Samuel A. Max
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samuel A. Max has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Edris A. F. Mahtab
Department of Cardiothoracic Surgery, Leiden University Medical Center , Leiden, 2333 ZA
5 shared publications - Ad J. J. C. Bogers
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
3 shared publications - Amir H. Sadeghi
Department of Cardiothoracic Surgery, Radboud University Medical Centre , 6525 GA Nijmegen
3 shared publications - Jette J. Peek
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
3 shared publications Antony van Dijk
Department of Cardiothoracic Surgery, Erasmus MC University Medical Center , Rotterdam, 3015 GD
2 shared publications- Bryan G Martina
Department of Cardiothoracic Surgery Erasmus University Medical Center Rotterdam Netherlands
2 shared publications
Latest Publications
- Open Access
- 19 February 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (11)
Building an Extracorporeal Membrane Oxygenation Digital Twin Using High-Resolution Patient Data: An Artificial Intelligence Model for Virtual Reality Simulation
Objectives: Extracorporeal membrane oxygenation (ECMO) is a life-saving therapy for severe cardiopulmonary failure, but structured training remains constrained by costs, logistics, and the absence of validated high-fidelity simulators. This study aimed to develop an ECMO digital twin capable of supporting training in virtual reality (VR). Methods: We integrated high-frequency ECMO machine data with electronic health record information from 335 patients across 2 centres. Data streams were synchronized at a 30-s resolution. A hierarchical 2-stage system was designed: Model 1 predicted ECMO device outputs, while Model 2 combined those outputs with patient vital functions such as heart rate and blood pressure. This model was integrated into a VR simulation and underwent testing by 21 experts. Results: Model 2 demonstrated root mean square errors (RMSEs) of 15.23 mm Hg (diastolic arterial blood pressure), 19.50 BPM (heart rate), 2.94% (peripheral oxygen saturation), and 1.42 mm Hg (end-tidal carbon dioxide) on the test set. Neural networks produced clinically coherent predictions. The models were implemented in an unreal engine-based VR simulator using the open neural network exchange format, with real-time latency inference and scenario switching. Expert testing confirmed good performance and clinically plausible physiological responses in the simulation. Conclusions: High-resolution ECMO data can be transformed into a digital twin for VR training. This framework broadens access to advanced ECMO education and establishes a foundation for multicentre validation, federated learning, and future expansion towards a critical-care digital-twin platform.
- 19 February 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (11)
Open AccessBuilding an Extracorporeal Membrane Oxygenation Digital Twin Using High-Resolution Patient Data: An Artificial Intelligence Model for Virtual Reality Simulation
Objectives: Extracorporeal membrane oxygenation (ECMO) is a life-saving therapy for severe cardiopulmonary failure, but structured training remains constrained by costs, logistics, and the absence of validated high-fidelity simulators. This study aimed to develop an ECMO digital twin capable of supporting training in virtual reality (VR). Methods: We integrated high-frequency ECMO machine data with electronic health record information from 335 patients across 2 centres. Data streams were synchronized at a 30-s resolution. A hierarchical 2-stage system was designed: Model 1 predicted ECMO device outputs, while Model 2 combined those outputs with patient vital functions such as heart rate and blood pressure. This model was integrated into a VR simulation and underwent testing by 21 experts. Results: Model 2 demonstrated root mean square errors (RMSEs) of 15.23 mm Hg (diastolic arterial blood pressure), 19.50 BPM (heart rate), 2.94% (peripheral oxygen saturation), and 1.42 mm Hg (end-tidal carbon dioxide) on the test set. Neural networks produced clinically coherent predictions. The models were implemented in an unreal engine-based VR simulator using the open neural network exchange format, with real-time latency inference and scenario switching. Expert testing confirmed good performance and clinically plausible physiological responses in the simulation. Conclusions: High-resolution ECMO data can be transformed into a digital twin for VR training. This framework broadens access to advanced ECMO education and establishes a foundation for multicentre validation, federated learning, and future expansion towards a critical-care digital-twin platform.
- Open Access
- 20 December 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (4) , 787-795
A novel 3D image registration technique for augmented reality vision in minimally invasive thoracoscopic pulmonary segmentectomy
Purpose: In this feasibility study, we aimed to create a dedicated pulmonary augmented reality (AR) workflow to enable a semi-automated intraoperative overlay of the pulmonary anatomy during video-assisted thoracoscopic surgery (VATS) or robot-assisted thoracoscopic surgery (RATS). Methods: Initially, the stereoscopic cameras were calibrated to obtain the intrinsic camera parameters. Intraoperatively, stereoscopic images were recorded and a 3D point cloud was generated from these images. By manually selecting the bifurcation key points, the 3D segmentation (from the diagnostic CT scan) was registered onto the intraoperative 3D point cloud. Results: Image reprojection errors were 0.34 and 0.22 pixels for the VATS and RATS cameras, respectively. We created disparity maps and point clouds for all eight patients. Time for creation of the 3D AR overlay was 5 min. Validation of the point clouds was performed, resulting in a median absolute error of 0.20 mm [IQR 0.10–0.54]. We were able to visualize the AR overlay and identify the arterial bifurcations adequately for five patients. In addition to creating AR overlays of the visible or invisible structures intraoperatively, we successfully visualized branch labels and altered the transparency of the overlays. Conclusion: An algorithm was developed transforming the operative field into a 3D point cloud surface. This allowed for an accurate registration and visualization of preoperative 3D models. Using this system, surgeons can navigate through the patient's anatomy intraoperatively, especially during crucial moments, by visualizing otherwise invisible structures. This proposed registration method lays the groundwork for automated intraoperative AR navigation during minimally invasive pulmonary resections.
- 20 December 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 20 (4) , 787-795
Open AccessA novel 3D image registration technique for augmented reality vision in minimally invasive thoracoscopic pulmonary segmentectomy
Purpose: In this feasibility study, we aimed to create a dedicated pulmonary augmented reality (AR) workflow to enable a semi-automated intraoperative overlay of the pulmonary anatomy during video-assisted thoracoscopic surgery (VATS) or robot-assisted thoracoscopic surgery (RATS). Methods: Initially, the stereoscopic cameras were calibrated to obtain the intrinsic camera parameters. Intraoperatively, stereoscopic images were recorded and a 3D point cloud was generated from these images. By manually selecting the bifurcation key points, the 3D segmentation (from the diagnostic CT scan) was registered onto the intraoperative 3D point cloud. Results: Image reprojection errors were 0.34 and 0.22 pixels for the VATS and RATS cameras, respectively. We created disparity maps and point clouds for all eight patients. Time for creation of the 3D AR overlay was 5 min. Validation of the point clouds was performed, resulting in a median absolute error of 0.20 mm [IQR 0.10–0.54]. We were able to visualize the AR overlay and identify the arterial bifurcations adequately for five patients. In addition to creating AR overlays of the visible or invisible structures intraoperatively, we successfully visualized branch labels and altered the transparency of the overlays. Conclusion: An algorithm was developed transforming the operative field into a 3D point cloud surface. This allowed for an accurate registration and visualization of preoperative 3D models. Using this system, surgeons can navigate through the patient's anatomy intraoperatively, especially during crucial moments, by visualizing otherwise invisible structures. This proposed registration method lays the groundwork for automated intraoperative AR navigation during minimally invasive pulmonary resections.
- Open Access
- 20 June 2023
- Published by Elsevier in JTCVS Techniques
- Vol. 21, 135-148
Virtual reality simulation as a training tool for perfusionists in extracorporeal circulation: Establishing face and content validity
- 20 June 2023
- Published by Elsevier in JTCVS Techniques
- Vol. 21, 135-148
Open AccessVirtual reality simulation as a training tool for perfusionists in extracorporeal circulation: Establishing face and content validity
- Open Access
- 2 March 2022
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 10 (1) , e30456
Virtual Reality Simulation Training for Cardiopulmonary Resuscitation After Cardiac Surgery: Face and Content Validity Study
Background: Cardiac arrest after cardiac surgery commonly has a reversible cause, where emergency resternotomy is often required for treatment, as recommended by international guidelines. We have developed a virtual reality (VR) simulation for training of cardiopulmonary resuscitation (CPR) and emergency resternotomy procedures after cardiac surgery, the Cardiopulmonary Resuscitation Virtual Reality Simulator (CPVR-sim). Two fictive clinical scenarios were used: one case of pulseless electrical activity (PEA) and a combined case of PEA and ventricular fibrillation. In this prospective study, we researched the face validity and content validity of the CPVR-sim. Objective: We designed a prospective study to assess the feasibility and to establish the face and content validity of two clinical scenarios (shockable and nonshockable cardiac arrest) of the CPVR-sim partly divided into a group of novices and experts in performing CPR and emergency resternotomies in patients after cardiac surgery. Methods: Clinicians (staff cardiothoracic surgeons, physicians, surgical residents, nurse practitioners, and medical students) participated in this study and performed two different scenarios, either PEA or combined PEA and ventricular fibrillation. All participants (N=41) performed a simulation and completed the questionnaire rating the simulator’s usefulness, satisfaction, ease of use, effectiveness, and immersiveness to assess face validity and content validity. Results: Responses toward face validity and content validity were predominantly positive in both groups. Most participants in the PEA scenario (n=26, 87%) felt actively involved in the simulation, and 23 (77%) participants felt in charge of the situation. The participants thought it was easy to learn how to interact with the software (n=24, 80%) and thought that the software responded adequately (n=21, 70%). All 15 (100%) expert participants preferred VR training as an addition to conventional training. Moreover, 13 (87%) of the expert participants would recommend VR training to other colleagues, and 14 (93%) of the expert participants thought the CPVR-sim was a useful method to train for infrequent post–cardiac surgery emergencies requiring CPR. Additionally, 10 (91%) of the participants thought it was easy to move in the VR environment, and that the CPVR-sim responded adequately in this scenario. Conclusions: We developed a proof-of-concept VR simulation for CPR training with two scenarios of a patient after cardiac surgery, which participants found was immersive and useful. By proving the face validity and content validity of the CPVR-sim, we present the first step toward a cardiothoracic surgery VR training platform.
- 2 March 2022
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 10 (1) , e30456
Open AccessVirtual Reality Simulation Training for Cardiopulmonary Resuscitation After Cardiac Surgery: Face and Content Validity Study
Background: Cardiac arrest after cardiac surgery commonly has a reversible cause, where emergency resternotomy is often required for treatment, as recommended by international guidelines. We have developed a virtual reality (VR) simulation for training of cardiopulmonary resuscitation (CPR) and emergency resternotomy procedures after cardiac surgery, the Cardiopulmonary Resuscitation Virtual Reality Simulator (CPVR-sim). Two fictive clinical scenarios were used: one case of pulseless electrical activity (PEA) and a combined case of PEA and ventricular fibrillation. In this prospective study, we researched the face validity and content validity of the CPVR-sim. Objective: We designed a prospective study to assess the feasibility and to establish the face and content validity of two clinical scenarios (shockable and nonshockable cardiac arrest) of the CPVR-sim partly divided into a group of novices and experts in performing CPR and emergency resternotomies in patients after cardiac surgery. Methods: Clinicians (staff cardiothoracic surgeons, physicians, surgical residents, nurse practitioners, and medical students) participated in this study and performed two different scenarios, either PEA or combined PEA and ventricular fibrillation. All participants (N=41) performed a simulation and completed the questionnaire rating the simulator’s usefulness, satisfaction, ease of use, effectiveness, and immersiveness to assess face validity and content validity. Results: Responses toward face validity and content validity were predominantly positive in both groups. Most participants in the PEA scenario (n=26, 87%) felt actively involved in the simulation, and 23 (77%) participants felt in charge of the situation. The participants thought it was easy to learn how to interact with the software (n=24, 80%) and thought that the software responded adequately (n=21, 70%). All 15 (100%) expert participants preferred VR training as an addition to conventional training. Moreover, 13 (87%) of the expert participants would recommend VR training to other colleagues, and 14 (93%) of the expert participants thought the CPVR-sim was a useful method to train for infrequent post–cardiac surgery emergencies requiring CPR. Additionally, 10 (91%) of the participants thought it was easy to move in the VR environment, and that the CPVR-sim responded adequately in this scenario. Conclusions: We developed a proof-of-concept VR simulation for CPR training with two scenarios of a patient after cardiac surgery, which participants found was immersive and useful. By proving the face validity and content validity of the CPVR-sim, we present the first step toward a cardiothoracic surgery VR training platform.
- Open Access
- 17 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Virtual Reality Simulation Training for Cardiopulmonary Resuscitation After Cardiac Surgery: Face and Content Validity Study (Preprint)
BACKGROUND Cardiac arrest after cardiac surgery commonly has a reversible cause, where emergency resternotomy is often required for treatment, as recommended by international guidelines. We have developed a virtual reality (VR) simulation for training of cardiopulmonary resuscitation (CPR) and emergency resternotomy procedures after cardiac surgery, the Cardiopulmonary Resuscitation Virtual Reality Simulator (CPVR-sim). Two fictive clinical scenarios were used: one case of pulseless electrical activity (PEA) and a combined case of PEA and ventricular fibrillation. In this prospective study, we researched the face validity and content validity of the CPVR-sim. OBJECTIVE We designed a prospective study to assess the feasibility and to establish the face and content validity of two clinical scenarios (shockable and nonshockable cardiac arrest) of the CPVR-sim partly divided into a group of novices and experts in performing CPR and emergency resternotomies in patients after cardiac surgery. METHODS Clinicians (staff cardiothoracic surgeons, physicians, surgical residents, nurse practitioners, and medical students) participated in this study and performed two different scenarios, either PEA or combined PEA and ventricular fibrillation. All participants (N=41) performed a simulation and completed the questionnaire rating the simulator’s usefulness, satisfaction, ease of use, effectiveness, and immersiveness to assess face validity and content validity. RESULTS Responses toward face validity and content validity were predominantly positive in both groups. Most participants in the PEA scenario (n=26, 87%) felt actively involved in the simulation, and 23 (77%) participants felt in charge of the situation. The participants thought it was easy to learn how to interact with the software (n=24, 80%) and thought that the software responded adequately (n=21, 70%). All 15 (100%) expert participants preferred VR training as an addition to conventional training. Moreover, 13 (87%) of the expert participants would recommend VR training to other colleagues, and 14 (93%) of the expert participants thought the CPVR-sim was a useful method to train for infrequent post–cardiac surgery emergencies requiring CPR. Additionally, 10 (91%) of the participants thought it was easy to move in the VR environment, and that the CPVR-sim responded adequately in this scenario. CONCLUSIONS We developed a proof-of-concept VR simulation for CPR training with two scenarios of a patient after cardiac surgery, which participants found was immersive and useful. By proving the face validity and content validity of the CPVR-sim, we present the first step toward a cardiothoracic surgery VR training platform.
- 17 May 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessVirtual Reality Simulation Training for Cardiopulmonary Resuscitation After Cardiac Surgery: Face and Content Validity Study (Preprint)
BACKGROUND Cardiac arrest after cardiac surgery commonly has a reversible cause, where emergency resternotomy is often required for treatment, as recommended by international guidelines. We have developed a virtual reality (VR) simulation for training of cardiopulmonary resuscitation (CPR) and emergency resternotomy procedures after cardiac surgery, the Cardiopulmonary Resuscitation Virtual Reality Simulator (CPVR-sim). Two fictive clinical scenarios were used: one case of pulseless electrical activity (PEA) and a combined case of PEA and ventricular fibrillation. In this prospective study, we researched the face validity and content validity of the CPVR-sim. OBJECTIVE We designed a prospective study to assess the feasibility and to establish the face and content validity of two clinical scenarios (shockable and nonshockable cardiac arrest) of the CPVR-sim partly divided into a group of novices and experts in performing CPR and emergency resternotomies in patients after cardiac surgery. METHODS Clinicians (staff cardiothoracic surgeons, physicians, surgical residents, nurse practitioners, and medical students) participated in this study and performed two different scenarios, either PEA or combined PEA and ventricular fibrillation. All participants (N=41) performed a simulation and completed the questionnaire rating the simulator’s usefulness, satisfaction, ease of use, effectiveness, and immersiveness to assess face validity and content validity. RESULTS Responses toward face validity and content validity were predominantly positive in both groups. Most participants in the PEA scenario (n=26, 87%) felt actively involved in the simulation, and 23 (77%) participants felt in charge of the situation. The participants thought it was easy to learn how to interact with the software (n=24, 80%) and thought that the software responded adequately (n=21, 70%). All 15 (100%) expert participants preferred VR training as an addition to conventional training. Moreover, 13 (87%) of the expert participants would recommend VR training to other colleagues, and 14 (93%) of the expert participants thought the CPVR-sim was a useful method to train for infrequent post–cardiac surgery emergencies requiring CPR. Additionally, 10 (91%) of the participants thought it was easy to move in the VR environment, and that the CPVR-sim responded adequately in this scenario. CONCLUSIONS We developed a proof-of-concept VR simulation for CPR training with two scenarios of a patient after cardiac surgery, which participants found was immersive and useful. By proving the face validity and content validity of the CPVR-sim, we present the first step toward a cardiothoracic surgery VR training platform.
- 1 February 2004
- Published by Society of Petroleum Engineers (SPE)
Differential Pressure Valve Incorporated With the Single-Trip Horizontal Gravel Pack and Selective Stimulation System Improves Sand Control for Extended Reach Wells
Proposal Most of the reservoirs located in the Campos Basin, deepwater and ultra-deepwater offshore Brazil are described as unconsolidated sandstone that require sand control on both producers and water injection wells. Horizontal Open Hole Gravel P
- 1 February 2004
- Published by Society of Petroleum Engineers (SPE)
Differential Pressure Valve Incorporated With the Single-Trip Horizontal Gravel Pack and Selective Stimulation System Improves Sand Control for Extended Reach Wells
Proposal Most of the reservoirs located in the Campos Basin, deepwater and ultra-deepwater offshore Brazil are described as unconsolidated sandstone that require sand control on both producers and water injection wells. Horizontal Open Hole Gravel P