Latest Publications

  • Open Access

    An Unbalance Three Phase Currents Detection Technique for Load Side Broken Conductor Fault in the Iraqi Distribution System

    by Ali G. Al-Baghdadi, Mohammed K. Abd, Firas M. F. Flaih

    Electrical supply safety and quality represent targets that Iraqi power distribution companies always strive to meet. Load-side broken conductor fault LSBC is one of the greatest faults affecting both targets. Stand out since the magnitudes of the impact on the system are too small to activate the relevant system protection devices in Iraqi substation 33/11kV. Therefore, protection from LSBC faults has been one of the biggest challenges in the Iraqi electrical distribution system. In this context, the main aim of this article is to present a method for detecting LSBC faults by unbalanced three-phase currents faults measured in a 33/11kv distribution substation. Using computer simulations based on an actual distribution 11kV feeder model, this method was qualitatively tested. Then, a relationship between mathematical and simulation results was made. Finally, A comparison of the proposed method and recent literature was written. According to the obtained results of case studies, the protection devices in the Iraqi substations cannot efficiently sense the LSBC fault. The overcurrent relay is completely not sensitive to LSBC, and the neutral current fault relay is only sensitive (0-70)% of the different types of feeders under the study. While the proposed unbalance, the current method had been detected with 87% -93% of 11 kV feeders. The proposed techniques are applicable and compatible with the existing traditional protection of the overcurrent and earth fault protection system in the Iraqi 33/11kV substation.


  • Open Access

    A New Detection Method for Load Side Broken Conductor Fault Based on Negative to Positive Current Sequence

    by Ali G. Al-Baghdadi, Mohammed Kdair Abd, Firas M. F. Flaih

    Faults in distribution overhead lines occur due to various reasons, such as rain, strong winds, lightning, and other natural causes. The protection from the load side broken conductor (LSBC) faults has been one of the biggest challenges in the power distribution network. The small current generated by the LSBC fault makes the traditional protection system unable to detect this type of fault. The danger of LSBC fault is still enormous; besides, the available works of literature addressing this issue face difficulties when applying it to the real power system. This paper proposes a new method for detecting LSBC fault using single-ended measurements to the overhead distribution lines. The detection method is based on the constant ratio of negative to positive sequence current measured at the feeder end. The proposed study is performed using MATLAB software to implement a real network as a case study and verified by mathematical analysis. According to obtained results, we demonstrated that the fault in the electrical network had been detected with 100% of feeder protection. The proposed method has the benefit of being applicable and compatible with the existing measurement equipment, even when used in conjunction with overcurrent and earth fault relay in the electrical substation. Therefore, the negative to positive sequence currents are powerful in aiding fault detection. The benefit of this approach is providing a suitable LSBC protection solution for utilities while also opening new prospects in fault detection techniques in the distribution system.