes.


  • A Link and Energy Aware Gradient Routing Method for Seismic Node Networks

    by Jun Lin, Longxu Wang, Hongyuan Yang, Fan Zheng, Xunqian Tong, Ruyun Tian, Rongzhou Duan, Ang Li

    Seismic node is an important geological exploration equipment. The seismic node has a complex near-ground application environment. The near-ground seriously interferes with the wireless signal of the seismic node and affects its data transmission capability. This article proposes a link and energy-aware gradient routing (LEGR) method, which can effectively reduce the interference of the near-ground on the seismic node. LEGR introduces the concept of link potential energy (LPE) to represent the gradient and establishes the LPE loss model using the link quality and the remaining power. The LPE is generated by the data acquisition center (DAC) and spreads to each node with some loss which is depending on the LPE loss model during the propagation process, and finally, a gradient field about the LPE is formed. Data are transmitted along the steepest direction of the gradient to the DAC. The simulation results show that LEGR significantly reduces the impact of wireless signal strength fluctuations on the seismic node compared with other traditional routing methods. The experimental results show that LEGR is superior to the commonly used routing method for seismic nodes network in term of packets latency and packet delivery rate, improves the anti-interference ability, and enhances the wireless communication reliability for the seismic node networks.


  • A Field Self-Adjusting Method for Electrochemical Seismometer Based on Dynamic Feedback Network

    by Ang Li, Hongyuan Yang, Dapeng Yang, Jun Lin, Fan Zheng, Huaizhu Zhang, Ruyun Tian

    Based on the dynamic force feedback network, a fast self-adjusting method with field working ability is designed for the electrochemical seismometer. Dynamic feedback network provides the characteristics of adaptability in complex environments for the seismometer. And the reusage of feedback source provides a very low-cost self-testing ability without a laboratory environment or any external equipment. To implement this method, an analytical adjusting algorithm is derived. The simulation shows the adjusting adaptability for arbitrary targets and multiple electrochemical seismometers. A prototype is developed to verify the method, the prototype can be adjusted to the optimal second-order system under arbitrarily cutoff frequency between 0.5Hz and 1Hz, and the self-adjusting process finished within 10 minutes.


  • Three-Level Control of DC Side Voltage Balance of Cascaded H-Bridge APF

    by Yunliang Wang, Zichen Li, Yanjuan Wu, Zhengkun Bai, Ang Li

    The stable operation of H-bridge APF is based on the equilibrium of the DC side capacitors voltage. This thesis proposes a three-stage method for equalizing the voltage of capacitance. This control strategy significantly improves the pressure level of the APF. And in order to improve the accuracy of current output, on the basis of three layers of DC side control, the repetitive control is added. Finally, the voltage is controlled near the given magnitude. Then, the simulation results show that the three-stage method is very effective. which provides a basis for cascading APF applications to higher voltage levels.


  • Open Access

    Numerical and Experimental Study on Seakeeping Performance of a High-Speed Trimaran with T-foil in Head Waves

    by Ang Li, Yunbo Li

    The longitudinal motion characteristics of a slender trimaran equipped with and without a T-foil near the bow are investigated by experimental and numerical methods. Computational fluid dynamics ( CFD) method is used in this study. The seakeeping characteristics such as heave, pitch and vertical acceleration in head regular waves are analyzed in various wave conditions. Numerical simulations have been validated by comparisons with experimental tests. The influence of large wave amplitudes and size of T-foil on the longitudinal motion of trimaran are analyzed. The present systematic study demonstrates that the numerical results are in a reasonable agreement with the experimental data. The research implied that the longitudinal motion response values are greatly reduced with the use of T-foil.