Bilawal Nadeem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bilawal Nadeem has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Masood Azhar
King Edward Medical University, Lahore, House # 47-B, Fateh Town, Okara, Pakistan
3 shared publicationsMohammad Usman
King Edward Medical University Lahore, 5N King Edward Boys Hostel Link Mcleod Road Lahore, Pakistan
2 shared publicationsAbdelrhman Abumoawad
Department of Medicine, Boston Medical Center
1 shared publication- Ahmad Zain
Department of Internal Medicine, UCHealth Parkview Medical Center, Pueblo, CO
1 shared publication - Akhil Raj Anumolu
Andhra Medical College
1 shared publication - Ali Ahmed
Internal Medicine, Dow University of Health and Sciences, Karachi, Pakistan
1 shared publication
Latest Publications
- 4 May 2026
- Published by Taylor & Francis in Baylor University Medical Center Proceedings
- Vol. 39 (4) , 608-613
Endovascular management of symptomatic May-Thurner syndrome: real-world procedural approaches and outcomes
May-Thurner syndrome (MTS) is characterized by extrinsic venous compression by the arterial system in ilio-caval territory leading to venous stasis, a predisposition to deep vein thrombosis (DVT), and edema. Endovascular interventions have become the cornerstone of treatment for patients with symptomatic MTS. We evaluated the safety and outcomes of patients with MTS who underwent endovascular management at our tertiary care center. We included 19 patients with symptomatic MTS who underwent vascular interventional procedures. Data were extracted from electronic medical records. The study outcomes included procedural safety, the Villalta score, and venous patency during follow-up. All patients had left-sided DVT and 47.4% had predisposing factors. Seven patients underwent a single-stage procedure with mechanical thrombectomy with or without thrombolysis, and six received stents. Twelve underwent a two-stage procedure, including initial thrombectomy with or without thrombolysis, continuous infusion thrombolysis for several hours in between, and repeat thrombectomy with or without thrombolysis, angioplasty, and stenting at the end. The mean Villalta score was 0.8 ± 1.6, with 94% venous patency at a median follow-up of 6 months. Endovascular interventions achieved excellent short-term outcomes, including high procedural success, substantial symptom resolution, and near-complete venous patency. These findings underscore the importance of prompt diagnosis and appropriate management of patients with symptomatic MTS.
- 4 May 2026
- Published by Taylor & Francis in Baylor University Medical Center Proceedings
- Vol. 39 (4) , 608-613
Endovascular management of symptomatic May-Thurner syndrome: real-world procedural approaches and outcomes
May-Thurner syndrome (MTS) is characterized by extrinsic venous compression by the arterial system in ilio-caval territory leading to venous stasis, a predisposition to deep vein thrombosis (DVT), and edema. Endovascular interventions have become the cornerstone of treatment for patients with symptomatic MTS. We evaluated the safety and outcomes of patients with MTS who underwent endovascular management at our tertiary care center. We included 19 patients with symptomatic MTS who underwent vascular interventional procedures. Data were extracted from electronic medical records. The study outcomes included procedural safety, the Villalta score, and venous patency during follow-up. All patients had left-sided DVT and 47.4% had predisposing factors. Seven patients underwent a single-stage procedure with mechanical thrombectomy with or without thrombolysis, and six received stents. Twelve underwent a two-stage procedure, including initial thrombectomy with or without thrombolysis, continuous infusion thrombolysis for several hours in between, and repeat thrombectomy with or without thrombolysis, angioplasty, and stenting at the end. The mean Villalta score was 0.8 ± 1.6, with 94% venous patency at a median follow-up of 6 months. Endovascular interventions achieved excellent short-term outcomes, including high procedural success, substantial symptom resolution, and near-complete venous patency. These findings underscore the importance of prompt diagnosis and appropriate management of patients with symptomatic MTS.
- 20 November 2025
- Published by SAGE Publications in Angiology
Carotid Artery Stent Fracture: A Comprehensive Literature Review With a Case Illustration
Carotid artery stenting (CAS) is an established alternative to endarterectomy, but stent fracture is an under-recognized complication with potential clinical consequences. We report a case of carotid stent fracture in a 69-year-old male with prior neck radiation, presenting with severe in-stent restenosis 10 months post-stenting. To place this case in context, a systematic review of PubMed, Embase, and Scopus (through June 2025) was conducted in line with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. Ten retrospective studies (2365 patients) were included. Stent fracture was identified in 172 patients, with a pooled prevalence of 7.3%. Type I and II fractures were most common, while Type V was rare. Reported risk factors included prior neck irradiation, vessel tortuosity, long stent length, and closed-cell stent design. Fluoroscopy was the most reliable detection method. Restenosis rates varied widely (0%-36%), most patients remained asymptomatic and were managed conservatively. In conclusion, Carotid stent fracture occurs in approximately 7% of cases and is often clinically silent, though it may predispose to restenosis. Surveillance and management should be individualized, with intervention reserved for symptomatic patients or progressive disease.
- 20 November 2025
- Published by SAGE Publications in Angiology
Carotid Artery Stent Fracture: A Comprehensive Literature Review With a Case Illustration
Carotid artery stenting (CAS) is an established alternative to endarterectomy, but stent fracture is an under-recognized complication with potential clinical consequences. We report a case of carotid stent fracture in a 69-year-old male with prior neck radiation, presenting with severe in-stent restenosis 10 months post-stenting. To place this case in context, a systematic review of PubMed, Embase, and Scopus (through June 2025) was conducted in line with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines. Ten retrospective studies (2365 patients) were included. Stent fracture was identified in 172 patients, with a pooled prevalence of 7.3%. Type I and II fractures were most common, while Type V was rare. Reported risk factors included prior neck irradiation, vessel tortuosity, long stent length, and closed-cell stent design. Fluoroscopy was the most reliable detection method. Restenosis rates varied widely (0%-36%), most patients remained asymptomatic and were managed conservatively. In conclusion, Carotid stent fracture occurs in approximately 7% of cases and is often clinically silent, though it may predispose to restenosis. Surveillance and management should be individualized, with intervention reserved for symptomatic patients or progressive disease.
- Open Access
- 9 May 2025
- Published by Elsevier in International Journal of Cardiology Cardiovascular Risk and Prevention
- Vol. 26, 200425
Three-decade analysis of regional disparities in metabolic risk factor related ischemic heart disease mortality: Contrasting trends between South Asia and North America
- 9 May 2025
- Published by Elsevier in International Journal of Cardiology Cardiovascular Risk and Prevention
- Vol. 26, 200425
Open AccessThree-decade analysis of regional disparities in metabolic risk factor related ischemic heart disease mortality: Contrasting trends between South Asia and North America
- 5 December 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- p. 1-7
Outcomes of concurrent and delayed leadless pacemaker implantation following extraction of infected cardiovascular implantable electronic device
Introduction The optimal reimplantation strategies following the removal of infected cardiovascular implantable electronic devices (CIEDs) remain inadequately understood. Given the limitations and risks associated with traditional approaches, the investigation of alternative devices, such as leadless pacemakers (LPs), has gained attention due to their potentially lower infection risk. Methods We reviewed literature sources including PubMed, Scopus, and Embase, utilizing a combination of search terms. The inclusion criterion was leadless pacemaker (LP) implantation following lead removal (LR) of infected CIEDs, while the exclusion criterion was LR for noninfectious indications. Study endpoints encompassed patient outcomes during follow-up. Results Our literature review yielded 827 articles, of which 22 met the inclusion criteria, encompassing a cohort of 657 patients who underwent LR followed by LP implantation. A total of 295 (44.9%) patients underwent concurrent LP implantation during the LR procedure. The rest underwent delayed procedures, and the overall duration between LR of infected CIED and LP implantation was 4.32 ± 3.9 days. A total of 194 (29.5%) patients had systemic CIED infections, whereas 153 (23.3%) had isolated pocket infections. In our patient cohort, procedural complications were scarce. Over a mean follow-up period of 13.3 ± 9.4 months, pacemaker syndrome was observed in 4 patients (0.61%), and 3 patients (0.46%) experienced persistent or recurrent infections. Conclusion Our review finds both concurrent and delayed LP implantation after infected CIED extraction to be safe, with low reinfection rates and minimal complications. LPs could also serve as a bridge to CRT re-implantation minimizing the use of temporary pacing systems. Graphical Abstract
- 5 December 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- p. 1-7
Outcomes of concurrent and delayed leadless pacemaker implantation following extraction of infected cardiovascular implantable electronic device
Introduction The optimal reimplantation strategies following the removal of infected cardiovascular implantable electronic devices (CIEDs) remain inadequately understood. Given the limitations and risks associated with traditional approaches, the investigation of alternative devices, such as leadless pacemakers (LPs), has gained attention due to their potentially lower infection risk. Methods We reviewed literature sources including PubMed, Scopus, and Embase, utilizing a combination of search terms. The inclusion criterion was leadless pacemaker (LP) implantation following lead removal (LR) of infected CIEDs, while the exclusion criterion was LR for noninfectious indications. Study endpoints encompassed patient outcomes during follow-up. Results Our literature review yielded 827 articles, of which 22 met the inclusion criteria, encompassing a cohort of 657 patients who underwent LR followed by LP implantation. A total of 295 (44.9%) patients underwent concurrent LP implantation during the LR procedure. The rest underwent delayed procedures, and the overall duration between LR of infected CIED and LP implantation was 4.32 ± 3.9 days. A total of 194 (29.5%) patients had systemic CIED infections, whereas 153 (23.3%) had isolated pocket infections. In our patient cohort, procedural complications were scarce. Over a mean follow-up period of 13.3 ± 9.4 months, pacemaker syndrome was observed in 4 patients (0.61%), and 3 patients (0.46%) experienced persistent or recurrent infections. Conclusion Our review finds both concurrent and delayed LP implantation after infected CIED extraction to be safe, with low reinfection rates and minimal complications. LPs could also serve as a bridge to CRT re-implantation minimizing the use of temporary pacing systems. Graphical Abstract
- 1 August 2022
- Published by Elsevier in Diabetes & Metabolic Syndrome: Clinical Research & Reviews
- Vol. 16 (8) , 102588
Effects of testosterone therapy in adult males with hypogonadism and T2DM: A meta-analysis and systematic review
- 1 August 2022
- Published by Elsevier in Diabetes & Metabolic Syndrome: Clinical Research & Reviews
- Vol. 16 (8) , 102588
Effects of testosterone therapy in adult males with hypogonadism and T2DM: A meta-analysis and systematic review
- 17 May 2022
- Published by Elsevier in Heart & Lung
- Vol. 55, 169
Comment on “ Post-traumatic stress disorder symptoms after veno-arterial extracorporeal membrane oxygenator support”
- 17 May 2022
- Published by Elsevier in Heart & Lung
- Vol. 55, 169
Comment on “ Post-traumatic stress disorder symptoms after veno-arterial extracorporeal membrane oxygenator support”
- 29 April 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (8) , 2504
Letter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplasty
- 29 April 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (8) , 2504
Letter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplasty
- 22 April 2022
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 69 (11) , e29692
Comment on: Role of anticoagulation in the management of tumor thrombus: A 10‐year single‐center experience
- 22 April 2022
- Published by Wiley in Pediatric Blood & Cancer
- Vol. 69 (11) , e29692
Comment on: Role of anticoagulation in the management of tumor thrombus: A 10‐year single‐center experience
- Open Access
- 18 April 2022
- Published by Wiley
Letter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplasty
TITLE PAGE Title: Letter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplastyArticle type: Letter to the editorCorrespondence : 1. Bilawal NadeemContact: +92-3137562580 Email: bilawal.ranjha@gmail.comInstitute: King Edward Medical University, LahoreAddress: Mianwal Ranjha Dera Allah Wadhaya Tehsil and District Mandi Bahauddin, 50400Words count: 418Conflict of interest: noneDisclosure: noneFunding: none
- 18 April 2022
- Published by Wiley
Open AccessLetter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplasty
TITLE PAGE Title: Letter to the Editor: Minimally invasive aortic valve repair using geometric ring annuloplastyArticle type: Letter to the editorCorrespondence : 1. Bilawal NadeemContact: +92-3137562580 Email: bilawal.ranjha@gmail.comInstitute: King Edward Medical University, LahoreAddress: Mianwal Ranjha Dera Allah Wadhaya Tehsil and District Mandi Bahauddin, 50400Words count: 418Conflict of interest: noneDisclosure: noneFunding: none
- 11 March 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (6) , 1808
Letter to the Editor: Utilization and outcomes of postcardiotomy mechanical circulatory support
- 11 March 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (6) , 1808
Letter to the Editor: Utilization and outcomes of postcardiotomy mechanical circulatory support