Umberto Camellin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Umberto Camellin has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Pasquale Aragona
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98125 Messina, Italy
7 shared publications - Alessandro Meduri
Department of Biomedical and Dental Science and of Morphological and Functional Images, University of Messina, 98122 Messina, Italy
4 shared publications - Anna Maria Roszkowska
Department of Biomedical Sciences, University of Messina, 98122 Messina, Italy
4 shared publications - Antonio Valastro
Ophthalmology Department, Beauregard Hospital, Azienda USL della Valle d'Aosta, Aosta, Italy
2 shared publications - Domenico Schiano-Lomoriello
IRCCS Fondazione G.B. Bietti, Rome, Italy
2 shared publications - Francesco Franchina
Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, 98125 Messina, Italy
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3194
Multivariate Analysis of the Spatial Distance Between the Corneal Thinnest Point and Maximum Keratometry in Keratoconic Corneas: Association with Disease Severity
Background: This study quantified the planar distance (D, mm) between the corneal thinnest point (TP) and maximum keratometry (Kmax) and examined its association with tomographic features and keratoconus severity. Methods: Tomographic data from 140 patients (280 eyes) with bilateral manifest keratoconus were obtained with a Scheimpflug camera (Pentacam HR; Oculus, Wetzlar, Germany). D was calculated from the Cartesian coordinates of TP and Kmax. A multiple linear regression model included simulated anterior average keratometry (SimKavg), anterior and posterior radii of curvature (ARC and PRC), and anterior Q-value (Q-ant). Inference used patient-clustered robust standard errors. Internal validation comprised repeated grouped 10-fold cross-validation and patient-level bootstrap resampling. Performance was assessed using R2, root-mean-square error (RMSE), mean absolute error (MAE), and Bland–Altman limits of agreement. Results: The model explained 51.8% of the apparent variance in D (adjusted R2 = 0.511; p < 0.001). Apparent RMSE and MAE were 0.568 and 0.428 mm. Mean grouped cross-validated performance was R2 = 0.472, RMSE = 0.594 mm, and MAE = 0.443 mm. The out-of-fold bias was −0.005 mm, with 95% limits of agreement from −1.162 to +1.151 mm. ARC, SimKavg, and Q-ant remained significant with patient-clustered inference, whereas PRC did not (p = 0.111). Conclusions: D was associated with keratoconus severity and could be estimated with moderate internal performance from routinely available tomographic variables. Collinearity, fellow-eye dependence, and limits of agreement of approximately ±1.1 mm restrict interpretation of individual coefficients and preclude interchangeability with direct measurement. External and longitudinal validation is required before clinical use.
- 1 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (19) , 3194
Open AccessMultivariate Analysis of the Spatial Distance Between the Corneal Thinnest Point and Maximum Keratometry in Keratoconic Corneas: Association with Disease Severity
Background: This study quantified the planar distance (D, mm) between the corneal thinnest point (TP) and maximum keratometry (Kmax) and examined its association with tomographic features and keratoconus severity. Methods: Tomographic data from 140 patients (280 eyes) with bilateral manifest keratoconus were obtained with a Scheimpflug camera (Pentacam HR; Oculus, Wetzlar, Germany). D was calculated from the Cartesian coordinates of TP and Kmax. A multiple linear regression model included simulated anterior average keratometry (SimKavg), anterior and posterior radii of curvature (ARC and PRC), and anterior Q-value (Q-ant). Inference used patient-clustered robust standard errors. Internal validation comprised repeated grouped 10-fold cross-validation and patient-level bootstrap resampling. Performance was assessed using R2, root-mean-square error (RMSE), mean absolute error (MAE), and Bland–Altman limits of agreement. Results: The model explained 51.8% of the apparent variance in D (adjusted R2 = 0.511; p < 0.001). Apparent RMSE and MAE were 0.568 and 0.428 mm. Mean grouped cross-validated performance was R2 = 0.472, RMSE = 0.594 mm, and MAE = 0.443 mm. The out-of-fold bias was −0.005 mm, with 95% limits of agreement from −1.162 to +1.151 mm. ARC, SimKavg, and Q-ant remained significant with patient-clustered inference, whereas PRC did not (p = 0.111). Conclusions: D was associated with keratoconus severity and could be estimated with moderate internal performance from routinely available tomographic variables. Collinearity, fellow-eye dependence, and limits of agreement of approximately ±1.1 mm restrict interpretation of individual coefficients and preclude interchangeability with direct measurement. External and longitudinal validation is required before clinical use.
- Open Access
- 14 August 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (Suppl 5) , S831-S837
Estimation of pupil size at iris plane and its magnification after cataract surgery
Purpose: To estimate the pupil size (at the iris plane) under photopic (P PH ) and scotopic (P S ) conditions after phacoemulsification with intraocular lens (IOL) implantation. Methods: This retrospective observational cohort study included: 190 virgin eyes from 190 patients who underwent cataract surgery with IOL implantation. Data collected with Aladdin (Topcon), AS-OCT MS-39 (CSO), and iTrace (Tracey) were SimK, mean pupillary power at 6 mm (MPP), anterior chamber depth (ACD), lens thickness (LT), axial length (AL), lens rise (LR), P PH and P S before and after surgery at 30 days, dysfunctional lens index, and opacity grade. The position of the postoperative iris plane (PIP) was measured manually with MS-39, and a multivariate regression formula was developed to predict it. Statistical analysis was performed using Statistical Package for Social Science (SPSS) (IBM). Results: The mean and standard deviations were 42.61 ± 3.20 D for MMP at 6 mm, 3.35 ± 0.37 mm for ACD, 3.89 ± 0.18 mm for PIP ( P < 0.01), 4.55 ± 0.42 mm for LT, 0.43 ± 0.24 mm for LR, and 25.91 ± 3.03 mm for AL. The mean preoperative and postoperative topographic pupil magnification was 12% and 14.22%, respectively ( P < 0.01). Despite an increase in magnification, the postoperative pupil was smaller than the preoperative one both for scotopic and photopic conditions: The larger the preoperative pupil, the more it tends to reduce in the postoperative period. Conclusions: Analysis of the preoperative topographic pupil alone is not sufficient for a correct indication of the optical zone and total diameter of IOL to be implanted but must be correlated with biometric data. The topographic pupil, therefore, undergoes a change in magnification from the preoperative period to the postoperative period. Furthermore, the real pupil presents a modification and, in most cases, tends to be smaller postoperatively in both photopic and scotopic conditions.
- 14 August 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (Suppl 5) , S831-S837
Open AccessEstimation of pupil size at iris plane and its magnification after cataract surgery
Purpose: To estimate the pupil size (at the iris plane) under photopic (P PH ) and scotopic (P S ) conditions after phacoemulsification with intraocular lens (IOL) implantation. Methods: This retrospective observational cohort study included: 190 virgin eyes from 190 patients who underwent cataract surgery with IOL implantation. Data collected with Aladdin (Topcon), AS-OCT MS-39 (CSO), and iTrace (Tracey) were SimK, mean pupillary power at 6 mm (MPP), anterior chamber depth (ACD), lens thickness (LT), axial length (AL), lens rise (LR), P PH and P S before and after surgery at 30 days, dysfunctional lens index, and opacity grade. The position of the postoperative iris plane (PIP) was measured manually with MS-39, and a multivariate regression formula was developed to predict it. Statistical analysis was performed using Statistical Package for Social Science (SPSS) (IBM). Results: The mean and standard deviations were 42.61 ± 3.20 D for MMP at 6 mm, 3.35 ± 0.37 mm for ACD, 3.89 ± 0.18 mm for PIP ( P < 0.01), 4.55 ± 0.42 mm for LT, 0.43 ± 0.24 mm for LR, and 25.91 ± 3.03 mm for AL. The mean preoperative and postoperative topographic pupil magnification was 12% and 14.22%, respectively ( P < 0.01). Despite an increase in magnification, the postoperative pupil was smaller than the preoperative one both for scotopic and photopic conditions: The larger the preoperative pupil, the more it tends to reduce in the postoperative period. Conclusions: Analysis of the preoperative topographic pupil alone is not sufficient for a correct indication of the optical zone and total diameter of IOL to be implanted but must be correlated with biometric data. The topographic pupil, therefore, undergoes a change in magnification from the preoperative period to the postoperative period. Furthermore, the real pupil presents a modification and, in most cases, tends to be smaller postoperatively in both photopic and scotopic conditions.
- 3 November 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (4) , 1046-1052
Comparison between IOL MASTER 500 and MYAH with vector analysis in low and mild anterior corneal astigmatism
Purpose: Evaluate the agreement between IOL Master 500 (Carl Zeiss Meditec AG, Germany) and MYAH (Topcon EU, Visia Imaging, Japan) in measuring axial length, keratometry, and anterior corneal astigmatism. Setting: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Ophthalmology Clinic, University of Messina, Messina, Italy. Methods: In this prospective study, 40 eyes (right eye 25, left eye 15) of 40 patients were included. Axial length (AL), keratometry (K1, K2), and anterior corneal astigmatism (ACA) were measured. AL, mean K (Kavg) and magnitude of ACA were compared using Bland – Altman plot analysis, parametric and nonparametric statistical analysis. The difference vector and angle of error of the ACA measured by the two devices were evaluated by vector analysis using polar diagrams. Results: Mean and standard deviation with IOL Master and with MYAH device was for AL 24.25 ± 1.22 mm and 24.25 ± 1.22 mm (p = .99), for Kavg 42.75 ± 1.53 D and 42.85 ± 1.52 D (p = .78), for Magnitude of ACA 1.00 ± 0.58 D and 0.89 ± 0.56 D (p = .38) respectively. High correlations were found for AL (R² = 0.999), Kavg (R² = 0.996), and ACA Magnitude (R² = 0.889). Bland-Altman analysis of the two devices found high agreement and absence of proportional bias (MYAH-IOL MASTER) were found between the two assessments for AL (bias = −0.0005 mm, p = .93), Kavg (bias = 0.0955 D, p = .76) and ACA (bias = 0.11 D, p = .41). Limit of agreement (upper/lower LoA, 95%CI) were respectively +0.057/−0.058 mm for AL, + 0.29/−0.09 D for Kavg and +0.49/−0.27 D for ACA. No statistical difference was found between the x-component and y-component of the ACA vector (p > .01), the difference vector (IOL MASTER-MYAH) was +0.14 D axis 159 with an absolute mean angle of error of 7.2 ± 7.5 degree. Conclusions: The instruments appear to be interchangeable for measurements of AL, keratometry, and magnitude of ACA with high agreement between the two devices. Also, in the presence of low astigmatism, the two instruments give the same results in terms of ACA.
- 3 November 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 34 (4) , 1046-1052
Comparison between IOL MASTER 500 and MYAH with vector analysis in low and mild anterior corneal astigmatism
Purpose: Evaluate the agreement between IOL Master 500 (Carl Zeiss Meditec AG, Germany) and MYAH (Topcon EU, Visia Imaging, Japan) in measuring axial length, keratometry, and anterior corneal astigmatism. Setting: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Ophthalmology Clinic, University of Messina, Messina, Italy. Methods: In this prospective study, 40 eyes (right eye 25, left eye 15) of 40 patients were included. Axial length (AL), keratometry (K1, K2), and anterior corneal astigmatism (ACA) were measured. AL, mean K (Kavg) and magnitude of ACA were compared using Bland – Altman plot analysis, parametric and nonparametric statistical analysis. The difference vector and angle of error of the ACA measured by the two devices were evaluated by vector analysis using polar diagrams. Results: Mean and standard deviation with IOL Master and with MYAH device was for AL 24.25 ± 1.22 mm and 24.25 ± 1.22 mm (p = .99), for Kavg 42.75 ± 1.53 D and 42.85 ± 1.52 D (p = .78), for Magnitude of ACA 1.00 ± 0.58 D and 0.89 ± 0.56 D (p = .38) respectively. High correlations were found for AL (R² = 0.999), Kavg (R² = 0.996), and ACA Magnitude (R² = 0.889). Bland-Altman analysis of the two devices found high agreement and absence of proportional bias (MYAH-IOL MASTER) were found between the two assessments for AL (bias = −0.0005 mm, p = .93), Kavg (bias = 0.0955 D, p = .76) and ACA (bias = 0.11 D, p = .41). Limit of agreement (upper/lower LoA, 95%CI) were respectively +0.057/−0.058 mm for AL, + 0.29/−0.09 D for Kavg and +0.49/−0.27 D for ACA. No statistical difference was found between the x-component and y-component of the ACA vector (p > .01), the difference vector (IOL MASTER-MYAH) was +0.14 D axis 159 with an absolute mean angle of error of 7.2 ± 7.5 degree. Conclusions: The instruments appear to be interchangeable for measurements of AL, keratometry, and magnitude of ACA with high agreement between the two devices. Also, in the presence of low astigmatism, the two instruments give the same results in terms of ACA.
- Open Access
IOL Power Calculation in an Unusual Long Fellow Eye: A Case Report
Background: Intra-Ocular Lens (IOL) power calculation in long eyes remains challenging despite the availability of new formulas and biometers. This case report shows that optimization of the A-constant in the first eye can reduce postoperative refractive error in the second eye, even in the case of an IOL with negative power. This report aimed to describe a case in which this method was used to calculate IOL power to reduce postoperative refractive error in a long fellow eye. As far as we know, this is the first paper reporting the use of the optimized constant in the first eye to reduce postoperative error in the second eye in the case of a negative IOL. Case presentation: A highly myopic patient with nuclear cataracts underwent phacoemulsification cataract surgery (PCS) in both eyes. The axial length (AL) was 39.42 mm in the right eye and 37.45 mm in the left eye. All biometric data were obtained via low-coherence reflectometry using an OA-2000 biometer (Tomey, Nagoya, Japan). First, an IOL power calculation using the Barrett II formula and PCS was performed in the shorter eye. To evaluate the postoperative refractive error, the optimized A-constant in the left eye was estimated using the Camellin-Calossi formula. The new A-constant was then used for the right eye IOL power calculation using the same formula. The prediction error (PE) in the left eye was −0.23 D with the Barrett II formula. The optimized A-constant method using the Camellin-Calossi formula in the fellow eye gave −0.28 D of PE. Conclusions: The A-constant optimization for very long eyes, using data from the first operated eye, may be useful to reduce refractive prediction error in the second eye in very long eyes, as well as in the case of IOL power with negative values.
Open AccessIOL Power Calculation in an Unusual Long Fellow Eye: A Case Report
Background: Intra-Ocular Lens (IOL) power calculation in long eyes remains challenging despite the availability of new formulas and biometers. This case report shows that optimization of the A-constant in the first eye can reduce postoperative refractive error in the second eye, even in the case of an IOL with negative power. This report aimed to describe a case in which this method was used to calculate IOL power to reduce postoperative refractive error in a long fellow eye. As far as we know, this is the first paper reporting the use of the optimized constant in the first eye to reduce postoperative error in the second eye in the case of a negative IOL. Case presentation: A highly myopic patient with nuclear cataracts underwent phacoemulsification cataract surgery (PCS) in both eyes. The axial length (AL) was 39.42 mm in the right eye and 37.45 mm in the left eye. All biometric data were obtained via low-coherence reflectometry using an OA-2000 biometer (Tomey, Nagoya, Japan). First, an IOL power calculation using the Barrett II formula and PCS was performed in the shorter eye. To evaluate the postoperative refractive error, the optimized A-constant in the left eye was estimated using the Camellin-Calossi formula. The new A-constant was then used for the right eye IOL power calculation using the same formula. The prediction error (PE) in the left eye was −0.23 D with the Barrett II formula. The optimized A-constant method using the Camellin-Calossi formula in the fellow eye gave −0.28 D of PE. Conclusions: The A-constant optimization for very long eyes, using data from the first operated eye, may be useful to reduce refractive prediction error in the second eye in very long eyes, as well as in the case of IOL power with negative values.
- Open Access
- 27 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4311
One-Year Results of Photorefractive Keratectomy for Myopia and Compound Myopic Astigmatism with 210 nm Wavelength All Solid-State Laser for Refractive Surgery
Background: To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser. Methods: The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined. Results: The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to −0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from −0.03 ± 0.06 to −0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from −4.90 ± 2.12 D to −0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines. Conclusions: PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.
- 27 June 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (13) , 4311
Open AccessOne-Year Results of Photorefractive Keratectomy for Myopia and Compound Myopic Astigmatism with 210 nm Wavelength All Solid-State Laser for Refractive Surgery
Background: To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser. Methods: The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined. Results: The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to −0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from −0.03 ± 0.06 to −0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from −4.90 ± 2.12 D to −0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines. Conclusions: PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.
- 4 June 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (3) , 274-280
Prediction of total corneal power in keratoconus using anterior surface data
BackgroundThis study aimed to assess a method for predicting total corneal power in keratoconus using several anterior surface parameters at 3 mm and 4 mm.Methods Tomographic data obtained using Pentacam (Oculus, Germany) were analysed from 280 eyes of 140 patients with keratoconus using anterior and posterior keratometry, anterior Q-value at 8 mm, central corneal thickness, Kmax location and value, and true net power at 4 mm (TNP). Calculated total corneal power (TCPc) at 3 mm was obtained using the Gauss formula. Predicted total corneal power at 3 mm (TCPp3) and 4 mm (TCPp4) was obtained from univariate (TCPp3u and TCPp4u) and multivariate linear regression formulae (TCPp3m and TCPp4m). SimK, anterior Q-value, vertical location, and Kmax value were used in the multivariate formulae. Mean absolute error (MAE) and median absolute error (MedAE) were also calculated. Absolute frequencies within dioptric ranges of all formulas divided for keratoconus grading were evaluated.ResultsTCPc and TNP exhibited a good correlation (R2 = 0.58, p < 0.05) with a higher dispersion above 50 D of corneal power. Highly significant correlations were observed between TCPp3u and TCPc (R2 = 0.978, p < 0.05) and TCPp3m and TCPc (R2 = 0.989, p < 0.05). Lower but significant correlations were observed between TCPp4u and TNP (R2 = 0.692, p < 0.05) and between TCPp4m and TNP (R2 = 0.887, p < 0.05). The best results for TCP prediction at 3 and 4 mm were obtained with TCPp3m and TCPp4m as follows: MAE of TCPp3m was 0.24 +/- 0.20 (SD) D with MedAE of 0.20 D, while MAE of TCPp4m was 0.96 +/- 0.77 D with MedAE of 0.80 D. The 3 mm multivariate regression formula results in higher absolute frequencies of prediction errors in the total eyes within 0.5 D (93%) than the univariate formula (81%). At 4mm, the multivariate regression formula has a lower percentage within 0.5 D (32%) than the univariate formula (41%), but the percentage of the multivariate formula is higher within 1 D (63%) than the univariate formula (56%).ConclusionAll formulas show a decrease in accuracy with increasing grades of keratoconus. Multivariate linear regression formulae using only anterior surface data can predict TCP with good approximation in eyes with keratoconus in cases where posterior surface parameters are unavailable. The vertical location of Kmax and the anterior asphericity could play a relevant role in the prediction of total corneal power in keratoconus.
- 4 June 2023
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (3) , 274-280
Prediction of total corneal power in keratoconus using anterior surface data
BackgroundThis study aimed to assess a method for predicting total corneal power in keratoconus using several anterior surface parameters at 3 mm and 4 mm.Methods Tomographic data obtained using Pentacam (Oculus, Germany) were analysed from 280 eyes of 140 patients with keratoconus using anterior and posterior keratometry, anterior Q-value at 8 mm, central corneal thickness, Kmax location and value, and true net power at 4 mm (TNP). Calculated total corneal power (TCPc) at 3 mm was obtained using the Gauss formula. Predicted total corneal power at 3 mm (TCPp3) and 4 mm (TCPp4) was obtained from univariate (TCPp3u and TCPp4u) and multivariate linear regression formulae (TCPp3m and TCPp4m). SimK, anterior Q-value, vertical location, and Kmax value were used in the multivariate formulae. Mean absolute error (MAE) and median absolute error (MedAE) were also calculated. Absolute frequencies within dioptric ranges of all formulas divided for keratoconus grading were evaluated.ResultsTCPc and TNP exhibited a good correlation (R2 = 0.58, p < 0.05) with a higher dispersion above 50 D of corneal power. Highly significant correlations were observed between TCPp3u and TCPc (R2 = 0.978, p < 0.05) and TCPp3m and TCPc (R2 = 0.989, p < 0.05). Lower but significant correlations were observed between TCPp4u and TNP (R2 = 0.692, p < 0.05) and between TCPp4m and TNP (R2 = 0.887, p < 0.05). The best results for TCP prediction at 3 and 4 mm were obtained with TCPp3m and TCPp4m as follows: MAE of TCPp3m was 0.24 +/- 0.20 (SD) D with MedAE of 0.20 D, while MAE of TCPp4m was 0.96 +/- 0.77 D with MedAE of 0.80 D. The 3 mm multivariate regression formula results in higher absolute frequencies of prediction errors in the total eyes within 0.5 D (93%) than the univariate formula (81%). At 4mm, the multivariate regression formula has a lower percentage within 0.5 D (32%) than the univariate formula (41%), but the percentage of the multivariate formula is higher within 1 D (63%) than the univariate formula (56%).ConclusionAll formulas show a decrease in accuracy with increasing grades of keratoconus. Multivariate linear regression formulae using only anterior surface data can predict TCP with good approximation in eyes with keratoconus in cases where posterior surface parameters are unavailable. The vertical location of Kmax and the anterior asphericity could play a relevant role in the prediction of total corneal power in keratoconus.
- Open Access
- 13 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 3924
Sutureless Amniotic Membrane Transplantation in Inflammatory Corneal Perforations
Introduction: The aim of this study was to evaluate the efficacy of sutureless amniotic membrane transplantation (SAMT) in patients with corneal perforation secondary to ocular surface inflammatory diseases. Methods: Twelve eyes of eleven patients with corneal perforation associated with Sjögren’s syndrome and ocular cicatricial pemphigoid were included. Surgical procedure consisted in the application of two layers of amniotic membrane covering the corneal perforation and a therapeutic contact lens placed above the two layers, followed by sutureless tarsorrhaphy with Steri-strip applied for 15 days to immobilize the eyelids. All patients underwent slit-lamp examination, fluorescein corneal staining, and anterior segment optical coherence tomography (AS-OCT), preoperatively and post-surgery, weekly for one month, and then every two weeks for three months. Results: All 12 eyes had complete resolution of corneal perforation. Pachymetry measurements improved in all eyes, and complete healing of the corneal ulcer was obtained following treatment and maintained up to 3 months follow-up in all patients. Conclusions: SAMT was proven to be a safe and effective option for the management of inflammatory corneal perforation. The procedure is non-traumatic and easy to perform since the surgical technique is sutureless and does not require topical therapy because it takes advantage of the intrinsic properties of the membrane itself.
- 13 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 3924
Open AccessSutureless Amniotic Membrane Transplantation in Inflammatory Corneal Perforations
Introduction: The aim of this study was to evaluate the efficacy of sutureless amniotic membrane transplantation (SAMT) in patients with corneal perforation secondary to ocular surface inflammatory diseases. Methods: Twelve eyes of eleven patients with corneal perforation associated with Sjögren’s syndrome and ocular cicatricial pemphigoid were included. Surgical procedure consisted in the application of two layers of amniotic membrane covering the corneal perforation and a therapeutic contact lens placed above the two layers, followed by sutureless tarsorrhaphy with Steri-strip applied for 15 days to immobilize the eyelids. All patients underwent slit-lamp examination, fluorescein corneal staining, and anterior segment optical coherence tomography (AS-OCT), preoperatively and post-surgery, weekly for one month, and then every two weeks for three months. Results: All 12 eyes had complete resolution of corneal perforation. Pachymetry measurements improved in all eyes, and complete healing of the corneal ulcer was obtained following treatment and maintained up to 3 months follow-up in all patients. Conclusions: SAMT was proven to be a safe and effective option for the management of inflammatory corneal perforation. The procedure is non-traumatic and easy to perform since the surgical technique is sutureless and does not require topical therapy because it takes advantage of the intrinsic properties of the membrane itself.
- 1 March 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 32 (3) , 1828-1832
Double safe suture during cataract surgery on post radial keratotomy patients using clear corneal incisions
Purpose: the aim of this study is to find a safer surgical approach in cataract surgery on eyes previously treated with radial keratotomy using clear corneal incisions. Setting: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Ophthalmology Clinic, University of Messina, Messina, Italy. Design: Prospective study. Methods: A prospective study was conducted on a group of 20 patients, 21 eyes with 16 RK incisions were evaluated for cataract phacoemulsification. Samples were divided into two groups: Group 1 underwent surgery with pre-operative one corneal stitch along radial keratotomy incisions near the main access site whereas Group 2 underwent modified surgery with two corneal stitches. Results: After surgery, visual acuity, corneal hysteresis and corneal strength was evaluated. In all cases, an increased visual acuity was observed. Group 1 showed an UCVA of logMAR 0.22 ± 0.14, while group 2 presented a logMAR of 0.1 ± 0.07. Data did not show a statistically significant difference in UCVA after surgery between the two groups ( P = 0.133). Instead, a significant difference in corneal hysteresis (CH), respectively with values of 8.65 ± 1.6 mmHg in group 1 and 9.2 ± 1.8 in group 2 ( P = 0.031), and a corneal resistance factor (CRF) with values of 7.87 ± 1.4 mmHg in the first group and 8.65 ± 1.6 mmHg in the second one ( P = 0.039) was observed. Conclusions: Double safe suture technique offers better stabilization of corneal structure during surgery in patients preventively treated with 16 incisions RK.
- 1 March 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 32 (3) , 1828-1832
Double safe suture during cataract surgery on post radial keratotomy patients using clear corneal incisions
Purpose: the aim of this study is to find a safer surgical approach in cataract surgery on eyes previously treated with radial keratotomy using clear corneal incisions. Setting: Department of Biomedical and Dental Sciences and Morphofunctional Imaging, Ophthalmology Clinic, University of Messina, Messina, Italy. Design: Prospective study. Methods: A prospective study was conducted on a group of 20 patients, 21 eyes with 16 RK incisions were evaluated for cataract phacoemulsification. Samples were divided into two groups: Group 1 underwent surgery with pre-operative one corneal stitch along radial keratotomy incisions near the main access site whereas Group 2 underwent modified surgery with two corneal stitches. Results: After surgery, visual acuity, corneal hysteresis and corneal strength was evaluated. In all cases, an increased visual acuity was observed. Group 1 showed an UCVA of logMAR 0.22 ± 0.14, while group 2 presented a logMAR of 0.1 ± 0.07. Data did not show a statistically significant difference in UCVA after surgery between the two groups ( P = 0.133). Instead, a significant difference in corneal hysteresis (CH), respectively with values of 8.65 ± 1.6 mmHg in group 1 and 9.2 ± 1.8 in group 2 ( P = 0.031), and a corneal resistance factor (CRF) with values of 7.87 ± 1.4 mmHg in the first group and 8.65 ± 1.6 mmHg in the second one ( P = 0.039) was observed. Conclusions: Double safe suture technique offers better stabilization of corneal structure during surgery in patients preventively treated with 16 incisions RK.