Aojie Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aojie Zhou has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jianming Zhu
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
2 shared publications - Junxiang Huang
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
2 shared publications - Yu Zhou
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
2 shared publications - Zhencheng Chen
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
2 shared publications - Qiong Gong
Key Laboratory of Automatic Detecting Technology and Instruments, School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication
Latest Publications
- Open Access
- 22 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4218
Detection of Sleep Apnea from Electrocardiogram and Pulse Oximetry Signals Using Random Forest
Sleep apnea (SA) is a common sleep disorder which could impair the human physiological system. Therefore, early diagnosis of SA is of great interest. The traditional method of diagnosing SA is an overnight polysomnography (PSG) evaluation. When PSG has limited availability, automatic SA screening with a fewer number of signals should be considered. The primary purpose of this study is to develop and evaluate a SA detection model based on electrocardiogram (ECG) and blood oxygen saturation (SpO2). We adopted a multimodal approach to fuse ECG and SpO2 signals at the feature level. Then, feature selection was conducted using the recursive feature elimination with cross-validation (RFECV) algorithm and random forest (RF) classifier used to discriminate between apnea and normal events. Experiments were conducted on the Apnea-ECG database. The introduced algorithm obtained an accuracy of 97.5%, a sensitivity of 95.9%, a specificity of 98.4% and an AUC of 0.992 in per-segment classification, and outperformed previous works. The results showed that ECG and SpO2 are complementary in detecting SA, and that the combination of ECG and SpO2 enhances the ability to diagnose SA. Therefore, the proposed method has the potential to be an alternative to conventional detection methods.
- 22 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4218
Open AccessDetection of Sleep Apnea from Electrocardiogram and Pulse Oximetry Signals Using Random Forest
Sleep apnea (SA) is a common sleep disorder which could impair the human physiological system. Therefore, early diagnosis of SA is of great interest. The traditional method of diagnosing SA is an overnight polysomnography (PSG) evaluation. When PSG has limited availability, automatic SA screening with a fewer number of signals should be considered. The primary purpose of this study is to develop and evaluate a SA detection model based on electrocardiogram (ECG) and blood oxygen saturation (SpO2). We adopted a multimodal approach to fuse ECG and SpO2 signals at the feature level. Then, feature selection was conducted using the recursive feature elimination with cross-validation (RFECV) algorithm and random forest (RF) classifier used to discriminate between apnea and normal events. Experiments were conducted on the Apnea-ECG database. The introduced algorithm obtained an accuracy of 97.5%, a sensitivity of 95.9%, a specificity of 98.4% and an AUC of 0.992 in per-segment classification, and outperformed previous works. The results showed that ECG and SpO2 are complementary in detecting SA, and that the combination of ECG and SpO2 enhances the ability to diagnose SA. Therefore, the proposed method has the potential to be an alternative to conventional detection methods.
- Open Access
Noninvasive Blood Glucose Concentration Measurement Based on Conservation of Energy Metabolism and Machine Learning
Blood glucose (BG) concentration monitoring is essential for controlling complications arising from diabetes, as well as digital management of the disease. At present, finger-prick glucometers are widely used to measure BG concentrations. In consideration of the challenges of invasive BG concentration measurements involving pain, risk of infection, expense, and inconvenience, we propose a noninvasive BG concentration detection method based on the conservation of energy metabolism. In this study, a multisensor integrated detection probe was designed and manufactured by 3D-printing technology to be worn on the wrist. Two machine-learning algorithms were also applied to establish the regression model for predicting BG concentrations. The results showed that the back-propagation neural network model produced better performance than the multivariate polynomial regression model, with a mean absolute relative difference and correlation coefficient of 5.453% and 0.936, respectively. Here, about 98.413% of the predicted values were within zone A of the Clarke error grid. The above results proved the potential of our method and device for noninvasive glucose concentration detection from the human wrist.
Open AccessNoninvasive Blood Glucose Concentration Measurement Based on Conservation of Energy Metabolism and Machine Learning
Blood glucose (BG) concentration monitoring is essential for controlling complications arising from diabetes, as well as digital management of the disease. At present, finger-prick glucometers are widely used to measure BG concentrations. In consideration of the challenges of invasive BG concentration measurements involving pain, risk of infection, expense, and inconvenience, we propose a noninvasive BG concentration detection method based on the conservation of energy metabolism. In this study, a multisensor integrated detection probe was designed and manufactured by 3D-printing technology to be worn on the wrist. Two machine-learning algorithms were also applied to establish the regression model for predicting BG concentrations. The results showed that the back-propagation neural network model produced better performance than the multivariate polynomial regression model, with a mean absolute relative difference and correlation coefficient of 5.453% and 0.936, respectively. Here, about 98.413% of the predicted values were within zone A of the Clarke error grid. The above results proved the potential of our method and device for noninvasive glucose concentration detection from the human wrist.