Sabiq Muhtadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sabiq Muhtadi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Caterina M. Gallippi
Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA
4 shared publications Ahmad Chowdhury
Department of Electrical and Electronic Engineering, Islamic University of Technology, Gazipur, Bangladesh
1 shared publication- Ahmad Chowdhury
Islamic University of Technology, Department of Electrical and Electronic Engineering, Gazipur, Bangladesh
1 shared publication Ahmad Shafiullah
Department of Electrical and Electronic Engineering, Islamic University of Technology, Gazipur, Bangladesh
1 shared publication- Asif Newaz
Dept. of Electrical and Electronic Engineering Islamic University of Technology Gazipur Bangladesh
1 shared publication Brian S. Garra
Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, United States
1 shared publication
Latest Publications
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (5) , 511-523
Deep-DoPIo: Deep Learning for Shear Elasticity Prediction in Double-Profile Intersection Ultrasound
We herein propose Deep-DoPIo, a deep learning–based framework that predicts shear elastic modulus from paired narrow- and wide-track displacement profiles generated by a single acoustic radiation force (ARF) push. Unlike the traditional Double Profile Intersection (DoPIo) ultrasound technique, which relates the intersection time (tint) between these profiles to shear modulus through a linear empirical model, Deep-DoPIo leverages neural networks to learn this mapping directly from the displacement data. Four architectures were evaluated: a feed-forward neural network (FFNN), a one-dimensional convolutional neural network (CNN), an encoder–transformer (E-Tr), and a one-dimensional vision transformer (ViT). Models were trained on simulated displacement data and fine-tuned on calibrated phantom measurements for domain adaptation. Across simulated materials, traditional DoPIo yielded increasing mean absolute errors (MAE) with increasing material stiffness, with MAE exceeding 13 kPa for 28 kPa material. Conversely, all examined DNN models maintained MAEs below 0.5 kPa regardless of material stiffness. In calibrated phantoms, FFNN and CNN produced similar error trends to traditional DoPIo (MAE ≈ 4-8 kPa in a 22.20 kPa medium), indicating limited benefit over the empirical approach. By contrast, transformer-based models (E-Tr and ViT) consistently yielded low errors (<0.2 kPa) across all media of varying stiffness. In a custom liver phantom with a gelatin–graphite inclusion, traditional DoPIo substantially underestimated elasticity relative to shear wave elasticity imaging (SWEI), with errors approaching 50%. In contrast, transformer-based elasticity predictions closely matched those of SWEI, differing by less than 4% in the inclusion and less than 9% in the background. These results demonstrate that transformer-based architectures can generalize from simulation to both calibrated and excised tissue phantoms, providing accurate shear modulus estimates under conditions where traditional DoPIo struggles. Future work will evaluate performance in vivo and systematically compare Deep-DoPIo against SWEI under clinically relevant conditions.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (5) , 511-523
Deep-DoPIo: Deep Learning for Shear Elasticity Prediction in Double-Profile Intersection Ultrasound
We herein propose Deep-DoPIo, a deep learning–based framework that predicts shear elastic modulus from paired narrow- and wide-track displacement profiles generated by a single acoustic radiation force (ARF) push. Unlike the traditional Double Profile Intersection (DoPIo) ultrasound technique, which relates the intersection time (tint) between these profiles to shear modulus through a linear empirical model, Deep-DoPIo leverages neural networks to learn this mapping directly from the displacement data. Four architectures were evaluated: a feed-forward neural network (FFNN), a one-dimensional convolutional neural network (CNN), an encoder–transformer (E-Tr), and a one-dimensional vision transformer (ViT). Models were trained on simulated displacement data and fine-tuned on calibrated phantom measurements for domain adaptation. Across simulated materials, traditional DoPIo yielded increasing mean absolute errors (MAE) with increasing material stiffness, with MAE exceeding 13 kPa for 28 kPa material. Conversely, all examined DNN models maintained MAEs below 0.5 kPa regardless of material stiffness. In calibrated phantoms, FFNN and CNN produced similar error trends to traditional DoPIo (MAE ≈ 4-8 kPa in a 22.20 kPa medium), indicating limited benefit over the empirical approach. By contrast, transformer-based models (E-Tr and ViT) consistently yielded low errors (<0.2 kPa) across all media of varying stiffness. In a custom liver phantom with a gelatin–graphite inclusion, traditional DoPIo substantially underestimated elasticity relative to shear wave elasticity imaging (SWEI), with errors approaching 50%. In contrast, transformer-based elasticity predictions closely matched those of SWEI, differing by less than 4% in the inclusion and less than 9% in the background. These results demonstrate that transformer-based architectures can generalize from simulation to both calibrated and excised tissue phantoms, providing accurate shear modulus estimates under conditions where traditional DoPIo struggles. Future work will evaluate performance in vivo and systematically compare Deep-DoPIo against SWEI under clinically relevant conditions.
- Open Access
- 23 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 161-165
Double Profile Intersection (DoPIo) Ultrasound With Acoustic Radiation Force Tilting Interrogates Young’s Modulus in Transversely Isotropic Media: An In Silico Study
This study evaluates the potential for interrogating the Young’s elastic moduli in anisotropic media, including tissue, using Double Profile Intersection (DoPIo) ultrasound. DoPIo is an on-axis acoustic radiation force (ARF)-based elasticity imaging method that quantifies shear elasticity without relying on shear wave propagation. It is hypothesized that by applying a range of ARF excitations that are not perpendicular to the axis of symmetry (AoS) of transversely isotropic (TI) materials and monitoring the resultant variation in DoPIo-measured elasticity versus excitation angle, the Young’s elastic modulus may be interrogated in addition to the shear elastic modulus. The hypothesis was tested in silico, and results suggested that while DoPIo outcomes measured at normal (90°) ARF-AoS incidence were related to the shear elastic modulus alone, variation in DoPIo-derived elasticity over ARF-AoS incidence angle (defined as $\Delta \textit {Elasticity}$ ) exhibited a strong linear correlation with the longitudinal Young’s modulus ( ${E}_{L}$ ). The results suggest that ${E}_{L}$ evaluated by the rate of change of $\Delta \textit {Elasticity}$ with ARF-AoS incidence angle may serve as a novel biomarker for characterizing elastically anisotropic tissues such as kidney, skeletal muscle, and breast.
- 23 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 161-165
Open AccessDouble Profile Intersection (DoPIo) Ultrasound With Acoustic Radiation Force Tilting Interrogates Young’s Modulus in Transversely Isotropic Media: An In Silico Study
This study evaluates the potential for interrogating the Young’s elastic moduli in anisotropic media, including tissue, using Double Profile Intersection (DoPIo) ultrasound. DoPIo is an on-axis acoustic radiation force (ARF)-based elasticity imaging method that quantifies shear elasticity without relying on shear wave propagation. It is hypothesized that by applying a range of ARF excitations that are not perpendicular to the axis of symmetry (AoS) of transversely isotropic (TI) materials and monitoring the resultant variation in DoPIo-measured elasticity versus excitation angle, the Young’s elastic modulus may be interrogated in addition to the shear elastic modulus. The hypothesis was tested in silico, and results suggested that while DoPIo outcomes measured at normal (90°) ARF-AoS incidence were related to the shear elastic modulus alone, variation in DoPIo-derived elasticity over ARF-AoS incidence angle (defined as $\Delta \textit {Elasticity}$ ) exhibited a strong linear correlation with the longitudinal Young’s modulus ( ${E}_{L}$ ). The results suggest that ${E}_{L}$ evaluated by the rate of change of $\Delta \textit {Elasticity}$ with ARF-AoS incidence angle may serve as a novel biomarker for characterizing elastically anisotropic tissues such as kidney, skeletal muscle, and breast.
- 14 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-18
Breast tumor diagnosis via multimodal deep learning using ultrasound B-mode and Nakagami images
PurposeWe propose and evaluate multimodal deep learning (DL) approaches that combine ultrasound (US) B-mode and Nakagami parametric images for breast tumor classification. It is hypothesized that integrating tissue brightness information from B-mode images with scattering properties from Nakagami images will enhance diagnostic performance compared with single-input approaches.ApproachAn EfficientNetV2B0 network was used to develop multimodal DL frameworks that took as input (i) numerical two-dimensional (2D) maps or (ii) rendered red-green-blue (RGB) representations of both B-mode and Nakagami data. The diagnostic performance of these frameworks was compared with single-input counterparts using 831 US acquisitions from 264 patients. In addition, gradient-weighted class activation mapping was applied to evaluate diagnostically relevant information utilized by the different networks.ResultsThe multimodal architectures demonstrated significantly higher area under the receiver operating characteristic curve (AUC) values (p<0.05) than their monomodal counterparts, achieving an average improvement of 10.75%. In addition, the multimodal networks incorporated, on average, 15.70% more diagnostically relevant tissue information. Among the multimodal models, those using RGB representations as input outperformed those that utilized 2D numerical data maps (p<0.05). The top-performing multimodal architecture achieved a mean AUC of 0.896 [95% confidence interval (CI): 0.813 to 0.959] when performance was assessed at the image level and 0.848 (95% CI: 0.755 to 0.903) when assessed at the lesion level.ConclusionsIncorporating B-mode and Nakagami information together in a multimodal DL framework improved classification outcomes and increased the amount of diagnostically relevant information accessed by networks, highlighting the potential for automating and standardizing US breast cancer diagnostics to enhance clinical outcomes.
- 14 May 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S2) , 1-18
Breast tumor diagnosis via multimodal deep learning using ultrasound B-mode and Nakagami images
PurposeWe propose and evaluate multimodal deep learning (DL) approaches that combine ultrasound (US) B-mode and Nakagami parametric images for breast tumor classification. It is hypothesized that integrating tissue brightness information from B-mode images with scattering properties from Nakagami images will enhance diagnostic performance compared with single-input approaches.ApproachAn EfficientNetV2B0 network was used to develop multimodal DL frameworks that took as input (i) numerical two-dimensional (2D) maps or (ii) rendered red-green-blue (RGB) representations of both B-mode and Nakagami data. The diagnostic performance of these frameworks was compared with single-input counterparts using 831 US acquisitions from 264 patients. In addition, gradient-weighted class activation mapping was applied to evaluate diagnostically relevant information utilized by the different networks.ResultsThe multimodal architectures demonstrated significantly higher area under the receiver operating characteristic curve (AUC) values (p<0.05) than their monomodal counterparts, achieving an average improvement of 10.75%. In addition, the multimodal networks incorporated, on average, 15.70% more diagnostically relevant tissue information. Among the multimodal models, those using RGB representations as input outperformed those that utilized 2D numerical data maps (p<0.05). The top-performing multimodal architecture achieved a mean AUC of 0.896 [95% confidence interval (CI): 0.813 to 0.959] when performance was assessed at the image level and 0.848 (95% CI: 0.755 to 0.903) when assessed at the lesion level.ConclusionsIncorporating B-mode and Nakagami information together in a multimodal DL framework improved classification outcomes and increased the amount of diagnostically relevant information accessed by networks, highlighting the potential for automating and standardizing US breast cancer diagnostics to enhance clinical outcomes.
- Open Access
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 204-215
VisR Ultrasound With Non-Normal ARF-AoS Incidence Interrogates Both Shear and Young’s Elastic Moduli in Transversely Isotropic Materials
This study evaluates the potential for interrogating the Young's elastic moduli in anisotropic media, including tissue, using Viscoelastic Response (VisR) ultrasound. VisR is an on-axis acoustic radiation force (ARF)-based elasticity imaging method that has been demonstrated previously for assessing the shear elastic moduli of transversely isotropic (TI) materials when the applied ARF excitation was incident normal to the axis of symmetry (AoS). It is hypothesized that by applying a range of non-normal ARF excitations and monitoring the percent change in VisR-derived relative elasticity (RE) versus ARF-AoS incidence angle, both the shear and the Young's elastic moduli may be interrogated. The hypothesis was tested using in silico experiments, which showed that while RE measured at normal ARF-AoS incidence was related to only longitudinal shear modulus (μ L ) alone, the percent change in RE over ARF-AoS incidence angle (defined as Δ RE ) exhibited a strong linear correlation with the ratio of longitudinal shear-to-Young’s moduli (μ L / EL ), with correlation coefficients of 0.97-0.99. Additionally, the linear regression slopes of Δ RE versus ARF-AoS incidence angle statistically discriminated TI materials with μ L / EL ratios that were as little as 7% different. These findings were validated ex vivo in chicken pectoralis major and bovine longissimus dorsi muscles, where the rate of change in of Δ RE versus ARF-AoS incidence angle distinguished the two muscles with statistical significance. The results obtained in this study suggest that the rate of change of Δ RE with ARF-AoS incidence angle may serve as a novel, semi-quantitative biomarker for characterizing anisotropic tissues such as kidney, skeletal muscle, and breast.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 4, 204-215
Open AccessVisR Ultrasound With Non-Normal ARF-AoS Incidence Interrogates Both Shear and Young’s Elastic Moduli in Transversely Isotropic Materials
This study evaluates the potential for interrogating the Young's elastic moduli in anisotropic media, including tissue, using Viscoelastic Response (VisR) ultrasound. VisR is an on-axis acoustic radiation force (ARF)-based elasticity imaging method that has been demonstrated previously for assessing the shear elastic moduli of transversely isotropic (TI) materials when the applied ARF excitation was incident normal to the axis of symmetry (AoS). It is hypothesized that by applying a range of non-normal ARF excitations and monitoring the percent change in VisR-derived relative elasticity (RE) versus ARF-AoS incidence angle, both the shear and the Young's elastic moduli may be interrogated. The hypothesis was tested using in silico experiments, which showed that while RE measured at normal ARF-AoS incidence was related to only longitudinal shear modulus (μ L ) alone, the percent change in RE over ARF-AoS incidence angle (defined as Δ RE ) exhibited a strong linear correlation with the ratio of longitudinal shear-to-Young’s moduli (μ L / EL ), with correlation coefficients of 0.97-0.99. Additionally, the linear regression slopes of Δ RE versus ARF-AoS incidence angle statistically discriminated TI materials with μ L / EL ratios that were as little as 7% different. These findings were validated ex vivo in chicken pectoralis major and bovine longissimus dorsi muscles, where the rate of change in of Δ RE versus ARF-AoS incidence angle distinguished the two muscles with statistical significance. The results obtained in this study suggest that the rate of change of Δ RE with ARF-AoS incidence angle may serve as a novel, semi-quantitative biomarker for characterizing anisotropic tissues such as kidney, skeletal muscle, and breast.
- 1 February 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (S2) , S22410-18
Texture quantified from ultrasound Nakagami parametric images is diagnostically relevant for breast tumor characterization
According to the World Health Organization (WHO), breast cancer is the most prevalent form of cancer for women around the world, with a staggering 7.8 million patients being diagnosed in the 5-year period between 2016 and 2020.1 Approximately 2.3 million new cases of breast cancer were reported worldwide in 2020, along with almost 700,000 deaths, which accounts for 6.9% of all cancer-related deaths.2 The key to improving survival of breast cancer patients is early diagnosis before the cancer can invade surrounding tissue.
- 1 February 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (S2) , S22410-18
Texture quantified from ultrasound Nakagami parametric images is diagnostically relevant for breast tumor characterization
According to the World Health Organization (WHO), breast cancer is the most prevalent form of cancer for women around the world, with a staggering 7.8 million patients being diagnosed in the 5-year period between 2016 and 2020.1 Approximately 2.3 million new cases of breast cancer were reported worldwide in 2020, along with almost 700,000 deaths, which accounts for 6.9% of all cancer-related deaths.2 The key to improving survival of breast cancer patients is early diagnosis before the cancer can invade surrounding tissue.
- 4 April 2022
- Published by Elsevier in Ultrasonics
- Vol. 124, 106744
Ultrasound classification of breast masses using a comprehensive Nakagami imaging and machine learning framework
- 4 April 2022
- Published by Elsevier in Ultrasonics
- Vol. 124, 106744
Ultrasound classification of breast masses using a comprehensive Nakagami imaging and machine learning framework
- 25 March 2022
- Published by Elsevier in Knowledge-Based Systems
- Vol. 245
An intelligent decision support system for the accurate diagnosis of cervical cancer
- 25 March 2022
- Published by Elsevier in Knowledge-Based Systems
- Vol. 245
An intelligent decision support system for the accurate diagnosis of cervical cancer
- Open Access
- 7 March 2022
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2022, 1-18
Breast Tumor Classification Using Intratumoral Quantitative Ultrasound Descriptors
Breast cancer is a global epidemic, responsible for one of the highest mortality rates among women. Ultrasound imaging is becoming a popular tool for breast cancer screening, and quantitative ultrasound (QUS) techniques are being increasingly applied by researchers in an attempt to characterize breast tissue. Several different quantitative descriptors for breast cancer have been explored by researchers. This study proposes a breast tumor classification system using the three major types of intratumoral QUS descriptors which can be extracted from ultrasound radiofrequency (RF) data: spectral features, envelope statistics features, and texture features. A total of 16 features were extracted from ultrasound RF data across two different datasets, of which one is balanced and the other is severely imbalanced. The balanced dataset contains RF data of 100 patients with breast tumors, of which 48 are benign and 52 are malignant. The imbalanced dataset contains RF data of 130 patients with breast tumors, of which 104 are benign and 26 are malignant. Holdout validation was used to split the balanced dataset into 60% training and 40% testing sets. Feature selection was applied on the training set to identify the most relevant subset for the classification of benign and malignant breast tumors, and the performance of the features was evaluated on the test set. A maximum classification accuracy of 95% and an area under the receiver operating characteristic curve (AUC) of 0.968 was obtained on the test set. The performance of the identified relevant features was further validated on the imbalanced dataset, where a hybrid resampling strategy was firstly utilized to create an optimal balance between benign and malignant samples. A maximum classification accuracy of 93.01%, sensitivity of 94.62%, specificity of 91.4%, and AUC of 0.966 were obtained. The results indicate that the identified features are able to distinguish between benign and malignant breast lesions very effectively, and the combination of the features identified in this research has the potential to be a significant tool in the noninvasive rapid and accurate diagnosis of breast cancer.
- 7 March 2022
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2022, 1-18
Open AccessBreast Tumor Classification Using Intratumoral Quantitative Ultrasound Descriptors
Breast cancer is a global epidemic, responsible for one of the highest mortality rates among women. Ultrasound imaging is becoming a popular tool for breast cancer screening, and quantitative ultrasound (QUS) techniques are being increasingly applied by researchers in an attempt to characterize breast tissue. Several different quantitative descriptors for breast cancer have been explored by researchers. This study proposes a breast tumor classification system using the three major types of intratumoral QUS descriptors which can be extracted from ultrasound radiofrequency (RF) data: spectral features, envelope statistics features, and texture features. A total of 16 features were extracted from ultrasound RF data across two different datasets, of which one is balanced and the other is severely imbalanced. The balanced dataset contains RF data of 100 patients with breast tumors, of which 48 are benign and 52 are malignant. The imbalanced dataset contains RF data of 130 patients with breast tumors, of which 104 are benign and 26 are malignant. Holdout validation was used to split the balanced dataset into 60% training and 40% testing sets. Feature selection was applied on the training set to identify the most relevant subset for the classification of benign and malignant breast tumors, and the performance of the features was evaluated on the test set. A maximum classification accuracy of 95% and an area under the receiver operating characteristic curve (AUC) of 0.968 was obtained on the test set. The performance of the identified relevant features was further validated on the imbalanced dataset, where a hybrid resampling strategy was firstly utilized to create an optimal balance between benign and malignant samples. A maximum classification accuracy of 93.01%, sensitivity of 94.62%, specificity of 91.4%, and AUC of 0.966 were obtained. The results indicate that the identified features are able to distinguish between benign and malignant breast lesions very effectively, and the combination of the features identified in this research has the potential to be a significant tool in the noninvasive rapid and accurate diagnosis of breast cancer.