Shi-Qi Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shi-Qi Liu has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Zeng-Guang Hou
University of Chinese Academy of Sciences
34 shared publications - Xiao-Hu Zhou
Institute of Automation, Chinese Academy of Sciences
30 shared publications - Xiao-Liang Xie
Institute of Automation, Chinese Academy of Sciences
28 shared publications - Mei-Jiang Gui
Institute of Automation, State Key Laboratory of Multimodal Artificial Intelligence Systems, Chinese Academy of Sciences, Beijing, China
11 shared publications - Hao Li
State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, China
9 shared publications - Tian-Yu Xiang
State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, China
9 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (5) , 3626-3638
CROP: Conservative Reward for Model-Based Offline Policy Optimization
Offline reinforcement learning (RL) aims to optimize a policy using collected data without online interactions. Model-based approaches are particularly appealing for addressing offline RL challenges because of their capability to mitigate the limitations of data coverage through data generation using models. Nonetheless, a prevalent issue in offline RL is the overestimation caused by distribution shift. This study proposes a novel model-based offline RL algorithm named Conservative Reward for model-based Offline Policy optimization (CROP). CROP introduces a streamlined objective that concurrently minimizes estimation error and the rewards of random actions, thereby yielding a robustly conservative reward estimator. Theoretical analysis shows that the designed conservative reward mechanism leads to a conservative policy evaluation and mitigates distribution shift. Experiments showcase that with the simple modification to reward estimation, CROP can conservatively estimate the reward and achieve competitive performance with existing methods. The source code will be available after acceptance.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Emerging Topics in Computational Intelligence
- Vol. 10 (5) , 3626-3638
CROP: Conservative Reward for Model-Based Offline Policy Optimization
Offline reinforcement learning (RL) aims to optimize a policy using collected data without online interactions. Model-based approaches are particularly appealing for addressing offline RL challenges because of their capability to mitigate the limitations of data coverage through data generation using models. Nonetheless, a prevalent issue in offline RL is the overestimation caused by distribution shift. This study proposes a novel model-based offline RL algorithm named Conservative Reward for model-based Offline Policy optimization (CROP). CROP introduces a streamlined objective that concurrently minimizes estimation error and the rewards of random actions, thereby yielding a robustly conservative reward estimator. Theoretical analysis shows that the designed conservative reward mechanism leads to a conservative policy evaluation and mitigates distribution shift. Experiments showcase that with the simple modification to reward estimation, CROP can conservatively estimate the reward and achieve competitive performance with existing methods. The source code will be available after acceptance.
- Open Access
- 7 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 964
Robot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis
- 7 September 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 964
Open AccessRobot-assisted versus manual percutaneous vascular interventions across vascular territories: a systematic review and meta-analysis
- Open Access
- 19 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 854
Global trends and emerging frontiers in robot-assisted vascular intervention: a comprehensive bibliometric analysis
- 19 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 854
Open AccessGlobal trends and emerging frontiers in robot-assisted vascular intervention: a comprehensive bibliometric analysis
- Open Access
- 11 July 2026
- Published by Springer Nature in Systematic Reviews
- Vol. 15 (1)
Do robot-assisted percutaneous vascular interventions improve effectiveness and safety compared with manual procedures: protocol for a systematic review and meta-analysis
Robot-assisted percutaneous vascular interventions have emerged as a promising technology across cardiovascular, neurovascular, and peripheral vascular pro
- 11 July 2026
- Published by Springer Nature in Systematic Reviews
- Vol. 15 (1)
Open AccessDo robot-assisted percutaneous vascular interventions improve effectiveness and safety compared with manual procedures: protocol for a systematic review and meta-analysis
Robot-assisted percutaneous vascular interventions have emerged as a promising technology across cardiovascular, neurovascular, and peripheral vascular pro
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Manipulation Degree: A Novel Metric to Evaluate the Maneuverability of Magnetic Guidewires
Maneuverability is a critical factor in the clinical advantages of magnetic guidewires (magwires) for minimally invasive vascular interventions. However, the absence of standardized evaluation metrics often results in inconsistent or subjective assessments. This study proposes the Manipulation Degree, a novel metric that quantitatively evaluates maneuver-ability of magwires in an objective and standardized manner. The Manipulation Degree is defined by two key factors: the workspace area, which is the total surface area reachable by the magwires tip, and instability. It exhibits a positive correlation with workspace area and a negative correlation with instability, offering a concise evaluation framework. Experimental validation using three representative magwires demonstrates that increasing the number of magnetic segments and decreasing the magwire’s diameter increase the Manipulation Degree. Furthermore, magwires exhibiting a high Manipulation Degree in less constrained scenarios maintain this advantage in highly constrained scenarios. A strong linear correlation (R2 ≥ 0.99) is also observed between the Manipulation Degree and both delivery time and translation force, highlighting its predictive value for clinical performance. These findings establish the Manipulation Degree as a robust and practical metric for assessing the maneuverability of magwires, offering insights for the design optimization of magwires.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. PP (3) , 1
Manipulation Degree: A Novel Metric to Evaluate the Maneuverability of Magnetic Guidewires
Maneuverability is a critical factor in the clinical advantages of magnetic guidewires (magwires) for minimally invasive vascular interventions. However, the absence of standardized evaluation metrics often results in inconsistent or subjective assessments. This study proposes the Manipulation Degree, a novel metric that quantitatively evaluates maneuver-ability of magwires in an objective and standardized manner. The Manipulation Degree is defined by two key factors: the workspace area, which is the total surface area reachable by the magwires tip, and instability. It exhibits a positive correlation with workspace area and a negative correlation with instability, offering a concise evaluation framework. Experimental validation using three representative magwires demonstrates that increasing the number of magnetic segments and decreasing the magwire’s diameter increase the Manipulation Degree. Furthermore, magwires exhibiting a high Manipulation Degree in less constrained scenarios maintain this advantage in highly constrained scenarios. A strong linear correlation (R2 ≥ 0.99) is also observed between the Manipulation Degree and both delivery time and translation force, highlighting its predictive value for clinical performance. These findings establish the Manipulation Degree as a robust and practical metric for assessing the maneuverability of magwires, offering insights for the design optimization of magwires.
- 1 June 2026
- Published by Springer Nature
- p. 143-162
Video Segmentation of Deformable Instruments in Ultrasound-Guided Interventional Surgeries for Structural Heart Diseases
- 1 June 2026
- Published by Springer Nature
- p. 143-162
Video Segmentation of Deformable Instruments in Ultrasound-Guided Interventional Surgeries for Structural Heart Diseases
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (9) , 1-16
A Language-enhanced Supervision-reduced Analysis Framework for Multi-branching Vessels
It is essential to quantitatively analyze coronary arterial angiography (CAG) images for coronary interventional procedures as they are the gold reference standard for assessing stenosis. However, mainstream methods cannot extract different vascular branches precisely due to inadequate annotated data by experts and difficulty in uniformly defining vascular branches. To address the issue, this paper presents a novel framework to analyze multi-branching vessels with simple annotation, which localizes the endpoints of the vascular branches first, and then extracts corresponding vessel segments based on the endpoints. Considering it is challenging for current image-based methods to distinguish sparse vessel keypoints, we propose a cross-modal Language-Enhanced Endpoint Detection (LEED) network to achieve better performance by providing linguistic knowledge obtained from clinicians. A medical term corpus is established to convert conversation contents to standard texts. Furthermore, we devise a Twin-Stream Vessel Segmentation (TS-Seg) algorithm to segment various vascular branches based on gray-level features and detected endpoints. Besides, clinicians are allowed to manually add new endpoints and apply the TS-Seg algorithm alone to analyze any variant vascular branch that has not been defined before. Extensive experiments on two in-house and one public datasets consistently demonstrate the effectiveness and superiority of the proposed framework. Moreover, comprehensive vessel analysis reports are provided based on clinical prior knowledge to assist in preoperative surgery planning and postoperative treatment assessment, showing great potential to improve the efficiency and accuracy of clinical workflow.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (9) , 1-16
A Language-enhanced Supervision-reduced Analysis Framework for Multi-branching Vessels
It is essential to quantitatively analyze coronary arterial angiography (CAG) images for coronary interventional procedures as they are the gold reference standard for assessing stenosis. However, mainstream methods cannot extract different vascular branches precisely due to inadequate annotated data by experts and difficulty in uniformly defining vascular branches. To address the issue, this paper presents a novel framework to analyze multi-branching vessels with simple annotation, which localizes the endpoints of the vascular branches first, and then extracts corresponding vessel segments based on the endpoints. Considering it is challenging for current image-based methods to distinguish sparse vessel keypoints, we propose a cross-modal Language-Enhanced Endpoint Detection (LEED) network to achieve better performance by providing linguistic knowledge obtained from clinicians. A medical term corpus is established to convert conversation contents to standard texts. Furthermore, we devise a Twin-Stream Vessel Segmentation (TS-Seg) algorithm to segment various vascular branches based on gray-level features and detected endpoints. Besides, clinicians are allowed to manually add new endpoints and apply the TS-Seg algorithm alone to analyze any variant vascular branch that has not been defined before. Extensive experiments on two in-house and one public datasets consistently demonstrate the effectiveness and superiority of the proposed framework. Moreover, comprehensive vessel analysis reports are provided based on clinical prior knowledge to assist in preoperative surgery planning and postoperative treatment assessment, showing great potential to improve the efficiency and accuracy of clinical workflow.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Task-Oriented Learning for Automatic EEG Denoising
Electroencephalogram (EEG) denoising methods typically depend on manual intervention or clean reference signals. This work introduces a task-oriented learning framework for automatic EEG denoising with only task labels without clean reference signals. EEG recordings are first decomposed into components based on blind source separation (BSS) techniques. A learning-based selector then assigns a retention probability to each component, and the denoised signal is reconstructed as a probability-weighted combination. A downstream proxy-task model evaluates the reconstructed signal, with its task loss supervising the selector in a collaborative optimization scheme that relies solely on task labels, eliminating the need for clean EEG References. Experiments on three datasets, covering two paradigms and multiple noise conditions, demonstrate average gains of 2.59% in task accuracy and 0.80 dB in the signal-to-noise ratio (SNR) under standard signal-quality metrics. Further analyses demonstrate that the task-oriented learning framework is algorithm-agnostic, as it accommodates diverse decomposition techniques and network backbones for both the selector and the proxy model. These results indicate the proposed framework can denoise EEG using only task labels, supporting its potential utility in neuroscience research and EEG-based interaction systems.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-15
Task-Oriented Learning for Automatic EEG Denoising
Electroencephalogram (EEG) denoising methods typically depend on manual intervention or clean reference signals. This work introduces a task-oriented learning framework for automatic EEG denoising with only task labels without clean reference signals. EEG recordings are first decomposed into components based on blind source separation (BSS) techniques. A learning-based selector then assigns a retention probability to each component, and the denoised signal is reconstructed as a probability-weighted combination. A downstream proxy-task model evaluates the reconstructed signal, with its task loss supervising the selector in a collaborative optimization scheme that relies solely on task labels, eliminating the need for clean EEG References. Experiments on three datasets, covering two paradigms and multiple noise conditions, demonstrate average gains of 2.59% in task accuracy and 0.80 dB in the signal-to-noise ratio (SNR) under standard signal-quality metrics. Further analyses demonstrate that the task-oriented learning framework is algorithm-agnostic, as it accommodates diverse decomposition techniques and network backbones for both the selector and the proxy model. These results indicate the proposed framework can denoise EEG using only task labels, supporting its potential utility in neuroscience research and EEG-based interaction systems.