Bowu Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bowu Zhu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Baocheng Cao
Lanzhou University, Lanzhou, China
2 shared publicationsJun Liang
Chinese Academy of Sciences Lanzhou Branch, Lanzhou, China
2 shared publications- Baoping Shao
School of Life Sciences, Lanzhou University, Key Laboratory of Biomonitoring and Bioremediation for Environmental Pollution, Lanzhou 730000, Gansu Province, China
1 shared publication Duhong Li
Lanzhou University, Lanzhou, China
1 shared publication- Fuzhi Wu
College of Information Science and Technology & Artificial Intelligence, Nanjing Forestry University, No. 159 Longpan Road, Nanjing, 210037, CHINA
1 shared publication - Gang Lu
College of Computer Science and Engineering, Northwest Normal University, No. 967 Anning East Road, Lanzhou, Gansu, 730070, CHINA
1 shared publication
Latest Publications
- 21 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025007
Bi-level alignment with super-resolution head for unsupervised cephalometric landmark localization
Objective . Cephalometric alandmark localization is of great clinical significance in diagnosing and treating patients with dental-maxillofacial deformities. Domain shifts across clinical centers significantly hinder model generalizability, causing existing methods to struggle with accurate and robust anatomical landmark localization due to insufficient alignment of high-level semantic features across domains. We aim to improve the cross-domain generalizability of cephalometric landmark detection by aligning semantic features and enhancing output resolution under an unsupervised domain adaptation (UDA) setting. Approach . In this paper, we propose bi-Level alignment with super-resolution head, an effective framework for precise and robust anatomical landmark detection under UDA. Specifically, we employ adaptive instance normalization to generate target-style images while preserving original anatomical spatial structure at the input level. At the output level, a Mean–Teacher framework leverages high-quality pseudo-labels from the teacher model to guide the student model’s learning. Additionally, a lightweight super-resolution head enables the generation of high-resolution heatmaps from the multi-scale feature maps and the low-resolution heatmaps, reducing quantization errors with low computational cost. Results . The proposed method achieved a mean localization error of 1.64 mm, a successful detection rate of 72.68% within the clinically acceptable threshold of 2 mm, and an average classification accuracy of 81.81% for anatomical types. Significance . Extensive experiments on public cephalometric datasets demonstrate superiority over state-of-the-art UDA methods, highlighting its potential for clinical applications in cephalometric analysis and orthodontic surgery planning.
- 21 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025007
Bi-level alignment with super-resolution head for unsupervised cephalometric landmark localization
Objective . Cephalometric alandmark localization is of great clinical significance in diagnosing and treating patients with dental-maxillofacial deformities. Domain shifts across clinical centers significantly hinder model generalizability, causing existing methods to struggle with accurate and robust anatomical landmark localization due to insufficient alignment of high-level semantic features across domains. We aim to improve the cross-domain generalizability of cephalometric landmark detection by aligning semantic features and enhancing output resolution under an unsupervised domain adaptation (UDA) setting. Approach . In this paper, we propose bi-Level alignment with super-resolution head, an effective framework for precise and robust anatomical landmark detection under UDA. Specifically, we employ adaptive instance normalization to generate target-style images while preserving original anatomical spatial structure at the input level. At the output level, a Mean–Teacher framework leverages high-quality pseudo-labels from the teacher model to guide the student model’s learning. Additionally, a lightweight super-resolution head enables the generation of high-resolution heatmaps from the multi-scale feature maps and the low-resolution heatmaps, reducing quantization errors with low computational cost. Results . The proposed method achieved a mean localization error of 1.64 mm, a successful detection rate of 72.68% within the clinically acceptable threshold of 2 mm, and an average classification accuracy of 81.81% for anatomical types. Significance . Extensive experiments on public cephalometric datasets demonstrate superiority over state-of-the-art UDA methods, highlighting its potential for clinical applications in cephalometric analysis and orthodontic surgery planning.
- 15 August 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (5) , 930-941
Preparation and characterization of Y-doped microarc oxidation coating on AZ31 magnesium alloys
The rapid degradation characteristics of magnesium alloys limit its application in the field of orthopedic fracture fixation and cardiovascular stents. This study aimed to improve the corrosion resistance and biocompatibility of AZ31 magnesium alloys and prepare degradable implant materials. Micro-arc oxidation (MAO) was used to change the concentration of yttrium acetate in the electrolyte to prepare coatings with different yttrium content on the surface of AZ31 magnesium alloy. Through characterization, it is proved that the yttrium in the coating mainly exists in the form of Y3+. The polarization potential experiment shows that the micro-arc oxidation coating significantly improves the corrosion resistance of magnesium alloys. With the increase of yttrium acetate concentration in the electrolyte, the corrosion resistance of the coating first increases and then weakens. When the concentration is 0.0035 mol/L, the coating has the highest corrosion resistance. The results of CCK-8 cytotoxicity experiment and cell morphology observation also proved that the cell viability in each group was greater than 140%, and the yttrium-doped coating on the surface of AZ31 magnesium alloy has no cytotoxicity, can promote cell growth, and has good biocompatibility.
- 15 August 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 37 (5) , 930-941
Preparation and characterization of Y-doped microarc oxidation coating on AZ31 magnesium alloys
The rapid degradation characteristics of magnesium alloys limit its application in the field of orthopedic fracture fixation and cardiovascular stents. This study aimed to improve the corrosion resistance and biocompatibility of AZ31 magnesium alloys and prepare degradable implant materials. Micro-arc oxidation (MAO) was used to change the concentration of yttrium acetate in the electrolyte to prepare coatings with different yttrium content on the surface of AZ31 magnesium alloy. Through characterization, it is proved that the yttrium in the coating mainly exists in the form of Y3+. The polarization potential experiment shows that the micro-arc oxidation coating significantly improves the corrosion resistance of magnesium alloys. With the increase of yttrium acetate concentration in the electrolyte, the corrosion resistance of the coating first increases and then weakens. When the concentration is 0.0035 mol/L, the coating has the highest corrosion resistance. The results of CCK-8 cytotoxicity experiment and cell morphology observation also proved that the cell viability in each group was greater than 140%, and the yttrium-doped coating on the surface of AZ31 magnesium alloy has no cytotoxicity, can promote cell growth, and has good biocompatibility.
- 14 February 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 36 (9) , 1664-1675
Improving corrosion resistance and biocompatibility of AZ31 magnesium alloy by ultrasonic cold forging and micro-arc oxidation
Corrosion resistant and biocompatible AZ31 magnesium alloy surfaces were successfully prepared by ultrasonic cold forging and subsequent micro-arc oxidation. The properties of these ultrasonic cold forging pretreated (UCFT)AZ31 magnesium alloy surfaces containing Sr–Ca–P micro-arc oxide coating (MAO/UCFT/AZ31) were studied. Results showed that surface grain refinement of AZ31 Mg alloy in the depth of 400 μm owing to the ultrasonic cold forging pretreatment was verified, and which provides more discharge channels for subsequent micro-arc oxidation. Comparing with the AZ31 magnesium alloy (AZ31) and ultrasonic cold forging technology treated AZ31 magnesium alloy samples (UCFT/AZ31), the corrosion resistance of MAO/UCFT/AZ31 significantly improved, which is also supported by the immersion experiments and electrochemical tests in simulated body fluid. Meanwhile, the MAO/UCFT/AZ31 samples also had excellent cytocompatibility as well as MAO/AZ31 samples. These results may beneficial to the developing of biodegradable medical materials in future.
- 14 February 2022
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 36 (9) , 1664-1675
Improving corrosion resistance and biocompatibility of AZ31 magnesium alloy by ultrasonic cold forging and micro-arc oxidation
Corrosion resistant and biocompatible AZ31 magnesium alloy surfaces were successfully prepared by ultrasonic cold forging and subsequent micro-arc oxidation. The properties of these ultrasonic cold forging pretreated (UCFT)AZ31 magnesium alloy surfaces containing Sr–Ca–P micro-arc oxide coating (MAO/UCFT/AZ31) were studied. Results showed that surface grain refinement of AZ31 Mg alloy in the depth of 400 μm owing to the ultrasonic cold forging pretreatment was verified, and which provides more discharge channels for subsequent micro-arc oxidation. Comparing with the AZ31 magnesium alloy (AZ31) and ultrasonic cold forging technology treated AZ31 magnesium alloy samples (UCFT/AZ31), the corrosion resistance of MAO/UCFT/AZ31 significantly improved, which is also supported by the immersion experiments and electrochemical tests in simulated body fluid. Meanwhile, the MAO/UCFT/AZ31 samples also had excellent cytocompatibility as well as MAO/AZ31 samples. These results may beneficial to the developing of biodegradable medical materials in future.