Zhiyuan Weng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiyuan Weng has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zhouyi Wang
Nanjing University of Aeronautics and Astronautics
5 shared publications - Liuwei Wang
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
4 shared publications - Qingsong Yuan
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
3 shared publications - Qijun Jiang
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications - Zhendong Dai
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications - Bingcheng Wang
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
1 shared publication
Latest Publications
- Open Access
- 12 February 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (2) , 140
Pneumatic–Cable-Hybrid-Driven Multi-Mechanism End Effector and Cross-Surface Validation
Wall-climbing robots are increasingly required for applications in aerospace, high-altitude operations, and complex environmental monitoring, where they must maintain reliable adhesion and continuous mobility across surfaces with rapidly changing material properties and roughness. Achieving these demands requires lightweight systems with end effectors that integrate multi-surface adaptability and load-carrying capacity. Current single adhesion mechanisms are typically effective only under specific wall conditions, making it challenging to achieve stable, continuous adhesion and detachment on surfaces with significantly different roughness. To address this limitation, we propose a flexible, multi-mechanism coupled end effector driven by a pneumatic–cable hybrid system, integrating two complementary adhesion mechanisms—claw-based interlocking and vacuum suction—into a unified flexible structure. First, we develop the overall structural framework of the end effector and conduct finite element simulations to analyze key structural parameters of the telescopic cavity. We then establish a contact force model between the claw and vertical rough surfaces to clarify the interlocking adhesion mechanism and determine critical geometric parameters. Based on these analyses, a cable-driven adjustment mechanism is introduced to enable dynamic self-adaptation and assist with load-bearing during adhesion, enhancing the stability and load-carrying capacity under varying wall conditions. On rough surfaces, the end effector achieves reliable adhesion through claw interlocking, while on smooth surfaces, it maintains stable attachment through vacuum suction. Furthermore, it supports seamless switching between adhesion modes on different surfaces. When integrated into a wall-climbing robot, the system enables stable adhesion and detachment on both rough and smooth surfaces, providing a feasible solution for the lightweight, integrated design of end effectors for multi-surface adaptive wall-climbing robots.
- 12 February 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (2) , 140
Open AccessPneumatic–Cable-Hybrid-Driven Multi-Mechanism End Effector and Cross-Surface Validation
Wall-climbing robots are increasingly required for applications in aerospace, high-altitude operations, and complex environmental monitoring, where they must maintain reliable adhesion and continuous mobility across surfaces with rapidly changing material properties and roughness. Achieving these demands requires lightweight systems with end effectors that integrate multi-surface adaptability and load-carrying capacity. Current single adhesion mechanisms are typically effective only under specific wall conditions, making it challenging to achieve stable, continuous adhesion and detachment on surfaces with significantly different roughness. To address this limitation, we propose a flexible, multi-mechanism coupled end effector driven by a pneumatic–cable hybrid system, integrating two complementary adhesion mechanisms—claw-based interlocking and vacuum suction—into a unified flexible structure. First, we develop the overall structural framework of the end effector and conduct finite element simulations to analyze key structural parameters of the telescopic cavity. We then establish a contact force model between the claw and vertical rough surfaces to clarify the interlocking adhesion mechanism and determine critical geometric parameters. Based on these analyses, a cable-driven adjustment mechanism is introduced to enable dynamic self-adaptation and assist with load-bearing during adhesion, enhancing the stability and load-carrying capacity under varying wall conditions. On rough surfaces, the end effector achieves reliable adhesion through claw interlocking, while on smooth surfaces, it maintains stable attachment through vacuum suction. Furthermore, it supports seamless switching between adhesion modes on different surfaces. When integrated into a wall-climbing robot, the system enables stable adhesion and detachment on both rough and smooth surfaces, providing a feasible solution for the lightweight, integrated design of end effectors for multi-surface adaptive wall-climbing robots.
- Open Access
- 16 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 40
Reversible Adhesive Bio-Toe with Hierarchical Structure Inspired by Gecko
The agile locomotion of adhesive animals is mainly attributed to their sophisticated hierarchical feet and reversible adhesion motility. Their structure–function relationship is an urgent issue to be solved to understand biologic adhesive systems and the design of bionic applications. In this study, the reversible adhesion/release behavior and structural properties of gecko toes were investigated, and a hierarchical adhesive bionic toe (bio-toe) consisting of an upper elastic actuator as the supporting/driving layer and lower bionic lamellae (bio-lamellae) as the adhesive layer was designed, which can adhere to and release from targets reversibly when driven by bi-directional pressure. A mathematical model of the nonlinear deformation and a finite element model of the adhesive contact of the bio-toe were developed. Meanwhile, combined with experimental tests, the effects of the structure and actuation on the adhesive behavior and mechanical properties of the bio-toe were investigated. The research found that (1) the bending curvature of the bio-toe, which is approximately linear with pressure, enables the bio-toe to adapt to a wide range of objects controllably; (2) the tabular bio-lamella could achieve a contact rate of 60% with a low squeeze contact of less than 0.5 N despite a ±10° tilt in contact posture; (3) the upward bending of the bio-toe under negative pressure provided sufficient rebounding force for a 100% success rate of release; (4) the ratio of shear adhesion force to preload of the bio-toe with tabular bio-lamellae reaches approximately 12, which is higher than that of most existing adhesion units and frictional gripping units. The bio-toe shows good adaptability, load capacity, and reversibility of adhesion when applied as the basic adhesive unit in a robot gripper and wall-climbing robot. Finally, the proposed reversible adhesive bio-toe with a hierarchical structure has great potential for application in space, defense, industry, and daily life.
- 16 January 2023
- Published by MDPI AG in Biomimetics
- Vol. 8 (1) , 40
Open AccessReversible Adhesive Bio-Toe with Hierarchical Structure Inspired by Gecko
The agile locomotion of adhesive animals is mainly attributed to their sophisticated hierarchical feet and reversible adhesion motility. Their structure–function relationship is an urgent issue to be solved to understand biologic adhesive systems and the design of bionic applications. In this study, the reversible adhesion/release behavior and structural properties of gecko toes were investigated, and a hierarchical adhesive bionic toe (bio-toe) consisting of an upper elastic actuator as the supporting/driving layer and lower bionic lamellae (bio-lamellae) as the adhesive layer was designed, which can adhere to and release from targets reversibly when driven by bi-directional pressure. A mathematical model of the nonlinear deformation and a finite element model of the adhesive contact of the bio-toe were developed. Meanwhile, combined with experimental tests, the effects of the structure and actuation on the adhesive behavior and mechanical properties of the bio-toe were investigated. The research found that (1) the bending curvature of the bio-toe, which is approximately linear with pressure, enables the bio-toe to adapt to a wide range of objects controllably; (2) the tabular bio-lamella could achieve a contact rate of 60% with a low squeeze contact of less than 0.5 N despite a ±10° tilt in contact posture; (3) the upward bending of the bio-toe under negative pressure provided sufficient rebounding force for a 100% success rate of release; (4) the ratio of shear adhesion force to preload of the bio-toe with tabular bio-lamellae reaches approximately 12, which is higher than that of most existing adhesion units and frictional gripping units. The bio-toe shows good adaptability, load capacity, and reversibility of adhesion when applied as the basic adhesive unit in a robot gripper and wall-climbing robot. Finally, the proposed reversible adhesive bio-toe with a hierarchical structure has great potential for application in space, defense, industry, and daily life.
- Open Access
Effects of Flexural Rigidity on Soft Actuators via Adhering to Large Cylinders
This study proposes a soft pneumatic actuator with adhesion (SPAA) consisting of a top fluidic-driven elastic actuator and four bottom adhesive pads for adhering to large cylinders. Finite element models were developed to investigate the bending properties under positive air pressure and the effect of “rib” height on the flexural rigidity of the SPAA. A synchronous testing platform for the adhesive contact state and mechanics was developed, and the bending curvature and flexural rigidity of the SPAA were experimentally measured relative to the pressure and “rib” height, respectively, including the adhesion performance of the SPAA with different rigidities on large cylinders. The obtained results indicate that the SPAA can continuously bend with controllable curvature under positive air pressure and can actively envelop a wide range of cylinders of different curvatures. The increase in the “rib” height from 4 to 8 mm increases the flexural rigidity of the SPAA by approximately 230%, contributing to an average increase of 54% in the adhesion performance of the SPAA adhering to large cylinders. The adhesion performance increases more significantly with an increase in the flexural rigidity at a smaller peeling angle. SPAA has a better adhesion performance on large cylinders than most existing soft adhesive actuators, implying that is more stable and less affected by the curvature of cylinders. To address the low contact ratio of the SPAA during adhesion, the optimization designs of the rigid–flexible coupling hierarchical and differentiated AP structures were proposed to increase the contact ratio to more than 80% in the simulation. In conclusion, this study improved the adhesion performance of soft adhesive actuators on large cylinders and extended the application scope of adhesion technology. SPAA is a basic adhesive unit with a universal structure and large aspect ratio similar to that of the human finger. According to working conditions requirements, SPAAs can be assembled to a multi-finger flexible adhesive gripper with excellent maneuverability.
Open AccessEffects of Flexural Rigidity on Soft Actuators via Adhering to Large Cylinders
This study proposes a soft pneumatic actuator with adhesion (SPAA) consisting of a top fluidic-driven elastic actuator and four bottom adhesive pads for adhering to large cylinders. Finite element models were developed to investigate the bending properties under positive air pressure and the effect of “rib” height on the flexural rigidity of the SPAA. A synchronous testing platform for the adhesive contact state and mechanics was developed, and the bending curvature and flexural rigidity of the SPAA were experimentally measured relative to the pressure and “rib” height, respectively, including the adhesion performance of the SPAA with different rigidities on large cylinders. The obtained results indicate that the SPAA can continuously bend with controllable curvature under positive air pressure and can actively envelop a wide range of cylinders of different curvatures. The increase in the “rib” height from 4 to 8 mm increases the flexural rigidity of the SPAA by approximately 230%, contributing to an average increase of 54% in the adhesion performance of the SPAA adhering to large cylinders. The adhesion performance increases more significantly with an increase in the flexural rigidity at a smaller peeling angle. SPAA has a better adhesion performance on large cylinders than most existing soft adhesive actuators, implying that is more stable and less affected by the curvature of cylinders. To address the low contact ratio of the SPAA during adhesion, the optimization designs of the rigid–flexible coupling hierarchical and differentiated AP structures were proposed to increase the contact ratio to more than 80% in the simulation. In conclusion, this study improved the adhesion performance of soft adhesive actuators on large cylinders and extended the application scope of adhesion technology. SPAA is a basic adhesive unit with a universal structure and large aspect ratio similar to that of the human finger. According to working conditions requirements, SPAAs can be assembled to a multi-finger flexible adhesive gripper with excellent maneuverability.
- Open Access
- 26 August 2022
- Published by MDPI AG in Biomimetics
- Vol. 7 (3) , 119
Effect of the Structural Characteristics on Attachment-Detachment Mechanics of a Rigid-Flexible Coupling Adhesive Unit
The terminal toes of adhesive animals are characterized by rigid-flexible coupling, and their structure–function relationship is an urgent problem to be solved in understanding bioinspired adhesive systems and the design of biomimetic adhesive units. In this paper, inspired by the rigid-flexible coupling adhesive system of the gecko toe, a rigid-flexible coupling adhesive unit was designed, the interface strength of the adhesives under different preloads was tested, and the model and analysis method of the compression and peeling process of the rigid-flexible coupling adhesive unit was established. Meanwhile, combined with the experimental test, the effect of the coupling mechanism of the rigid-flexible structure on the interfacial stress and the final peeling force during the compression and peeling process of the adhesive unit was studied. The research found that the length of the adhesive unit L has no apparent effect on the normal peel force of the system within a specific range, and the normal peeling force increases linearly with the increase in the compression force P; while the influence of the inclination angle θ0 of the adhesive unit and the thickness of the rigid backing layer hb on the final normal peeling force of the system presents nonlinear characteristics, when the inclination angle θ0 of the adhesive unit is 5°, and the thickness of the rigid backing layer hb is 0.2 mm or 0.3 mm, the normal peel force and the ratio of adhesion force to preload the system reaches its maximum value. Compared with the flexible adhesive unit, the compressed zone formed by the rigid-flexible coupling adhesive unit during the same compression process increased by 6.7 times, while under the same peeling force, the peel zone increased by 8 times, and the maximum normal tensile stress at the peeling end decreased by 20 times. The rigid-flexible coupling mechanics improves the uniformity of the contact stress during the compression and peeling process. The research results provide guidelines for the design of the rigid-flexible coupling adhesive unit, further providing the end effector of the bionic wall-climbing robot with a rigid-flexible coupled bionic design.
- 26 August 2022
- Published by MDPI AG in Biomimetics
- Vol. 7 (3) , 119
Open AccessEffect of the Structural Characteristics on Attachment-Detachment Mechanics of a Rigid-Flexible Coupling Adhesive Unit
The terminal toes of adhesive animals are characterized by rigid-flexible coupling, and their structure–function relationship is an urgent problem to be solved in understanding bioinspired adhesive systems and the design of biomimetic adhesive units. In this paper, inspired by the rigid-flexible coupling adhesive system of the gecko toe, a rigid-flexible coupling adhesive unit was designed, the interface strength of the adhesives under different preloads was tested, and the model and analysis method of the compression and peeling process of the rigid-flexible coupling adhesive unit was established. Meanwhile, combined with the experimental test, the effect of the coupling mechanism of the rigid-flexible structure on the interfacial stress and the final peeling force during the compression and peeling process of the adhesive unit was studied. The research found that the length of the adhesive unit L has no apparent effect on the normal peel force of the system within a specific range, and the normal peeling force increases linearly with the increase in the compression force P; while the influence of the inclination angle θ0 of the adhesive unit and the thickness of the rigid backing layer hb on the final normal peeling force of the system presents nonlinear characteristics, when the inclination angle θ0 of the adhesive unit is 5°, and the thickness of the rigid backing layer hb is 0.2 mm or 0.3 mm, the normal peel force and the ratio of adhesion force to preload the system reaches its maximum value. Compared with the flexible adhesive unit, the compressed zone formed by the rigid-flexible coupling adhesive unit during the same compression process increased by 6.7 times, while under the same peeling force, the peel zone increased by 8 times, and the maximum normal tensile stress at the peeling end decreased by 20 times. The rigid-flexible coupling mechanics improves the uniformity of the contact stress during the compression and peeling process. The research results provide guidelines for the design of the rigid-flexible coupling adhesive unit, further providing the end effector of the bionic wall-climbing robot with a rigid-flexible coupled bionic design.
- Open Access
Fabrication of Flexible Multi-Cavity Bio-Inspired Adhesive Unit Using Laminated Mold Pouring
To meet the requirements for the flexible end-effectors of industrial grippers and climbing robots, inspired by the animal attachment mechanism, a bio-inspired adhesive unit (Bio-AU) was designed. Due to its fluid-driven operating characteristics and multi-level adhesive structure, its fabrication and molding is challenging, including the assembly and molding of complex cavities with good pressure-bearing capability, mechanical properties of multi-level materials with variable stiffness, etc. In this study, based on the lamination mold casting process, the “simultaneous molding and assembly” method was established, which can be applied to form and assemble complex cavity parts simultaneously. Moreover, the dovetail tenon-and-mortise parting structures were analyzed and designed. Furthermore, the adhesion between the parting surfaces can be improved using plasma surface treatment technology. By applying the above methods, the assembly accuracy and pressure-bearing capability of the complex flexible cavities are improved, which reduces the individual differences between finished products. Additionally, the maximum pressure-bearing value of the sample was 83 kPa, which is 1.75 times that before optimization. the adhesive structure with different stiffness components was fabricated at low cost using silicon rubber substrates with different properties, which met the requirements of multi-level material with variable stiffness of the Bio-AU. The bending angle of the optimized molding product was about 50.9° at 80 kPa, which is significantly larger than the 24.6° of the lighting-cured product. This indicates that the optimized lamination mold casting process has a strong inclusion of materials, which improves the deformation capacity and self-adaptability of Bio-AUs and overcomes the defects of 3D printing technology in the formation of large, flexible, and controllable-stiffness structures. In this study, the effective fabrication of flexible multilayer adhesive structures was accomplished, and technical support for the development of Bio-AUs was provided, which met the requirements of bionic climbing robots and industrial adhesive grippers for end-effectors.
Open AccessFabrication of Flexible Multi-Cavity Bio-Inspired Adhesive Unit Using Laminated Mold Pouring
To meet the requirements for the flexible end-effectors of industrial grippers and climbing robots, inspired by the animal attachment mechanism, a bio-inspired adhesive unit (Bio-AU) was designed. Due to its fluid-driven operating characteristics and multi-level adhesive structure, its fabrication and molding is challenging, including the assembly and molding of complex cavities with good pressure-bearing capability, mechanical properties of multi-level materials with variable stiffness, etc. In this study, based on the lamination mold casting process, the “simultaneous molding and assembly” method was established, which can be applied to form and assemble complex cavity parts simultaneously. Moreover, the dovetail tenon-and-mortise parting structures were analyzed and designed. Furthermore, the adhesion between the parting surfaces can be improved using plasma surface treatment technology. By applying the above methods, the assembly accuracy and pressure-bearing capability of the complex flexible cavities are improved, which reduces the individual differences between finished products. Additionally, the maximum pressure-bearing value of the sample was 83 kPa, which is 1.75 times that before optimization. the adhesive structure with different stiffness components was fabricated at low cost using silicon rubber substrates with different properties, which met the requirements of multi-level material with variable stiffness of the Bio-AU. The bending angle of the optimized molding product was about 50.9° at 80 kPa, which is significantly larger than the 24.6° of the lighting-cured product. This indicates that the optimized lamination mold casting process has a strong inclusion of materials, which improves the deformation capacity and self-adaptability of Bio-AUs and overcomes the defects of 3D printing technology in the formation of large, flexible, and controllable-stiffness structures. In this study, the effective fabrication of flexible multilayer adhesive structures was accomplished, and technical support for the development of Bio-AUs was provided, which met the requirements of bionic climbing robots and industrial adhesive grippers for end-effectors.