Kara Malhotra
Research Subjects
Kara Malhotra has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alexander M. Reyzelman
California School of Podiatric Medicine Samuel Merritt University San Francisco, CA United States
4 shared publications - Chia-Ding Shih
USC Keck School of Medicine: University of Southern California Keck School of Medicine
4 shared publications - Henk Jan Scholten
Siren Care Inc, San Francisco, CA, United States
4 shared publications - Ran Ma
Siren Care Inc, San Francisco, CA, United States
4 shared publications - David G. Armstrong
Department of Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA
2 shared publications - Gregory Tovmassian
California School of Podiatric Medicine Samuel Merritt University San Francisco, CA United States
2 shared publications
Latest Publications
- Open Access
- 1 April 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (4) , e31870
An Evaluation of Real-world Smart Sock–Based Temperature Monitoring Data as a Physiological Indicator of Early Diabetic Foot Injury: Case-Control Study
Background: Lower extremity complications of diabetes represent major health care complications both in terms of cost and impact to quality of life for patients with diabetic peripheral neuropathy. Temperature monitoring has been shown in previous studies to provide a useful signal of inflammation that may indicate the early presence of a foot injury. Objective: In this study, we evaluated the temperature data for patients that presented with a diabetic foot injury while using a sock-based remote temperature monitoring device. Methods: The study abstracted data from patients who were enrolled in a remote temperature monitoring program (2020-2021) using a smart sock (Siren Care). In the study cohort, a total of 5 participants with a diabetes-related lower extremity injury during the study period were identified. In the second comparison cohort, a total of 26 patients met the criteria for monitoring by the same methods but did not present with a diabetes-related podiatric lower extremity injury during the same period. The 15-day temperature differential between 6 defined locations on each foot was the primary outcome measure among subjects who presented with a diagnosed foot injury. Paired t tests were used to compare the differences between the two groups. Results: A significant difference in temperature differential (temperature measured in °F) was observed in the group that presented with a podiatric injury over the course of evaluation versus the comparator group that did not present with a podiatric injury. The average difference from all 6 measured points was 1.4 °F between the injury group (mean 3.6, SD 3.0) and the comparator group (mean 2.2, SD 2.5, t=–71.4, df=39; P<.001). Conclusions: The results of this study suggest temperature monitoring in a sock form factor could be used to predict a developing foot injury. The continuous temperature monitoring system employed has implications for further algorithm development to enable early detection. The study was limited by a nonrandomized, observational design with limited injuries present in the study period. We look forward to further studies that will refine the predictive potential and confirm or refute the current promising data.
- 1 April 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (4) , e31870
Open AccessAn Evaluation of Real-world Smart Sock–Based Temperature Monitoring Data as a Physiological Indicator of Early Diabetic Foot Injury: Case-Control Study
Background: Lower extremity complications of diabetes represent major health care complications both in terms of cost and impact to quality of life for patients with diabetic peripheral neuropathy. Temperature monitoring has been shown in previous studies to provide a useful signal of inflammation that may indicate the early presence of a foot injury. Objective: In this study, we evaluated the temperature data for patients that presented with a diabetic foot injury while using a sock-based remote temperature monitoring device. Methods: The study abstracted data from patients who were enrolled in a remote temperature monitoring program (2020-2021) using a smart sock (Siren Care). In the study cohort, a total of 5 participants with a diabetes-related lower extremity injury during the study period were identified. In the second comparison cohort, a total of 26 patients met the criteria for monitoring by the same methods but did not present with a diabetes-related podiatric lower extremity injury during the same period. The 15-day temperature differential between 6 defined locations on each foot was the primary outcome measure among subjects who presented with a diagnosed foot injury. Paired t tests were used to compare the differences between the two groups. Results: A significant difference in temperature differential (temperature measured in °F) was observed in the group that presented with a podiatric injury over the course of evaluation versus the comparator group that did not present with a podiatric injury. The average difference from all 6 measured points was 1.4 °F between the injury group (mean 3.6, SD 3.0) and the comparator group (mean 2.2, SD 2.5, t=–71.4, df=39; P<.001). Conclusions: The results of this study suggest temperature monitoring in a sock form factor could be used to predict a developing foot injury. The continuous temperature monitoring system employed has implications for further algorithm development to enable early detection. The study was limited by a nonrandomized, observational design with limited injuries present in the study period. We look forward to further studies that will refine the predictive potential and confirm or refute the current promising data.
- Open Access
- 1 March 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (3) , e32934
Utilization of a Smart Sock for the Remote Monitoring of Patients With Peripheral Neuropathy: Cross-sectional Study of a Real-world Registry
Background: Remote patient monitoring (RPM) devices are increasingly being used in caring for patients to reduce risks of complications. Temperature monitoring specifically has been shown in previous studies to provide a useful signal of inflammation that may help prevent foot ulcers. Objective: In this cross-sectional study, we evaluated utilization data for patients who were prescribed smart socks as remote temperature monitoring devices. Methods: This study evaluated data from a patient registry from January to July 2021. The utilization data, which were collected starting from the first full month since patients were prescribed the smart socks, were evaluated along with retention over time, the average time that the socks were worn, and the number of days that the socks were worn per month and per week. Results: A total of 160 patients wore the smart sock RPM device for 22 to 25 days per month on average. The retention rate was 91.9% (147/160) at the end of the 7-month period; a total of 13 patients were lost to follow-up during this period. The average number of days that the socks were worn per week was 5.8. The percentage of patients with a utilization rate of >15 days ranged from 79.7% (106/133) to 91.9% (125/136) each month. Conclusions: This study shows a high level of utilization for a smart sock RPM device and a high compliance rate. A future prospective study on the clinical outcomes after the use of the smart socks may further solidify the idea of conducting temperature monitoring for foot ulcer prevention.
- 1 March 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (3) , e32934
Open AccessUtilization of a Smart Sock for the Remote Monitoring of Patients With Peripheral Neuropathy: Cross-sectional Study of a Real-world Registry
Background: Remote patient monitoring (RPM) devices are increasingly being used in caring for patients to reduce risks of complications. Temperature monitoring specifically has been shown in previous studies to provide a useful signal of inflammation that may help prevent foot ulcers. Objective: In this cross-sectional study, we evaluated utilization data for patients who were prescribed smart socks as remote temperature monitoring devices. Methods: This study evaluated data from a patient registry from January to July 2021. The utilization data, which were collected starting from the first full month since patients were prescribed the smart socks, were evaluated along with retention over time, the average time that the socks were worn, and the number of days that the socks were worn per month and per week. Results: A total of 160 patients wore the smart sock RPM device for 22 to 25 days per month on average. The retention rate was 91.9% (147/160) at the end of the 7-month period; a total of 13 patients were lost to follow-up during this period. The average number of days that the socks were worn per week was 5.8. The percentage of patients with a utilization rate of >15 days ranged from 79.7% (106/133) to 91.9% (125/136) each month. Conclusions: This study shows a high level of utilization for a smart sock RPM device and a high compliance rate. A future prospective study on the clinical outcomes after the use of the smart socks may further solidify the idea of conducting temperature monitoring for foot ulcer prevention.
- Open Access
- 17 August 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Utilization of a Smart Sock for the Remote Monitoring of Patients With Peripheral Neuropathy: Cross-sectional Study of a Real-world Registry (Preprint)
BACKGROUND Remote patient monitoring (RPM) devices are increasingly being used in caring for patients to reduce risks of complications. Temperature monitoring specifically has been shown in previous studies to provide a useful signal of inflammation that may help prevent foot ulcers. OBJECTIVE In this cross-sectional study, we evaluated utilization data for patients who were prescribed smart socks as remote temperature monitoring devices. METHODS This study evaluated data from a patient registry from January to July 2021. The utilization data, which were collected starting from the first full month since patients were prescribed the smart socks, were evaluated along with retention over time, the average time that the socks were worn, and the number of days that the socks were worn per month and per week. RESULTS A total of 160 patients wore the smart sock RPM device for 22 to 25 days per month on average. The retention rate was 91.9% (147/160) at the end of the 7-month period; a total of 13 patients were lost to follow-up during this period. The average number of days that the socks were worn per week was 5.8. The percentage of patients with a utilization rate of >15 days ranged from 79.7% (106/133) to 91.9% (125/136) each month. CONCLUSIONS This study shows a high level of utilization for a smart sock RPM device and a high compliance rate. A future prospective study on the clinical outcomes after the use of the smart socks may further solidify the idea of conducting temperature monitoring for foot ulcer prevention.
- 17 August 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUtilization of a Smart Sock for the Remote Monitoring of Patients With Peripheral Neuropathy: Cross-sectional Study of a Real-world Registry (Preprint)
BACKGROUND Remote patient monitoring (RPM) devices are increasingly being used in caring for patients to reduce risks of complications. Temperature monitoring specifically has been shown in previous studies to provide a useful signal of inflammation that may help prevent foot ulcers. OBJECTIVE In this cross-sectional study, we evaluated utilization data for patients who were prescribed smart socks as remote temperature monitoring devices. METHODS This study evaluated data from a patient registry from January to July 2021. The utilization data, which were collected starting from the first full month since patients were prescribed the smart socks, were evaluated along with retention over time, the average time that the socks were worn, and the number of days that the socks were worn per month and per week. RESULTS A total of 160 patients wore the smart sock RPM device for 22 to 25 days per month on average. The retention rate was 91.9% (147/160) at the end of the 7-month period; a total of 13 patients were lost to follow-up during this period. The average number of days that the socks were worn per week was 5.8. The percentage of patients with a utilization rate of >15 days ranged from 79.7% (106/133) to 91.9% (125/136) each month. CONCLUSIONS This study shows a high level of utilization for a smart sock RPM device and a high compliance rate. A future prospective study on the clinical outcomes after the use of the smart socks may further solidify the idea of conducting temperature monitoring for foot ulcer prevention.
- Open Access
- 8 July 2021
- Published by JMIR Publications Inc. in JMIR Preprints
An Evaluation of Real-world Smart Sock–Based Temperature Monitoring Data as a Physiological Indicator of Early Diabetic Foot Injury: Case-Control Study (Preprint)
BACKGROUND Lower extremity complications of diabetes represent major health care complications both in terms of cost and impact to quality of life for patients with diabetic peripheral neuropathy. Temperature monitoring has been shown in previous studies to provide a useful signal of inflammation that may indicate the early presence of a foot injury. OBJECTIVE In this study, we evaluated the temperature data for patients that presented with a diabetic foot injury while using a sock-based remote temperature monitoring device. METHODS The study abstracted data from patients who were enrolled in a remote temperature monitoring program (2020-2021) using a smart sock (Siren Care). In the study cohort, a total of 5 participants with a diabetes-related lower extremity injury during the study period were identified. In the second comparison cohort, a total of 26 patients met the criteria for monitoring by the same methods but did not present with a diabetes-related podiatric lower extremity injury during the same period. The 15-day temperature differential between 6 defined locations on each foot was the primary outcome measure among subjects who presented with a diagnosed foot injury. Paired t tests were used to compare the differences between the two groups. RESULTS A significant difference in temperature differential (temperature measured in °F) was observed in the group that presented with a podiatric injury over the course of evaluation versus the comparator group that did not present with a podiatric injury. The average difference from all 6 measured points was 1.4 °F between the injury group (mean 3.6, SD 3.0) and the comparator group (mean 2.2, SD 2.5, t=–71.4, df=39; P<.001). CONCLUSIONS The results of this study suggest temperature monitoring in a sock form factor could be used to predict a developing foot injury. The continuous temperature monitoring system employed has implications for further algorithm development to enable early detection. The study was limited by a nonrandomized, observational design with limited injuries present in the study period. We look forward to further studies that will refine the predictive potential and confirm or refute the current promising data.
- 8 July 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAn Evaluation of Real-world Smart Sock–Based Temperature Monitoring Data as a Physiological Indicator of Early Diabetic Foot Injury: Case-Control Study (Preprint)
BACKGROUND Lower extremity complications of diabetes represent major health care complications both in terms of cost and impact to quality of life for patients with diabetic peripheral neuropathy. Temperature monitoring has been shown in previous studies to provide a useful signal of inflammation that may indicate the early presence of a foot injury. OBJECTIVE In this study, we evaluated the temperature data for patients that presented with a diabetic foot injury while using a sock-based remote temperature monitoring device. METHODS The study abstracted data from patients who were enrolled in a remote temperature monitoring program (2020-2021) using a smart sock (Siren Care). In the study cohort, a total of 5 participants with a diabetes-related lower extremity injury during the study period were identified. In the second comparison cohort, a total of 26 patients met the criteria for monitoring by the same methods but did not present with a diabetes-related podiatric lower extremity injury during the same period. The 15-day temperature differential between 6 defined locations on each foot was the primary outcome measure among subjects who presented with a diagnosed foot injury. Paired t tests were used to compare the differences between the two groups. RESULTS A significant difference in temperature differential (temperature measured in °F) was observed in the group that presented with a podiatric injury over the course of evaluation versus the comparator group that did not present with a podiatric injury. The average difference from all 6 measured points was 1.4 °F between the injury group (mean 3.6, SD 3.0) and the comparator group (mean 2.2, SD 2.5, t=–71.4, df=39; P<.001). CONCLUSIONS The results of this study suggest temperature monitoring in a sock form factor could be used to predict a developing foot injury. The continuous temperature monitoring system employed has implications for further algorithm development to enable early detection. The study was limited by a nonrandomized, observational design with limited injuries present in the study period. We look forward to further studies that will refine the predictive potential and confirm or refute the current promising data.