LRLingling Ran

Lingling Ran

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lingling Ran has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction: Zhang et al. Tunable Triple Plasmonically Induced Transparency in Triangular Cavities Coupled with an MDM Waveguide. Photonics 2022, 9, 100

    by Jingyu Zhang, Hengli Feng, Chang Liu, Dongchao Fang, Jincheng Wang, Lehui Wang, Zuoxin Zhang, Lingling Ran, Yang Gao

  • Fiber-Optic Refractive Index Sensor via Macro-Bending Tapered Waveguide

    by Meiqi Gao, Lingling Ran, Jiuru Yang

    In this letter, a novel intensity modulated fiber-optic refractive index sensor is proposed based on the tapered no-cladding-double-cladding-multimode fiber structure fabricated by arc-discharged splicing technique. In order to further improve intensity response of external refractive index, the polylactic-acid based angled-package is prepared via 3D printing technique. The experimental results show that, due to the enhanced evanescent wave effect, the intensity changes are dramatically enhanced and the maximum reaches 1101.5 dB/RIU achieved by the 60-degree package, which corresponds the detection limit of $9.07\times 10^{-6}$ RIU. Besides, the ultra-low cross-sensitivity of $7.41\times 10^{-5}$ RIU/°C is gained owing to the tiny temperature shift of <0.1 dB/°C.


  • Open Access

    Fiber-Optic Axial-Strain Sensor with Sensitivity Enhancement and Temperature Compensation

    by Xiaotong Yang, Chuanxu Liu, Jiuru Yang, Dexue Sun, Lingling Ran

    In this paper, we report a tapered thin-core fiber based in-line Mach-Zehnder interferometer to improve the response of axial-strain. With the varied diameters of taper waist, the light field distributions are studied by beam propagation method, and the structures are fabricated by arc-discharged lateral offset splicing and tapering techniques. The comprehensive tests are then conducted and compared in terms of axial-strain and temperature. The experimental results show that, by reducing the diameter of taper waist, more than 400% enhancement of wavelength sensitivity can be gained, and the maximum reaches 4.07 pm/µε with the measured error of 3.6%. Moreover, owing to high consistency of temperature response, the near-zero crosstalk is presented by differential compensation method. Furthermore, owing to the merit of high repeatability and stability, our sensor is very practical and promising in the high-precision measurement and engineering monitoring.


  • Open Access

    Tunable Dual-Broadband Terahertz Absorber with Vanadium Dioxide Metamaterial

    by Hengli Feng, Zuoxin Zhang, Jingyu Zhang, Dongchao Fang, Jincheng Wang, Chang Liu, Tong Wu, Guan Wang, Lehui Wang, Lingling Ran, et al.

    A dual broadband terahertz bifunction absorber that can be actively tuned is proposed. The optical properties of the absorber were simulated and numerically calculated using the finite-difference time-domain (FDTD) method. The results show that when the conductivity of vanadium dioxide is less than σ0=8.5×103 S/m, the absorptance can be continuously adjusted between 2% and 100%. At vanadium dioxide conductivity greater than σ0=8.5×103 S/m, the absorption bandwidth of the absorber can be switched from 3.4 THz and 3.06 THz to 2.83 THz and none, respectively, and the absorptance remains above 90%. This achieves perfect modulation of the absorptance and absorption bandwidth. The physical mechanism of dual-broadband absorptions and perfect absorption is elucidated by impedance matching theory and electric field distribution. In addition, it also has the advantage of being polarization insensitive and maintaining stable absorption at wide angles of oblique incidence. The absorber may have applications in emerging fields such as modulators, stealth and light-guided optical switches.


  • Open Access

    Tunable Triple Plasmonically Induced Transparency in Triangular Cavities Coupled with an MDM Waveguide

    by Jingyu Zhang, Hengli Feng, Chang Liu, Dongchao Fang, Jincheng Wang, Lehui Wang, Zuoxin Zhang, Lingling Ran, Yang Gao

    In this paper, a side-coupled triangle cavity in a plasmonic waveguide structure is proposed and numerically analyzed by the finite-difference time-domain (FDTD) method and coupled mode theory (CMT). Triple plasmonically induced transparency (PIT) was achieved when an extra triangle was added into the structure, and the transmission characteristics were investigated. This novel structure has a maximal sensitivity of 933 nm/RIU when used as a sensor and a contrast ratio of 4 dB. Moreover, the tunability of PIT can be realized by filling the nematic liquid crystal (NLC) E7 into the triangles. The refractive index of E7 changes with the applied electric field. Given that E7 is also sensitive to temperature, this structure can be used as a temperature sensor with a sensitivity of 0.29 nm/°C. It is believed that this tunable structure with PIT may have potential applications in highly integrated optical circuits.


  • Open Access

    High Sensitivity Fiber Gas Pressure Sensor with Two Separated Fabry–Pérot Interferometers Based on the Vernier Effect

    by Xiaokang Song, Liangtao Hou, Xiangyu Wei, Hang Su, Chang Li, Yan Li, Lingling Ran

    A high sensitivity optical fiber gas pressure sensor based on paralleled Fabry–Pérot interferometers (FPIs) was demonstrated. One micro-cavity FPI is used as a reference FPI (FPI-1) to generate a Vernier effect and the other FPI (FPI-2) is used as a sensing tip. Both FPIs are connected by a 3-dB coupler to form a paralleled structure. The FPI-1 was fabricated by fusion splicing a piece of hollow core fiber (HCF) between two sections of single-mode fibers (SMF), whereas FPI-2 was formed by fusion splicing a section of HCF between SMF and a piece of HCF with a slightly smaller inner diameter for sensing pressure. The gas pressure sensitivity was amplified from 4 nm/MPa of single FPI to 45.76 nm/MPa of paralleled FPIs with an amplification factor of 11.44 and a linearity of 99.9%. Compared with the traditional fiber gas pressure sensors, the proposed sensor showed great advantages in sensitivity, mechanical strength, cost, and temperature influence resistant, which has potential in adverse-circumstance gas pressure sensing.


  • Ultra-Sensitive Optical Fiber Humidity Sensor via Au-Film-Assisted Polyvinyl Alcohol Micro-Cavity and Vernier Effect

    by Liangtao Hou, Yan Li, Yiming Fu, Jiuru Yang, Weijiang Xu, Xiaokang Song, Jinjian Li, Yi Liu, Lingling Ran

    To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.


  • Open Access

    Ultra-Sensitive Intensity Modulated Strain Sensor by Tapered Thin-Core Fiber Based Modal Interferometer

    by Chuanxu Liu, Dexue Sun, Jiuru Yang, Hui Zhang, Lingling Ran

    In this paper, to enhance practicality, a novel tapered thin-core fiber (t-TCF) based modal interferometer is proposed and demonstrated experimentally. The light field distribution of t-TCF structure is investigated by a beam propagation method, and the quantitative relationship is gained between light intensity loss and waist diameter. Under ~30 μm waist diameter, multiple t-TCF based sensor heads are fabricated by arc-discharged splicing and taper techniques, and comprehensive tests are performed with respects to axial strain and temperature. The experimental results show that, with near-zero wavelength shift, obvious intensity strain response is exhibited and negative-proportional to the reduced length of TCF. Thus, the maximum sensitivity reaches 0.119 dB/με when the TCF length is equal to 15 mm, and a sub-micro-strain detection resolution (about 0.084 με) is obtained. Besides, owing to the flat red-shifted temperature response, the calculated cross-sensitivity of our sensor is compressed within 0.32 με/°C, which is promising for high precision strain related engineering applications.


  • High Sensitivity Flow Velocity Sensor Based on All-Fiber Target-Type Structure

    by Liangtao Hou, Yan Li, Yi Liu, Lingling Ran, Jiuru Yang

    An all-fiber target-type flow velocity sensor was proposed and experimentally demonstrated based on the Michelson interferometer (MI). Commercially available single mode fiber (SMF) was used as the basic material and assisted with the arc discharge technology the sensing structure can be fabricated with high efficiency and quality. The designed sensor structure contains a peanut-shape structure that acts as a coupler/splitter, a SMF that acts as a cantilever beam, and a spherical tip that acts as a target, which all can be realized by arc discharge technology. The simulation verifies the effectiveness and high sensitivity of the peanut-shape structure for flow velocity measurement, and the key parameters were optimized. A comprehensive experiment was carried out on the flow velocity experiment. The experimental results show that the sensor has high sensitivity of -1.30 nm/(cm/s), precision of 1.4% and detection limit (DL) of 0.015 cm/s in the range of 0-11 cm/s. In addition, the temperature sensitivity is 58.5 pm/°C and the flow velocity-temperature cross-sensitivity is less than 0.05 (cm/s)/°C. Such a high-sensitivity, low cross-sensitivity and low-cost sensor, is very promising for the applications on high-precision liquid and abysmal sea flow velocity measurement.


  • Open Access

    Ultra-Sensitive Fiber Refractive Index Sensor with Intensity Modulation and Self-Temperature Compensation

    by Zhaojun Li, Liangtao Hou, Lingling Ran, Jing Kang, Jiuru Yang

    In this paper, a novel in-line modal interferometer for refractive index (RI) sensing is proposed and experimentally fabricated by cascading single-taper and multimode-double- cladding-multimode (MDM) fiber structure. Owing to evanescent field in taper area, the ultra-sensitive and linear intensity-responses to the varied surrounding RI are gained in both single- and double-pass structures. Moreover, the crosstalk from temperature can be effectively discriminated and compensated by means of the RI-free nature of MDM. The experimental results show that the RI sensitivities in single- and double-pass structures, respectively, reach 516.02 and 965.46 dB/RIU (RIU: refractive index unit), both with the slight wavelength shift (~0.2 nm). The temperature responses with respect to wavelength and intensity are 68.9 pm°C−1/0.103 dB°C−1 (single-pass structure) and 103 pm°C−1/0.082 dB·°C−1 (double-pass structure). So the calculated cross-sensitivity of intensity is constrained within 8.49 × 10−5 RIU/°C. In addition, our sensor presents high measurement-stability (~0.99) and low repeatability error (<4.8‰). On account of the ~620 μm size of taper, this compact sensor is cost-efficient, easy to fabricate, and very promising for the applications of biochemistry and biomedicine.