Latest Publications
- 18 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108197
Transient tumor perfusion loss: evaluating the spatial and temporal dynamics of blood flow changes induced by ultrasound cavitation treatments
- 18 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108197
Transient tumor perfusion loss: evaluating the spatial and temporal dynamics of blood flow changes induced by ultrasound cavitation treatments
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 351-361
Delivery of Cavitation Therapy With a Modified Clinical Scanner: In Vitro Evaluation
In this study we design and implement pulses (1.67 MHz, 20-1000 cycles, 0.8—2.5 MPa, 5-100 ms pulse repetition time) suitable for microbubble cavitation treatments with a phased array of a clinical ultrasound scanner. A range of acoustic parameters was evaluated in a tissue-mimicking phantom with suspended Sonazoid microbubbles. Hydrophone measurements were used to optimize the transmit beamforming. A passive cavitation detection system was designed to measure the microbubble scattered signals over a 1 s exposure. Postprocessing of the scattered signals evaluated frequency content to extract broadband energy and calculate the inertial cavitation dose (ICD). ICD was maximized at 1000 cycles (maximum pulse length), 5 ms (fastest firing rate), and 2.5 MPa peak negative pressure (maximum pressure). Inertial cavitation was only sustained for about 3 pulses (out of 100s fired) occurring within the first 100 ms of treatment. Temporal analysis of the first 1000 cycle pulse revealed that broadband energy is sustained for the entire pulse. We also demonstrate that while inertial cavitation is possible with clinically available pulse wave Doppler settings, ICD can be significantly increased using the new conditions suggested in this work. We have delivered successful image-guided cavitation treatment after modifying a clinical scanner and monitored the cavitation dose with a PCD system on a gel phantom with suspended microbubbles. We plan to apply this technique in vivo in animal tumor models next. This work demonstrates the first implementation of long, high-pressure pulses on a clinical scanner that users can optimize for cavitation treatments.
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (3) , 351-361
Delivery of Cavitation Therapy With a Modified Clinical Scanner: In Vitro Evaluation
In this study we design and implement pulses (1.67 MHz, 20-1000 cycles, 0.8—2.5 MPa, 5-100 ms pulse repetition time) suitable for microbubble cavitation treatments with a phased array of a clinical ultrasound scanner. A range of acoustic parameters was evaluated in a tissue-mimicking phantom with suspended Sonazoid microbubbles. Hydrophone measurements were used to optimize the transmit beamforming. A passive cavitation detection system was designed to measure the microbubble scattered signals over a 1 s exposure. Postprocessing of the scattered signals evaluated frequency content to extract broadband energy and calculate the inertial cavitation dose (ICD). ICD was maximized at 1000 cycles (maximum pulse length), 5 ms (fastest firing rate), and 2.5 MPa peak negative pressure (maximum pressure). Inertial cavitation was only sustained for about 3 pulses (out of 100s fired) occurring within the first 100 ms of treatment. Temporal analysis of the first 1000 cycle pulse revealed that broadband energy is sustained for the entire pulse. We also demonstrate that while inertial cavitation is possible with clinically available pulse wave Doppler settings, ICD can be significantly increased using the new conditions suggested in this work. We have delivered successful image-guided cavitation treatment after modifying a clinical scanner and monitored the cavitation dose with a PCD system on a gel phantom with suspended microbubbles. We plan to apply this technique in vivo in animal tumor models next. This work demonstrates the first implementation of long, high-pressure pulses on a clinical scanner that users can optimize for cavitation treatments.
- 24 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (3) , 1032-1040
Investigation of the Phase of Nonlinear Echoes From Microbubbles During Amplitude Modulation
Contrast-enhanced ultrasound imaging relies on distinguishing between microbubble and tissue echoes. Amplitude modulation, a nonlinear pulsing scheme, has been developed to take advantage of amplitude-dependent nonlinearity of microbubble echoes. However, with amplitude modulation, tissue nonlinear propagation can also degrade image contrast. Segmentation of contrast-enhanced ultrasound images based on amplitude-dependent phase difference in the echoes, defined in the present manuscript as ΔΦAM, has been proposed as an additional method of enhancing contrast-to-tissue ratio as tissue is not expected to create the same degree of ΔΦAM; however, this has not been robustly investigated. In this work, we evaluate the source of ΔΦAM through simulations of unshelled versus shelled microbubble oscillation and simulations of nonlinear propagation in tissue. We then validate the simulated ΔΦAM results with experimental ΔΦAM measurements during in vitro scattering and imaging in a flow phantom. We show that shelled and unshelled microbubbles resulted in a ΔΦAM with similar overall magnitude with some differences in trends, and that tissue echoes have a small yet detectable degree of ΔΦAM due to nonlinear propagation. The results from this work can help inform optimal parameter selection for phase segmentation and implementation on clinical scanner.
- 24 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (3) , 1032-1040
Investigation of the Phase of Nonlinear Echoes From Microbubbles During Amplitude Modulation
Contrast-enhanced ultrasound imaging relies on distinguishing between microbubble and tissue echoes. Amplitude modulation, a nonlinear pulsing scheme, has been developed to take advantage of amplitude-dependent nonlinearity of microbubble echoes. However, with amplitude modulation, tissue nonlinear propagation can also degrade image contrast. Segmentation of contrast-enhanced ultrasound images based on amplitude-dependent phase difference in the echoes, defined in the present manuscript as ΔΦAM, has been proposed as an additional method of enhancing contrast-to-tissue ratio as tissue is not expected to create the same degree of ΔΦAM; however, this has not been robustly investigated. In this work, we evaluate the source of ΔΦAM through simulations of unshelled versus shelled microbubble oscillation and simulations of nonlinear propagation in tissue. We then validate the simulated ΔΦAM results with experimental ΔΦAM measurements during in vitro scattering and imaging in a flow phantom. We show that shelled and unshelled microbubbles resulted in a ΔΦAM with similar overall magnitude with some differences in trends, and that tissue echoes have a small yet detectable degree of ΔΦAM due to nonlinear propagation. The results from this work can help inform optimal parameter selection for phase segmentation and implementation on clinical scanner.