Wenjie Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wenjie Li has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Jie Xu
Key Laboratory of Advanced Micro-structured Materials, Ministry of Education, Tongji University 4 , Shanghai 200092
6 shared publications Baozhong Mu
5 shared publicationsLiang Chen
5 shared publicationsXin Wang
5 shared publicationsMingtao Li
4 shared publicationsXing Zhang
China Academy of Engineering Physics
4 shared publications
Latest Publications
- 23 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (9) , 16366-16382
Monte Carlo investigation of spatiotemporal distortions in attosecond soft X-ray pulse focusing using a two-stage toroidal mirror system
Attosecond soft X-ray pulses provide excellent temporal and spatial coherence, enabling ultrafast probing of electronic and structural dynamics. Fully exploiting their capabilities requires high demagnification to achieve the necessary power density, but such conditions induce strong spatiotemporal coupling distortions. In this work, we develop a Geant4-based Monte Carlo framework for quantitatively evaluating these distortions during attosecond soft X-ray focusing. Aberration-theory analysis and simulations of a single toroidal mirror reveal that coma increases rapidly with the demagnification ratio, fundamentally limiting single-stage performance. To overcome this constraint, we propose a two-stage toroidal focusing architecture. Using analytically derived structural parameters as initial conditions, the system is numerically optimized within Geant4. The final design achieves a demagnification of 15.5×, producing a focal-spot full width at half maximum (FWHM) of 14.4 μm, while reducing temporal broadening within the spatial FWHM to 153.0 as peak-to-valley (PV) and 18.0 as root-mean-square (RMS). To enhance practical relevance, we further incorporate independent meridional and sagittal slope errors for both toroidal mirrors and quantify the resulting degradations of spatial focusing and temporal broadening. These results demonstrate that the two-stage configuration effectively suppresses coma and minimizes spatiotemporal distortions, providing a robust approach for high-precision attosecond soft X-ray beamline development.
- 23 April 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (9) , 16366-16382
Monte Carlo investigation of spatiotemporal distortions in attosecond soft X-ray pulse focusing using a two-stage toroidal mirror system
Attosecond soft X-ray pulses provide excellent temporal and spatial coherence, enabling ultrafast probing of electronic and structural dynamics. Fully exploiting their capabilities requires high demagnification to achieve the necessary power density, but such conditions induce strong spatiotemporal coupling distortions. In this work, we develop a Geant4-based Monte Carlo framework for quantitatively evaluating these distortions during attosecond soft X-ray focusing. Aberration-theory analysis and simulations of a single toroidal mirror reveal that coma increases rapidly with the demagnification ratio, fundamentally limiting single-stage performance. To overcome this constraint, we propose a two-stage toroidal focusing architecture. Using analytically derived structural parameters as initial conditions, the system is numerically optimized within Geant4. The final design achieves a demagnification of 15.5×, producing a focal-spot full width at half maximum (FWHM) of 14.4 μm, while reducing temporal broadening within the spatial FWHM to 153.0 as peak-to-valley (PV) and 18.0 as root-mean-square (RMS). To enhance practical relevance, we further incorporate independent meridional and sagittal slope errors for both toroidal mirrors and quantify the resulting degradations of spatial focusing and temporal broadening. These results demonstrate that the two-stage configuration effectively suppresses coma and minimizes spatiotemporal distortions, providing a robust approach for high-precision attosecond soft X-ray beamline development.
- 3 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (13) , 22181-22193
Development of a four-color quasimonochromatic X-ray microscope for laser plasma research
X-ray multicolor imaging diagnosis obtains the spatial distribution of the imploding core during laser inertial confinement fusion. We propose a four-color quasimonochromatic X-ray microscope based on the Kirkpatrick–Baez microscope configuration, covering the medium-to-high-energy X-ray range. Composed of single-layer film mirrors and periodic multilayer film mirrors, the microscope features high spatial resolution and spectral resolution. Furthermore, zoned coating technology achieves common field-of-view (FOV) imaging at four energy points: 4.51, 6.4, 8.4, and 9.67 keV. When assembled and calibrated in the laboratory, the microscope achieved central FOV spatial resolutions of 3.9, 3.7, 4.0, and 4.1 µm at 4.51, 6.4, 8.04, and 9.67 keV, respectively. Finally, a spectral calibration experiment confirmed spectral selectivity at the four energy points.
- 3 June 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (13) , 22181-22193
Development of a four-color quasimonochromatic X-ray microscope for laser plasma research
X-ray multicolor imaging diagnosis obtains the spatial distribution of the imploding core during laser inertial confinement fusion. We propose a four-color quasimonochromatic X-ray microscope based on the Kirkpatrick–Baez microscope configuration, covering the medium-to-high-energy X-ray range. Composed of single-layer film mirrors and periodic multilayer film mirrors, the microscope features high spatial resolution and spectral resolution. Furthermore, zoned coating technology achieves common field-of-view (FOV) imaging at four energy points: 4.51, 6.4, 8.4, and 9.67 keV. When assembled and calibrated in the laboratory, the microscope achieved central FOV spatial resolutions of 3.9, 3.7, 4.0, and 4.1 µm at 4.51, 6.4, 8.04, and 9.67 keV, respectively. Finally, a spectral calibration experiment confirmed spectral selectivity at the four energy points.
- 9 October 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (22) , 35453-35470
Monte Carlo study of X-ray grazing incidence microscopy using Geant4
X-ray grazing incidence microscopy has extensive applications in the fields of laser inertial confinement fusion and synchrotron radiation. Monte Carlo methods can be used to determine the optical performance of X-ray grazing incidence microscopes and predict the experimental results, which is of great significance for studying physical experiments and diagnostics. In this paper, we proposed a Monte Carlo method based on Geant4 for studying X-ray grazing incidence microscopy. We introduced the G4MultilayerReflection class to describe the physical processes of X-ray multilayer mirrors. We designed a dual-energy Kirkpatrick–Baez microscope that can operate at 6.4 and 9.67 keV simultaneously. Monte Carlo simulations of the spatial resolution and throughput efficiency of the microscope were performed using Geant4, which was assembled and characterized. The spatial resolution results obtained by the Geant4 laboratory simulations, the theoretical model, and the experiments were in good agreement. Additionally, we conducted throughput efficiency calibration experiments for the 6.4 keV imaging channel. The difference between the experimental and Geant4-simulated throughput efficiency was evaluated and resulted in root mean square error values of 8.7% and 9.5% along the Y- and Z-axes, respectively.
- 9 October 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (22) , 35453-35470
Monte Carlo study of X-ray grazing incidence microscopy using Geant4
X-ray grazing incidence microscopy has extensive applications in the fields of laser inertial confinement fusion and synchrotron radiation. Monte Carlo methods can be used to determine the optical performance of X-ray grazing incidence microscopes and predict the experimental results, which is of great significance for studying physical experiments and diagnostics. In this paper, we proposed a Monte Carlo method based on Geant4 for studying X-ray grazing incidence microscopy. We introduced the G4MultilayerReflection class to describe the physical processes of X-ray multilayer mirrors. We designed a dual-energy Kirkpatrick–Baez microscope that can operate at 6.4 and 9.67 keV simultaneously. Monte Carlo simulations of the spatial resolution and throughput efficiency of the microscope were performed using Geant4, which was assembled and characterized. The spatial resolution results obtained by the Geant4 laboratory simulations, the theoretical model, and the experiments were in good agreement. Additionally, we conducted throughput efficiency calibration experiments for the 6.4 keV imaging channel. The difference between the experimental and Geant4-simulated throughput efficiency was evaluated and resulted in root mean square error values of 8.7% and 9.5% along the Y- and Z-axes, respectively.
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (05) , 055103-9
Study on full-aperture intensity response measurement for x-ray Kirkpatrick–Baez microscope
The diagnostic demand of hot-spot intensity distribution in laser inertial confinement fusion experiment has motivated quantitative measurement experiment to give the response efficiency of grazing incidence system to improve the accuracy of the diagnosis. In our study, a full-aperture intensity response measurement method is proposed, which is based on pinhole-scanning field of view (FOV) to obtain the response efficiency of grazing incidence system. The method is highly repeatable and enables response efficiency measurements over the full FOV with acceptable accuracy. A silicon positive-intrinsic-negative detector with an energy response range of 1.5 to 30 keV is used to directly detect the input and output spectrum. The response efficiency of a single-channel aspheric Kirkpatrick–Baez (KB) microscope coated with W/Si is obtained under the FOV of ±150 μm. The response efficiency of center FOV of the KB system is measured to be 2.52E-7 sr. The value is promising, as it shows a 6.6% maximum deviation from the theoretical value at center FOV, with a global uncertainty of 7.4%.
- 1 May 2023
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 62 (05) , 055103-9
Study on full-aperture intensity response measurement for x-ray Kirkpatrick–Baez microscope
The diagnostic demand of hot-spot intensity distribution in laser inertial confinement fusion experiment has motivated quantitative measurement experiment to give the response efficiency of grazing incidence system to improve the accuracy of the diagnosis. In our study, a full-aperture intensity response measurement method is proposed, which is based on pinhole-scanning field of view (FOV) to obtain the response efficiency of grazing incidence system. The method is highly repeatable and enables response efficiency measurements over the full FOV with acceptable accuracy. A silicon positive-intrinsic-negative detector with an energy response range of 1.5 to 30 keV is used to directly detect the input and output spectrum. The response efficiency of a single-channel aspheric Kirkpatrick–Baez (KB) microscope coated with W/Si is obtained under the FOV of ±150 μm. The response efficiency of center FOV of the KB system is measured to be 2.52E-7 sr. The value is promising, as it shows a 6.6% maximum deviation from the theoretical value at center FOV, with a global uncertainty of 7.4%.
- 1 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45792-45806
Compact multichannel spectrometer employed for soft x-ray spectrum diagnostics at the Shenguang-III Laser Facility
The quantitative measurement of plasma soft x-ray spectra is an important diagnostic problem in indirect-drive laser inertial confinement fusion (ICF). We designed, built, and tested a compact multichannel soft x-ray spectrometer with both spatial and temporal resolution capabilities for the detection of the spatiotemporal distribution of soft x-ray spectra. The spectrometer occupies a small solid angle, and the close measurement angle used for each channel enables the measurement of the angular distribution of emitting soft x-rays in ICF experiments. The spectrometer comprises pinhole, filter, and multilayer flat mirror arrays, and an x-ray streak camera. Its energy range is 0.1 – 3 keV. The dispersive elements of the spectrometer were calibrated at the Beijing Synchrotron Radiation Facility. The accuracy of the calibration was ≤ 5%, and the combined energy resolution (E/ΔE) of the calibrated dispersive elements of each channel was higher than 10. Finally, the instrument was tested at the Shenguang-III Laser Facility. The measurement results of x-ray radiation flux are agreed well with the experimental results of the M-band flat-response x-ray diode, demonstrating the feasibility of the proposed spectrometer configuration.
- 1 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45792-45806
Compact multichannel spectrometer employed for soft x-ray spectrum diagnostics at the Shenguang-III Laser Facility
The quantitative measurement of plasma soft x-ray spectra is an important diagnostic problem in indirect-drive laser inertial confinement fusion (ICF). We designed, built, and tested a compact multichannel soft x-ray spectrometer with both spatial and temporal resolution capabilities for the detection of the spatiotemporal distribution of soft x-ray spectra. The spectrometer occupies a small solid angle, and the close measurement angle used for each channel enables the measurement of the angular distribution of emitting soft x-rays in ICF experiments. The spectrometer comprises pinhole, filter, and multilayer flat mirror arrays, and an x-ray streak camera. Its energy range is 0.1 – 3 keV. The dispersive elements of the spectrometer were calibrated at the Beijing Synchrotron Radiation Facility. The accuracy of the calibration was ≤ 5%, and the combined energy resolution (E/ΔE) of the calibrated dispersive elements of each channel was higher than 10. Finally, the instrument was tested at the Shenguang-III Laser Facility. The measurement results of x-ray radiation flux are agreed well with the experimental results of the M-band flat-response x-ray diode, demonstrating the feasibility of the proposed spectrometer configuration.
- 8 July 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (15) , 26761-26773
High-resolution elliptical Kirkpatrick–Baez microscope for implosion higher-mode instability diagnosis
High-resolution X-ray imaging diagnosis is a critical method for measuring Rayleigh-Taylor instability growth and hot spot interface morphology in inertial confinement fusion experiments. In this study, we develop a quasi-monochromatic elliptical Kirkpatrick–Baez microscope based on aberration theory, breaking the aberration limit of conventional Kirkpatrick–Baez microscopes. The microscope was characterized in the laboratory for spatial resolution performance and modulation transfer function before being implemented in cavity experiments at the SG-III prototype laser facility. The results demonstrate that the edge-based method achieves a spatial resolution of 20%.
- 8 July 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (15) , 26761-26773
High-resolution elliptical Kirkpatrick–Baez microscope for implosion higher-mode instability diagnosis
High-resolution X-ray imaging diagnosis is a critical method for measuring Rayleigh-Taylor instability growth and hot spot interface morphology in inertial confinement fusion experiments. In this study, we develop a quasi-monochromatic elliptical Kirkpatrick–Baez microscope based on aberration theory, breaking the aberration limit of conventional Kirkpatrick–Baez microscopes. The microscope was characterized in the laboratory for spatial resolution performance and modulation transfer function before being implemented in cavity experiments at the SG-III prototype laser facility. The results demonstrate that the edge-based method achieves a spatial resolution of 20%.
- 1 March 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (6) , 8777-8793
Development of a quasi-coaxis dual-energy flat spectral response X-ray imaging instrument for measuring hotspot electron temperature
The measurement of hotspot electron temperature is a paramount technique of implosion physics research in inertial confinement fusion. This study proposes a novel quasi-coaxis dual-energy flat spectral response high-resolution X-ray imaging instrument comprising a dual-channel total-reflection Kirkpatrick-Baez microscope and two flat non-periodic multilayer mirrors, which can image at 6.4 ± 0.5 and 9.67 ± 0.5 keV simultaneously. Various theoretical simulations were performed to verify the performance and feasibility of the imaging instrument, which was assembled and characterized in a laboratory. Experimental results show that the imaging instrument could achieve a high spatial resolution of 5 µm in a ± 150 µm field of view (FOV), the root mean square(RMS) deviation values of the measured reflection efficiency are 1.71% and 1.82% for the 6.4 keV and 9.67 keV imaging channels, respectively, in the ± 150 µm FOV.
- 1 March 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (6) , 8777-8793
Development of a quasi-coaxis dual-energy flat spectral response X-ray imaging instrument for measuring hotspot electron temperature
The measurement of hotspot electron temperature is a paramount technique of implosion physics research in inertial confinement fusion. This study proposes a novel quasi-coaxis dual-energy flat spectral response high-resolution X-ray imaging instrument comprising a dual-channel total-reflection Kirkpatrick-Baez microscope and two flat non-periodic multilayer mirrors, which can image at 6.4 ± 0.5 and 9.67 ± 0.5 keV simultaneously. Various theoretical simulations were performed to verify the performance and feasibility of the imaging instrument, which was assembled and characterized in a laboratory. Experimental results show that the imaging instrument could achieve a high spatial resolution of 5 µm in a ± 150 µm field of view (FOV), the root mean square(RMS) deviation values of the measured reflection efficiency are 1.71% and 1.82% for the 6.4 keV and 9.67 keV imaging channels, respectively, in the ± 150 µm FOV.
- 7 November 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 662-666
Quantitative 3D imaging of yeast by hard X‐ray tomography
Full‐field hard X‐ray tomography could be used to obtain three‐dimensional (3D) nanoscale structures of biological samples. The image of the fission yeast, Schizosaccharomyces pombe, was clearly visualized based on Zernike phase contrast imaging technique and heavy metal staining method at a spatial resolution better than 50 nm at the energy of 8 keV. The distributions and shapes of the organelles during the cell cycle were clearly visualized and two types of organelle were distinguished. The results for cells during various phases were compared and the ratios of organelle volume to cell volume can be analyzed quantitatively. It showed that the ratios remained constant between growth and division phase and increased strongly in stationary phase, following the shape and size of two types of organelles changes. Our results demonstrated that hard X‐ray microscopy was a complementary method for imaging and revealing structural information for biological samples. Microsc. Res. Tech., 2012.
- 7 November 2011
- Published by Wiley in Microscopy Research and Technique
- Vol. 75 (5) , 662-666
Quantitative 3D imaging of yeast by hard X‐ray tomography
Full‐field hard X‐ray tomography could be used to obtain three‐dimensional (3D) nanoscale structures of biological samples. The image of the fission yeast, Schizosaccharomyces pombe, was clearly visualized based on Zernike phase contrast imaging technique and heavy metal staining method at a spatial resolution better than 50 nm at the energy of 8 keV. The distributions and shapes of the organelles during the cell cycle were clearly visualized and two types of organelle were distinguished. The results for cells during various phases were compared and the ratios of organelle volume to cell volume can be analyzed quantitatively. It showed that the ratios remained constant between growth and division phase and increased strongly in stationary phase, following the shape and size of two types of organelles changes. Our results demonstrated that hard X‐ray microscopy was a complementary method for imaging and revealing structural information for biological samples. Microsc. Res. Tech., 2012.
- Open Access
- 1 October 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (6) , 782-785
The study of the reconstructed three-dimensional structure of a solid-oxide fuel-cell cathode by X-ray nanotomography
The microstructure and morphology of solid-oxide fuel-cell electrodes are very complex but important because they strongly affect the electrical performance of the cell. In this work the high-resolution X-ray nanotomography technique is applied to reconstruct the three-dimensional microstructure of a (La(0.8)Sr(0.2))(0.95)MnO(3) yttria-stabilized zirconia composite cathode. Some key microstructural parameters, such as the porosity, representative elementary volume, connected pore volume and pore phase tortuosity, were obtained based on the three-dimensional reconstruction volume data with a spatial resolution of sub-60 nm. These parameters bear intimate correlation with the efficiency of the electrochemical conversion process, and provide valuable information for optimizing the manufacturing processes and improving the device's reliability.
- 1 October 2010
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (6) , 782-785
Open AccessThe study of the reconstructed three-dimensional structure of a solid-oxide fuel-cell cathode by X-ray nanotomography
The microstructure and morphology of solid-oxide fuel-cell electrodes are very complex but important because they strongly affect the electrical performance of the cell. In this work the high-resolution X-ray nanotomography technique is applied to reconstruct the three-dimensional microstructure of a (La(0.8)Sr(0.2))(0.95)MnO(3) yttria-stabilized zirconia composite cathode. Some key microstructural parameters, such as the porosity, representative elementary volume, connected pore volume and pore phase tortuosity, were obtained based on the three-dimensional reconstruction volume data with a spatial resolution of sub-60 nm. These parameters bear intimate correlation with the efficiency of the electrochemical conversion process, and provide valuable information for optimizing the manufacturing processes and improving the device's reliability.