ZYZeming Yang

Zeming Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zeming Yang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Frequency-agile OFDM Backscatter

    by Bingbing Wang, Fengyuan Zhu, Wenhui Li, Zeming Yang, Meng Jin, Xiaohua Tian

    This paper presents FaB, a frequency-agile backscatter system that can optionally leverage OFDM signals on different bands as carriers for backscatter communication. Compared with existing backscatter systems that are tailored to a specific frequency band, a frequency-agile backscatter yields two critical benefits: i) it can leverage the increased availability of "free rides" across a broad range of frequency band to improve its transmission efficiency; and ii) it becomes compatible with mainstream wireless communication standards, making it applicable to heterogeneous wireless networks. Based on these two features, FaB's circuits can be migrated to various types of backscatter communication nodes without any modification, significantly reducing design and deployment costs. To show the efficacy of our design, we implement a PCB prototype of FaB and showcase its capability of leveraging OFDM Wi-Fi and LTE signals as carrier waves. Our extensive field studies show that FaB's multi-band modulator can produce an error vector magnitude of under -15dB in any band below 6GHz with a precision of 10mV.


  • Sub-Nyquist Sampling of ECG Signals With Differentiated VPW Optimization Model

    by Guoxing Huang, Zeming Yang, Weidang Lu, Hong Peng, Jingwen Wang

    In recent years, developments in wearable technologies and wireless communication have enabled wearable ECG monitoring. Long-term ECG monitoring result in large amounts of data. To sub-Nyquist sampling ECG signal, recently developed finite rate of innovation (FRI) technology is a practical option. However, existing FRI sampling schemes generally suffered from large model mismatch errors and insufficient reconstruction accuracy. In this paper, a sub-Nyquist sampling scheme based on the differentiated VPW optimization model is proposed for ECG signals sampling. The original ECG signal is modeled as a linear combination of several differentiated Variable Pulse Width (VPW) pulses and a model mismatch error signal. Then, a two-channel sampling framework is proposed to sample ECG signals with a sub-Nyquist rate. To improve the accuracy of the reconstruction, optimizing the reconstruction is considered. We formulate the objective function of the optimization to minimize the model mismatch error signal. A particle filter-based optimization method is proposed to solve the objective function with a high-dimensional variable. Block coordinate descent (BCD) technique is considered in the proposed optimization method. Finally, we conduct several simulations with real ECG signals from MIT-BIH Arrhythmia Database to test the performance of our proposed scheme. Simulation results have demonstrated the reconstruction accuracy of our proposed scheme outperforms other related schemes.


  • Sub-Nyquist Sampling of ECG Signals Based on the Extension of Variable Pulsewidth Model

    by Guoxing Huang, Zeming Yang, Weidang Lu, Hong Peng, Jingwen Wang

    To prevent lifestyle diseases, portable heartbeat detection systems by electrocardiograms (ECGs) for daily life monitoring have attracted attentions. For portable systems, power consumption is critical and it is thus beneficial to reduce the sampling frequency at the point of acquisition. Recent developed variable pulsewidth finite rate of innovation (VPW-FRI) framework provides an effective way for low-rate sampling and compression of ECG signals. Unfortunately, noise and model mismatch will induce inaccuracies to such scheme in the reconstruction process. In this article, a sub-Nyquist sampling scheme based on the extension of VPW model is proposed for ECG signals, which reduce the model dismatch error, and improve the reconstruction quality under model mismatch and noise scenario. In the proposed scheme, ECG signal is modeled as the differentiated VPW model to reduce the model mismatch error. Then a FRI sampling framework based on the differentiated VPW model is proposed to sample the ECG signal at a sub-Nyquist rate. After the ECG signal is sampled, some consecutive Fourier series coefficients are calculated according to the samples. Then a modified annihilating filter algorithm is proposed to estimate parameters of the ECG signal and reconstruct the ECG signal. Finally, simulation experiments with real ECG signals from Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) Arrhythmia Database have shown that the proposed scheme outperformed the traditional methods for model mismatch. The signal-to-residual ratio (SRR) of the reconstructed signal of the proposed scheme is higher than that of the VPW-FRI scheme.