Huaiwu He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Huaiwu He has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Yi Chi
State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
5 shared publications- Yun Long
Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
4 shared publications Inéz Frerichs
Department of Anesthesiology and Intensive Care Medicine, University Medical Center of Schleswig-Holstein, Kiel, Germany
3 shared publicationsYun Long
State Key Laboratory of Complex Severe and Rare Disease, Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
3 shared publicationsZhanqi Zhao
Department of Biomedical Engineering, Fourth Military Medical University, Xi’an, China
3 shared publications- Zhanqi Zhao
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
3 shared publications
Latest Publications
- Open Access
- 1 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (11) , 1407-1408
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity
- 1 June 2024
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 209 (11) , 1407-1408
Open AccessVentilator Waveforms May Give Clues to Expiratory Muscle Activity
- Open Access
Multicentre, parallel, open-label, two-arm, randomised controlled trial on the prognosis of electrical impedance tomography-guided versus low PEEP/FiO2 table-guided PEEP setting: a trial protocol
Introduction: Previous studies suggested that electrical impedance tomography (EIT) has the potential to guide positive end-expiratory pressure (PEEP) titration via quantifying the alveolar collapse and overdistension. The aim of this trial is to compare the effect of EIT-guided PEEP and acute respiratory distress syndrome (ARDS) network low PEEP/fraction of inspired oxygen (FiO 2 ) table strategy on mortality and other clinical outcomes in patients with ARDS. Methods: This is a parallel, two-arm, multicentre, randomised, controlled trial, conducted in China. All patients with ARDS under mechanical ventilation admitted to the intensive care unit will be screened for eligibility. The enrolled patients are stratified by the aetiology (pulmonary/extrapulmonary) and partial pressure of arterial oxygen/FiO 2 (≥150 mm Hg or 2 table proposed by the ARDS Network. The primary outcome is 28-day survival. Analysis: Qualitative data will be analysed using the χ 2 test or Fisher’s exact test, quantitative data will be analysed using independent samples t-test or Mann-Whitney U test. Kaplan-Meier analysis with log-rank test will be used to evaluate the 28-day survival rate between two groups. All outcomes will be analysed based on the intention-to-treat principle. Ethics and dissemination: The trial is approved by the Institutional Research and Ethics Committee of the Peking Union Medical College Hospital. Data will be published in peer-reviewed journals. Trial registration number: NCT05307913 .
Open AccessMulticentre, parallel, open-label, two-arm, randomised controlled trial on the prognosis of electrical impedance tomography-guided versus low PEEP/FiO2 table-guided PEEP setting: a trial protocol
Introduction: Previous studies suggested that electrical impedance tomography (EIT) has the potential to guide positive end-expiratory pressure (PEEP) titration via quantifying the alveolar collapse and overdistension. The aim of this trial is to compare the effect of EIT-guided PEEP and acute respiratory distress syndrome (ARDS) network low PEEP/fraction of inspired oxygen (FiO 2 ) table strategy on mortality and other clinical outcomes in patients with ARDS. Methods: This is a parallel, two-arm, multicentre, randomised, controlled trial, conducted in China. All patients with ARDS under mechanical ventilation admitted to the intensive care unit will be screened for eligibility. The enrolled patients are stratified by the aetiology (pulmonary/extrapulmonary) and partial pressure of arterial oxygen/FiO 2 (≥150 mm Hg or 2 table proposed by the ARDS Network. The primary outcome is 28-day survival. Analysis: Qualitative data will be analysed using the χ 2 test or Fisher’s exact test, quantitative data will be analysed using independent samples t-test or Mann-Whitney U test. Kaplan-Meier analysis with log-rank test will be used to evaluate the 28-day survival rate between two groups. All outcomes will be analysed based on the intention-to-treat principle. Ethics and dissemination: The trial is approved by the Institutional Research and Ethics Committee of the Peking Union Medical College Hospital. Data will be published in peer-reviewed journals. Trial registration number: NCT05307913 .
- Open Access
- 17 November 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Two regional ventilation–perfusion patterns of lung consolidation assessed by electrical impedance tomography and ultrasound
- 17 November 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Open AccessTwo regional ventilation–perfusion patterns of lung consolidation assessed by electrical impedance tomography and ultrasound
- 4 November 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (2) , 629-637
Bedside electrical impedance tomography in early diagnosis of pneumothorax in mechanically ventilated ICU patients — a single-center retrospective cohort study
Purpose This study aimed to evaluate the routine use of electrical impedance tomography (EIT) to diagnose pneumothorax (PTX) in mechanically ventilated patients in the intensive care unit (ICU). Methods A retrospective cohort study was conducted including mechanically ventilated supine patients who received EIT examinations. The EIT-based tidal variation was divided into ventral and dorsal regions of interest (ROIs): upper right (UR, ROI1), upper left (UL, ROI2) lower right (LR, ROI3), and lower left (LL, ROI4), and the ventilation defect score (DS) was calculated in each quadrant. Furthermore, horizontal ventral ventilation index (HVVI) was defined as ROI1% / ROI2% in the two ventral quadrants if ROI1% > ROI2%, otherwise HVVI = ROI2% / ROI1%. Results A total of 203 patients were included, 25 of them with confirmed PTX. In the PTX patients, preceding cardiac surgery was the most common cause of PTX. Compared with the patients without PTX, the PTX patients had a higher DS in the ventral quadrants [median and interquartile range (IQR): 1.00 (0.00, 2.00) vs. 0.00 (0.00, 0.00), P < 0.001] respectively, but similar in the dorsal quadrants [median and IQR: 1.00 (0.00, 1.00) vs. 0.00 (0.00, 1.00), P = 0.722]. Moreover, a higher HVVI was found in the PTX group [median and IQR: 2.51 (1.58, 3.52) vs. 1.36 (1.15, 1.77), P < 0.001]. The area under the receiver operating characteristic curve of the HVVI to differentiate PTX from non-PTX was 0.88, with a sensitivity of 70% and a specificity of 90% when the cut-off value was 2.57. Conclusion The ventilation defect in the ventral regions and a high HVVI on EIT were observed in mechanically ventilated patients with PTX, which should trigger further diagnostics to confirm it.
- 4 November 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (2) , 629-637
Bedside electrical impedance tomography in early diagnosis of pneumothorax in mechanically ventilated ICU patients — a single-center retrospective cohort study
Purpose This study aimed to evaluate the routine use of electrical impedance tomography (EIT) to diagnose pneumothorax (PTX) in mechanically ventilated patients in the intensive care unit (ICU). Methods A retrospective cohort study was conducted including mechanically ventilated supine patients who received EIT examinations. The EIT-based tidal variation was divided into ventral and dorsal regions of interest (ROIs): upper right (UR, ROI1), upper left (UL, ROI2) lower right (LR, ROI3), and lower left (LL, ROI4), and the ventilation defect score (DS) was calculated in each quadrant. Furthermore, horizontal ventral ventilation index (HVVI) was defined as ROI1% / ROI2% in the two ventral quadrants if ROI1% > ROI2%, otherwise HVVI = ROI2% / ROI1%. Results A total of 203 patients were included, 25 of them with confirmed PTX. In the PTX patients, preceding cardiac surgery was the most common cause of PTX. Compared with the patients without PTX, the PTX patients had a higher DS in the ventral quadrants [median and interquartile range (IQR): 1.00 (0.00, 2.00) vs. 0.00 (0.00, 0.00), P < 0.001] respectively, but similar in the dorsal quadrants [median and IQR: 1.00 (0.00, 1.00) vs. 0.00 (0.00, 1.00), P = 0.722]. Moreover, a higher HVVI was found in the PTX group [median and IQR: 2.51 (1.58, 3.52) vs. 1.36 (1.15, 1.77), P < 0.001]. The area under the receiver operating characteristic curve of the HVVI to differentiate PTX from non-PTX was 0.88, with a sensitivity of 70% and a specificity of 90% when the cut-off value was 2.57. Conclusion The ventilation defect in the ventral regions and a high HVVI on EIT were observed in mechanically ventilated patients with PTX, which should trigger further diagnostics to confirm it.
- Open Access
- 18 July 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 973679
Editorial: Bedside visual image technologies for respiratory and circulatory management in intensive care settings
Editorial: Bedside visual image technologies for respiratory and circulatory management in intensive care settings
- 18 July 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 973679
Open AccessEditorial: Bedside visual image technologies for respiratory and circulatory management in intensive care settings
Editorial: Bedside visual image technologies for respiratory and circulatory management in intensive care settings
- Open Access
- 30 June 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 906302
Effect of Prone Positioning With Individualized Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome Using Electrical Impedance Tomography
Background: Positive end-expiratory pressure (PEEP) optimization during prone positioning remains under debate in acute respiratory distress syndrome (ARDS). This study aimed to investigate the effect of prone position on the optimal PEEP guided by electrical impedance tomography (EIT).Methods: We conducted a retrospective analysis on nineteen ARDS patients in a single intensive care unit. All patients underwent PEEP titration guided by EIT in both supine and prone positions. EIT-derived parameters, including center of ventilation (CoV), regional ventilation delay (RVD), percentage of overdistension (OD) and collapse (CL) were calculated. Optimal PEEP was defined as the PEEP level with minimal sum of OD and CL. Patients were divided into two groups: 1) Lower Optimal PEEPPP (LOP), where optimal PEEP was lower in the prone than in the supine position, and 2) Not-Lower Optimal PEEPPP (NLOP), where optimal PEEP was not lower in the prone compared with the supine position.Results: Eleven patients were classified as LOP (9 [8-9] vs. 12 [10-15] cmH2O; PEEP in prone vs. supine). In the NLOP group, optimal PEEP increased after prone positioning in four patients and remained unchanged in the other four patients. Patients in the LOP group had a significantly higher body mass index (26 [25-28] vs. 22 [17-25] kg/m2; p = 0.009) and lower ICU mortality (0/11 vs. 4/8; p = 0.018) compared with the NLOP group. Besides, PaO2/FiO2 increased significantly during prone positioning in the LOP group (238 [170-291] vs. 186 [141-195] mmHg; p = 0.042). CoV and RVD were also significantly improved during prone positioning in LOP group. No such effects were found in the NLOP group.Conclusion: Broad variability in optimal PEEP between supine and prone position was observed in the studied ARDS patients. Not all patients showed decreased optimal PEEP during prone positioning. Patients with higher body mass index exhibited lower optimal PEEP in prone position, better oxygenation and ventilation homogeneity.
- 30 June 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 906302
Open AccessEffect of Prone Positioning With Individualized Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome Using Electrical Impedance Tomography
Background: Positive end-expiratory pressure (PEEP) optimization during prone positioning remains under debate in acute respiratory distress syndrome (ARDS). This study aimed to investigate the effect of prone position on the optimal PEEP guided by electrical impedance tomography (EIT).Methods: We conducted a retrospective analysis on nineteen ARDS patients in a single intensive care unit. All patients underwent PEEP titration guided by EIT in both supine and prone positions. EIT-derived parameters, including center of ventilation (CoV), regional ventilation delay (RVD), percentage of overdistension (OD) and collapse (CL) were calculated. Optimal PEEP was defined as the PEEP level with minimal sum of OD and CL. Patients were divided into two groups: 1) Lower Optimal PEEPPP (LOP), where optimal PEEP was lower in the prone than in the supine position, and 2) Not-Lower Optimal PEEPPP (NLOP), where optimal PEEP was not lower in the prone compared with the supine position.Results: Eleven patients were classified as LOP (9 [8-9] vs. 12 [10-15] cmH2O; PEEP in prone vs. supine). In the NLOP group, optimal PEEP increased after prone positioning in four patients and remained unchanged in the other four patients. Patients in the LOP group had a significantly higher body mass index (26 [25-28] vs. 22 [17-25] kg/m2; p = 0.009) and lower ICU mortality (0/11 vs. 4/8; p = 0.018) compared with the NLOP group. Besides, PaO2/FiO2 increased significantly during prone positioning in the LOP group (238 [170-291] vs. 186 [141-195] mmHg; p = 0.042). CoV and RVD were also significantly improved during prone positioning in LOP group. No such effects were found in the NLOP group.Conclusion: Broad variability in optimal PEEP between supine and prone position was observed in the studied ARDS patients. Not all patients showed decreased optimal PEEP during prone positioning. Patients with higher body mass index exhibited lower optimal PEEP in prone position, better oxygenation and ventilation homogeneity.
- Open Access
- 5 March 2022
- Published by Elsevier in Annals of Intensive Care
- Vol. 12 (1) , 1-9
Prevalence and prognosis of respiratory pendelluft phenomenon in mechanically ventilated ICU patients with acute respiratory failure: a retrospective cohort study
- 5 March 2022
- Published by Elsevier in Annals of Intensive Care
- Vol. 12 (1) , 1-9
Open AccessPrevalence and prognosis of respiratory pendelluft phenomenon in mechanically ventilated ICU patients with acute respiratory failure: a retrospective cohort study